| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group A |
| 2 | Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 3 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 4 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.(i) 125 A,36 KA,FPMCCB |
| 5 | 250 A,36KA,FPMCCB |
| 6 | 400 A,50 KA,FPMCCB |
| 7 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (i) 8 way (4 + 24), Double door |
| 8 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (i) 40 Amp |
| 9 | 63 Amp |
| 10 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(i) 100 Amp |
| 11 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 12 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 13 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 14 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required. |
| 15 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 16 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 17 | Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connectionswith 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim (i) 12 -15 watt |
| 18 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP- 66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (i) 50 Watt |
| 19 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.(i) 1200 mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 20 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required (i) 3½ X 35 sq. mm (32mm) |
| 21 | 3½ X 95 sq. mm (45mm) |
| 22 | 3½ X 185 sq. mm (57mm) |
| 23 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re- filling etc as required |
| 24 | Supplying and Fixing of 20/22 W LED Batten, type 6500k luminaire coolday, 4 feet Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient suitable for surface/Pendant mouting i/c all accessories |
| 25 | Supplying and Fixing of 10 Watt LED Batten (for Mirror light) , type 6500k luminaire coolday, Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient suitable for surface/Pendant mouting i/c all accessories |
| 26 | Supply, installation, testing and commissioning of fresh air fan with louver shutter 250 mm sweep in the existing opening including making the hole to suit the size of the above fan and making good the damage, connection, testing , commissioning etc as required. |
| 27 | Providing and fixing of 9 / 10 Watt, 3000-6500 K LED Bulb |
| 28 | Providing of Decorative wall light fixture made up of Polycarbonate, with for 9/10 W retrofit LED Lamp B22 base. Make Havells , (Model - CITY 3) |
| 29 | Providing and Laying of one number PVC insulated and PVC sheathed / XLPE power cable aluminium conductor, XLPE Insulated, armoured power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. ( 3.5x 35 sqmm Aluminium conductor armoured cable ) |
| 30 | Providing and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. ( 3.5x 35 sqmm Aluminium conductor armoured cable ) |
| 31 | Providing and Laying of one number PVC insulated and PVC sheathed / XLPE power cable aluminium conductor, XLPE Insulated, armoured power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. ( 3.5x 95 sqmm Aluminium conductor armoured cable ) |
| 32 | Providing and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. ( 3.5x 95 sqmm Aluminium conductor armoured cable ) |
| 33 | Providing and Laying of one number PVC insulated and PVC sheathed / XLPE power cable aluminium conductor, XLPE Insulated, armoured power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. ( 3.5x 185 sqmm Aluminium conductor armoured cable ) |
| 34 | Providing and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. ( 3.5 x 185 sqmm Aluminium conductor armoured cable ) |
| 35 | Providing and fixing of 600 x 600 mm x 400 mm joint box made out of 2 mm thick CRCA sheet floor moounted with 600 mm x 400 mm frame and 450 mm long 04 Nos legs made out of 35 mm x 35 mm x 5 mm thick angle, outside door type, dust proof front door openable having hinged cover, lockable gate and rain proctected canopy cover at top complete with 4 Nos bus bars of 300 Amp capacity feeder pillar shal be suitable for three phase, 415 volt AC supply and including civil matterials for making foundation of joint box etc as required. |
| 36 | Desigining/Fabrication/ Supply/ installation/ testing and commissioning of compartmentalised type outdoor feeder piller, double door made out of 2 mm thick CRCA powdered coated sheet having 300 amps, 04 nos insulated aluminium bus bars and to accommodate following accessories, front & back openable door with proper hinges, R-Y-B LED indicators and P & F of internal connection with suitable size of copper wires, following accessories & suitable angle iron frame with 800 mm long legs made out of 50 mm x 50 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation, arrangement for incoming & outgoing cables, cable termination, earthing, locking, interconnection etc. as required. (CPRI Approved builder). The feeder pillar should have Indicating lamp (LED type) 22.5 mm 230 volt AC Red, Yellow and blue - 03 nos, CT Ratio (Amp) 100/05, accuracy class 1, burden 05 VA -03 nos, Digital Multifunction meter (VAF + PF) make Legrand- 01 No, Earth studs on both side. The feeder pillar should have provision to acccomodate 250 Amp , 4 Pole MCCB-1 No as incomer, 125 Amp, 4 Pole MCCB-12 Nos in each feeder pillar. The design of the feeder pillar should got approved from Competent Technical authority before fabrication.(The Fp should be of approx size 1200 x 2100 x 400 mm deep =3 Nos (area of Feeder pillar is taken in sq mm face area) |
| 37 | Desigining/Fabrication/ Supply/ installation/ testing and commissioning of compartmentalised type outdoor feeder piller, double door made out of 2 mm thick CRCA powdered coated sheet having 500 amps, 04 nos insulated aluminium bus bars and to accommodate following accessories, front & back openable door with proper hinges, R-Y-B LED indicators and P & F of internal connection with suitable size of copper wires, following accessories & suitable angle iron frame with 800 mm long legs made out of 50 mm x 50 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation, arrangement for incoming & outgoing cables, cable termination, earthing, locking, interconnection etc. as required. (CPRI Approved builder). The feeder pillar should have Indicating lamp (LED type) 22.5 mm 230 volt AC Red, Yellow and blue - 03 nos, CT Ratio (Amp) 100/05, accuracy class 1, burden 05 VA -03 nos, Digital Multifunction meter (VAF + PF) - 01 No, Earth studs on both side. The feeder pillar should have provision to acccomodate 400 Amp , 4 Pole MCCB-1 No as incomer, 250 Amp, 4 Pole MCCB- 08 Nos and 125 Amp, 4 Pole MCCB- 04 Nos in each feeder pillar. The design of the feeder pillar should got approved from Competent Technical authority before fabrication.(The Fp should be of approx size 1200 x 2100 x 400 mm deep =1 No (area of Feeder pillar is taken in sq mm face area) |
| 38 | Supplying and fixing Single Phase energy meter 1P , 5-45 Amp, CI 1DIN Rail Mountable in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make -Havells /L& T /C&S or similar approved by Engg-incharge |
| 39 | Laying of cable without cutting the road by making the provision through bokki or any other mean below up to the depth of 0.75 mtr etc. as required. |
| 40 | Dismentling of old surface / recessed wiring and distribution board of buildings/ground and making the damage good etc as required as per direction of engg- in charge. Please Enable Macros to View BoQ information |