| 1 | Painting Old Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) (sl.no-376) |
| 2 | Painting Old iron works such as steel doors, windows, ventilators, window bars, etc., with Two coats of best approved first quality and colour of synthetic balustradesenamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) (sl.no 371) |
| 3 | Supply and laying of following sizes of Armoured Aluminium Cables for electrical motor, control panel, pressure switch, jockey motor etc., The rate inclusive of all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the Departmental Officers4 core 16 sq.mm armoured aluminium cable (SL.NO 326 M-0761) |
| 4 | Supply and fixing of single box type 4'20W fluorescent fitting complete with electronic ballast with TW round blocks an wall or ceiling with flu tube with PVC unsheathed FRLS Copper leads from terminals to the fitting (PWD SOR, M-1273, Pg.no-213) |
| 5 | Supply and fixing of 1200mm (48\\") sweep AC ceiling fan complete with stepped electronic 300W regulator with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18\\") (PWDSOR, M-1333,Pg.no-216) |
| 6 | Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers.(sl.no 333. M-0773) |
| 7 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with \\"P\\" or \\"S\\" trap conforming to BIS with crushed stone sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall /reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use (sl.no-656) |
| 8 | Dismantling the existing damaged Plain Cement Concrete including Loading, Unloading and Conveyance with a lead of 2km all other charges etc to complete PWD SOR Pg.no-30 (W-0034) |
| 9 | Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.-Mixing by mechanical means (SL.NO-135) |
| 10 | Construction of INSPECTION CHAMBER following diear sizes including earth work excavation, CIC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand) using best quality of Clay bumt Bricks of size 9\\" x 43/8\\" x 23/4\\" with Class designation of 7.5 and Plasteris with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate) 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental offficers as per standard specification (code-683) |
| 11 | Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter PWD SOR (Pg.no-84) |
| 12 | Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 over a cement mortar bed of 20mm thick in Cement Mortar 1:3 (One Cement and Three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) (sl.no-258) |
| 13 | Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) (sl.no-260) |
| 14 | Supply, delivery and fixing of 25lit Capacity RO Unit Including cost of all materials labour charges etc, complete |
| 15 | Supply, delivery and fixing of Fly catcher Including cost of all materials labour charges etc, complete ` Please Enable Macros to View BoQ information |