| 1 | 14.20 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 15.20.1 For thickness of tiles 10 mm to 25 mm |
| 2 | 17.30 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge17.30.3 25 mm average thickness |
| 3 | 10.42 Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge. 10.42.1 Soluble Salt Stainfree vitrified tiles (Glossy) 10.42.1.1 Size of tile 600 mm x 600 mm |
| 4 | 10.40 Providing and fixing 1st class quality ceramic glazed wall tiles conforming to IS : 15622- 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-in charge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade etc. all complete as per direction of the Engineer in-charge.10.40.2 600 mm X 300 mm in all shades and design |
| 5 | 12.35 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture to give an even shade[Payment shall be made after submission of Test Certificate issued by the Manufacturer] :12.35.1 New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 6 | 19.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 19.53.1 15 mm nominal bore |
| 7 | 19.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 19.52.1 15 mm nominal bore. |
| 8 | DISMANTLING CUBOARD AND RACKS NAD DISPOSAL |
| 9 | PROVIDING AND FIXING COMMODE COVER |
| 10 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mmthick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 11 | 18.18 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 18.18.1 10 litre capacity-White. |
| 12 | 18.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting18.7.2 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps. |
| 13 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 14 | 19.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot&coldwatersupplyincludingallCPVC plain brassthreadedfittingsincludingfixingthepipewith clampsat 1.00mspacing. This includes jointingof pipes&fittingswithonestepCPVC solvent cement and testingof joints complete asper directionof Engineer in Charge. Internal work - Exposed on wall19.7.1 15 mm nominal outer dia .Pipes. |
| 15 | Dismantling and disposal of damaged doors to disposal site as per direction of Engineer-In- Charge |
| 16 | 8.19 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veeners on both faces of shutters. 8.19.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 17 | 13.33 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 18 | 12.19 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 19 | 18086 600x120 mm glass shelf with anodised aluminium angle frame, C.P.brass brackets and guard rail of standard size |
| 20 | 13.30 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal ofrubbish to the dumping ground with all leads and lifts including finishing even and smooth and curing complete as per direction of the Engineer in charge:3.30.2 With cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 21 | Anodised Aluminium sliding door bolt 300x16 mm |
| 22 | Providing and fixing bright finished brass handles with screws etc. complete :8.79.1 125 mm |
| 23 | 8.61 Providingandfixing ISImarkedoxidisedM.S. tower boltblackfinish, (Barrel type)ithnecessaryscrews etc. complete :8.61.1 250x10 mm |
| 24 | 9.24 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :9.24.1 4.0 mm thick glass panes |
| 25 | 13.20 Renewal of old putty of glass panes (length). |
| 26 | 18.59Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter : 18.59.1 100 mm |
| 27 | 8.64ProvidingandfixingISImarkedoxidisedM.S.handles conforming to IS:4992 with necessary screws etc.complete : 8.64.1 125 mm |
| 28 | .115 Providing and fixing to existing door frames. 8.115.1 24 mm thick factory made PVC door shutters made ofstyles and rails of a UPVC hollow section of size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of M.S. galvanised /plastic brackets of size 75×220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserying galvanised MStube of size 20×20 mm and 1 mm ± 0.1 mm wallthickness. The lock rail made up of \\"H\\" Section, a UPVC hollow section of size 100×24 mm and 2 mm ± 0.2 mm wall thickness fixed to the shutter styles by means of plastic /galvanised MS \\"U\\" cleats. The shutter frame filled with a UPVC multi-chambered single panel of size not less than 620 mm, having overall thickness of 20 mm and 1 mm ± 0.1 mm wall thickness. The panels filled vertically and tie bar at two places by inserting horizontaly 6 mm galvanised MS rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-In-Charge. (for W.C. and Bathroom door shutter). |
| 29 | 16.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineerincharge. (Glazing and paneling and dash fasteners to be paid for separately) : |
| 30 | 16.2 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board grade-I, type II conforming to IS : 12823 bonded with phenol formaldehyde synthetic resin, of approved brand and manufacture in panelling fixed in aluminium doors, windows, shutters and partition frames with C.P. brass / stainless steel screws all complete as per architectural drawing and the direction of Engineer-in-charge : 16.2.1 Prelaminated particle board of approved quality with decorative lamination on one side and balancing lamination on other side |
| 31 | 16.3 Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) : 16.3.1 With float glass panes of 4.0 mm thickness ( weight not less than 10.0 kg / sqm ) |
| 32 | 8.45 Providing and fixing nickel platedM.S. pipe curtainrods with nickel plated brackets:8.45.1 20 mm dia (heavy type) Please Enable Macros to View BoQ information |