| 1 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floorV level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) |
| 2 | 12 mm cement plaster of mix 13.1.1 1:4 (1 cement: 4 fine sand) |
| 3 | 15 mm cement plaster on the rough side of single or half brick wall ofmix :13.2.1 1:4 (1 cement: 4 fine sand) |
| 4 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc. |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources). |
| 7 | Centering and shuttering including strutting, propping etc. and removalof form for 5.9.5 Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 8 | Supplying and fixing rolling shutters of approved make, made of requiredsize M.S. laths, interlocked together through their entire length andjointed together at the end by end locks, mounted on specially designedpipe shaft with brackets, side guides and arrangements for inside andoutside locking with push and pull operation complete, including thecost of providing and fixing necessary 27.5 cm long wire springsmanufactured from high tensile steel wire of adequate strengthconforming to IS: 4454 - part 1 and M.S. top cover of required thicknessfor rolling shutters.10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 9 | Providing wood work in frames of false ceiling, partitions etc. sawn andfixed in position with necessary stainless steel screws etc.9.3.2 Kiln seasoned and chemically treated hollock wood |
| 10 | Providing corrugated G.S. sheet roofing including vertical / curvedsurface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead, including a coat of approved steelprimer and two coats of approved paint on overlapping of sheetscomplete (up to any pitch in horizontal/ vertical or curved surfaces),excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required.12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m² |
| 11 | Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface :13.43.1Water thinnable cement primer |
| 12 | Finishing walls with water proofing cement paint of required shade :13.44.1New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 13 | Finishing with Epoxy paint (two or more coats) at all locations preparedand applied as per manufacturer's specifications including appropriatepriming coat, preparation of surface, etc. complete.13.52.1 On steel work |
| 14 | Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.12.41.2 110 mm diameter |
| 15 | Add. For Electrification (9 % of Civil Work) Rs.317123.00 (This amount not to be changed by the Bidders in BOQ) Please Enable Macros to View BoQ information |