| 1 | Demolition of Brickwork or stone/ boulder masonry, built in CM incl all quoins, arches, pillars, etc, complete all as specified and directed . |
| 2 | M&L for walling or random rubble , uncoursed well bonded, bedded and solidly, hearted built in CM 1:6 etc complete all as specified and directed. |
| 3 | -do- all as per item No 2 above but except stones complete all as specified and directed. Note- Serviceable stones obtained vide item No 01 shall be reused after removing mortar and cleaning with water complete all as specifed and directed. . |
| 4 | Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints with max depression on face from straight edge held against the dressed surfaces not exc 40 mm as specified of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.Note: Hidden portion of stone masonry shall not be hammer dressed complete all as specifed and directed. |
| 5 | M&L Pre-cast AAC blocks masonry GR-1 of size 600x200x100/150/200mm and setting in CM 1:6,complete complete all as specified and directed |
| 6 | Dismantling of stone/ boulder masonry, built in CM incl all quoins, arches, pillars, etc, complete all as specified and directed . |
| 7 | M&L for Boulder pitching grouted with cement and sand mortar 1:6, hand packed tightly complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L for Boulder pitching grouted with cement and sand mortar 1:6 except stone, hand packed tightly complete all as specified and directed by Engr-in-Charge. |
| 9 | Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed |
| 10 | M&L for 8mm thick rendering in CM 1:4 on stone / Brick masonry surfaces and concrete surfaces including finishing the surface even and smooth without using extra cement over backing coat of 12mm thick in CM 1:6 complete all as specified and directed. |
| 11 | Supply only liquid WPC |
| 12 | M&L For Raking out joints/ pointing random rubble or polygonal rubble uncoursed or brought up to courses on edge in floors, surface channels, roofs, etc at any height complete all as specified and directed by Engr-in-Charge. |
| 13 | M&L For Raised pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:3 at a height of about 20 mts complete all as specified and directed by Engr-in-Charge.Note:Pointing to be done on flat or inclined surface of dam (d/s side) upto 25 mtr ht. The rate should include necessary scaffolding etc. |
| 14 | Demolition of cement concrete unreinforced in of any desciption and in any position complete all as specified and directed by the EIC. |
| 15 | M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping/benching and all other similar works including necessary formwork complete all as directed. |
| 16 | M&L for PCC (1:3:6) type C2 using 40 mm graded aggr as in surface channels and drains complete all as directed and specified. |
| 17 | M&L 75mm thick PCC type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base all as specified and directed by Engr in Charge. |
| 18 | M&L for extra for forming fair finished drain or channel in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc. |
| 19 | Removing/cleaning of silt, mud,etc at any location in the drain of any width and length in soft/loose soil including gallery portion of Dam and removed material from site at a distance exc 500 m and n exc 1.5 KM deposited where directed by Engr-in-Charge.Note-No extra payment will be made to the contractor for vehicles used for taking the debris outside MD land |
| 20 | M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering etc. complete all as specified and directed by Engr-in-Charge. |
| 21 | S&F Acrylic letters (English) 300 mm high, 50 mm width and 30 mm depth hollow wall fixed on curve shape of Angle Frame and incl 3mm ACP sheets board in curve shape fixed with angle frame of any description using stainless steel screws of suitable size or best quality adhesive including LED module rain proof lights fittings in each letters complete all as specified and as directed by Engr-in-charge. |
| 22 | S&F for Pre- Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, including taking down complete all as specified and directed. |
| 23 | M&L for 18-20mm thick Granite work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over 15mm thick in cement mortar (1:4) bedding including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and moulding/rounding to edges of stone slabs etc, complete all as specified & directed. Note: Granite stone slab shall be in single piece to fit. |
| 24 | Dismantling wrought iron or mild steel work of any description not otherwise provided for etc, complete all as specifed and directed by EIC. |
| 25 | S&F Angle Iron and FI,balusters,nosing to steps including embeding in concrete and screwing etc.securing bolts;posts and struts in fencing including cutting tops tob shape as directed,drilling holes,notching for wire,etc.;flat iron fillet (for securing wire mesh etc.,and similar work conforming to Fe 290. Gde E-165, complete all as specified and directed by EIC. |
| 26 | M & L for Preparation of New painted steel surfaces of any description having width/girth exceeding 10cm and apply Two coat of anti corossive epoxy paint over one coat of epoxy primer complete all as specified and and directed by EIC. |
| 27 | M & L for Preparation of old painted steel surfaces of any description having width/girth exceeding 10cm and apply Two coat of anti corossive epoxy paint over one coat of epoxy primer complete all as specified and as directed by EIC. |
| 28 | M&L for cutting or uprooting grass on old mud phuska/Stone/brickwall any type surfaces (Verticle surfece/Incline Surface), removing rubbish off the premises, cleaning surface, repair damage portion and match with existing surface (material use for repair as per existing surface) and applying props,shuttering etc to reach at any height of not exc.30 m for cutting of grass and repair of damage surface etc. complete all as specified and directed by Engr-in-Charge. |
| 29 | M&L for cutting or uprooting grass on old mud phuska/Stone/brickwall at ground level, removing rubbish off the premises, cleaning surface, repair damage portion and match with existing surface (material use for repair as per existing surface) etc. complete all as specified and directed by Engr-in-Charge. |
| 30 | M&L for grubbing up tree trunk n exc 20cm girth including cutting of trunk portion protruding over ground and removing of unserviceable material to a distance n exc. 50 m and clearing site complete all sa specified and direcvted by Engr-in-Charge. |
| 31 | M & L for plastering minimum thickness Dr.fixit repair polymer mortar 20 mm Polymer modified mortar(ready mix pack) in two coat 15 mm base coat and 5 mm finishing coat with and incl curing as per manufacturer istruction all as specified and directed. Please Enable Macros to View BoQ information |