| 1 | Electrification |
| 2 | OD3315/2026-2027:Installation, Testing & Commissioning of a Separate Battery Charger near to the DG Battery Sets in order to maintain the battery charge in good condition while DG sets kept standby for long time , Input 1Ph 240V AC ,Output 24V DC, 10A ,Fully Automatic , Boost & Float Charger, with input & out put protection breaker/Fuse, 240V 16A 3 PIN Industrial Male & Female Socket with 1 meter 3Cx1.5 mm² 660V Cu Flexible Cable |
| 3 | OD3317/2026-2027:Installation , Testing & Commissioning of Power Distribution Panel , Wall Mounting , 415V ,3PH , 4 W, 400A, 12WAYS , MCCB as Incomer & MCCB AS outgoing devices, Conforms to IEC61439-2, Short-time withstand Current 36kA for 1S, Ingress Protection IP43, ready to Use , Brand : L&T Switchgears , SMDB-TN400D, Cat No.DA40D1124CZZ0 |
| 4 | OD3318/2026-2027:Installation , Testing & Commissioning of Bottom Cabling Box in the existing Power Distribution Panel , SMDB-TN400D Brand : L&T Switchgears , Type SMDB-TN400D, Cat No.CM90437OOOO |
| 5 | OD3319/2026-2027:Installation , Testing & Commissioning of Corner Box in the existing Power Distribution Panel , SMDB-TN400D Brand : L&T Switchgears , Type SMDB-TN400D, Cat No.CM910890000 |
| 6 | OD3322/2026-2027:Installation , Testing & Commissioning of Mounting Base in the existing Power Distribution Panel , SMDB-TN400D , Brand : L&T Switchgears , Type SMDB-TN400D, Cat No.CM70260OOOO |
| 7 | OD3324/2026-2027:Installation , Testing & Commissioning of Left Side Cabling Box in the existing Power Distribution Panel , SMDB-TN400D , Brand : L&T Switchgears , Type SMDB-TN400D, Cat No.CM91087OHOO |
| 8 | OD3325/2026-2027:Installation , Testing & Commissioning of Right Side Cabling Box in the existing Power Distribution Panel , SMDB-TN400D , Brand : L&T Switchgears , Type SMDB-TN400D, Cat No.CM91088OHOO |
| 9 | OD3326/2026-2027:Installation , Testing & Commissioning of Incomer MCCB , 3 POLE, 400A, 36kA in the existing Power Distribution Panel , SMDB-TN400D , Brand : L&T Switchgears , Type DN3-400D, Cat No.CMCM94005OOR1OG |
| 10 | OD3327/2026-2027:Installation , Testing & Commissioning of Outgoing MCCB , 3 POLE, RANGE 20-100A, 25kA in the existing Power Distribution Panel , SMDB-TN400D , Brand : L&T Switchgears , Type DN0-100C |
| 11 | OD10480/2026-2027:Installation , Testing & Commissioning of Metering Extension Box in the existing Power Distribution Panel , SMDB-TN400D Brand : L&T Switchgears , Type SMDB-TN400D, Cat No.CM90439OOPO |
| 12 | OD10481/2026-2027:supply and fixing of Single Phase Ammeter accuracy class 1 with necessary connected item as required |
| 13 | OD10482/2026-2027:Supply & Fixing Digital type Multifunction Meter to read V,A,F 3phase Accuracy class 1 , L&T Make and making connections as required |
| 14 | OD536308/2025-2026:Supply, conveyance of 250 KVA Diesel Generator set with integral acoustic enclosure as per CPCB -IV + norms with standardised accessories as pertechnical details given below. 1. Engine : a) Make of Engine - Kirloskar//Cummins/Leyland/Volvo b) Typeof Engine - Diesel Engine c) No. of Cylinders - As per manufactures standards. d) Method of Cooling -Water cooled with radiator. e) Design - Suitable for generating set operation 2.Standard accessories withDiesel Engine a) Fly wheel to suit flexible coupling b) Close Coupling c) Air cleaner d) Radiator with fanprovided with fan guard. e) Fuel Pump f) Fuel filter g) Lubricating oil filter h) Exhaust silencer i) ExhaustMuffler j) Battery Charger/Generator 3. Engine Instrument Panel with the following items a) Startingswitch with key or button b) Lubricating oil pressure gauge. c) Water temperature gauge. d) RPMIndicator with hour meter e) Battery charging Ammeter 4. Safety Controls for Engine a) Trip for lowlubricating oil pressure b) Trip for high water temperature. 6. Brushless Alternator a) Make -Kirloskar/KEL//Stanford/LS b) Type - Self exited and self regulated. c) Capacity - 250 KVA/200 K W @0.8PF d) System of Voltage - 3 phase, 415 V, e) Frequency - 50 Hz f) Insulation - Class F/H TheAlternator should confirm to IS 4722. Operation and service manual, spares and tools shall be provided.7. Fuel Tank Suitable size built in type integrated with the acoustic enclosure Fuel connection shall bedone as per standards 8. Battery Suitable size built in type integrated battery with leads and terminals ofappropriate AH capacity as per Manufactures requirement. Automatic Battery charger Solid state phaseindication lamp for supply ON/OFF with HRC protection. standard conrol panel as per kerala ElectricalInspectorate requirements, with 400A 4 pole MCCB and accessories such as Multi function metre andseperate Energy metre etc.Complete. |
| 15 | OD507593/2025-2026:Installation , testing and commissioning of 250 KVA Diesel generator set. |
| 16 | OD507604/2025-2026:Supply and providing the following size of B class MS pipe conforming to relevant IS :1239 PART-1(2004) specifications complete with heavy gauge specials such as bends, flanges etc welded and fixed atappropriate locations providing cork sheet in between the flanges at the joints, bolting the flangestogether, painting the pipe, flanges etc with 2 coats of heat resistant paint suitable for outdoorapplications fixing the pipe firmly with fabricated structure/ mechanical support etc as required 100 mmdia. |
| 17 | OD507599/2025-2026:Supply and providing the following size of B class MS pipe IS:1239 PART-1 (2004) conforming torelevant IS specifications complete with heavy gauge specials such as bends, flanges etc welded andfixed at appropriate locations providing cork sheet in between the flanges at the joints, bolting the flangestogether, painting the pipe, flanges etc with 2 coats of heat resistant paint suitable for outdoorapplications fixing the pipe firmly with fabricated structure/ mechanical support etc as required 150 mmdia |
| 18 | 90.12.2.34:Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 185 sq mm |
| 19 | 90.12.7.34:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm |
| 20 | 9.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm) |
| 21 | 90.12.2.31:Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 95 sq mm |
| 22 | 9.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm) |
| 23 | 90.12.9.13:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench200/174 mm or nearest size |
| 24 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 25 | 90.16.4.8:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm copper strip |
| 26 | 90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip |
| 27 | 90.16.3.10:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 6 mm copper strip |
| 28 | 90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm |
| 29 | OD507614/2025-2026:Supply and fixing Danger notice board of size, 125 x 75 mm |
| 30 | OD507611/2025-2026:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clearvision. |
| 31 | OD507616/2025-2026:Supply and providing of ABC type fireextinguisher 6kg capacity consisting of M.S cylindrical body,squeeze lever discharge valvefitted withpressure indicatinggaugeinternal discharge tube, 30cm long high pressure dischargehose, nozzle etc. with installation brackets confirming to IS 15683 as required |
| 32 | OD507617/2025-2026:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat ofredoxide and written with white paint 'FIRE', filled with fine sand, mounted on existing MS angle frame work / wall bracket etc. as required |
| 33 | OD507612/2025-2026:Supply of HSD for testing of the DG set including loading at the fuelpump,conveyance,unloading atsite,filling in the tank etc |
| 34 | OD507613/2025-2026:Supply and providing 2.5mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 towithstand 11 KV dielectric strength including fixing with suitable synthetic adhesive, |
| 35 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 36 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 37 | OD507615/2025-2026:steel reinforcement for RCC work including straightening, cutting , bending, placing in position and binding all complete upto plinth level. |
| 38 | 14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels. |
| 39 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 40 | OD507618/2025-2026:Copying charges of Electrical/fire Drawing per A3 sheet additional copies |
| 41 | OD507610/2025-2026:Charges for preparation of Electrical/fire Drawing per A3 sheet first copy |
| 42 | OD3741/2026-2027:Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.7 X2.5 sq.mm |
| 43 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 44 | 4.1.4:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 45 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 46 | 90.16.3.3:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 6 mm GI strip Please Enable Macros to View BoQ information |