Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling , ramming the foundation trenches, removing roots of trees, serbs all complete as per approved design,building specification & direction of E/I. |
| 2 | Extra for earthwork in hard soil as per specification and direction of E /l (vide classification of soil item-B) hard soil @ 80% of tatal Excavation |
| 3 | Excavation in Ordinary Rock with Dozer with lead upto 100 metres (Excavation for roadway inordinary rock by deploying a dozer,80HP including cutting and pushing the cut earth to site of embankment up to a distance of 100 metres (averagelead50metres) ,trimming bottom and side slopes in accordance with the requirements of lines, grades and cross sections.) |
| 4 | Providing coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) Sand filling in Foundation, Flooring and Below Tai Beam |
| 5 | Providing designation 75A one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I |
| 6 | Providing And Fixing in position cement concrete of specified grade excluding the coast of centering and shuttring -All work up to plinth level . 1:2:4 (1 cement :2 coarse sand(Zone-III):4 graded stone aggregate 40mm nominal size) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 8 | EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 9 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 Sqm. On plan including disposal of excavted earth upto 50m and lift upto 1.5 m disposal soil to be levelled and neatly dressed: |
| 10 | Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level 1:1.5:3 (1 cement :1.50 coarse sand (Zone-III):3 graded stone aggregate 20mm nominal size) |
| 11 | Centering and shuttring including,propping etc and removal of from for Foundation,footings below bases of column etc for mass concrete. |
| 12 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement :1.50 coarse sand (Zone-III):3 graded stone aggregate 20mm nominal size) |
| 13 | Centering and shuttring including,propping etc and removal of from for Columns.Pillars,Piers,Abutments,Posts And Struts |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 15 | Centering and shuttring including,propping etc and removal of from for lintel,beams,plinth beam,girders,bressumers and cantilevers |
| 16 | Centering and shuttring cluding,propping etc and removal of from for Suspended floors,roofs,landigs,balconyes,and acess platform |
| 17 | Centering and shuttring incuding,propping etc and removal of from for Stairs,(excluding landings)excepts spiral staircases |
| 18 | Centering and shuttring incuding,propping etc and removal of from for Weather shade, Chajjas, corbels etc., including edges |
| 19 | Providing TMT reinforcement of following dia rods as per approved design and drawing including carriage of M.S. rods of (Straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I. TMTC-500 8mm dia |
| 20 | Providing tor steel reinforcement rods as per approved design --do-- tht fe 500(only valid for tata(tiscon),sail, jspl,electeo steel, ltd.bokaro and vizag (RINL) |
| 21 | TMTC-500 10mm dia |
| 22 | TMTC-500 12mm dia |
| 23 | TMTC Fe-500 16mm dia |
| 24 | TMTC Fe-500 20/25mm dia |
| 25 | Water proofing for old and new roof slab:- providing and laying water proofing treatment on roof slab by appling two component,factory designed ready to use acrylic modified flexible materials applied with … |
| 26 | Covering of treated surface with PCC :- Providing 25 mm thick Cement Concrete M20(1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm |
| 27 | Providing and filling of 6 mm thickGroove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade)as per drawings and technical specifications and direction of E in Charge.(with 18% |
| 28 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mmdia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing. |
| 29 | Providing designation 75 A brick work in C.M. (1:4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 30 | Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 31 | Providing designation 75B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening maerials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 32 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 33 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 34 | Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I. |
| 35 | Providing designation 75A brick work in CM (1:6) in superstructure with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 36 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I (Cost of Cico will be paid separately) |
| 37 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia |
| 38 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 39 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 40 | Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete. 150 MM dia R.C.C. pipe |
| 41 | Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg |
| 42 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. (a) From 0.00 M to 50.00 M below G.L. |
| 43 | Providing 125mm thick reinforced designation 75A brickwork in C.M. (1:4) in Superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 44 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I |
| 45 | Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I. |
| 46 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/l. |
| 47 | Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 48 | Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush door shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.. |
| 49 | Suppling, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows, skylight, fanlights and celetial windows openings, including wedge over clamps all complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all complete as per building specification and direction of E/l |
| 50 | Supplying, fitting and fixing 35mm thick solid core type non-decorative double leaf flush shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 51 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 52 | Providing and fixing PVC rigid foam sheet 1 mm thick on existingdoor shutters |
| 53 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/clerestory windows & desertory other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulusof elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus sideshall be acceptable but no extra payment on this account shall be made. |
| 54 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/ mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) |
| 55 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) Powder coated aluminium (minimumthickness of powder coating 50 micron |
| 56 | Providing and fixing reflective glazing in windows with 5mm thick of ST-167-sparkling Ice/ or Equevalant with EPDM rubber / neoprene gasket etc. all cost complete as per architectural drawing and the direction of E/I |
| 57 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2 mm at 100mm. centres and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40x40x6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage , hoisting and taxes all complete as per building specification and direction of E/l. |
| 58 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 59 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.) |
| 60 | Supplying, fitting and fixing 20 guage G.C.I, sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l. |
| 61 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 62 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws win rubber stopper |
| 63 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. |
| 64 | Providing and laying doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 65 | Providing and laying vitrified floor tiles for step of stair in with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete step tiles & have bullnose, Anti and self embossed line. Size of Tile 1200x300 mmx15 mm |
| 66 | Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur green marble |
| 67 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. |
| 68 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. With commercial grade colour 15X15cm Tiles. |
| 69 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 70 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 71 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l Wall area Where false ceiling done. |
| 72 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 73 | Providing & Applying high quality acrylic modified resin based textureof Dholpur/Red sand stone Pattern with anti algae and UV resistanceproperties to be applied as intermediate finish in desired pattern @ 43.04 kg/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litre/10 sqm, complete as the direction of Engineer -in-Charge |
| 74 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 75 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 76 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing rust , dirt, , scales , smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/l. ( Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification) |
| 77 | Supplying, fitting and fixing fully glazed steel door, windows or ventilations of standard rolled 'Z' and mullion steel sections and size as per IS-1038 joints met and welded with 100x16x3mm M.S. lugs fixed in cement concrete (1:2:4) blocks 15x10x10 cm size including cost of oxidised iron fittings, with hinges, handle per steps, catch springs, 3mm thick plain glass panes with Aluminimum beads and inner frame fixed with lugs with 20mm long 6.3mm G.I. counter sunk machine screw and nuts and applying a coat of red lead paint carriage to work site hoisting and placing in position in all storys and taxes all complete as per building specification and direction of E/l. |
| 78 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment) |
| 79 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. |
| 80 | Providing & fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion. Single socketed pipes. 110mm dia |
| 81 | Providing & fixing on wall face unplasticised- PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion |
| 82 | Bend -110 mm |
| 83 | Shoe - 110mm |
| 84 | Providing and fixing unplasticised - PVC pipe clips of approved design to inplasticised - PVC rain water pipes by means of 50 x 50 x 50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 85 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 86 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge |
| 87 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 88 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. |
| 89 | 53 mm to 22.4 mm size stone aggreate |
| 90 | Moorum |
| 91 | Laying, spreading and compacting stone aggreate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggreate, watering and compacting to the required density. |
| 92 | Chequerred precast cement concrete tiles 22 mm thick in footpath &courtyard, jointed with neat cement slurry mixed with pigment to matchthe shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand |
| 93 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 94 | Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 95 | Providing and fixing fly proof stainless steel grade 304 wire gauge, towindows and clerestory windows using wire gauge with average widthof aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete With 12 mm mild steel U beading |
| 96 | Supply fitting and fixing 20mm thick solid core type non decorative double leaf flush shutters in cup borads with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneered of stadard make with oxidesed iron fittings -do- |
| 97 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conformingto IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge over 20 mm thick layer of cement mortar of mix 1:5(1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of After two days of proper curing applying a second coat ofcement slurry using 2.75 kg/ sqm of cement admixed withwater proofing compound conforming to IS : 2645 andapproved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortarof mix 1:4 (1 cement :4 coarse sand) admixed with waterproofing compound conforming to IS : 2645 and approved byEngineer-in-charge including laying glass fibre cloth ofapproved quality in top layer of plaster and finally finishingthe surface with trowel with neat cement slurry and makingpattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for aminimum period of two weeks for curing and for final test.“Allabove operations to be done in order and as directed andspecified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimumthickness at khurra as 65 mm. |
| 98 | Crack filler Paste -non cementious materials - CP706 / Crack Seal Paste Providing and Pasting Superfil CP -706 / Crackseal Paste or equivalent chemical in cracks |
| 99 | Providing and fixing precoated galvanished iron profile sheets (sioze, shape and pitcj of corrugation, as approved by engineer-in-charge) 0.50mm (+0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS : 277, in 240 mpa steel grade, 5-7 mincrons epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transporation and should be supplied in single length upto 12 metre or as desired by engineer-in-charge. The sheet shall be fixed using self drilling/ self tapping screws of size (5.5 x 55 mm) with EPDM seal, complete upto any pitch in horizontal / vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 100 | Providing and fixingprecoated galvanished steel roofing accessories 0.50 mm (+ 0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS : 277, in 240 mpa steel grade., 5-7 micorns epoxy primer on both side of the sheet and polyester top coat 15-18 micorns using self drilling/ self tapping screws complete : |
| 101 | Ridges Plain (500-600mm) |
| 102 | Gutter |
| 103 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. '@ 35KG PER SQ M Truss |
| 104 | M.S PLATE 12 MM |
| 105 | Supplying, fitting & fixing 20 mm dia M.S. bar 1 meter long holding down bolt with nuts washers 100 x 100 x 6 mm plate fitted and fixed with cement concrete (1:2:3) as per approved design all complete as er building specification and direction of E/I. |
| 106 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long |
| 107 | G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitablyfixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 108 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making |
| 109 | opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per pecifications, drawings and as directed by Engineer-in-Charge. |
| 110 | Supplying & Fixing C.I. Cover without frame -do-do- all complete job |
| 111 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm Square Bar |
| 112 | Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : |
| 113 | Making soak pit 2.5 m diameter3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 114 | Supplying materials and labours for constructing inspection chamber of designation class 75 B bricks size 750 mm deep, 600 x 450 internal dimension having 250 mm wall thickness in cement mortar ( 1:6 ) including 12 mm cement plaster ( 1:4 ) with punning on inside and cement plaster (1:6) with 600 x 475 mm G.I. cover with frame (Weight not less than 36 Kg.) in foundation and refilling all complete as per specification and direction of E/l. |
| 115 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. |
| 116 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with openjoints) for linear as well as curvilinear portions of the building for all heights and all levels, including: |
| 117 | Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (thesystem must passed the proof test at 1.5 times design wind pressure without any failure), ncluding functional design of the aluminum sections for fixing glazing panels of variousthicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structuraland weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure qualisation & drainage and protectionagainst fire hazard including: |
| 118 | Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sectionsand profiles etc. to accommodate 3 Dimentional movementfor achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel frameworkof building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nutsand washers etc. of stainless steel grade 316, of the required capacity and in required numbers. |
| 119 | Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a cleanand controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approvedsealant design, within and all around the perimeter for holdingglass. |
| 120 | Front Side |
| 121 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. |
| 122 | Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with \\"p\\" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. E.W.C With \\"S\\" trap (b)10 lit. low level P.V.C. cistern |
| 123 | Providing and laying 25 mm thick kotah stone tiles in risers of steps, skirting and pillars of approved size, texture and colour laid over 12mm thick cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 124 | Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry hindustan or any other ISS approved make with 100mm HCI p trap 15 litres CI pull and let go flushing cistern of names or other ISS equivalent make complete with all fittings CI or C C bracket 32mm alkethene / PVC telescopic flush pipe about 2m long with one brass coupling and clamps GI chain and pull including supplying and fixing a pair of vitreous white glazed earthenware footrest to be fixed in floor 15mm CI body brass spindle stop cock of weight not less than 50 grames 15mm PVC connection pipe 450mm long and coat of red oxide primer etc all complete as per specification and direction of E/I. (C) 450 mm long (b) with 12.5 litre low level PVC cistern |
| 125 | Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry hindustan or any other ISS approved make with 100mm HCI p trap 15 litres CI pull and let go flushing cistern of names or other ISS equivalent make complete with all fittings CI or C C bracket 32mm alkethene / PVC telescopic flush pipe about 2m long with one brass coupling and clamps GI chain and pull including supplying and fixing a pair of vitreous white glazed earthenware footrest to be fixed in floor 15mm CI body brass spindle stop cock of weight not less than 50 grames 15mm PVC connection pipe 450mm long and coat of red oxide primer etc all complete as per specification and direction of E/I. (A) 580 mm long (b) with 12.5 litre low level PVC cistern |
| 126 | supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or hindustan or any other I.S.S approved make supported on painted C.I OR R.S bracket 32mm C.I brass waste 15mm dia C.I body brass spindle stop cock of approved quality of weight not less than 350 grames, 32mm PVC wate pipe 750mm long with brass coupling with one end and making plumber joints etc.all complete as per specification and direction of E/I. |
| 127 | Providing & fixing stainless steel jali (grating) with hole for waste pipe for floor / nahani trap. 100 mm dia. Weight not less than 100 gms. |
| 128 | Supplying, fitting and fixing gun metal full way valve of approved quality all complete as per specifcation and direction of E/I. |
| 129 | 15mm dia. |
| 130 | 20mm dia. |
| 131 | 25mm dia |
| 132 | 32mm dia |
| 133 | 40 mm dia |
| 134 | Providing and fixing brass stop cock of approved quality all complete as per specification and direction of E/I. … 15mm dia. |
| 135 | Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. |
| 136 | Pillar cock (long neck) |
| 137 | Bib cock - long thread |
| 138 | Angular stop cock L.T. |
| 139 | Glass shelf |
| 140 | 4 way diverter for concealed fittings |
| 141 | Flush valve complete with 32mm size control cock & flange |
| 142 | 32mm dia. PVC waste pipe 750mm long with cushion |
| 143 | 15mm C.P. nipple with coupling |
| 144 | Providing Solvent cement |
| 145 | Supplying, fitting and fixing Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror. 600 X 450mm |
| 146 | Supplying, fitting and fixing C.P. brass towel rail 20mm X 600mm with bracket container |
| 147 | Supplying, fitting and fixing C.P. brass Rail(ii) 450mmx125mm glass shelf complete. |
| 148 | Supplying, fitting and fixing C.P. brass soap dish container medium quality with screw and hinges etc. |
| 149 | Providing and fixing 15mm dia and 45cm long PVC connection pipe with heavy quality brass coupling at both ends etc all complete as per specification and direction of engineer in charge |
| 150 | Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthenware urinal of \\"Hindustan\\" \\" Parry\\" or any other approved I.S.S. make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15 mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grms. , 15 mm P.V.C. alkathene pipe 450 mm long with brass coupling at both ends and doing plumber joints including painting of exposed part with 2 coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/l. (A) Flat back or standing corner ( 600 mm x 350 mm ) |
| 151 | Supplying, fitting and fixing viterous white glazed earthen ware indian squating type 600 x 350 mm urinal plate of Parry Hindustan or any other I.S.S. approved make with internal flushing rim 100 mm white glazed earthen ware channel about 1m long 5litre capacity C.I. automatic flushing cistern of reliance or any other approved make with fittings C.I. or R.S. brackets 15 mm & 45 cm long P.V.C. alkathene pipe standard G.I. flush pipe for back and front with spreader fitting and brass coupling etc. 15mm C.I. body brass spindle stop cock weight not less than 450 grms. all complete including painting of exposed part with 2 coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/l. (A) 600 mm x 350 mm size ( large ) |
| 152 | Providing and fixing PTMT extension nipple 15mm size with 12\\" BSP thread 70mm length and 30mm breadth and weighing not less than 32gms of approved make |
| 153 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS 8931, 15mm dia nominal bore of approved brand C.P. fittings |
| 154 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i.e fixing the pipe with clamps at 1Mtr. Spacing. This includes jointing of the pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. Concealed work including cutting chases and making good the walls etc. |
| 155 | 20mm nominal bore |
| 156 | 25mm nominal bore |
| 157 | 32mm nominal bore |
| 158 | External work - 40mm nominal bore |
| 159 | Providing & fixing on wall face unplasticised - Rigid P.V.C. pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia |
| 160 | Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 161 | Single Tee with door |
| 162 | 110x110x110 ,mm |
| 163 | 110 mm bend |
| 164 | Supplying and fixing PVC fittings of approved make confirming to IS : 1729 including supplying nails and bobbins, fixing solutions including earth work or masonary work cutting and remaking and providilding as the case may be all complete as per specification and direction of E/I. |
| 165 | PVC cowl - 100mm dia. |
| 166 | Floor trap - 100mm dia. |
| 167 | Ring rubber |
| 168 | Door piece |
| 169 | Kitchen sink 600 mm x 450 mm x 250 mm (24\\" x 18\\" x 10\\")(lSl Marked) |
| 170 | Providing and placing on terrace (at all floor levels) (PVC) Polyethylene water storage tank ISI 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 171 | Point Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required. |
| 172 | Group-C |
| 173 | Group-B |
| 174 | Group-A |
| 175 | Twin Control Point Wiring in PVC Conduit, with Modular type Switch: Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch, modular plate, suitable size of GI box etc as required. |
| 176 | Power Plug wiring in PVC Conduit (2X4 Sq.mm) :- Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated copper conductor songle core cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc. as required. |
| 177 | Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 178 | 2x1.5 Sqmm + 1x1.5 sq.mm earth wire(for Single Separate 5A socket from nearest switch board) |
| 179 | 2x2.5 Sqmm + 1x2.5 sqmm earth wire (for switch board circuit). |
| 180 | 2x4 Sqmm + 1x4 sq mm earth wire |
| 181 | 2x6 Sq.mm + 1x6 Sq.mm earth wire. |
| 182 | 4 x 4 sq. mm + 2 x 4 sq. mm earth wire (Lighting DB) |
| 183 | 4x6 Sq.mm + 2x6 Sq.mm earth wire. ( to be used as main for Light TPN DB.) |
| 184 | 4x10 Sq.mm + 2x10 Sq.mm earth wire. ( to be used as main for Power TPN DB.) |
| 185 | 4x16 Sq.mm + 2x16 Sq.mm earth wire. |
| 186 | Telephone Wiring in Existing Conduit:- Supplying and drawing, following pair, 0.5 sq.mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface / recessed steel / PVC conduit as required. 2 pair |
| 187 | TV cable in Existing Conduit:- Supplying and drawing, co-axial TV cable RG-6 grade copper conductor, PE insulated with PVC sheath in the existing surface/ recessed steel / PVC conduit as required. |
| 188 | S/F PVC Conduit: Supplying and fixing of following sizes of Rigid 2 mm thick PVC conduit alongwith the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required for TV and TEL out lets. |
| 189 | 20 mm |
| 190 | 25 mm |
| 191 | 32 mm |
| 192 | S/F Modular type Switch / Socket:- Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc as required. (to be used in switch board with sockets) |
| 193 | 5/6 amps, one way modular switch |
| 194 | 5/ 6 amps, two way switch |
| 195 | l5/ 16 amps, one way switch |
| 196 | 5/6 amps, 3 pin modular socket |
| 197 | Telephone Socket Out let |
| 198 | TV antenna socket outlet |
| 199 | S/F Modular type electronic fan regulator:- Supplying and fixing stepped (two module) type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. |
| 200 | S/F Modular blanking plate:- Supplying and fixing of the existing modular plate and switch box excluding modular plate etc, as required. |
| 201 | Supplying and fixing following size /modules G.I. box along with modular base and cover plate for modular switches in recess etc. as required |
| 202 | 1 or 2 modules (78mmx78mmx45mm) |
| 203 | 6 modules (78mmx140mmx50mm) (to use 2 No. 5/6A sockets & 2 no. 6 A Switch) |
| 204 | 8/9 module (78mm x 230mm x 60mm) |
| 205 | l2 module (l35mm x 205mm x 60mm) |
| 206 | S/F light plug point with modular type accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 5 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required. |
| 207 | S/F power plug point with modular type accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required. |
| 208 | S/F Ceiling Rose:- Supplying and fixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 209 | S/F Batten / Angle Holder:- Supplying and fixing batten / angle holder including connection etc as required. |
| 210 | Erection on incandescent light fitting :- Erection of wall bracket/ceiling fittings of all sizes and shapes containing upto two GLS amps per fitting, complete with all accessories including connection etc as required. |
| 211 | S/F Electonic Musical Call Bell:- Supplying and fixing electronic musical call bell suitable for D.C./A.C. single phase, 230Volts, complete etc as required. |
| 212 | ITC fluorescent fitting directly on surface:- Installation, testing and commissioning of Pre-wired fluorescent fitting /compact fluorescent fitting of all types, complete with all accessories and tube etc.directly on surace or ceiling/ wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 213 | ITC Ceiling Fan :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm. FRPVC insulated,copper conductor,single core cable etc, as required. |
| 214 | ITC Exhaust Fan upto 450 mm sweep:- installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required. |
| 215 | S/F SP MCB DB:- Supplying and fixing following way, SP&N MCB distribution board of sheet steel for 240 Volts on surface /recess complete with tinned copper bus bar, neutral busbar, earth bar, detachable gland plate, interconnections, phophatized and powder coated painted including earthing etc. as required ( But without MCB/RCCB/ ISOLATOR).12 Way Double Door |
| 216 | S/F TP MCB DB: Supplying and fixing following way,three pole and neutral sheet MCB distribution board, 415 volts on surface/recess complete with tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections,phosphatised and powder painted including earthing etc. as required ( But without MCB/RCCB/ ISOLATOR). |
| 217 | 4 Ways (4+12 ways) double door |
| 218 | 6 Ways (4+18 ways) double door |
| 219 | 8 ways (4+24) Double Door. (horizontal type) |
| 220 | S/F rewireable Double/TP & N Switch Disconnector (SFU):- |
| 221 | Providing, fitting, fixing, installing and testing of Switch Fuse Unit of double pole/ TP & N conforming to IS:- 13947-3 of following current rating rewireable porcelain fuse type complete with metal enclosure to be mouned on wall with iron flat 32mmx5mm with G.I. Nut bolts etc. as required and as per the direction of E/I. |
| 222 | 100A TP & N SFU |
| 223 | S/F Bus Bar Chamber |
| 224 | Providing, fitting, fixing, installing and testing of TPN Bus Bar conforming to IS:- 13947-3 of current rating 100 A TPN with 4 Nos. copper bus having capacity of 100A complete with metal enclosure to be mouned on wall with iron strip 32mmx5mm with G.I. Nut bolts etc. as required and as per the direction of E/I. |
| 225 | 100 Amps |
| 226 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel dust protected, duly power painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar mounting MCB's (but without MCB's and Incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 227 | Note : Vertical type MCB TPDB is normally used where three phase outlets are required. |
| 228 | 8 way (8 + 24) Double door, Vertical Type |
| 229 | S/F 'C' series MCB:- Supplying and fixing 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. |
| 230 | 6/32A Single Pole |
| 231 | 40A DP MCB (To use as incomer for all SP MCB DB) |
| 232 | 6/32A TPN (To use as incommer for all TPN D.B.) |
| 233 | 40A TPN/TP MCB (To use as incomer for all LDB TPN DB) |
| 234 | 50/63A TPN (To use as incommer for all TPN D.B.) |
| 235 | P/F MV Danger Notice Plate:- Providing and fixing M.V. danger notice plate of 200mmX150mm, made of mild steel at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in the single red colour on front side as required. |
| 236 | GI Earth Pipe Electrode: Earthing with G.I. earth pipe 4.5 mtr long , 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcol or coke and salt) complete as required. |
| 237 | Earthing with G.I. Earth plate 600mm x 600mm x 6mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal and salt as required). |
| 238 | Earthing with copper plate 600mmx 600mmx 3mm thick including acessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or cock and salt) complete etc. as required. |
| 239 | Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc, as required. |
| 240 | Supplying and laying 25 mm x 5 mm G.I. strip at 0.50 meter below ground as strip earth electrode including connection/termination with G.I. nut, bolt, spring, washer etc, as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) |
| 241 | Providing and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc as required. |
| 242 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15mm dia G.I. pipe from earth electrode, as required.S/L 25mm x 6mm G.I. earth strip in ground :- |
| 243 | Providing and fixing 25mm x 5mm copper strip on surface or in recess for connection etc. as required. |
| 244 | Providing and fixing 25mm x 5mm G.I. strip on surface or in recess for connection etc. as required. |
| 245 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing etc. as required. |
| 246 | Providing and fixing 4.00mm dia copper wire on surface or in recess for loop earthing etc, as required. |
| 247 | P/F G.I. lightning conductor final - Providing and fixing of lightning conductor final, made of 25mm dia 300mm long, G.I. tube, having single prong at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required. |
| 248 | Reverting sweating and soldering of copper/ GI tape ( with other copper GI tape of the finial or any other metallic object) as required |
| 249 | P/F G.I. lightning conductor tape in horizontal run - Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
| 250 | P/F G.I. lightning conductor tape in vertical run - Provding and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
| 251 | P/F Testing joint G.I. lightning conductor - Providing and fixing testing joint, made of 20mm x 3mm thick G.I. strip, 125mm long, with 4 nos. of G.I. bolts, nuts, check nuts and spring washers etc. complete as required. |
| 252 | Earthing with G.I. Earth pipe 4.5 mtr long. 40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal and salt as required). |
| 253 | Building Outer Light (90/100W LED) :- Supply of Street lighting luminaire aerodynamically shaped single piece pressure die-cast Aluminum luminaire with high power LEDs as light source and electronic driver (IP65), along with 90/100W LED Lamp, as Energy saving as per drawing prescribed reflector and heat resistant toughened flat glass cover, with 5ft long 40mm dia G.I. pipe with 3 Nos. of iron clamps , anchor nut bolts with double washers as per direction of E/I or consultant as per drawing prescribed reflector and heat resistant toughened flat glass cover (IP-65) |
| 254 | Supply of surface mounted round circular ceiling light fixture LED 1x15W-P LED control gear box,electronic blast etc. complete in all respect as required and as per the standard cataloge item. |
| 255 | Supply of surface/ pendent mounted with chain Batten type LED 4ft Tube light fitting with Housing & cover made up of CRCA sheet steel. Cover is fixed to the housing by means of 2 Nos. bolt with engineering plastic head along with 1 nos LED tube of 20/22W Each of luminous efficacy of efficacy >110 Lm/W |
| 256 | Supply, Installation, testing and commissioning of following, size ceiling fan 3 Blades confirming to IS : 374 : 2019 including wiring the down rods of standard length (up to 30cm) with 1.5 sq.mm. FR PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as required. |
| 257 | 1200mm (48\\") BLDC 5star rating 32W Ceiling Fan |
| 258 | Supply, fitting and fixing of Special type bulk head fittings complete set with 9W LED. |
| 259 | 15/16W LED type bulb :- Supply and fixing of 15 led bulb in existin Holder Fitting . |
| 260 | LED Batten (20/22W) |
| 261 | Laying of one number PVC insulated and PVC seathed /XLPE power cable of 1.1 KV grade of size not exceeding 35 sq.mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 262 | Laying of one number PVC insulated and PVC seathed /XLPE power cable of 1.1 KV grade of size not exceeding 35 sq.mm but not exceeding 95 sq.mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 263 | Laying of one number PVC insulated and PVC seathed /XLPE power cable of 1.1 KV grade of size not exceeding 95 sq.mm but not exceeding 185 sq.mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 264 | Laying of one number PVC insulated and PVC seathed /XLPE power cable of 1.1 KV grade of size exceeding 185 sq.mm but not exceeding 400 sq.mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 265 | Laying of one number additional PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 35 sq.mm direct in ground in the same trench in one tire horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 266 | Laying of one number additional PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 35 sq.mm but not exceeding 95 sq.mm direct in ground in the same trench in one tire horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 267 | Laying of one number additional PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 95 sq.mm but not exceeding 185 sq.mm direct in ground in the same trench in one tire horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 268 | Laying of one number additional PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 185 sq.mm but not exceeding 400 sq.mm direct in ground in the same trench in one tire horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 269 | SITC of floowing rating LED Street lighting luminarie with pressure die cast housing and toughtened glass cover (IP 66 protection) in existing pole/ pipe for supply voltage 100-270V AC, 50Hz. Luminarie shell be confirm to IS:10322 patr-5/ Section-3 and shell be complete with all neccssary accessories as required. |
| 270 | 90/100W LED Street light |
| 271 | SITC of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughtened glass cover (IP 66 protection) in existing pole/ pipe for supply voltage 100-270V AC, 50Hz. Luminarie shell be confirm to IS:10322 part-5/ Section-5 and shall be complete with all neccssary accessories as required. |
| 272 | 200W LED Flood Light |
| 273 | SITC of floowing rating reccess/ surface mounted LED Round/ square shape Down light luminarie with pressure die cast housing for singal phase supply voltage. Luminarie shall be confirm to IS:10322 part-5/second-2 or IEC:62722 with all neccssary accessories as required. As per the standard cataloge item. |
| 274 | 12W LED Round Down light (Surface) |
| 275 | Supply of surface/ pendent mounted with chain Batten type LED 4ft Tube light fitting with Housing & cover made up of CRCA sheet steel. Cover is fixed to the housing by means of 2 Nos. bolt with engineering plastic head along with 1 nos LED tube of 20/22W Each of luminous efficacy of efficacy >110 Lm/W. |
| 276 | SITC of following rating LED Post top lamp made in die cast aluminium housing with decorative clear/ opal acrylic diffuser on existing pipe including connection with 1.5sq.mm. copper conductor etc all complete as required.As per the standard cataloge item. |
| 277 | 40/45W LED Post top lamp clear |
| 278 | SITC of following rating approved make LED Bollard fitting with rectangular shape of height 600 to 850mm power input 8/9Wall with die cast aluminium housing opel with PC diffuser, IP:65/54 protection, confirming to IS:10322 part 5 etc all complete as required. (excluding plinth charge) |
| 279 | FANS & Exhaust FANSSupply, Installation, testing and commissioning of following, size ceiling fan 3 Blades confirming to IS : 374 : 2019 including wiring the down rods of standard length (up to 30cm) with 1.5 sq.mm. FR PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as required. |
| 280 | 1200mm (48\\") BLDC 5star rating 32W Ceiling Fan |
| 281 | 9/10W LED type bulb :- Supply and fixing of 9/10 W Led bulb in existin Holder Fitting . |
| 282 | Supply of double LED Tube light Fitting made of diacast aluminium housing 2x20W LED Bettle Tube light sritable for surface or suspended mounded suitable for 230V, 50 Hz, single phase supply etc all complete as required, complete with electronic diver and LED etc., including connections with 1.5 Sq. mm FR PVC insulatted copper conductor and earthing the body etc. as requiered. Efficacy is 100 lm/W.temperature (5700K ± 355K. The Average life of 50000 burning hrs @L70 & Lumen maintenance as per L70 (Confirming to I.E.C. 62722)Make:- Havells/Philips/Crompton/Wipro |
| 283 | Supplying and fixing Surface mounted 9/10 Watt CFL / LED type bulk head e comprising of pressure die casr housing with acrylic diffuser (IP65) and complete with integrated electronic driver etc. directly on wall /ceiling including connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc as required. |
| 284 | Supply and Transportation of AC 230/250 Volts, 50Hz,300mm sweep Exahaust Fans including providing nuts- bolts, mounting frame and other required accessories etc. (For toilets) |
| 285 | Supply of surface/ pendent mounted with suspenssion chain Batten type LED Tube light fitting with Housing & cover made up of CRCA sheet steel. Cover is fixed to the housing by means of 2 Nos. bolt with engineering plastic head along with 2 nos LED tube of 20/22W Each of luminous efficacy of efficacy >110 Lm/W. |
| 286 | Supply and Transportation of AC 230/250 Volts, 50Hz,300mm sweep Exahaust Fans including providing nuts- bolts, mounting frame and other required accessories etc. (For toilets) |
| 287 | LT PANEL FOR ACEDEMIC BUILDING : (For G+4 BUILDING) :- Supplying, designing, manufacturing, fitting, fixing, installation, testing and commissioning of LT Panel, fabricated out of 1.6mm thick (16 SWG) CRCA sheet steel IP:43, (dust and vermin proof) with reinforcement of suitable lifting arrangement effecting proper connection of all incomer and outgoing for all DBs , floor mounting type , fixed on base channel of 75mm x 75mm x 6mm, which will have incoming 3 phase power supply from Campus Sub-Station. |
| 288 | The sheet steel shall under go minimum of 7 tank treatment followed by finished powder coating of minimum 60 micron thickness and suitable for operation on 415V / 3 Ph / 50 Cy includes 415V electrolitic Al. bus bar with atleast 3 mm removable gland plate, cable glands including connection with outgoing feeders complete in all respect and should have bottom entry. |
| 289 | The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5/15A socket service outlet (single phase) and 1 no. CFL light with holder shall be provided in one of the compartments as service outlet in the panel. Panel shall be so designed as to have minimum 10% spare feeders/ space. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. |
| 290 | The panel shall be interlocked with switchgear in such a way that no door can be opened when the switch is in ON position.The switch gear shall have mechanical arrangement for interlock defeat.The design of panel shall be such as to offer maximun safety and easey of maintenance. The gap between live part of the Panel shall be minimum 35mm. |
| 291 | The above Panel shall be completed with 3 Nos. LED phase indicating lamps with MCB protection, analogue ammeter, voltmeter, selector switches, CTs etc. as incomer with all interconnections and compartmentalised cubical type for installing meters with hinged and lockable door stand. All opening shall be covered by soft rubber gasket. All wires used for control circuit should be FRLS PVC insulated flexible copper wire of grade 1100V. |
| 292 | The MCCB's shall be Ics = 100% Icu, with rotary handle, spreader links & pad locking arrangement, with trip setting as per load requirement with short circuit & over current protection. The breaking capacity specified is Ics=Icu value. All MCCB's shall be of thermo magnetic category type. |
| 293 | AL. BUS BAR:- The panel includes 415V, 400A, 3Ph, 36KA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) G.I. Earth Bus with removable glands plates, cable glands at sending and receiving ends, including connection with outgoing feeders complete in all respects. The electrolytic Aluminium bus bar of grade 63401 WP as per I:S 5082 of suitable length and insulated by heat shrinkable sleeves Red, yellow, Blue and Black as R Y B & N. The current density of bus bar shall be minimum 0.8 A / sq mm. All inter connections from main Bus Bar to individual MCCB shall be made with 4, 6 & 10 Sq mm FRLS PVC Cu. wire with 35A 4 studs (Brass) treminal block.. |
| 294 | Each feeder shall have individual compartment with name plate with DB Nos., Floor No. and Block No. |
| 295 | Note:- Inspection of LT Panel shall be carried out by Engineering Incharge / Consultant (Eletcrical) at panel builder site and for that, all arragements shall be made by the suppilier on prior information to parrent department. |
| 296 | SLD along with the G.A. drawing of LT Panel will be submitted by the contractor to Engineering Incharge or to the Consultant for approval . The above SLD and G.A. Drawing of Main LT Panel must be based on approved SLD. |
| 297 | Selection of Make of Switch Gears and other components of Panel shall be decided by the consultant (elec.) / Engineering Incharge) |
| 298 | Panel Size - As per Drawing submitted. |
| 299 | Cost of Fabcrcation part of LT. Panel & busbar system, in CRCA Sheet Steel enclosure (IP-43) without any components. |
| 300 | INCOMER :- |
| 301 | 400A FP MCCB (36kA) with adjustable thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links. |
| 302 | INDICATING FOR PANEL FOR LIFT MACHINE |
| 303 | Multi function-meter (0 – 500A) 96mmx96mm 4-position with selector switch for incomer. |
| 304 | CT 500/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. |
| 305 | Phase indicating light shall be protected by 2 Amps SP MCB's for incomer. |
| 306 | CHANGEOVER |
| 307 | 200A/ FP Changeover with extended front rotary handle -1 Nos. |
| 308 | OUTGOING |
| 309 | 100A/ FP/16kA MCCB with thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links -10 Nos. |
| 310 | 80A/FP/16kA MCCB with thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links. -10 Nos. |
| 311 | 63A FP MCB C-Series.-8 Nos. |
| 312 | 32A DP MCB C-Series.-4 Nos. |
| 313 | Total Cost of LT Panel |
| 314 | FLOOR LIGHT PANEL BUILDING : (For G+2 BUILDING) :- Supplying, designing, manufacturing, fitting, fixing, installation, testing and commissioning of LT Panel, fabricated out of 1.6mm thick (16 SWG) CRCA sheet steel IP:43, (dust and vermin proof) with reinforcement of suitable lifting arrangement effecting proper connection of all incomer and outgoing for all DBs , floor mounting type , fixed on base channel of 75mm x 75mm x 6mm, which will have incoming 3 phase power supply from Campus Sub-Station. |
| 315 | The sheet steel shall under go minimum of 7 tank treatment followed by finished powder coating of minimum 60 micron thickness and suitable for operation on 415V / 3 Ph / 50 Cy includes 415V electrolitic Al. bus bar with atleast 3 mm removable gland plate, cable glands including connection with outgoing feeders complete in all respect and should have bottom entry. |
| 316 | The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5/15A socket service outlet (single phase) and 1 no. CFL light with holder shall be provided in one of the compartments as service outlet in the panel. Panel shall be so designed as to have minimum 10% spare feeders/space. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. |
| 317 | The panel shall be interlocked with switchgear in such a way that no door can be opened when the switch is in ON position.The switch gear shall have mechanical arrangement for interlock defeat.The design of panel shall be such as to offer maximun safety and easey of maintenance. The gap between live part of the Panel shall be minimum 35mm. |
| 318 | The above Panel shall be completed with 3 Nos. LED phase indicating lamps with MCB protection, analogue ammeter, voltmeter, selector switches, CTs etc. as incomer with all interconnections and compartmentalised cubical type for installing meters with hinged and lockable door stand. All opening shall be covered by soft rubber gasket. All wires used for control circuit should be FRLS PVC insulated flexible copper wire of grade 1100V. |
| 319 | The MCCB's shall be Ics = 100% Icu, with rotary handle, spreader links & pad locking arrangement, with trip setting as per load requirement with short circuit & over current protection. The breaking capacity specified is Ics=Icu value. All MCCB's shall be of thermo magnetic category type. |
| 320 | AL. BUS BAR:- The panel includes 415V, 100A, 3Ph, 16KA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) G.I. Earth Bus with removable glands plates, cable glands at sending and receiving ends, including connection with outgoing feeders complete in all respects. The electrolytic Aluminium bus bar of grade 63401 WP as per I:S 5082 of suitable length and insulated by heat shrinkable sleeves Red, yellow, Blue and Black as R Y B & N. The current density of bus bar shall be minimum 0.8 A / sq mm. All inter connections from main Bus Bar to individual MCCB shall be made with 4, 6 & 10 Sq mm FRLS PVC Cu. wire with 35A 4 studs (Brass) treminal block.. |
| 321 | Each feeder shall have individual compartment with name plate with DB Nos., Floor No. and Block No. |
| 322 | Note:- Inspection of LT Panel shall be carried out by Engineering Incharge / Consultant (Eletcrical) at panel builder site and for that, all arragements shall be made by the suppilier on prior information to parrent department. |
| 323 | SLD along with the G.A. drawing of LT Panel will be submitted by the contractor to Engineering Incharge or to the Consultant for approval . The above SLD and G.A. Drawing of Main LT Panel must be based on approved SLD. |
| 324 | Selection of Make of Switch Gears and other components of Panel shall be decided by the consultant (elec.) / Engineering Incharge) |
| 325 | Panel Size - As per Drawing submitted. |
| 326 | Cost of Fabcrcation part of LT. Panel & busbar system, in CRCA Sheet Steel enclosure (IP-43) without any components. |
| 327 | INCOMER :- |
| 328 | 80A FP MCCB (16kA) with adjustable thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links. |
| 329 | INDICATING FOR PANEL FOR LIFT MACHINE |
| 330 | Multi function-meter (0 – 100A) 96mmx96mm 4-position with selector switch for incomer. |
| 331 | CT 100/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. |
| 332 | Phase indicating light shall be protected by 2 Amps SP MCB's for incomer. |
| 333 | OUTGOING |
| 334 | 40A FP MCB C-Series.-8 Nos. |
| 335 | 32A DP MCB C-Series.-2 Nos. |
| 336 | Total Cost of Floor Light Panel |
| 337 | FLOOR POWER PANEL BUILDING : (For G+4 BUILDING) :- Supplying, designing, manufacturing, fitting, fixing, installation, testing and commissioning of LT Panel, fabricated out of 1.6mm thick (16 SWG) CRCA sheet steel IP:43, (dust and vermin proof) with reinforcement of suitable lifting arrangement effecting proper connection of all incomer and outgoing for all DBs , floor mounting type , fixed on base channel of 75mm x 75mm x 6mm, which will have incoming 3 phase power supply from Campus Sub-Station. |
| 338 | The sheet steel shall under go minimum of 7 tank treatment followed by finished powder coating of minimum 60 micron thickness and suitable for operation on 415V / 3 Ph / 50 Cy includes 415V electrolitic Al. bus bar with atleast 3 mm removable gland plate, cable glands including connection with outgoing feeders complete in all respect and should have bottom entry. |
| 339 | The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5/15A socket service outlet (single phase) and 1 no. CFL light with holder shall be provided in one of the compartments as service outlet in the panel. Panel shall be so designed as to have minimum 10% spare feeders/space. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. |
| 340 | The panel shall be interlocked with switchgear in such a way that no door can be opened when the switch is in ON position.The switch gear shall have mechanical arrangement for interlock defeat.The design of panel shall be such as to offer maximun safety and easey of maintenance. The gap between live part of the Panel shall be minimum 35mm. |
| 341 | The above Panel shall be completed with 3 Nos. LED phase indicating lamps with MCB protection, analogue ammeter, voltmeter, selector switches, CTs etc. as incomer with all interconnections and compartmentalised cubical type for installing meters with hinged and lockable door stand. All opening shall be covered by soft rubber gasket. All wires used for control circuit should be FRLS PVC insulated flexible copper wire of grade 1100V. |
| 342 | The MCCB's shall be Ics = 100% Icu, with rotary handle, spreader links & pad locking arrangement, with trip setting as per load requirement with short circuit & over current protection. The breaking capacity specified is Ics=Icu value. All MCCB's shall be of thermo magnetic category type. |
| 343 | AL. BUS BAR:- The panel includes 415V, 200A, 3Ph, 25KA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) G.I. Earth Bus with removable glands plates, cable glands at sending and receiving ends, including connection with outgoing feeders complete in all respects. The electrolytic Aluminium bus bar of grade 63401 WP as per I:S 5082 of suitable length and insulated by heat shrinkable sleeves Red, yellow, Blue and Black as R Y B & N. The current density of bus bar shall be minimum 0.8 A / sq mm. All inter connections from main Bus Bar to individual MCCB shall be made with 4, 6 & 10 Sq mm FRLS PVC Cu. wire with 35A 4 studs (Brass) treminal block.. |
| 344 | Each feeder shall have individual compartment with name plate with DB Nos., Floor No. and Block No. |
| 345 | Note:- Inspection of LT Panel shall be carried out by Engineering Incharge / Consultant (Eletcrical) at panel builder site and for that, all arragements shall be made by the suppilier on prior information to parrent department. |
| 346 | SLD along with the G.A. drawing of LT Panel will be submitted by the contractor to Engineering Incharge or to the Consultant for approval . The above SLD and G.A. Drawing of Main LT Panel must be based on approved SLD. |
| 347 | Selection of Make of Switch Gears and other components of Panel shall be decided by the consultant (elec.) / Engineering Incharge) |
| 348 | Panel Size - As per Drawing submitted. |
| 349 | Cost of Fabcrcation part of LT. Panel & busbar system, in CRCA Sheet Steel enclosure (IP-43) without any components. |
| 350 | INCOMER :- |
| 351 | 100A FP MCCB (16kA) with adjustable thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links. |
| 352 | INDICATING FOR PANEL FOR LIFT MACHINE |
| 353 | Multi function-meter (0 – 100A) 96mmx96mm 4-position with selector switch for incomer. |
| 354 | CT 100/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. |
| 355 | Phase indicating light shall be protected by 2 Amps SP MCB's for incomer. |
| 356 | OUTGOING |
| 357 | 63A FP MCB C-Series.-8 Nos. |
| 358 | 32A DP MCB C-Series.-2 Nos. |
| 359 | Total Cost of Floor Power Panel |
| 360 | LT PANEL FOR Girl's HOSTEL BUILDING : (For G+8 BUILDING) :- Supplying, designing, manufacturing, fitting, fixing, installation, testing and commissioning of LT Panel, fabricated out of 1.6mm thick (16 SWG) CRCA sheet steel IP:43, (dust and vermin proof) with reinforcement of suitable lifting arrangement effecting proper connection of all incomer and outgoing for all DBs , floor mounting type , fixed on base channel of 75mm x 75mm x 6mm, which will have incoming 3 phase power supply from Campus Sub-Station. |
| 361 | The sheet steel shall under go minimum of 7 tank treatment followed by finished powder coating of minimum 60 micron thickness and suitable for operation on 415V / 3 Ph / 50 Cy includes 415V electrolitic Al. bus bar with atleast 3 mm removable gland plate, cable glands including connection with outgoing feeders complete in all respect and should have bottom entry. |
| 362 | The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5/15A socket service outlet (single phase) and 1 no. CFL light with holder shall be provided in one of the compartments as service outlet in the panel. Panel shall be so designed as to have minimum 10% spare feeders/space. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. |
| 363 | The panel shall be interlocked with switchgear in such a way that no door can be opened when the switch is in ON position.The switch gear shall have mechanical arrangement for interlock defeat.The design of panel shall be such as to offer maximun safety and easey of maintenance. The gap between live part of the Panel shall be minimum 35mm. |
| 364 | The above Panel shall be completed with 3 Nos. LED phase indicating lamps with MCB protection, analogue ammeter, voltmeter, selector switches, CTs etc. as incomer with all interconnections and compartmentalised cubical type for installing meters with hinged and lockable door stand. All opening shall be covered by soft rubber gasket. All wires used for control circuit should be FRLS PVC insulated flexible copper wire of grade 1100V. |
| 365 | The MCCB's shall be Ics = 100% Icu, with rotary handle, spreader links & pad locking arrangement, with trip setting as per load requirement with short circuit & over current protection. The breaking capacity specified is Ics=Icu value. All MCCB's shall be of thermo magnetic category type. |
| 366 | AL. BUS BAR:- The panel includes 415V, 400A, 3Ph, 36KA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) G.I. Earth Bus with removable glands plates, cable glands at sending and receiving ends, including connection with outgoing feeders complete in all respects. The electrolytic Aluminium bus bar of grade 63401 WP as per I:S 5082 of suitable length and insulated by heat shrinkable sleeves Red, yellow, Blue and Black as R Y B & N. The current density of bus bar shall be minimum 0.8 A / sq mm. All inter connections from main Bus Bar to individual MCCB shall be made with 4, 6 & 10 Sq mm FRLS PVC Cu. wire with 35A 4 studs (Brass) treminal block.. |
| 367 | Each feeder shall have individual compartment with name plate with DB Nos., Floor No. and Block No. |
| 368 | Note:- Inspection of LT Panel shall be carried out by Engineering Incharge / Consultant (Eletcrical) at panel builder site and for that, all arragements shall be made by the suppilier on prior information to parrent department. |
| 369 | SLD along with the G.A. drawing of LT Panel will be submitted by the contractor to Engineering Incharge or to the Consultant for approval . The above SLD and G.A. Drawing of Main LT Panel must be based on approved SLD. |
| 370 | Selection of Make of Switch Gears and other components of Panel shall be decided by the consultant (elec.) / Engineering Incharge) |
| 371 | Panel Size - As per Drawing submitted. |
| 372 | Cost of Fabcrcation part of LT. Panel & busbar system, in CRCA Sheet Steel enclosure (IP-43) without any components. |
| 373 | INCOMER :- |
| 374 | 400A FP MCCB (36kA) with adjustable thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links. |
| 375 | INDICATING FOR PANEL FOR LIFT MACHINE |
| 376 | Multi function-meter (0 – 500A) 96mmx96mm 4-position with selector switch for incomer. |
| 377 | CT 500/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. |
| 378 | Phase indicating light shall be protected by 2 Amps SP MCB's for incomer. |
| 379 | OUTGOING |
| 380 | 100A/ FP/16kA MCCB with thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links -1No. |
| 381 | 80A/FP/16kA MCCB with thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links. -8 Nos. |
| 382 | 63A FP MCB C-Series.-4 Nos. |
| 383 | 32A DP MCB C-Series.-2 Nos. |
| 384 | Total Cost of LT Panel for Girl's Hostel |
| 385 | FLOOR PANEL FOR Girl's HOSTEL BUILDING : (For G+8 BUILDING) :- Supplying, designing, manufacturing, fitting, fixing, installation, testing and commissioning of LT Panel, fabricated out of 1.6mm thick (16 SWG) CRCA sheet steel IP:43, (dust and vermin proof) with reinforcement of suitable lifting arrangement effecting proper connection of all incomer and outgoing for all DBs , floor mounting type , fixed on base channel of 75mm x 75mm x 6mm, which will have incoming 3 phase power supply from Campus Sub-Station. |
| 386 | The sheet steel shall under go minimum of 7 tank treatment followed by finished powder coating of minimum 60 micron thickness and suitable for operation on 415V / 3 Ph / 50 Cy includes 415V electrolitic Al. bus bar with atleast 3 mm removable gland plate, cable glands including connection with outgoing feeders complete in all respect and should have bottom entry. |
| 387 | The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5/15A socket service outlet (single phase) and 1 no. CFL light with holder shall be provided in one of the compartments as service outlet in the panel. Panel shall be so designed as to have minimum 10% spare feeders/space. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. |
| 388 | The panel shall be interlocked with switchgear in such a way that no door can be opened when the switch is in ON position.The switch gear shall have mechanical arrangement for interlock defeat.The design of panel shall be such as to offer maximun safety and easey of maintenance. The gap between live part of the Panel shall be minimum 35mm. |
| 389 | The above Panel shall be completed with 3 Nos. LED phase indicating lamps with MCB protection, analogue ammeter, voltmeter, selector switches, CTs etc. as incomer with all interconnections and compartmentalised cubical type for installing meters with hinged and lockable door stand. All opening shall be covered by soft rubber gasket. All wires used for control circuit should be FRLS PVC insulated flexible copper wire of grade 1100V. |
| 390 | The MCCB's shall be Ics = 100% Icu, with rotary handle, spreader links & pad locking arrangement, with trip setting as per load requirement with short circuit & over current protection. The breaking capacity specified is Ics=Icu value. All MCCB's shall be of thermo magnetic category type. |
| 391 | AL. BUS BAR:- The panel includes 415V, 100A, 3Ph, 16KA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) G.I. Earth Bus with removable glands plates, cable glands at sending and receiving ends, including connection with outgoing feeders complete in all respects. The electrolytic Aluminium bus bar of grade 63401 WP as per I:S 5082 of suitable length and insulated by heat shrinkable sleeves Red, yellow, Blue and Black as R Y B & N. The current density of bus bar shall be minimum 0.8 A / sq mm. All inter connections from main Bus Bar to individual MCCB shall be made with 4, 6 & 10 Sq mm FRLS PVC Cu. wire with 35A 4 studs (Brass) treminal block.. |
| 392 | Each feeder shall have individual compartment with name plate with DB Nos., Floor No. and Block No. |
| 393 | Note:- Inspection of LT Panel shall be carried out by Engineering Incharge / Consultant (Eletcrical) at panel builder site and for that, all arragements shall be made by the suppilier on prior information to parrent department. |
| 394 | SLD along with the G.A. drawing of LT Panel will be submitted by the contractor to Engineering Incharge or to the Consultant for approval . The above SLD and G.A. Drawing of Main LT Panel must be based on approved SLD. |
| 395 | Selection of Make of Switch Gears and other components of Panel shall be decided by the consultant (elec.) / Engineering Incharge) |
| 396 | Panel Size - As per Drawing submitted. |
| 397 | Cost of Fabcrcation part of LT. Panel & busbar system, in CRCA Sheet Steel enclosure (IP-43) without any components. |
| 398 | INCOMER :- |
| 399 | 80A FP MCCB (16kA) with adjustable thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links. |
| 400 | INDICATING FOR PANEL FOR LIFT MACHINE |
| 401 | Multi function-meter (0 – 100A) 96mmx96mm 4-position with selector switch for incomer. Make- L& T./ AE/ Schneider. |
| 402 | CT 100/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. |
| 403 | Phase indicating light shall be protected by 2 Amps SP MCB's for incomer. |
| 404 | OUTGOING |
| 405 | 63A FP MCB C-Series.-6 Nos. |
| 406 | 32A DP MCB C-Series.-2 Nos. |
| 407 | Total Cost of LT Panel for Girl's Hostel |
| 408 | FLOOR UPS PANEL BUILDING : (For G+2 BUILDING) :- Supplying, designing, manufacturing, fitting, fixing, installation, testing and commissioning of LT Panel, fabricated out of 1.6mm thick (16 SWG) CRCA sheet steel IP:43, (dust and vermin proof) with reinforcement of suitable lifting arrangement effecting proper connection of all incomer and outgoing for all DBs , floor mounting type , fixed on base channel of 75mm x 75mm x 6mm, which will have incoming 3 phase power supply from Campus Sub-Station. |
| 409 | The sheet steel shall under go minimum of 7 tank treatment followed by finished powder coating of minimum 60 micron thickness and suitable for operation on 415V / 3 Ph / 50 Cy includes 415V electrolitic Al. bus bar with atleast 3 mm removable gland plate, cable glands including connection with outgoing feeders complete in all respect and should have bottom entry. |
| 410 | The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5/15A socket service outlet (single phase) and 1 no. CFL light with holder shall be provided in one of the compartments as service outlet in the panel. Panel shall be so designed as to have minimum 10% spare feeders/space. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. |
| 411 | The panel shall be interlocked with switchgear in such a way that no door can be opened when the switch is in ON position.The switch gear shall have mechanical arrangement for interlock defeat.The design of panel shall be such as to offer maximun safety and easey of maintenance. The gap between live part of the Panel shall be minimum 35mm. |
| 412 | The above Panel shall be completed with 3 Nos. LED phase indicating lamps with MCB protection, analogue ammeter, voltmeter, selector switches, CTs etc. as incomer with all interconnections and compartmentalised cubical type for installing meters with hinged and lockable door stand. All opening shall be covered by soft rubber gasket. All wires used for control circuit should be FRLS PVC insulated flexible copper wire of grade 1100V. |
| 413 | The MCCB's shall be Ics = 100% Icu, with rotary handle, spreader links & pad locking arrangement, with trip setting as per load requirement with short circuit & over current protection. The breaking capacity specified is Ics=Icu value. All MCCB's shall be of thermo magnetic category type. |
| 414 | AL. BUS BAR:- The panel includes 415V, 200A, 3Ph, 25KA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) G.I. Earth Bus with removable glands plates, cable glands at sending and receiving ends, including connection with outgoing feeders complete in all respects. The electrolytic Aluminium bus bar of grade 63401 WP as per I:S 5082 of suitable length and insulated by heat shrinkable sleeves Red, yellow, Blue and Black as R Y B & N. The current density of bus bar shall be minimum 0.8 A / sq mm. All inter connections from main Bus Bar to individual MCCB shall be made with 4, 6 & 10 Sq mm FRLS PVC Cu. wire with 35A 4 studs (Brass) treminal block.. |
| 415 | Each feeder shall have individual compartment with name plate with DB Nos., Floor No. and Block No. |
| 416 | Note:- Inspection of LT Panel shall be carried out by Engineering Incharge / Consultant (Eletcrical) at panel builder site and for that, all arragements shall be made by the suppilier on prior information to parrent department. |
| 417 | SLD along with the G.A. drawing of LT Panel will be submitted by the contractor to Engineering Incharge or to the Consultant for approval . The above SLD and G.A. Drawing of Main LT Panel must be based on approved SLD. |
| 418 | Selection of Make of Switch Gears and other components of Panel shall be decided by the consultant (elec.) / Engineering Incharge) |
| 419 | Panel Size - As per Drawing submitted. |
| 420 | Cost of Fabcrcation part of LT. Panel & busbar system, in CRCA Sheet Steel enclosure (IP-43) without any components. |
| 421 | INCOMER :- |
| 422 | 100A FP MCCB (16kA) with adjustable thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links. |
| 423 | INDICATING FOR PANEL FOR LIFT MACHINE |
| 424 | Multi function-meter (0 – 100A) 96mmx96mm 4-position with selector switch for incomer. |
| 425 | CT 100/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. |
| 426 | Phase indicating light shall be protected by 2 Amps SP MCB's for incomer. |
| 427 | OUTGOING |
| 428 | 40A FP MCB C-Series.-20 Nos. |
| 429 | 32A DP MCB C-Series.-2 Nos. |
| 430 | Total Cost of Floor Power Panel |
| 431 | LT PANEL FOR SRC BUILDING : (For G+5 BUILDING) :- Supplying, designing, manufacturing, fitting, fixing, installation, testing and commissioning of LT Panel, fabricated out of 1.6mm thick (16 SWG) CRCA sheet steel IP:43, (dust and vermin proof) with reinforcement of suitable lifting arrangement effecting proper connection of all incomer and outgoing for all DBs , floor mounting type , fixed on base channel of 75mm x 75mm x 6mm, which will have incoming 3 phase power supply from Campus Sub-Station. |
| 432 | The sheet steel shall under go minimum of 7 tank treatment followed by finished powder coating of minimum 60 micron thickness and suitable for operation on 415V / 3 Ph / 50 Cy includes 415V electrolitic Al. bus bar with atleast 3 mm removable gland plate, cable glands including connection with outgoing feeders complete in all respect and should have bottom entry. |
| 433 | The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5/15A socket service outlet (single phase) and 1 no. CFL light with holder shall be provided in one of the compartments as service outlet in the panel. Panel shall be so designed as to have minimum 10% spare feeders/space. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. |
| 434 | The panel shall be interlocked with switchgear in such a way that no door can be opened when the switch is in ON position.The switch gear shall have mechanical arrangement for interlock defeat.The design of panel shall be such as to offer maximun safety and easey of maintenance. The gap between live part of the Panel shall be minimum 35mm. |
| 435 | The above Panel shall be completed with 3 Nos. LED phase indicating lamps with MCB protection, analogue ammeter, voltmeter, selector switches, CTs etc. as incomer with all interconnections and compartmentalised cubical type for installing meters with hinged and lockable door stand. All opening shall be covered by soft rubber gasket. All wires used for control circuit should be FRLS PVC insulated flexible copper wire of grade 1100V. |
| 436 | The MCCB's shall be Ics = 100% Icu, with rotary handle, spreader links & pad locking arrangement, with trip setting as per load requirement with short circuit & over current protection. The breaking capacity specified is Ics=Icu value. All MCCB's shall be of thermo magnetic category type. |
| 437 | AL. BUS BAR:- The panel includes 415V, 400A, 3Ph, 36KA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) G.I. Earth Bus with removable glands plates, cable glands at sending and receiving ends, including connection with outgoing feeders complete in all respects. The electrolytic Aluminium bus bar of grade 63401 WP as per I:S 5082 of suitable length and insulated by heat shrinkable sleeves Red, yellow, Blue and Black as R Y B & N. The current density of bus bar shall be minimum 0.8 A / sq mm. All inter connections from main Bus Bar to individual MCCB shall be made with 4, 6 & 10 Sq mm FRLS PVC Cu. wire with 35A 4 studs (Brass) treminal block.. |
| 438 | Each feeder shall have individual compartment with name plate with DB Nos., Floor No. and Block No. |
| 439 | Note:- Inspection of LT Panel shall be carried out by Engineering Incharge / Consultant (Eletcrical) at panel builder site and for that, all arragements shall be made by the suppilier on prior information to parrent department. |
| 440 | SLD along with the G.A. drawing of LT Panel will be submitted by the contractor to Engineering Incharge or to the Consultant for approval . The above SLD and G.A. Drawing of Main LT Panel must be based on approved SLD. |
| 441 | Selection of Make of Switch Gears and other components of Panel shall be decided by the consultant (elec.) / Engineering Incharge) |
| 442 | Panel Size - As per Drawing submitted. |
| 443 | Cost of Fabcrcation part of LT. Panel & busbar system, in CRCA Sheet Steel enclosure (IP-43) without any components. |
| 444 | INCOMER :- |
| 445 | 400A FP MCCB (36kA) with adjustable thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links. |
| 446 | INDICATING FOR PANEL FOR LIFT MACHINE |
| 447 | Multi function-meter (0 – 500A) 96mmx96mm 4-position with selector switch for incomer. |
| 448 | CT 500/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. |
| 449 | Phase indicating light shall be protected by 2 Amps SP MCB's for incomer. |
| 450 | CHANGEOVER |
| 451 | 200A/ FP Changeover with extended front rotary handle -1 Nos. |
| 452 | OUTGOING |
| 453 | 100A/ FP/16kA MCCB with thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links -8 Nos. |
| 454 | 80A/FP/16kA MCCB with thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links. -8 Nos. |
| 455 | 63A FP MCB C-Series.-4 Nos. |
| 456 | 32A DP MCB C-Series.-2 Nos. |
| 457 | Total Cost of LT Panel |
| 458 | FLOOR LIGHT PANEL BUILDING : (For G+5 BUILDING) :- Supplying, designing, manufacturing, fitting, fixing, installation, testing and commissioning of LT Panel, fabricated out of 1.6mm thick (16 SWG) CRCA sheet steel IP:43, (dust and vermin proof) with reinforcement of suitable lifting arrangement effecting proper connection of all incomer and outgoing for all DBs , floor mounting type , fixed on base channel of 75mm x 75mm x 6mm, which will have incoming 3 phase power supply from Campus Sub-Station. |
| 459 | The sheet steel shall under go minimum of 7 tank treatment followed by finished powder coating of minimum 60 micron thickness and suitable for operation on 415V / 3 Ph / 50 Cy includes 415V electrolitic Al. bus bar with atleast 3 mm removable gland plate, cable glands including connection with outgoing feeders complete in all respect and should have bottom entry. |
| 460 | The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5/15A socket service outlet (single phase) and 1 no. CFL light with holder shall be provided in one of the compartments as service outlet in the panel. Panel shall be so designed as to have minimum 10% spare feeders/space. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. |
| 461 | The panel shall be interlocked with switchgear in such a way that no door can be opened when the switch is in ON position.The switch gear shall have mechanical arrangement for interlock defeat.The design of panel shall be such as to offer maximun safety and easey of maintenance. The gap between live part of the Panel shall be minimum 35mm. |
| 462 | The above Panel shall be completed with 3 Nos. LED phase indicating lamps with MCB protection, analogue ammeter, voltmeter, selector switches, CTs etc. as incomer with all interconnections and compartmentalised cubical type for installing meters with hinged and lockable door stand. All opening shall be covered by soft rubber gasket. All wires used for control circuit should be FRLS PVC insulated flexible copper wire of grade 1100V. |
| 463 | The MCCB's shall be Ics = 100% Icu, with rotary handle, spreader links & pad locking arrangement, with trip setting as per load requirement with short circuit & over current protection. The breaking capacity specified is Ics=Icu value. All MCCB's shall be of thermo magnetic category type. |
| 464 | AL. BUS BAR:- The panel includes 415V, 100A, 3Ph, 16KA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) G.I. Earth Bus with removable glands plates, cable glands at sending and receiving ends, including connection with outgoing feeders complete in all respects. The electrolytic Aluminium bus bar of grade 63401 WP as per I:S 5082 of suitable length and insulated by heat shrinkable sleeves Red, yellow, Blue and Black as R Y B & N. The current density of bus bar shall be minimum 0.8 A / sq mm. All inter connections from main Bus Bar to individual MCCB shall be made with 4, 6 & 10 Sq mm FRLS PVC Cu. wire with 35A 4 studs (Brass) treminal block.. |
| 465 | Each feeder shall have individual compartment with name plate with DB Nos., Floor No. and Block No. |
| 466 | Note:- Inspection of LT Panel shall be carried out by Engineering Incharge / Consultant (Eletcrical) at panel builder site and for that, all arragements shall be made by the suppilier on prior information to parrent department. |
| 467 | SLD along with the G.A. drawing of LT Panel will be submitted by the contractor to Engineering Incharge or to the Consultant for approval . The above SLD and G.A. Drawing of Main LT Panel must be based on approved SLD. |
| 468 | Selection of Make of Switch Gears and other components of Panel shall be decided by the consultant (elec.) / Engineering Incharge) |
| 469 | Panel Size - As per Drawing submitted. |
| 470 | Cost of Fabcrcation part of LT. Panel & busbar system, in CRCA Sheet Steel enclosure (IP-43) without any components. |
| 471 | INCOMER :- |
| 472 | 80A FP MCCB (16kA) with adjustable thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links. |
| 473 | INDICATING FOR PANEL FOR LIFT MACHINE |
| 474 | Multi function-meter (0 – 100A) 96mmx96mm 4-position with selector switch for incomer. |
| 475 | CT 100/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. |
| 476 | Phase indicating light shall be protected by 2 Amps SP MCB's for incomer. |
| 477 | OUTGOING |
| 478 | 40A FP MCB C-Series.-8 Nos. |
| 479 | 32A DP MCB C-Series.-2 Nos. |
| 480 | Total Cost of Floor Light Panel |
| 481 | FLOOR POWER PANEL BUILDING : (For G+5 BUILDING) :- Supplying, designing, manufacturing, fitting, fixing, installation, testing and commissioning of LT Panel, fabricated out of 1.6mm thick (16 SWG) CRCA sheet steel IP:43, (dust and vermin proof) with reinforcement of suitable lifting arrangement effecting proper connection of all incomer and outgoing for all DBs , floor mounting type , fixed on base channel of 75mm x 75mm x 6mm, which will have incoming 3 phase power supply from Campus Sub-Station. |
| 482 | The sheet steel shall under go minimum of 7 tank treatment followed by finished powder coating of minimum 60 micron thickness and suitable for operation on 415V / 3 Ph / 50 Cy includes 415V electrolitic Al. bus bar with atleast 3 mm removable gland plate, cable glands including connection with outgoing feeders complete in all respect and should have bottom entry. |
| 483 | The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5/15A socket service outlet (single phase) and 1 no. CFL light with holder shall be provided in one of the compartments as service outlet in the panel. Panel shall be so designed as to have minimum 10% spare feeders/space. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. |
| 484 | The panel shall be interlocked with switchgear in such a way that no door can be opened when the switch is in ON position.The switch gear shall have mechanical arrangement for interlock defeat.The design of panel shall be such as to offer maximun safety and easey of maintenance. The gap between live part of the Panel shall be minimum 35mm. |
| 485 | The above Panel shall be completed with 3 Nos. LED phase indicating lamps with MCB protection, analogue ammeter, voltmeter, selector switches, CTs etc. as incomer with all interconnections and compartmentalised cubical type for installing meters with hinged and lockable door stand. All opening shall be covered by soft rubber gasket. All wires used for control circuit should be FRLS PVC insulated flexible copper wire of grade 1100V. |
| 486 | The MCCB's shall be Ics = 100% Icu, with rotary handle, spreader links & pad locking arrangement, with trip setting as per load requirement with short circuit & over current protection. The breaking capacity specified is Ics=Icu value. All MCCB's shall be of thermo magnetic category type. |
| 487 | AL. BUS BAR:- The panel includes 415V, 200A, 3Ph, 25KA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) G.I. Earth Bus with removable glands plates, cable glands at sending and receiving ends, including connection with outgoing feeders complete in all respects. The electrolytic Aluminium bus bar of grade 63401 WP as per I:S 5082 of suitable length and insulated by heat shrinkable sleeves Red, yellow, Blue and Black as R Y B & N. The current density of bus bar shall be minimum 0.8 A / sq mm. All inter connections from main Bus Bar to individual MCCB shall be made with 4, 6 & 10 Sq mm FRLS PVC Cu. wire with 35A 4 studs (Brass) treminal block.. |
| 488 | Each feeder shall have individual compartment with name plate with DB Nos., Floor No. and Block No. |
| 489 | Note:- Inspection of LT Panel shall be carried out by Engineering Incharge / Consultant (Eletcrical) at panel builder site and for that, all arragements shall be made by the suppilier on prior information to parrent department. |
| 490 | SLD along with the G.A. drawing of LT Panel will be submitted by the contractor to Engineering Incharge or to the Consultant for approval . The above SLD and G.A. Drawing of Main LT Panel must be based on approved SLD. |
| 491 | Selection of Make of Switch Gears and other components of Panel shall be decided by the consultant (elec.) / Engineering Incharge) |
| 492 | Panel Size - As per Drawing submitted. |
| 493 | Cost of Fabcrcation part of LT. Panel & busbar system, in CRCA Sheet Steel enclosure (IP-43) without any components. tix Private Ltd./ ADLAK. (A) |
| 494 | INCOMER :- |
| 495 | 100A FP MCCB (16kA) with adjustable thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links. |
| 496 | INDICATING FOR PANEL FOR LIFT MACHINE |
| 497 | Multi function-meter (0 – 100A) 96mmx96mm 4-position with selector switch for incomer. |
| 498 | CT 100/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. |
| 499 | Phase indicating light shall be protected by 2 Amps SP MCB's for incomer. |
| 500 | OUTGOING |
| 501 | 63A FP MCB C-Series.-8 Nos. |
| 502 | 32A DP MCB C-Series.-2 Nos. |
| 503 | Total Cost of Floor Power Panel |
| 504 | FLOOR UPS PANEL BUILDING : (For G+5 BUILDING) :- Supplying, designing, manufacturing, fitting, fixing, installation, testing and commissioning of LT Panel, fabricated out of 1.6mm thick (16 SWG) CRCA sheet steel IP:43, (dust and vermin proof) with reinforcement of suitable lifting arrangement effecting proper connection of all incomer and outgoing for all DBs , floor mounting type , fixed on base channel of 75mm x 75mm x 6mm, which will have incoming 3 phase power supply from Campus Sub-Station. |
| 505 | The sheet steel shall under go minimum of 7 tank treatment followed by finished powder coating of minimum 60 micron thickness and suitable for operation on 415V / 3 Ph / 50 Cy includes 415V electrolitic Al. bus bar with atleast 3 mm removable gland plate, cable glands including connection with outgoing feeders complete in all respect and should have bottom entry. |
| 506 | The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5/15A socket service outlet (single phase) and 1 no. CFL light with holder shall be provided in one of the compartments as service outlet in the panel. Panel shall be so designed as to have minimum 10% spare feeders/space. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. |
| 507 | The panel shall be interlocked with switchgear in such a way that no door can be opened when the switch is in ON position.The switch gear shall have mechanical arrangement for interlock defeat.The design of panel shall be such as to offer maximun safety and easey of maintenance. The gap between live part of the Panel shall be minimum 35mm. |
| 508 | The above Panel shall be completed with 3 Nos. LED phase indicating lamps with MCB protection, analogue ammeter, voltmeter, selector switches, CTs etc. as incomer with all interconnections and compartmentalised cubical type for installing meters with hinged and lockable door stand. All opening shall be covered by soft rubber gasket. All wires used for control circuit should be FRLS PVC insulated flexible copper wire of grade 1100V. |
| 509 | The MCCB's shall be Ics = 100% Icu, with rotary handle, spreader links & pad locking arrangement, with trip setting as per load requirement with short circuit & over current protection. The breaking capacity specified is Ics=Icu value. All MCCB's shall be of thermo magnetic category type. |
| 510 | AL. BUS BAR:- The panel includes 415V, 200A, 3Ph, 25KA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) G.I. Earth Bus with removable glands plates, cable glands at sending and receiving ends, including connection with outgoing feeders complete in all respects. The electrolytic Aluminium bus bar of grade 63401 WP as per I:S 5082 of suitable length and insulated by heat shrinkable sleeves Red, yellow, Blue and Black as R Y B & N. The current density of bus bar shall be minimum 0.8 A / sq mm. All inter connections from main Bus Bar to individual MCCB shall be made with 4, 6 & 10 Sq mm FRLS PVC Cu. wire with 35A 4 studs (Brass) treminal block.. |
| 511 | Each feeder shall have individual compartment with name plate with DB Nos., Floor No. and Block No. |
| 512 | Note:- Inspection of LT Panel shall be carried out by Engineering Incharge / Consultant (Eletcrical) at panel builder site and for that, all arragements shall be made by the suppilier on prior information to parrent department. |
| 513 | SLD along with the G.A. drawing of LT Panel will be submitted by the contractor to Engineering Incharge or to the Consultant for approval . The above SLD and G.A. Drawing of Main LT Panel must be based on approved SLD. |
| 514 | Selection of Make of Switch Gears and other components of Panel shall be decided by the consultant (elec.) / Engineering Incharge) |
| 515 | Panel Size - As per Drawing submitted. |
| 516 | Cost of Fabcrcation part of LT. Panel & busbar system, in CRCA Sheet Steel enclosure (IP-43) without any components. |
| 517 | INCOMER :- |
| 518 | 100A FP MCCB (16kA) with adjustable thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links. |
| 519 | INDICATING FOR PANEL FOR LIFT MACHINE |
| 520 | Multi function-meter (0 – 100A) 96mmx96mm 4-position with selector switch for incomer. Make- L& T./ AE/ Schneider. |
| 521 | CT 100/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. |
| 522 | Phase indicating light shall be protected by 2 Amps SP MCB's for incomer.Make-L& T./ AE/ Schneider. |
| 523 | OUTGOING |
| 524 | 40A FP MCB C-Series.-20 Nos. |
| 525 | 32A DP MCB C-Series.-2 Nos. |
| 526 | Total Cost of Floor Power Panel |
| 527 | MAIN LT PANEL :- Supplying, designing, manufacturing, fitting, fixing, installation, testing and commissioning of LT Panel, fabricated out of 2mm thick (14 SWG) CRCA sheet steel IP:43, (dust and vermin proof) with reinforcement of suitable lifting arrangement effecting proper connection of all incomer and outgoing for all DBs , floor mounting type , fixed on base channel of 75mm x 75mm x 6mm, which will have incoming 3 phase power supply from Campus Sub-Station. |
| 528 | The sheet steel shall under go minimum of 7 tank treatment followed by finished powder coating of minimum 60 micron thickness and suitable for operation on 415V / 3 Ph / 50 Cy includes 415V electrolitic Al. bus bar with atleast 3 mm removable gland plate, cable glands including connection with outgoing feeders complete in all respect and should have bottom entry. |
| 529 | The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5/15A socket service outlet (single phase) and 1 no. CFL light with holder shall be provided in one of the compartments as service outlet in the panel. Panel shall be so designed as to have minimum 10% spare feeders/space. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. |
| 530 | The panel shall be interlocked with switchgear in such a way that no door can be opened when the switch is in ON position.The switch gear shall have mechanical arrangement for interlock defeat.The design of panel shall be such as to offer maximun safety and easey of maintenance. The gap between live part of the Panel shall be minimum 35mm. |
| 531 | The above Panel shall be completed with 3 Nos. LED phase indicating lamps with MCB protection, analogue ammeter, voltmeter, selector switches, CTs etc. as incomer with all interconnections and compartmentalised cubical type for installing meters with hinged and lockable door stand. All opening shall be covered by soft rubber gasket. All wires used for control circuit should be FRLS PVC insulated flexible copper wire of grade 1100V. |
| 532 | The MCCB's shall be Ics = 100% Icu, with rotary handle, spreader links & pad locking arrangement, with trip setting as per load requirement with short circuit & over current protection. The breaking capacity specified is Ics=Icu value. All MCCB's shall be of thermo magnetic category type. |
| 533 | AL. BUS BAR:- The panel includes 415V, 1600A, 3Ph,50KA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) G.I. Earth Bus with removable glands plates, cable glands at sending and receiving ends, including connection with outgoing feeders complete in all respects. The electrolytic Aluminium bus bar of grade 63401 WP as per I:S 5082 of suitable length and insulated by heat shrinkable sleeves Red, yellow, Blue and Black as R Y B & N. The current density of bus bar shall be minimum 0.8 A / sq mm. All inter connections from main Bus Bar to individual MCCB shall be made with 4, 6 & 10 Sq mm FRLS PVC Cu. wire with 35A 4 studs (Brass) treminal block.. |
| 534 | Each feeder shall have individual compartment with name plate with DB Nos., Floor No. and Block No. |
| 535 | Note:- Inspection of LT Panel shall be carried out by Engineering Incharge / Consultant (Eletcrical) at panel builder site and for that, all arragements shall be made by the suppilier on prior information to parrent department. |
| 536 | SLD along with the G.A. drawing of LT Panel will be submitted by the contractor to Engineering Incharge or to the Consultant for approval . The above SLD and G.A. Drawing of Main LT Panel must be based on approved SLD. |
| 537 | Selection of Make of Switch Gears and other components of Panel shall be decided by the consultant (elec.) / Engineering Incharge) |
| 538 | Panel Size - As per Drawing submitted. |
| 539 | INCOMER :- |
| 540 | 1250A FP ACB (50kA)-2 Nos. EDO type with S/C & O/L protection. |
| 541 | INDICATING FOR PANEL FOR LIFT MACHINE |
| 542 | Multi function-meter (0 –1250A) 96mmx96mm 4-position with selector switch for incomer. |
| 543 | CT 1250/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. |
| 544 | Phase indicating light shall be protected by 2 Amps SP MCB's for incomer. |
| 545 | OUTGOING |
| 546 | 630 A/ FP/36kA MCCB . with thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links -1Nos. |
| 547 | 400 A/ FP/36kA MCCB with thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links -12 Nos. |
| 548 | 250 A/ FP/36kA MCCB with thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links -1 Nos. |
| 549 | 200 A/ FP/36kA MCCB with thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links -1 Nos. |
| 550 | 63 A/ FP/25kA MCCB with thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links -1 Nos. |
| 551 | Total Cost of MAIN LT Panel |
| 552 | COMMON PANEL-1 EXTERNAL : Supplying, designing, manufacturing, fitting, fixing, installation, testing and commissioning of LT Panel, fabricated out of 1.6mm thick (16 SWG) CRCA sheet steel IP:43, (dust and vermin proof) with reinforcement of suitable lifting arrangement effecting proper connection of all incomer and outgoing for all DBs , floor mounting type , fixed on base channel of 75mm x 75mm x 6mm, which will have incoming 3 phase power supply from Campus Sub-Station. |
| 553 | The sheet steel shall under go minimum of 7 tank treatment followed by finished powder coating of minimum 60 micron thickness and suitable for operation on 415V / 3 Ph / 50 Cy includes 415V electrolitic Al. bus bar with atleast 3 mm removable gland plate, cable glands including connection with outgoing feeders complete in all respect and should have bottom entry. |
| 554 | The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5/15A socket service outlet (single phase) and 1 no. CFL light with holder shall be provided in one of the compartments as service outlet in the panel. Panel shall be so designed as to have minimum 10% spare feeders/space. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. |
| 555 | The panel shall be interlocked with switchgear in such a way that no door can be opened when the switch is in ON position.The switch gear shall have mechanical arrangement for interlock defeat.The design of panel shall be such as to offer maximun safety and easey of maintenance. The gap between live part of the Panel shall be minimum 35mm. |
| 556 | The above Panel shall be completed with 3 Nos. LED phase indicating lamps with MCB protection, analogue ammeter, voltmeter, selector switches, CTs etc. as incomer with all interconnections and compartmentalised cubical type for installing meters with hinged and lockable door stand. All opening shall be covered by soft rubber gasket. All wires used for control circuit should be FRLS PVC insulated flexible copper wire of grade 1100V. |
| 557 | The MCCB's shall be Ics = 100% Icu, with rotary handle, spreader links & pad locking arrangement, with trip setting as per load requirement with short circuit & over current protection. The breaking capacity specified is Ics=Icu value. All MCCB's shall be of thermo magnetic category type. |
| 558 | AL. BUS BAR:- The panel includes 415V, 500A, 3Ph, 36KA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) G.I. Earth Bus with removable glands plates, cable glands at sending and receiving ends, including connection with outgoing feeders complete in all respects. The electrolytic Aluminium bus bar of grade 63401 WP as per I:S 5082 of suitable length and insulated by heat shrinkable sleeves Red, yellow, Blue and Black as R Y B & N. The current density of bus bar shall be minimum 0.8 A / sq mm. All inter connections from main Bus Bar to individual MCCB shall be made with 4, 6 & 10 Sq mm FRLS PVC Cu. wire with 35A 4 studs (Brass) treminal block.. |
| 559 | Each feeder shall have individual compartment with name plate with DB Nos., Floor No. and Block No. |
| 560 | Note:- Inspection of LT Panel shall be carried out by Engineering Incharge / Consultant (Eletcrical) at panel builder site and for that, all arragements shall be made by the suppilier on prior information to parrent department. |
| 561 | SLD along with the G.A. drawing of LT Panel will be submitted by the contractor to Engineering Incharge or to the Consultant for approval . The above SLD and G.A. Drawing of Main LT Panel must be based on approved SLD. |
| 562 | Selection of Make of Switch Gears and other components of Panel shall be decided by the consultant (elec.) / Engineering Incharge) |
| 563 | Panel Size - As per Drawing submitted. |
| 564 | Cost of Fabcrcation part of LT. Panel & busbar system, in CRCA Sheet Steel enclosure (IP-43) without any components. Name of Panel Builder :- SPC Electrotech Pvt. Ltd. / EAP / PM Control/TTS Systematix Private Ltd./ ADLAK. (A) |
| 565 | Make of MCCB - L&T D-Sine/ Legrand DPX³ / Schneider-NSX / Siemens - 3VL-or 3 VA |
| 566 | Make of MCB- C Series 10kA- Legrand/Schneider/ Siemens/ L&T. |
| 567 | INCOMER :- |
| 568 | 400A FP MCCB (36kA) with adjustable thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links. |
| 569 | INDICATING FOR PANEL FOR LIFT MACHINE |
| 570 | Multi function-meter (0 – 500A) 96mmx96mm 4-position with selector switch for incomer. Make- L& T./ AE/ Schneider. Make- Kaycee/L&T/Schneider. |
| 571 | CT 500/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. Make:-Kappa / Matrix |
| 572 | Phase indicating light shall be protected by 2 Amps SP MCB's for incomer.Make-L& T./ AE/ Schneider. |
| 573 | OUTGOING |
| 574 | 200A/ FP/36kA MCCB with thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links -1 Nos. |
| 575 | 125A/ FP/25kA MCCB with thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links -4 Nos. |
| 576 | 63A/FP/25kA MCCB with thermomagnetic release type with S/C & O/L protection with extended front rotary handle and spreader links. -1 Nos. |
| 577 | Total Cost of COMMON Panel -1 |
| 578 | Feeder Pillar Panel (Canopy Type) :- |
| 579 | Supplying, designing, manufacturing, installation, testing and commissioning in correct alignment position, effecting proper connection of all incomer and outgoing of Feeder Pillar panel for external Lighting of 14 SWG CRCA sheet (2 mm) steel IP – 54 floor mounting cubical type LT Panel in canopy shape suitable for operation on 415V, 50Hz, 3 Ph. AC supply and fault level 25 KA with front operated construction including separate fabrication arrangement for fixing M.C.C.B. |
| 580 | The sheet steel under go minimum 7 tanks treatment followed by finishing powder coating of minimum 60 micron thickness duly compartmentalized with locking arrangement duly fixed on Base Channel Size – 50 mm x 50 mm x 4 mm having accessories mounted inside the cubical panel, earthing with 2 Nos. earth studs. The panel shall have type test certificates with short circuit and IP protection (C.P.R.I. Test). Detail drawings and SLD shall be provided at the time of work order. |
| 581 | All openings shall be covered by soft rubber gasket, enclosure shall be galvanized. Panel shall have suitable cable entry from bottom and suitable arrangement for multi runs aluminum cables for all MCCB. |
| 582 | The panel shall have type test certificates with short circuit and IP protection (C.P.R.I. Test) |
| 583 | Aluminum Bus Bar for Panel :- |
| 584 | Bus bar shall be suitable for 200A, TPN busbar chamber of suitable length with (E91EWP) Eletrolytic Aluminum busbars. All busbars and interconnections shall be of suitable size Aluminum busbar, current density of Aluminum shall not be more than 0.8 Amps/sq.mm cross sectional area of Bus Bar with removel gland plates, cable glands, at sending and receiving ends, encluding connections with outgoing feeders complete in all respect and all interconnections shall be made with 2.5, 4 and 6 sq.mm. PVC Cu.wire. Cost of Enclosure with Al bus bar, connection PVC wires, etc. The Aluminium bus bar shall be with heat shrinkable PVC Slived Red,Yellow,Blue & Black as (RYB & N ) after temperature and incloser derating maximum allowable temp.of bus bar shall be 90 degree C. |
| 585 | SLD will be submitted by the contractor for approval to Engineering Incharge/Consultant before submitting the APAFCR Panel drawing. Based on approved SLD, contractor will provide the GA drawing of External Feeder Pillar Panel. Inspection of the External Feeder Pillar Panel shall be carried out at Panel Builder's factory by the Consultant before final delivery. |
| 586 | 1 Set of Cost of Fabrication Part Feeder Panel for External Lighting & busbar system, in CRCA Sheet Steel enclosure (IP-54) without any components. |
| 587 | The panel builder shall have type test certificates with short circuit and IP protection (C.P.R.I. approved) |
| 588 | Location :- In Campus |
| 589 | Bill of Material in External Feeder Pillar Panel :- |
| 590 | INCOMER:- |
| 591 | 1 no. 125A/FP/25KA/ MCCB thermomagnetic release type with Rotary Handle & Spreader links. |
| 592 | 3 set of CT 125/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. Make- Matrix/Kappa/L&T |
| 593 | 1 Set of Digital Multifunction Meter |
| 594 | 3 Sets of Phase indicating light shall be protected by 2 Amps SP MCB's for incomer. |
| 595 | OUT- GOING |
| 596 | 25A FP MCB C-Series.-6 Nos. |
| 597 | 32A DP MCB C-Series.-2 Nos. |
| 598 | 32A DP MCB C-Series.-2 Nos. |
| 599 | 4 Sets Power Contactor NO NC of three phase of suitable rating. |
| 600 | 4 Sets. Single channel Digital Time Switch. |
| 601 | 4 sets. Four pole two way Lexic changeover with centre off 440V AC 32 to 40A to be used in case of timer failure to by pass the timer. |
| 602 | Total Cost of Feeder Pillar Panel for External Lighting |
| 603 | Providing and fixing of PVC/XLPE indulated PVC sheathed heavy duty , aluminium armoured cable of grade 1.1KV as per IS 1554 (Part-1), etc. as required. Make:- Havells / Finolex / Polycab/KEI. |
| 604 | 2 Core 6 Sq.mm. XLPE Al. Ar. Cable 1.1kV. |
| 605 | 4 Core 10 Sq.mm. XLPE Al. Ar. Cable 1.1kV. |
| 606 | 3.5 Core 25 Sq.mm. XLPE Al. Ar. Cable 1.1kV. |
| 607 | 3.5 Core 35 Sq.mm. XLPE Al. Ar. Cable 1.1kV. |
| 608 | 3.5 Core 50 Sq.mm. XLPE Al. Ar. Cable 1.1kV. |
| 609 | 3.5 Core 95 Sq.mm. XLPE Al. Ar. Cable 1.1kV. |
| 610 | 3.5 Core 120 Sq.mm. XLPE Al. Ar. Cable 1.1kV. |
| 611 | 3.5 Core 185 Sq.mm. XLPE Al. Ar. Cable 1.1kV. |
| 612 | 3.5 Core 300Sq.mm. XLPE Al. Ar. Cable 1.1kV. |
| 613 | Supply of 7 Meter Height Octagonal Hot Dip Galvanized pole (BOP 7030) with top dia 70mm bottom dia 130mm & made of 3 mm thickj sheet, base plate dimensions 200x200x12mm (L X B X T) including suitable sizes of foundation bolts all complete as required. (Without ARM) Make:- RR Ispat/ Transrail/ Valmount/Bajaj. |
| 614 | Installation, Testing and commissioning of 7 Meter Height Octagonal Hot Dip Galvanized pole with suitable Tools and Plants, wiring of Luminaires with all materials and construction of shallow foundation, with M25 grade concrete considering safe soil bearing of 10T/mtrs Sq. |
| 615 | Supply fitting, fixing of Double Arm (1.5 Mtr. Long) suitable for 70 mm Top.Make:- RR Ispat/ Transrail/ Valmount/Bajaj. |
| 616 | Supply of Conical pole of height 3 mtr with top dia 75 mm ,bottom dia 105+_5 mm , sheet thickness 3 mm and base plate 200 x200x 12 mm with PU painted in different colour as required. Top.Make:- RR Ispat/ Transrail/ Valmount/Bajaj. |
| 617 | 250 KVA Silent D.G. Set :-250 KVA DG set with AMF Panel IS/IEC - 60034-1, IS:1460, IS:13018 :- |
| 618 | Supply, fitting, fixing, installation and testing of 250 KVA /415 Volts, 3 Ph. Silent Diesel Generator Set with AMF Panel confirming to IS/IEC - 60034-1, IS:1460, IS:13018 |
| 619 | The 250 KVA /415 Volts, 3 Ph. Silent Diesel Generator Set with AMF Panel shall have AC supply complete with engine (1500 RPM) and alternator with accessories including residential type silencer and fuel service tank, battery, nattery leads, battery charger with all accessories, including MCCB of suitable rating & standard set of tools and anti-vibration mounting pads, etc. The power command controller compactable with BMS, PC & PLC compelte as required, remote mointoring and data logging with digital voltage regulator through inbuilt AVR, digital governing including protection complete as required. Make:-Kiloskar/Jakson/Sterling. |
| 620 | Supply of company make acoustic enclosure for 250 KVA CPCB approved Acoustic enclosure with 80 mm MS base plate, 1.6/2 mm CRCA sheet, 50 mm thick foam / 100 mm Rock Wool Insulation, 14 surface tank treatment, dully powder coated and painted with suitable colour with integrate Fuel Tank, services door, louvers (Fresh Air / Radiator), 1020 dia residential type Silencer, dimension as per company specification, complete with following accessories :- |
| 621 | a) Fuel Tank. |
| 622 | b) Batteries, battery leads and in built battery charger. |
| 623 | c) Residential Silencers. |
| 624 | d) First fill of lube oil. |
| 625 | e) AVM Pads. |
| 626 | f) OEM Manufacured AMF Panel with 500A /FP/36kA/MCCB Type. ( with inbuilt Control Breaker ( of suitable capacity of 500A MCCB Type and all type of meters (Voltmeter, Ammeter, KW/m, Hz/m, contractor, AMF Conroller etc as required ) and all other protections. |
| 627 | In above supply item following work are also included :- i) Installation, fitting, fixing, testing and commissioning of the same. ii) Installation of Exhaust system for D.G. Set shall be as per Central & State Pollution Board Norms along (C.P.C.B.) with iron structure i.e. 5 mtr. above the height of nearest building. If this will be in the scope of the contractor then charges shall be extra and that will be the actual. iii) Test run for D.G. Set without load and with load (part wise ) at least 10-12hrs each time. |
| 628 | Supply of inbuilt Control Breaker ( of suitable capacity of 500A,36KA/FP MCCB ,) with separate AMF Panel having 500A F/P MCCB Microprocessor release type with spreader links & extended rotary handle, AMF Controller, F/P NO NC 500A Contactor, and all type of meters (Voltmeter, Ammeter, KW/m, Hz/m) and all protection indications with alarm and with suitable arrangement for 2 R 185 Sq mm 3.5 Core Al. Ar. Cable etc as required. |
| 629 | Cost of 250 KVA DG set with AMF Panel |
| 630 | Supplying, installation, testing and commissioning of Grid interactive roof top solar photo voltaic power generation system including space frame. |
| 631 | Supplying and fixing of 20 Amps, 240 Volts, SPN Industrial type, socket out lets, with 2 pole and earth, metal enclosed plug top alongwith 20 Amps.\\"C\\" curve, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the shocket 0ut let and complete with connections, testing and commissioning etc. as required. |
| 632 | Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 633 | 1.1 KV Cable End Termination:-Supplying and making indoor cable end termination with brass double compression gland and aluminium lugs for following size of PVC insulated XLPE Al. Ar. Cable of 1.1 KV grade as required. |
| 634 | 2 X 6 sq. mm (19mm) |
| 635 | 4 X 10 sq. mm (25mm) |
| 636 | 4 X 16 sq. mm (28mm) |
| 637 | 3½ X 25 sq. mm (28mm) |
| 638 | 3½ X 35 sq. mm (32mm) |
| 639 | 3½ X 50 sq. mm (35mm) |
| 640 | 3½ X 95 sq. mm (50mm) |
| 641 | 3½ X 120 sq. mm (45mm) |
| 642 | 3½ X 185 sq. mm (57mm) |
| 643 | 3½ X 300sq. mm (70mm) |
| 644 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc. as required |
| 645 | 100 mm dia |
| 646 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 647 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 648 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 649 | Providing and fixing of PVC/XLPE indulated PVC sheathed heavy duty , aluminium armoured cable of grade 1.1KV as per IS 1554 (Part-1), etc. as required. Make:- Havells / Finolex / Polycab/KEI. |
| 650 | 3.5 Core 35 Sq.mm. XLPE Al. Ar. Cable 1.1kV. |
| 651 | 3.5 Core 50 Sq.mm. XLPE Al. Ar. Cable 1.1kV. |
| 652 | 30 KVA online UPS three phase input and three phase output power sysyter of input voltage range 360V/380V/400V/485V AC.frequency range 40HZ tp 60Hz +-10% output voltage range 415 . |
| 653 | SITC of MS Battery Rack suitable for 40 to 50 UPS Battery Installation. |
| 654 | SITC of 65 AH Flat type Sealed Maitanace Free (SMF) Battery with 24 months replacement warranty. IS:1652:1991. |
| 655 | 2 Tr. 5 Star Split A.C (Inverter Type) I91391-part-II,Make-CATEGORY \\"B\\" (Mitsubishi heavy industries and O'GENERAL) |
| 656 | 5 KVA WALL MOUNTED STABLIZER |
| 657 | OUTDOOR STAND FOR 2 TR SPLIT AC |
| 658 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 659 | 1 run of Cable |
| 660 | 1.1 KV Cable End Termination:-Supplying and making indoor cable end termination with brass double compression gland and aluminium lugs for following size of PVC insulated XLPE Al. Ar. Cable of 1.1 KV grade as required. |
| 661 | 3.5 Core 35 Sq. mm. (32mm) |
| 662 | 3.5 Core 50 Sq. mm. (32mm) |
| 663 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc. as required |
| 664 | 100 mm dia |
| 665 | Supplying and fixing of 20 Amps, 240 Volts, SPN Industrial type, socket out lets, with 2 pole and earth, metal enclosed plug top alongwith 20 Amps.\\"C\\" curve, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the shocket 0ut let and complete with connections, testing and commissioning etc. as required. |
| 666 | Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 667 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable trays (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 668 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 669 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 670 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (Galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 671 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 672 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 673 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (Galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 674 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 675 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 676 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Cross member\\" (Galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 677 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 678 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 679 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Reducer\\" (Galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 680 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 681 | 300 mm width X 50 mm depth X 1.6 mm thickness Please Enable Macros to View BoQ information |
| 682 | 300 mm width X 50 mm depth X 1.6 mm thickness Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail