| 1 | TREATMENT OF WALLS : |
| 2 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. |
| 3 | Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete. |
| 4 | Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. |
| 5 | Lowering down the debris obtained from breaking and removing the cement plaster / burnt brick masonry of the first floor by any means without causing dust nuisance and damage to structure, stacking the same as and where directed including cleaning the site |
| 6 | Providing and fixing welded mesh fabric for guniting of mesh size 75 mm x 75mm and 10 gauge thick including scaffolding etc. complete |
| 7 | Providing and fixing Jute Kantan (Tarat) screen to the scaffold-ing for external guniting as directed including removing the same after the work is over etc. complete |
| 8 | Guniting by dry mix process as per IS 9012 ( 1978) to ceiling sofit etc. in C.M. 1:3,40mm thick under pressure of 2.1 Kilogram to 2.8 Kilogram per sq.m including forms, scaffolding, floating the surface, curing for 14 days etc. complete (Excluding reinforcement) |
| 9 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 Kilogram per cement bag curing the same for not less than 2 day sand keeping the surface of the base coat rough to receive the sand faced treatment 6to8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 10 | Mortar will be machine mixed, volumetrically batched. |
| 11 | Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete. |
| 12 | Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc.complete. |
| 13 | Providing and applying one pack bonding coat between concrete members like RCC slabs, columns, beams, chajjas, pardis etc and cement mortar plaster using Hack Aid Plast of approved make & approved by Engineer in charge. Clean the concrete surface thoroughly to remove dust, dirt, grime, deshuttering oils and rub down to a clean surface. Apply Hack Aid Plast of approved make & approved by Engineer in charge by spray on the entire concrete surface. Provide a lean cement - sand dash coat over the same. Allow the dash coat to set for around 24 hours. Further plastering as per specifications can continue. |
| 14 | Waterproofing Treatment to existing Terrace by using Polymeric cementitious membrane of approved make & approved by Engineer in charge by replacing the existing waterproofing treatment. Break open the existing I.P.S. and brick bat coba of the terrace slab to expose the bare slab. (If there are cracks on the bare slab open the crack in V Groove and fill it with P.M.M. and if there are lots of honeycombs and identified bad patches of concrete the same should be grouted by grouting procedures). Clean the entire surface thoroughly and over this prepared surface, apply three coats of polymeric waterproofing coating having a breathable non toxic acrylic polymer liquid of approved make & approved by Engineer in charge,over this waterproofing treatment, provide and lay brick bat coba of average 112 mm thickness. |
| 15 | Chajjas |
| 16 | CORROSION CONTROL: |
| 17 | Providing Repairing of honeycombs and minor damages with Polymer Modified Morter including material, labour complete in all respect |
| 18 | Providing and Fixing of 12 mm nozzle in the crack portion @ 500 c/c including material, labour complete in all respect.(40% Considered) |
| 19 | Filling voids/honeycomb with high pressure injection grouting of Polymer Cement Grout (10% of Polymer by Weight of Cement) |
| 20 | STRUCTURAL REPAIR (GUESSTIMATE) |
| 21 | Providing and fixing in position HCRM / CRS (Corrosion Resistant Steel) bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 22 | Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines.The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill,cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug.The installation and the setting instructions should be strictly followed as per the manufacturer‘s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval.Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -10 mm dia 200mm depth |
| 23 | Providing and laying Cast in situ/ Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finishis to be provided and curing etc. complete, (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 24 | Providing and laying Cast in situ/ Ready Mix cement concrete in M-20 of trap/granite/quartzite/gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, coverblocks, laying/pumping, compacting, curing, finishing and rough ening themif special finish is to be provided and curing complete. (Excludingreinforcementandstruct uralsteel). with fully automatic micro processor based PLC with SCADA enable dreversible Drum Type mixer/ concrete Batch mix plant (Panmixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 25 | Providing and laying insitu / ready mix M35 grade RCC jacketing work around the existing piers of bridges etc. complete. (with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer with fine aggregates of required specifications ( VSI sand finely washed etc ), height of 8 to 10 meter). |
| 26 | Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts etc. |
| 27 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 28 | Providing filling of Micro-concrete and 10 mm aggregate ( 1:1) including sacrificial leak proof MS shuttering includes the cost of hire charges of all machineries, barge, boat, cost of all tools and all labour charges etc. complete |
| 29 | SERVICE ITEMS |
| 30 | Removing doors and windows with frames and stacking the materials as directed with all lead lifts etc. complete. |
| 31 | Providing and fixing in position aluminium openable window of any size as per detailed drawing and as directed by Engineer in charge with all necessary aluminium sections including necessary fixtures and fastening with 5 mm thick clear float glass etc. complete. a) With colour anodizing Note While arriving at the rate of item of item weight at 6.90 Kilogram / Square Metre is considered. |
| 32 | Providing and fixing in position (as per 1868 / 1982 ) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram / Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram / Running metre. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram / Running metre.The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram / Running metre.Interlocking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram / Running metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 Kilogram /Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastening such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts etc,complete |
| 33 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding |
| 34 | Providing and fixing green marble/granite of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete. |
| 35 | WATERPROOFING OF TERRACE: |
| 36 | Waterproofing treatment to new terrace by using chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane as approved by Engineer in charge, followed by average 112mm thick brick bat coba covered with 40mm thick IPS. The procedure includes filling of cracks on the RCC slab with high performance polyurethane (liquid applied) membrane. Clean the entire surface thoroughly and over this prepared surface, apply a primer coat of high performance polyurethane (liquid applied) membrane as approved by Engineer in charge on surface. Ensure that pinholes are touched up properly. While the second coat of high performance polyurethane (liquid applied) membrane is wet and tacky, sprinkle coarse sand over the surface to make it rough and provide mechanical key for further treatment. Provide and lay average 15 mm thk protective coat of CM in 1:4 over the surface and allow to set and cure. Provide and lay 112 mm thk BB coba in average thickness in cement mortar 1:5 with one pouch of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents - which is based on special cements, aldehyde based polymers, shrinkage compensating agents and selected sands having high abrasion resistance as approved by Engineer in charge per 50 Kg bag of cement and finishing with 40 mm thick IPS layer in M 20 CC by mixing one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents per 50 Kg bag of cement, including all leads, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of parapet and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatment with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. The liquid membrane should have a track record of atleast 4 years in India & Gulf region and have atleast an 4 year track record in PWD. Single Component, Liquid Applied, chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane should have following minimum properties: 1) Water Permeability (DIN 1048): Nil as per DIN 1048 @ 7 bar of Hydrostatic Pressure. 2) Moisture Permeability: < 0.4 g/m2/day 3) Accelerated Weathering (IS 101): 2000 hrs No cracking or blister formation 4) Adhesion to concrete (ASTM D 1000): >21 Kg/cm2 (ConcreteFails) 5) Tensile Strength: > 2.0 MPa (ASTM D412) 6) Should not be water soluble or water |
| 37 | Main terrace & OHWT |
| 38 | Do with broken China mosaic flooring instead of IPS set in cement mortar (1:4) 40 mm thick |
| 39 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 40 | Clean the R.C.C. roof slab surface of all loose particles, dust, cement laitance etc. preferably done by using machine like device. Inspect for cracks/construction joints. Fill the cracks by Flexiroof PU of approved make & approved by Engineer in charge (This coating is to be protected by providing I.P.S. on top of it). Provide and apply a primer coat of Flexiroof PU Primer of approved make & approved by Engineer in charge on the cleaned RCC deck surface using a soft paint brush. Shake the container well and directly apply the primer by brush. Allow it to set for 30 - 45 mins. Provide and apply Flexiroof PU of approved make & approved by Engineer in charge by brush, roller or airless spray equipment. Apply at a rate of 1 Kilogram/Square Metre for the first coat evenly over the primer surface and allow to set for 12 hours. After ensuring that the first coat is set and cured, apply the second coat in similar manner at a rate of 0.5 Kilogram/Square Metre and allow to set. While the second coat is has reasonably hardened but still wet and tacky on surface, sprinkle sand over the surface to make it rough so as to provide mechanical key for the protective screed/IPS. Ensure that the sand does not gets embedded in the second coat and remains on the surface. Allow the two coats of Flexiroof PU of approved make & approved by Engineer in charge to air cure for 4-5 days before proceeding with the protective screed. This should be followed by application of compatible IPS of 25 MM thick waterproof bedding. The liquid membrane should have a track record of atleast 4 years in India & Gulf region and have atleast an 4 year track record in PWD. Single Component, Liquid Applied, Polyurethane Membrane should have following minimum properties: 1.Water permeability (DIN 1048): Nil as per DIN 1048 @ 7 bar of hydrostatic pressure. 2. Moisture permeability: < 0.4 g/m2/day 3. Accelerated Weathering (IS 101): 2000 hrs No cracking or blister formation. 4. Adhesion to concrete (ASTM D 1000): >21 Kilogram/cm2 (Concrete Fails) 5.Tensile Strength: > 2.0 MPa (ASTM D412) 6. Should not be water soluble or water dilutable OHWT |
| 41 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murmt, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 42 | Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. |
| 43 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap granite/quartzite /gneiss metal for arches including skew backs as per detailed drawing or as directed in superstructure including steel centering, formwork, compacting, finishing with minimum thickness of 1:3 cement plaster to give a smoot hand even surface or roughening the m if special finish is to be provided and curing and finishing if required complete, with fully automatic microprocess or based PLC with SCADA enabled reversible Drum Typemixer. complete,.Withfineaggregate(Crushed sand VSI) |
| 44 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete |
| 45 | Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. |
| 46 | Providing and laying ceramic tiles of having size 30 cm. x 30 cm.and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete..(Basic Rates for Tiles is Rs.300/Sq M |
| 47 | Providing and laying Polished Kota stone flooring With Hand-Cut Polished Kota Stones 25mm to 30mm thick and required width in plain/diamond pattern on bed of 1:6 Cement mortar including cement float, filling joints with neat cement slurry, curing, cleaning and Mirror Polishing etc. complete Note- Water absorption for kota stone should not exceed 0.05%.( Item to be used with prior permission of Superintending Engineer) |
| 48 | Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. |
| 49 | Providing and fixing 10 cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete |
| 50 | Breaking, chiseling, off old waterproofing treatment, along-with old brickwork coba, and exposing the bare R.C.C. slab. (Average thickness of 1' considered) Lowering, stacking and carting away all the debris as and when enough lorry loads are accumulated. Waatas Measured in RM. Chipping, cleaning the R.C.C. slab, and covering entire slab with cement slurry, after washing thoroughly with water. Providing, fixing and injection by gravity method, cement slurry injection into the old hollow core of the R.C.C. slab as and where found necessary. (If require to done shall be paid extra as per Item 4 above). Laying fresh layer of brickbat coba in 1:6 (C:M)mortar. Covering brickbat coba, with jointless waterproof plaster 1:4 mortar. |
| 51 | PLUMBING WORKS: |
| 52 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con- crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete. |
| 53 | Providing and fixing white european type wall-hung, Size 360mm x 360mm x 575 mm with flush valve having flow rate up to 6.0 Litr/Minute of Jaquar/Cera/Hindware/Perryware or equivalent make including PVC soil pipe, vent pipe upto outside face of wall, 100mm dia PVC plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) |
| 54 | Providing and fixing C.P. Brass two way bib cock of approved make continental including necessary sockets/union nut etc. complete. |
| 55 | Providing and fixing Health Faucet with one metre long easy flex tube in chrome finish and wall flange |
| 56 | Providing and fixing wall-hung white wash basin of size 470x 575x 190mm of approved make half pedestal, pillar cock, C.P. Angular stop cock, long thread continental including S.S. bottle trap of having necessary pipe connections upto the outside face of the wall.etc complete. |
| 57 | Providing and fixing coloured Glazed Earthen ware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fitting sand flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall |
| 58 | Providing & fixing 20mm +/- 2mm thick both side mirror polished approved colour Granite Urinal partitions of 600 mm wide & 1550 mm high with round edges moulding and fixed in C.M. 1:2and filling joints in white cement mixed with pigment to match the colour of granite including curing, cleaning etc.complete.(Basic Rate Rs 3600/sqm) |
| 59 | Providing and fixing 20mm dia. Screw down bib/ stop tap of brass including necessary socket union nut complete. |
| 60 | Providing & Fixing CPVC 20mm dia in Bath, Toilet & Kitchen with nessesary clamping etc complete. |
| 61 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S.13592-1992 including proper rain water receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 62 | 110 mm dia. For Soil & Rain water. |
| 63 | Providing and fixing 75 mm dia stabiliser pipe /P.V.C. soil vent/ waste pipe and with necessary fixture sand fitting such as bends, tees, single junctions, slotted vent, clamps etc. Complete |
| 64 | Providing and fixing square-mouth S.W. gully trap class SP-1complete with C.I. grating brick masonry chamber with water tightC.I. cover with frame of 300 x300 mm size (inside) the weight ofcover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design:19.4.1 100x100 mm size P type19.4.1.1 With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 19.4.1.2 With Sewer bricks conforming to IS : 4885 |
| 65 | Providing and laying for 150 mm dia salt glazed stoneware pipe including fittings Such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete |
| 66 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. |
| 67 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 68 | Providing and fixing on walls/ceiling/floor 20 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 69 | Providing, fixing new G.M. gate valve I.S.I. Marked heavy duty with G.I. Assorted fitting(s) I.S.I. Marked such as tee, elbow, nipple, cupling, union, G.I. Clamp(s) and nails etc. and removing old valve (s) etc. |
| 70 | Providing, fixing and testing heavy quality gun metal or brass ball valve with screwed ends 20kgm class on GI or copper pipe lines (Leader/ZOLOTO make) 20 mm (3/4\\") dia. |
| 71 | Providing, fixing and testing heavy quality gun metal or brass ball valve with screwed ends 20kgm class on GI or copper pipe lines (Leader/ZOLOTO make) 25 mm (1\\") dia. |
| 72 | Providing, fixing and testing heavy quality gun metal or brass ball valve with screwed ends 20kgm class on GI or copper pipe lines (Leader/ZOLOTO make) 40 mm (1 1/2\\") dia. |
| 73 | Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete |
| 74 | Painting Works |
| 75 | Providing and applying Elastomeric, Anti carbonation, Anti corrosive, UV resistant, Solvent based Pure Aliphatic Acrylate System- MONOPOL 456 on the exterior faces of Buildings Protection against ION penetration, carbonation, UV radiations and wethering effect conforming to ASTM D 4541-02 having Electrochemical impedance of 107 Ω and achieving dry film thickness of minimum 200 microns in a primer coat followed by two top coats using brush or spray after complete cleaning & removal of oil, grease or loose particles from the surface etc. complete. |
| 76 | Providing and applying epoxy paint primer with middle coat and top coat to superstructure including scaffolding etc complete.-MS Surface |
| 77 | Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. |
| 78 | Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint of approved colour that belongs to class 1 flame spread resistance of approved make Paint should provide durable and long lasting silk finish with a high crack tolerance of upto 1mm. Paint should have an outstanding wash ability with high resistance to wide range of bacteria and fungus. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC Primer. The work activity should cover all aspects of applying paints from surface preparation as directed by Engineer in charge. |
| 79 | Solid Core Flush door Single leaf Providing and fixing factory made solid core flush door in single leaf 35mm thick, decorative types, of exterior grade, as per detailed drawings, conformingtoI.S.:2202-1962(Revised)with approved face veneers on both face swith/ with out glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, hold fasts, mat finish stainless steel fixtures fastenings, finishing with french-polish/ waxing complete. (with out door frame). (Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter |
| 80 | Solid Core Flush door Double leaf Providing and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 – 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter |
| 81 | Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150 Kilogram capacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc. Complete |
| 82 | Expansion joint treatment |
| 83 | Providing & Fixing 450mm *550mm size superior type Belgium mirror with 60mm dia nickle plate D Towel, Rod Etc Complete |
| 84 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/ bolted/ welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. |
| 85 | Providing antitermite treatment to the sides of flooring of the existing building as per I.S.6313 (Part-III) by punching holes 6mm dia. drilled at a distance of 30cm. centre to centre and injecting one percent of chlorodane emulsion concentrate at the rate of 50 ml per hole and sealing by filling putty etc. complete covering 2 years guarantee on bond paper. Please Enable Macros to View BoQ information |