| 1 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 2 | Dismantling Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 3 | Dismantling timber scantlings 40 Sqcm and over in any position in framed work complete all as specified and directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 5 | S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe-290 (Gde E-165) complete all as specified and directed. |
| 6 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 or other cuting plates complete all as specified and directed. |
| 7 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 8 | All as per above item here-in - before but except sheeting complete all as specified and as directed. |
| 9 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 10 | M&L 6 mm thick asbestos cement, corrugated or semi corrugated sheets in roof, walls etc fixed with L- type or J-type or cranked hook bolts etc complete all as specified and directed by Engineer-in-Charge. |
| 11 | All as per Sl item No. 10.00 above but exept sheet complete all as specified and directed. |
| 12 | M & L Asbestos cement two piece adjustable plain wing ridge 6 mm thick fixed with 'J' type hook bolts etc complete all as specified and directed. |
| 13 | M&L 2nd class hard wood scantling clean sawn, timber fixed for purlins, posts, rafters etc complete all as specified and directed. |
| 14 | Dismantling wall and ceiling boards (fibre,pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillets. |
| 15 | M&L for providing aluminium snap Grid frame work for false ceiling with of size 605X605 mm ,using Main and cross tee of size 36.5mmX25mmX1.4mm,weighing 0.24 kg/RM and 23.5mmX26.4mmX1.4mm weighing 0.191Kg/RM respectively. the snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40mmX25mmX2mm weighing 0.36Kg/RM. The snap grid shall be fixed to ceiling supporting hangers consisting of 2mm dia MS wire/GI wire, J bolts, nuts and washers as per manufacturer's instruction complete all as specified and directed. |
| 16 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. |
| 17 | M&L for providing and fixing gypsum board 10 mm, thick in ceiling fixed with screws as per manufacturer instruction complete all as specified and directed. |
| 18 | M&L for 4 mm thick non Asbestos fibre cement designer building boards , fixed in celling flat or sloping laid/inserted to timber/GI/Aluminium framework with screws complete all as specified and directed |
| 19 | M&L for preparation of new ceiling surfaces and applying two coat of oil bound distemper complete all as specified and as directed. |
| 20 | Dismantling of boarding, any description, fixed in any position with nail |
| 21 | M&L for second class hardwood Weather boarding,clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps complete all as specified and directed. |
| 22 | Fixing only sencond class hardwood Weather boarding,clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps complete all as specified and directed. |
| 23 | M&L Preparing new surfaces of wood of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 24 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on newly untreated surfaces of steel over 10cm in width or girth not otherwise described complete all as specified and directed. |
| 25 | Dismantling old brocken floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premices complete all as specified and directed. |
| 26 | Demolition of plain cement concrete in ground floor and paving not exceeding 15cm thickness below or above ground level complete all as specified and directed. |
| 27 | M&L coloured ceramic glazed tiles 375x250x7mm/ 450x300x7mm thick as in dado/skirting etc including 10 mm thick rendering in CM 1:4, set & jointed in neat cement slurry & pointed in white or coloured cement slurry & pointed in white or coloured cement complete all as specified and directed. |
| 28 | M&L for joint free non skid coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc over & including 15mm thick screed bed in CM 1:4, set & jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed. |
| 29 | M/L for PCC (1:5:10) type E2 using 40mm graded brick aggregate as in sunken portion complete all as specified and directed. |
| 30 | Taking up or down steel tubing and connection of 15 mm bore complete all as specified and directed. |
| 31 | All as per item. Sl No 30.00 above but for 20 mm dia bore pipe. |
| 32 | Supplying and laying of CPVC pipes of outer dia 20mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 33 | All as per item. Sl No 32.00 above but 25 mm dia |
| 34 | Disconnecting existing water tanks of capacity exceeding 250 Ltr but not exceeding 500 Ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and as directed. |
| 35 | Disconnecting existing water tanks of capacity exceeding 500 Ltr but not exceeding 1000 Ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and as directed. |
| 36 | S&F in repair 500 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I, screwed for iron/cpvc pipe and fixed complete all as specified and as directed. |
| 37 | S&F in repair 1000 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I, screwed for iron/cpvc pipe and fixed complete all as specified and as directed. |
| 38 | S&F 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron/cpvc pipe and fixed. (Minimum weight-210gms) complete all as specified and as directed. |
| 39 | S&F 25mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight--455gms) complete all as specified and as directed. |
| 40 | S&F in repair for 10 ltrs capacity flushing cistern PVC low level valve less, symphonic action type flushing cistern white with inlet, ball valve, float and handle including brackets and 32 mm flush pipe of polyethylene complete all as specified and directed. |
| 41 | S & F in repair for PVC connection pipe of 15 mm dia and 45 cm long to WHB and flushing cistern complete all as specified and directed. |
| 42 | S&F in repair 15mm dia angle stop valves cast copper alloy fancy type,chromium plated complete all as specified and directed |
| 43 | S&F in repair for Gun-metal, globe or gate valves 20mm, with iron wheel head, screwed both ends for iron pipe etc complete all as specified and directed . |
| 44 | S & F in repair, 15mm bore bib taps cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed |
| 45 | S & F in repair, 15mm bore stop valve cast copper alloy, fancy type chromium plated with long shank and cup (concealed) screwed down,high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed. |
| 46 | S&F in repairs for shower rose chromium plated with or without swivel joints 125 mm dia complete all as specified and directed |
| 47 | S&F in repair vitrious china wash basin, white flat back size 550 x 400 mm including waste, chain & plug and poreclain stopper and bracket etc. Complete including cutting for and pinning in ends of brackets or errecting bracket and 32mm dia waste fitting brass chromium plated for WHB etc;with long screwed shanks and fly nuts,flange end bedded in red lead cement including 32mm dia waste pipe fitted complete all as specified and directed |
| 48 | S&F in repair vitreous china squatting pan ORRISA Pattern of size 580x 440mm white with integral foot rest complete (excluding cistern and flush pipe) including connection to trap and to flushing pipe, anti-syphonage pipe, etc including making good to floor complete all as specified and as directed. |
| 49 | S&F in repair Vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolt, flushing cistern and flush pipe) but including P or S trap, sheet cover of white colour complete all as specified and directed. |
| 50 | S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections complete all as specified and as directed. |
| 51 | S&F in repairs 15mm dia pillar tap cost copper alloy fancy type with capstan heads chromium plated screwed down high pressure with or without letered \\"Hot or Cold\\" high pressure with long screwed shanks & fly nuts screwed for iron pipe etc complete all as specified and directed |
| 52 | Supply and fix in repair shelf 450mm long of PTMT fixed with and incl chromium plated brass screws and wooden /plastic cleats (minimum weight 300 grams) complete all as specified and as directed. |
| 53 | S&F in repair CP towel rail, 20mm dia, D type,60cm long complete all as approved and directed by the Engineer-in-Charge. |
| 54 | Taking down cement plaster on brick wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 55 | Demolition of brick work built in cement mortar. |
| 56 | M&L brick work with sub class 'B' brick straight or curved on plan exc 6m means radius build in cement mortar 1:6 complete all as specified and as directed. |
| 57 | M & L for rendering 10 mm thick on fair faces of bricks/concrete surface in cement mortar (1:6) on wall finishing the surfaces even and fair without using extra cement complete all as specified and as directed. |
| 58 | M & L for rendering 15 mm thick in two separate coats (10mm thick backing coat and 5mm thick finishing coat) on fair faces of bricks/concrete surface in cement mortar (1:4) with using WPC at finishing coat (WPC shall be measured seperately)on wall finishing the surfaces even and fair without using extra cement complete all as specified and as directed. |
| 59 | M&L for 5 mm thick cement plaster in cement mortar 1:3 for ceiling, finished even & smooth without using extra cement complete all as specified and directed. |
| 60 | M&L for preparation of newly plastered surface and applying two coat of oil bound distemper over a coat of alkali resistant primer including a coat of wall care putty complete all as specified and as directed. |
| 61 | M&L for preparation of newly plastered surface of ceiling and applying two coat of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed. |
| 62 | M&L for preparation of newly plastered surface and applying two coat of Acrylic Smooth exterior paint of required shade (Camouflage) over and including priming coat of exterior primer complete all as per manufacturer instruction. |
| 63 | Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittins,heads,shoes,bends,swan-necks,etc including removing from site |
| 64 | M&L for 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified and directed. |
| 65 | M&L for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified and directed. |
| 66 | S&F PVC (SWR) bends 110 mm bore of any radius complete all as specified and directed. |
| 67 | S&F PVC (SWR) bends 75 mm bore of any radius all as specified & directed. |
| 68 | S&F PVC (SWR) junction single (singleT) equal or unequal 110mm bore provided with access door complete all as specified and directed. |
| 69 | S&F 110 mm bore PVC (SWR) vent cowl. |
| 70 | S&F 75 mm dia outlet PVC (SWR) floor trap plain with steel grating including jointing with solvent cement. |
| 71 | S&F 110mm dia PVC (SWR)WC connector with lip ring |
| 72 | Taking down complete existing treatment of roof/ parapet , Mud puska on roof /parrapet including plastering, brick tiles, stone slabs and leeping any thickness including removal etc complete all as specified and directed. |
| 73 | M&L Brushing neat cement slurry (3 Kg of cement per Sq M) mixed with water proofing liquid in the proportion,water proofing liquid, water & cement (1:4:7) or as per manufacture instructions for bonding of old concrete surface to new concrete complete all as specified and directed. |
| 74 | M&L PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) mixed with integral waterproofing chemical compound mixed in proportion 200 millilitre per 50 Kg cement as in padding, benching,Sunken portion etc on roof surface for corecting/making proper slope on roof, etc complete all as specified and directed. |
| 75 | M & L cutting 75 mm wide and 65 mm deep in brick wall / PCC block / RCC surface any location shaping horizontal face grooves filled with PCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate with and including water proofing chemical compound mixed in proportion 200 millilitre per 50 Kg cement or as per manufacturers instructions laid when concrete is still green complete all as specified and directed. |
| 76 | M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed. |
| 77 | M&L Rendering 15 mm thick in cement mortar 1:4 on concrete / brick surfaces with liquid water proofing compound @ 200 ml/50 kg per bag of cement or as per manufacturar instruction finished even and smooth without using extra cement over roof / sunken slab /wall complete all as specified and directed. NOTE : water proofing liquid will be measured and paid seperately . |
| 78 | M&L for Water proofing treatment on \\"Non approachable / non accessible roof\\" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer all as specified and directed complete |
| 79 | (i) Applying approved cold bituminous primer conforming to IS : 3384-1986 @ 0.25kg/Sqm to be applied on top surface of prepared surface till the surface is properly impregnated. |
| 80 | (ii) Laying APP (Atactic polypropylene Polymer Modified preffabricated membrane) waterr proofing membrane of weight not less than 3 kg/sqm with minimum 100mm side overlap along the length from downward to upward completely sealed with torch application/hot blown lamps. |
| 81 | (iii) Applying one coat of bituminous based aluminium paint @ 0.11 kg/Sqm complete all as specified and as directed. |
| 82 | Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqm in sunken portion including cleaning of surfaces complete all as specified and directed. |
| 83 | Supply only water proofing compound (liquid),ISI marked. |
| 84 | S&F 50mm bore tubes light grade galvanised with all fittings laid in floor as in spout pipe, etc complete all as specified and directed. Please Enable Macros to View BoQ information |