| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of Work : Repairs to roof treatment and sunken portion in Bldg No. P15/1 to 04, P-16/1 to 04, P-101 to P-120, P-149 to P-156, P-24, P-26, P-70 and P-72 at Old Mil Stn Kapurthala under GE Kapurthala. Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 3 | M&L for glazed ceramic coloured tiles in vertical surfaces 450x300x7mm thick set and jointed in neat cement slurry pointed in white or colour cement to match the colour, with 10 mm thick cement screed bed (1:4) complete all as specified and directed. |
| 4 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11sqm but n.exc 0.18 Sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, with 15 mm thick cement screed bed in cement mortar (1:6) with epoxy filling in joint complete all as specified and directed. |
| 5 | Demolition of brick / block masonry built in cement mortar including all quoins, arches, pillars etc and clearing off the premises. |
| 6 | M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and directed. |
| 7 | Taking down cement plaster on brick work or concrete surfaces including racking out joints all as specified. |
| 8 | M&L for rendering 15mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
| 9 | M&L for 15mm thick rendering in cement mortar 1:4 on brick work or concrete surfaces with water proofing compound finished even and smooth etc; complete all as specified and directed. Note:- WPC shall be paid separately. |
| 10 | M&L for 10mm thick rendering in cement mortar 1:3 on brick work or concrete surfaces finished even and smooth w/o using extra cement in ceiling etc; complete all as specified and directed. |
| 11 | M&L for TMT bars 10mm dia and over cut to length bent to shape required, including cranking, bending hooking etc; and binding with mild steel binding steel wire (annealed) not less than 0.9mm dia all as specified and directed. |
| 12 | Taking down chowkats or framed with shutter (with out taking off shutters from the frame) area not exc 1.50 sqm each complete all as specified and directed. |
| 13 | S&F of solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening complete all as specified and directed. |
| 14 | S&F of factory made solid panel PVC moulded door shutter with particle board core 28 to 30mm thick (stiles) with 2,4 or 6 raise panel design with 2mm thick moulded pvc sheet on the front face and 2mm plain colour pvc sheet on back face supplying and fixing in frame at site as per specification all as specified and directed. |
| 15 | S&F of alumunium hinges for PVC door shutter, size of hinges in 100mm complete all as specified and directed. |
| 16 | S&F of aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt in 200mm complete all as specified and directed. |
| 17 | S&F of extruded aluminium alloys handles frabicated type anodized of size 150mm long complete all as specified and directed. |
| 18 | S&F of steel ventilators fixed type of size 50 x 20mm and 1mm thick with glazing bars etc; complete all as specified and directed. |
| 19 | S&F of steel window 1.25mm thick box type ( primer coated) ERW hollow P section of size 60mm x 25mm single rebated comprises glazed Skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T- Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- Section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC ( 1:3:6) type C-1 Four Nos for each window) including following fitting welded to frame shutter:-(a) Handles of Z Sec 20mm x 100mm long (b) Stopper – 01 No per leaf (c) Cleat 55mm long of hollow square 15mm x 20mmx63mm welded to hinges – 01 No per leaf (d) Mild steel Pintal hinges of size 75mmx75mmx12mm-02 Nos per leaf (e) Grills made out of MS square bar 12mm dia welded to FI frame complete all as specified and shown on drawings.Note:- (i) Glass and painting shall be measured and paid separately under appropriate item(ii) Irrespective of whatever shown on drgs, MS gills shall be of 12mm dia MS square complete all as specified and directed. |
| 20 | S&F of steel window 1.25mm thick box type ( primer coated) ERW hollow P section of size 60mm x 25mm single rebated comprises gauged Skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T- Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- Section of size 60x25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC ( 1:3:6) type C-1 Four Nos for each window) including following fitting welded to frame shutter:- (a) Mild steel hold fast,150mm long of 12mm Square bar made to shape – 04 Nos per window (b) Handles of Z Sec 20mm x 100mm long (c) Stopper – 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mmx63mm welded to hinges – 01 No per leaf (e) Mild steel Pintal hinges of size 75mmx75mmx12mm-02 Nos per leaf (f) Grills made out of MS square bar 12mm dia welded to FI frame complete all as specified and shown on drawings.Note:- Wire mesh and painting shall be measured and paid separately under appropriate item etc complete all as specified and directed. |
| 21 | S&F of stainless steel wire cloth 0.56mm nominal dia of wire and avarage width of aperture 1.00mm and fixed with tinned tacks/screws with bolts incl leaping wooden complete all as specified and directed. |
| 22 | M&L for preparation of old steel surfaces of any description over 10cm girth or width not otherwise described and applying two coat of synthetic enamel paint over red oxide primer all as specified and directed. |
| 23 | M&L for preparation of new steel surfaces of any description over 10cm girth or width not otherwise described and applying two coat of synthetic enamel paint over red oxide primer all as specified and directed. |
| 24 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distermper over a coat birla white putty complete all as specified and directed. |
| 25 | M&L for preparation of new plastered surfaces of walls and applying two coats of exterior emulsion paint including 2mm wall care putty complete all as specified and directed. |
| 26 | M&L for preparation of new plastered surfaces of ceiling and applying two coats of whitewash on ceiling over a coat of birla white putty complete all as specified and directed. |
| 27 | M&L for preparation of old plastered surfaces of ceiling and applying two coats of whitewash over a 1mm thick white putty complete all as specified and directed. |
| 28 | M&L for preparation of old plastered surfaces of walls and applying one coats of oil bound distermper over one coat of birla white putty 2.00mm thick complete all as specified and directed. |
| 29 | M&L for preparation of old plastered or unplastered decorated surfaces of walls or cornics by complete removeal of existing treatment by applying water and scrapping of entire thickness of exsting treatment with using steel scraper and thereafter applying two coat of exterior emuslion paint and including 2mm thick wall care putty to achieve smooth finish over a coat of appropriate primer complete all as specified and directed. Note- Exterior emulsion paint to be done by Roller. |
| 30 | M&L for water proofing treatment to sunken floors of kitchen, toilets, laboratories,bath and WC's etc; shall be as under:- |
| 31 | (i) Application of Two component acrylic modified cementitious coating.(a) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement litance, existing coatings and achieve a gripping profile that is clean, dry and free from litanceand any other form of surface contamination. the installation instructions in manufacturer's published literature should be strictly compiled with, including but not limited to the following:-(b) Chipping out any visible cracks in ' V- Groove' pattern as applicable. Special attention on this part cleaning of cracks and then filling those cracks with SIKA latex SBR 100 putyy/ Dr Fixit 302 SBR latex/ perma latex SBR / FOSROC Nitibond SBR latex/ Asian Paints latex as required. Final cleaning of surface with power grinder, wire brush, hair brush and vaccum pressure if required.(c) Dampen all surfaces immediately ahead of application of Acrylic modified cemetitious coating of Sika Top seal - 107/brush Bond FOSROC/ Dr Fixit/ STP/ CICO.(d) While the surface is still damp from saturation (SSD), apply one coat of acrylic modified cementitious coating of Sika Top seal- 107/ Brush bond FOSROC/ Dr fixit / STP/ CICO of viscosity as per manufacturer's instructions.(e) Apply glass fabric sheet of Sika Fab 1 / FOSROC/ Dr Fixit/ STP while the first coat is wet.(f) Once touch dry apply second coat of Acrylic modified cementitious coating of Sika Top Seal- 107/ Brush bond FOSROC/ Dr FiXit/ STP/ CICO of viscosity as per manufacturer's instructions on the entire area.(g) Second coat shall be applied after 6-8 hrs of application of previous coat and in the direction right angle to the previous coat.(h) The waterproofing coating should be taken to a height minimu 300mm above the finished floor level on the vertical surface.(j) It is essential to cure acrylic modified cementitious coating immediately after application ( minimum 6-8 hrs drying) for a minimum of 3 to 54 days to ensure full cement hydration and to minimize cracking. |
| 32 | (k) A protection plaster ( 12-15 mm thick) in cement mortar 1:3 admixed with appropriate integral water proofing compound has to be applied on the walls.(l) Providing and applying a protection screed of 50 mm thick 1:4 cement sand mortar admixed with Sika plastocrtete over the applied water proofing coating on horizontal surfaces.Admixutre for item( k&l) above : Sika Plastocrete Plus/ FOSROC/ Dr Fixit/ STP/ CICO confirming to IS 2645(m) All the corners and joints should be pretreated with elastic waterproofing sealing tape with a woven bonding mesh on each surface and an elastic expansions zone in the centre of make Sika Seal Tape S/FOSROC/Dr Fixit/STP.(n) The membrane has to be protected in accordance with the manufacturer's recommendations until placement of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accordance with manufacturer's recommendations.(o) waterproofing treatment has to be carried out through applicators authorised.(ii) All the joints of pipesand traps within sunken portion shall be selaed properly by Epoxy sealant.(iii) All CI traps in sunken slabs to be enclosed with PCC 1:1.5:3 (min 15cm) all - round.(iv) The sunken portion shall be filled with PCC 1:5:10 type E-2 (using 40 mm stone aggregate) complete all as specified.(v) Providing drainage spout pipe GI 40mm dia bore light grade upto outside of outer wall ( Approx 450mm to 600 mm long) including cutting to existing wall and making good the disturbed surface complete all as specified and directed.(vi) Providing 25mm thick cement concrete 1:2:4 type B-0 using 12.5 mm grade stone aggregate as in flooring for laying floor finish all as specified.Note :- Item (iv),(v) & (vi) above shall be measured and paid seprately. |
| 33 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 34 | M&L for providing GI pipe heavy class of dia 40mm complete all as specified and directed. |
| 35 | M&L for PCC (1:5:10) type E2 using 40mm graded aggregate thick as in mass concreting, filling, sub base complete all as specified and directed. |
| 36 | M&L for PCC type B-0 (1:2:4) (12.5mm stone graded aggregate), 40 mm thick as for receiving top finishing layer of ceramic tiles for sunken portion finished even and smooth etc complete all as specified and directed. |
| 37 | Taking down GI tubing & connection 15mm dia laid in floor / trenches or fixed to walls complete all as directed. |
| 38 | S&F of tubing 15mm dia high density polyethylene (HDPE) pipes of pressure rating 6 kgf/sq. cm complete fixed to walls and ceiling or laid in floors. |
| 39 | Taking down GI tubing and connection 20mm dia laid in floor / trenches or fixed to walls complete all as directed. |
| 40 | S&F of tubing 20mm dia high density polyethylene (HDPE) pipes of pressure rating 6 kgf/sq. cm complete fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 41 | S&F in repairs 15 mm bore CP bib taps fancy type cast copper alloy with crutch or butter fly handle screwed down for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 42 | S&F in repairs 15mm dia stop/angle valve, CP cast copper alloy with crutch or butterfly handle. Screwed down high pressure, screwed both ends for iron pipe and fixed complete all as directed |
| 43 | S&F in repairs vitreous china squatting pan orissa pattern wash down water closet of size 580x440 mm, white, with integral foot rests complete fixed in repairs with P or S trap, PVC flushing cistern low level of Make 10 ltrs capacity including brackets for flush tank, PVC flush pipe and all necessary fittings etc; complete all as specified and directed. |
| 44 | S&F in repairs PVC(SWR) floor trap with grating and diameter of outlet 75mm including jointing to waste pipe fixed with solvent cement complete all as specified and directed. |
| 45 | S&F in repairs fancy type chromium plated stop valves with long shank and cup (concealed type) cast copper alloy screweddown high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed for bore fof size 15mm complete all as specified and directed. |
| 46 | S&F in repairs shower rose 100mm with cp arm of chromium plated any colour or fixing with 15mm pipe (minimum weight 40gm) complete all as specified and directed. |
| 47 | Cutting chases pinning in brick/stone/blocks masonary in making good to facings where required and pointing in cement mortar (1:3) to ends or eges of steps, cills, sun shades, shelves, lintel etc and cutting chases for concealed water tubing or etc and making good complete all as specified and directed. |
| 48 | Taking down eaves gutters and rainwater pipes including all fittings as specified and directed. |
| 49 | Dismantling of cast iron pipe any diameter jointed with cement mortar or lead incl all fittings from wall or floors as specified and directed. |
| 50 | S&F 75 mm PVC (SWR) pipes in repair single socketed in any length with rubber ring joints fixed to walls complete all as directed. |
| 51 | S&F 75 mm PVC (SWR) pipes in repair single socketed in any length laid in floor complete all as directed. |
| 52 | S&F 75 mm PVC (SWR) bend complete all as directed. |
| 53 | S&F 75 PVC (SWR) junction single,(single T) equal or unequal complete all as directed. |
| 54 | S&F 75 PVC (SWR) junction double,(double T) equal or unequal complete all as directed. |
| 55 | S&F 110 mm PVC (SWR) pipes in repair single socketed in any length with rubber ring joints fixed to walls complete all as directed. |
| 56 | S&F 110 mm PVC (SWR) bend with complete all as directed. |
| 57 | S&F 110 PVC (SWR) junction single,(single T) equal or unequal complete all as directed. |
| 58 | S&F 110 PVC (SWR) junction double,(double T) equal or unequal complete all as directed. |
| 59 | S&F 75mm PVC(SWR) vent cowl complete all as directed. |
| 60 | S&F of new rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top), ISI marked,white coloured, hoisted & fixed in position , capacity 500 litres, including dismantling of unserviceable tank and removing from site complete all as specified and directed. |
| 61 | S&F in repair GI pipe heavy class of dia 40mm for overflow of water tanks including necessary bends and connection with water tank complete all as specified and directed. |
| 62 | S&F in repair gunmetal globe and gate valve with iron welded hand secrewed both and for iron pipe 20mm fixed in repairs complete all as specified and directed. |
| 63 | S&F in repair gunmetal globe and gate valve with iron welded hand secrewed both and for iron pipe 15mm fixed in repairs complete all as specified and directed. |
| 64 | S&F in repairs ball valves 20mm high pressure of PTMT with epoxy coated aluminium rod and high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) complete all as specified and directed. |
| 65 | Dismantling of brick tiles or terracing tiles laid bedded and pointed in cement mortar in single layer on roofs as directed. |
| 66 | Demolition of mud in roof any thickness including plastering & leeping removed as directed. |
| 67 | M&L for rendering 10mm thick cement mortar 1:3 on concrete surface even and smooth with waterproofing compound as directed.Note :- WPC to be measured and paid seprately |
| 68 | Supply only integral water proofing compound. |
| 69 | M&L for preparation of newly plastered surface making surface completely dry and applying a coat of bitumen primer @ 0.40 ltr/sqm and after drying of primer apply APP modified water proofing membrane with non woven polyster reinforcement 3mm thick superior multipolymericweighing not less than 3kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene (MHHDPE) film consisting of five layers with a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm under and over the APP membrane laid with torching application to the surface complete and sealing the side as well as end laps (overlaps should not be less than 10 cm) complete all as specified and directed. |
| 70 | M&L for 40mm thick brick tiles laid on 15mm screed bed in cement mortar 1:3 with jointing and pointing in cement mortar (1:3) mixed with 5% crude oil by weight of cement all as directed. |
| 71 | - ditto - all as per item No. 67 above but except brick tiles including cleaning from mortar complete all as specified and directed. |
| 72 | M&L for 40 mm thick cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in PCC padding over roof slab complete all complete all as specified and as directed. |
| 73 | M&L for cement concrete Type B0 1:2:4 (12.5mm graded aggregate) in roof kerbs, rounded or chamfered edges complete all as specified and directed. |
| 74 | M&L for preparation of affected concrete and steel surface as in ceiling of roof slab, beams by cleaning with metallic wire brush scrupiously and carrying out the following operations stepwise:(i) Applying rust remover solution on steel bars by using cotton waste swab or by brush and leave the surface for 15-30 minutes. Remove the loose rust particles by srcubbing with brush and wash the steel surface with water. (ii) Apply red oxide primer over cleaned steel surfaces.(iii) Apply epoxy bonding agent (adherent solution) over cleaned dust freed old concrete surface.(iv) Apply polymer mortar with the help of trowel in single or multilayer as an when required during application and finishing the surface even and smooth.Note:- (a) The bars which are corroded badly need to be strengthen by placing new bars by means of welding with proper splice length and will be measured and paid seprately under appropriate item.(ii) The rate of item includes necessary formwork,shuttering, scaffholding, staging etc; all as specified and directed. |
| 75 | Taking down aluminium point wiring for light, fan, bell socket, power socket etc complete including fittings and fixtures removing from site and making good disturbed surfaces of walls, floors, etc; complete all as directed. |
| 76 | M&L for point wiring for one light / fan / bell point with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor (FRLS ) 1100 Volts grade cable ( red colour cable to be used for live connection and black colour cable to be used for neutral connection ) controlled by one way switch drown through and including PVC casing caping with all accessories including 1.5 sqmm copper multistrand conductor (FRLS) 1100 Volts grade unsheathed PVC insulated ( green colour ) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box complete all as specified and as directed.Note :- Sunken box , hylam plate will be measured and paid separately |
| 77 | One light point controlled by one, one way switch all as specified and directed |
| 78 | One fan point controlled by one, one way switch all as specified and directed |
| 79 | One socket outlet 3 Pin, 5 Amp on independent board all as specified and directed |
| 80 | One socket outlet 3 Pin, 5 Amp on same board all as specified and directed |
| 81 | - ditto - all as per item No 73 here in before but 2.5 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board. |
| 82 | - ditto - all as per item No 73 here in before but 4.0 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 3 pin 15 Amp switch socket combination on independent board. |
| 83 | M&L for point wiring for one light / fan / bell point with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor ( FRLS ) 1100 Volts grade cable ( red colour cable to be used for live connection and black colour cable to be used for neutral connection ) controlled by one way switch drown through and including PVC concealed conduit with all accessories including 1.5 sqmm copper multistrand conductor (FRLS ) 1100 Volts grade unsheathed PVC insulated ( green colour ) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box complete all as specified and as directed.Note :- Sunken box , hylam plate will be measured and paid separately |
| 84 | One light point controlled by one, one way switch all as specified and directed. |
| 85 | One fan point controlled by one, one way switch all as specified and directed. |
| 86 | One socket outlet 3 Pin, 5 Amp on independent board all as specified and directed. |
| 87 | One socket outlet 3 Pin, 5 Amp on same board all as specified and directed. |
| 88 | - ditto - all as per item No 76 here in before but 2.5 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board |
| 89 | - ditto - all as per item No 76 here in before but 4.0 Sqmm P.V.C insulated un sheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board. |
| 90 | S&F in repair switch piano flush type single pole one way 6 Amp complete all as directed. |
| 91 | S&F in repair switch piano flush type single pole two way 6 Amp complete all as directed. |
| 92 | S&F in repair switch piano flush type single pole one way 15 Amp (complete all as directed. |
| 93 | S&F in repair bell push flush type 5 amp complete all as directed. |
| 94 | S&F in repair socket out let 2 in 1, 3 pin 5 Amp flush type complete all as directed. |
| 95 | S&F socket out let 2 in 1, 3 pin 15 Amp flush typecomplete all as directed. |
| 96 | M&L for ceiling rose, surface bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate, isolated body complete all as specified and directed. |
| 97 | Taking down old unsv sub main and M&L for sub main wiring with two runs of single core PVC insulated, unsheathed copper conductor, multi stranded cable of size 6.00 Sqmm 1100 volts grade drawn PVC concealed conduit of size 19/20 mm (ISI marked) including PVC accessories complete incl cutting and chasing and making good etc including one run of 6.00 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed. Note:- Two run of 6.00 Sqmm cable one run of 6.00 Sqmm cable as earth continuity conductor and one run of PVC Conduit shall be measured & paid as one unit.) |
| 98 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc; complete all as specified and directed. |
| 99 | Taking down carefully exhaust fan of any size from existing location and carrying out cleaning and servicing including painting with synthetic enamel paint by spraying, greasing and heat varnishing and refixing the same in same location/new location and connecting up and including provision of twisted three core PVC insulated flexible cord of 0.75 Sqmm copper conductor of required length from ceiling rose/connector to fan complete all as specified and directed .For the purpose of maintenance, each Exhaust fan shall be treated as an assembly of the following serviceable components ( Item number 34 to 38) :-Note:-The unserviceable parts shall be measured and paid as separately. |
| 100 | Rewinding of exhaust fan any size any description with same size wire and insulating material including replacement of suitable capacitor, ball bearing and other necessary reqd accessory for smooth functioning of fan complete all as specified and directed. |
| 101 | S&F of motor unit assembly (Including stator, rotor, shaft, bearings, and motor housing of desired capacity and material all as per sample kept in AGE E/M office, complete all as specified and directed. |
| 102 | S&F of impeller/blade assembly (Including fan blades/propeller, hub, and fastening hardware), complete all as specified and directed. |
| 103 | S&F of casing and mounting assembly (Including outer frame, mounting brackets, louvers/shutters, and fixing arrangements), all as per sample kept in AGE E/M office, complete all as specified and directed. |
| 104 | S&F of electrical assembly (Including capacitor, internal wiring, terminal connectors, and associated electrical accessories such as regulator/switch, if within scope. all as per sample kept in AGE E/M office, complete all as specified and directed. |
| 105 | S&F in repair fan capacitor 2.5 MFD complete all as specified and directed. |
| 106 | S&F in repair PVC insulated aluminium 6 Sqmm, 2 core sheathed cable complete all as specified and directed. |
| 107 | S&F in repair miniature circuit breaker (MCB) ‘B’ Curve complete all as specified and directed.(In accordance with IS/IEC 60898-1) 240 V, 50 Hz,10 kA Suitable for lighting and other domestic loads Single pole 6 to 32 Amp |
| 108 | S&F in repair PVC/Polycarbonate Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings type with back plate suitable for batten fittings complete all as specified and as directed. |
| 109 | S&F in repair PVC gang box for mounting switches 01 module, complete all as specified and directed. |
| 110 | S&F in repair PVC gang box for mounting switches 02 module, complete all as specified and directed. |
| 111 | S&F in repair PVC gang box for mounting switches 06 module, complete all as specified and directed. |
| 112 | M&L in repair cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch , socket and fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and as directed. 1 way |
| 113 | M&L in repair cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch , socket and fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and as directed. 2 way |
| 114 | M&L in repair cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch , socket and fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and as directed. 4 way |
| 115 | M&L in repair cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch , socket and fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and as directed. 6 way |
| 116 | M&L for repairing of unserviceable wiring of distribution board any type any capacity including adding new wire of same size same material, insulating properly bare joint, systematically arranging wiring using clamps , conduits , etc all as reqd , all as directed. |
| 117 | Taking down carefully geysers of capacity 25 Ltr from existing location and carrying out cleaning of inner tank with descaling compound repairing including changing of u/s components(excluding heating element thermostat), including painting with synthetic enamel paint by spraying, and re fixing the same in same location/new location complete all as specified and as directed. |
| 118 | M&L for geyser inner tank assembly including inner assembly , indicator, safety valve, multifunction valve, thermal switch, auto cut switch, gaskets, gasket, fasteners complete suitable for 25 litter including connecting electrical lead all as per sample kept in AGE E/M office complete all as specified and as directed. |
| 119 | M&L for geyser outer body made out of metal/Abs , insulating material suitable for 25 litter capacity all as per sample kept in AGE E/M office complete all as specified and as directed. |
| 120 | S&F in repair PVC flexible connecting pipe for cold/hot water 450mm ling with brass end plug complete all as specified and as directed. |
| 121 | S&F in repair LED batten tube light (4ft) for surface and pendant applications.18/ 20 watt, colour temp 3000 K 5000 K complete all as specified and as directed. |
| 122 | S&F in repair LED batten tube light (2ft) for surface and pendant applications. 8-10 watt, complete all as specified and as directed. |
| 123 | S&F in repair 12W emergency Inverter LED bulb, cool day light (6500K), rechargeable bulb with 3 hours backup, ideal for powercuts, energy efficient, B22 base all as per the direction of E/M complete all as specified and as directed. |
| 124 | S&F in repair in repair LED bulk head fitting 10 watt highly cost effective compact, ultra low energy, modern design utility bulkhead suitable for indoor and outdoor applications with IP 65 protection complete with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 complete all as specified and as directed. |
| 125 | S&F in repair MCB protected socket PCV plastic base model suitable for geyser and Acs complete unit comprising mcb and socket box of reputed make , 25 Amp, 240 volt, 50 Hz, complete all as specified and as directed. |
| 126 | S&F of plastic body exhaust fan 200 dia , rust proof body, dust protection shutter connecting lead suitable for toilet/bathroom, complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |