| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required. (As per TSR, 2021 Sl.201) |
| 2 | Short Point |
| 3 | Medium Point |
| 4 | Long Point |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required.(As per TSR, 2021 Sl.203) |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required.(As per TSR, 2021 Sl.204) |
| 7 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.(as required.(As per TSR, 2021 Sl.205) |
| 8 | 2x1.5 sq.mm: |
| 9 | 2x2.5 sq.mm: |
| 10 | 2x4 sq.mm: |
| 11 | 2x6 sq.mm: |
| 12 | Wiring for Circuit/Sub-main wiring with the following sizes of PVC insulated copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required.(As per TSR, 2021 Sl.503) |
| 13 | 1 X 1.5 sq mm |
| 14 | 1 X 2.5 sq mm |
| 15 | Providing earthing system with maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminal size 32mmx 6mm including accessories with masonry enclosure of CI cover plate size 12\\"x 12\\" having locking arrangement including CC works etc as required.(As per TSR, 2021 Sl.717) |
| 16 | Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or in existing G.I / PVC / Polythene pipe for loop earthing as required. (As per TSR, 2021 Sl.707) |
| 17 | Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required. (As per TSR, 2021 Sl.710) |
| 18 | Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required.( As per TSR, 2021 Sl-602) |
| 19 | 19/20 mm dia |
| 20 | Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. (As per TSR, 2021 Sl.712) |
| 21 | Supply and fixing of 32mm x 6 mm GI strip on walls/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. (As per TSR, 2021 Sl.713) |
| 22 | Supply and fixing of the following sizes GI prong with necessary nuts & bolts etc as required grouted on roof for Lightning protection. (As per TSR, 2021 Sl.716) |
| 23 | G.I Prong 1000 mm long |
| 24 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. (As per TSR, 2021 Sl.609) |
| 25 | Electronic 4 step mini fan regulator. |
| 26 | Buzzer call bell (1M) |
| 27 | Supplying and fixing of the following ratings switch disconnector fuse unit(main switch)made of sheet steel enclosure with all accessories including drilling holes on the board/MS clamp and necessary connection etc. as required.(As per TSR, 2021 Sl.1202) |
| 28 | 32 amps 240 volts DP (rewireable) |
| 29 | Supplying and fixing of powder coated sheet steel enclosure on surface/recess, suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. (As per TSR, 2021 Sl.1208) |
| 30 | 4 way MCB DB (double door). |
| 31 | 2+6 / 8 way MCB DB (single door). |
| 32 | (2+10) / 12 way SPN MCB DB (single door). |
| 33 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required. (As per TSR, 2021 Sl.1215) |
| 34 | 6 to 32 amps SP MCB. |
| 35 | 6 to 32 amps DP MCB. |
| 36 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies, shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated copper conductor cable(FR) ( ISI marked BEE 1 star / minimum service value 4.0) (As per TSR, 2021 Sl.802) |
| 37 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required. (As per TSR, 2021 Sl.817) |
| 38 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required. (As per TSR, 2021 Sl.821) |
| 39 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required. (As per TSR, 2021 Sl.831) |
| 40 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt)(As per TSR, 2021 Sl.1101) |
| 41 | Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp) |
| 42 | Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser. |
| 43 | Supplying and fixing of following luminaries complete with necessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours)(As per TSR, 2021 Sl.1001) |
| 44 | Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp) |
| 45 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required. (As per TSR, 2021 Sl.1103) |
| 46 | 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt) |
| 47 | 12 watt LED retrofit lamp with polycarbonate body and aluminium heatsink . |
| 48 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt). (As per TSR, 2021 Sl.1102) |
| 49 | 45 watt LED street light fixture with integral driver and secondary lens (IP 66). |
| 50 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) (As per TSR, 2021 Sl.1509) |
| 51 | Supplying & installation of astronomical time switch including necessary connection etc as required. (As per TSR, 2021 Sl.1513) |
| 52 | Supplying & installation of following power contactors including necessary connection etc as required. (As per TSR, 2021 Sl.1514) |
| 53 | 3 pole 9 amps (AC3) power contactors with 1NO+1NC Aux. Contact. |
| 54 | Supplying and laying of the following XLPE insulated PVC sheathed alluminum armoured cable including connection etc as required. (As per TSR, 2021 Sl.1301) |
| 55 | 3 core 6 Sq mm. |
| 56 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable. (As per TSR, 2021 Sl.1405) |
| 57 | 1.5 sqmm - 4 sqmm Cable. |
| 58 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer.(As per TSR, 2021 Sl.1510) |
| 59 | Drawing of armoured/un-armoured cable with proper saddling etc as required. (As per TSR, 2021 Sl.1511) |
| 60 | Supplying and fixing of MS frame made of (25 x 25 x 5)mm MS angle with necessary support by (40 x 6)mm MS flat and 10 mm thick boiled plywood on top, grouted on wall with 4 nos leg(25x25x5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required. (As per TSR, 2021 Sl.1502) |
| 61 | Supplying and Laying of 40 mm dia ( Medium guage) GI Pipe for road crossing of Cable. (as per agreement No. 18/EE-IED/AMB/2024-25) |
| 62 | Supplying of 25 cm long ‘L’ hook made with 40mm x 6mm MS flat and fixing with necessary fasten nuts including finishing, painting etc as required. (As per TSR, 2021 Sl.1508) |
| 63 | Supplying and fixing of compound lighting pole fabricated with GI pipe ISI marked(medium Gauge) having three sections- 80mm dia upto 3 mtr long(bottom; out of which 1m will be inside the foundation base) 65mm dia upto 2 mtr long(middle), 50mm dia upto 1 mtr long (top) and 1 no. arm of 40mm dia 1.5 mtr long , thick MS sheet foundtation plate welded at bottom i/c welding of 2 nos earth stud and drilling holes for taking wire,fitting of pole cap etc complete with erection of the same in cc foundation i/c excavation and refilling, painting the GI pole with allu. approved shade of enamel paint(2 coats) over one coat of red oxide etc as required. as per the direction of Site-Engineer. (as per agreement No. 18/EE-IED/AMB/2024-25) Please Enable Macros to View BoQ information |