| Sl. No. | Item Description |
| 1 | SCHEDULE \\"A\\" Part - I (BUILDINGS & STRUCTURES WORKS)Total of Sch-'A' Part-I B/F |
| 2 | SCHEDULE \\"A\\" PART-II (SITE CLEARANCE, EXCAVATION & EARTHWORK) Total of Sch-'A' Part-II B/F |
| 3 | SCHEDULE \\"A\\" PART-III (INTERNAL WATER SUPPLY)Total of Sch-'A' Part-III B/F |
| 4 | SCHEDULE \\"A\\" PART-IV (INTERNAL ELECTRIFICATION)Total of Sch-'A' Part-IV B/F |
| 5 | SCHEDULE \\"A\\" PART-V (TELEPHONE AND CONDUIT)Total of Sch-'A' Part-V B/F |
| 6 | SCHEDULE \\"A\\" PART-VI (FIRE FIGHTING SYSTEM)Total of Sch-'A' Part-VI B/F |
| 7 | SCHEDULE \\"A\\" PART-VII (LIGHTENING PROTECTION)Total of Sch-'A' Part-VII B/F |
| 8 | SCHEDULE \\"A\\" PART-VIII (EXTERNAL WATER SUPPLY)Total of Sch-'A' Part-VIII B/F |
| 9 | SCHEDULE \\"A\\" PART-IX (EXTERNAL ELECTRIFICATION) Total of Sch-'A' Part-IX B/F |
| 10 | SCHEDULE \\"A\\" PART-X (ROAD, CULVERTS, FOOTPATH AND HARDSTANDING)Total of Sch-'A' Part-X B/F |
| 11 | SCHEDULE \\"A\\" PART-XI (SEWAGE DISPOSAL)Total of Sch-'A' Part-XI B/F |
| 12 | SCHEDULE \\"A\\" PART-XII (AREA DRAINAGE)Total of Sch-'A' Part-XII B/F |
| 13 | SCHEDULE \\"A\\" PART-XIII (EV CHARGING POINT)Total of Sch-'A' Part-XIII B/F |
| 14 | SCHEDULE \\"A\\" PART-XIV (AVIATION LIGHT)Total of Sch-'A' Part-XIV B/F |
| 15 | SCHEDULE \\"A\\" PART-XV (ARBORICULTURE)Total of Sch-'A' Part-XV B/F |
| 16 | SCHEDULE \\"A\\" PART -XVI (MISCELLANEOUS ITEMS) |
| 17 | SITE CLEARANCE & EARTHWORK |
| 18 | Removing excavated material (any type) and depositing it outside Ministry of Defence Land.Note for 15.01(i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and, at which the excavated material/ debris are to be disposed off. No extra claim what-so-ever shall be entertained on this account.(ii) This item shall be considered as per the requirement at site.(iii) All excavation earthwork covered under Sch 'A' part III to part XIII shall be measured and paid under this item. |
| 19 | Removing excavated soil exceeding 250m and n.exc. 500m and depositing where directed by Engineer in charge. |
| 20 | Removing excavated material as rocks exceeding 250m and n.exc. 500m and depositing where directed by Engineer in charge. |
| 21 | Supply, install, testing & commissioning 16 Passengers Lift suitable to serve G+6 upper floors with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories conforming to IS: 14665, simplex collective selective automatic and manual dual controlled operation with/without attendant, automatic center opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door and built in announcing system with hand set (3 Nos; one each in car, near Ground floor landing door and one with hand set in Machine room) all as specified below:- |
| 22 | (a) Capacity of Lift : 16 Passengers (b) Load capacity : 1088 Kgs (c) Speed : 1.5 mtr/sec as per OEM specification (d) Power Supply : 415 volts, 3 phase, 4 wire AC, 50 Hz (e) Type of Drive : AC variable voltage & variable frequency (f) Type of Machine : Gearless permanent magnet and directly coupled Horizontal traction machine (g) Car size (inside) : As per IS:14665(Part 3/Sec 1&2):2000 (h) Car door : Automatic Center opening with VVVF door drive opening size not less than 800mm x 2000mm, sliding type, stainless steel, sheet not less than 16 gauge having hair line finish (N-304). (j) Car enclosure : Standard manufacturing with SS frame not less than with hair line finish (N304) having stainless steel false ceiling with hair line finish internal lighting arrangement with LED light fitting complete internal ventilation system provided with concealed arial floe/cross flow fan with auto cut off system and stainless steel grill wire mesh for protection. (k) Terminal buffers : Special spring buffers (l) Door opening (Inside) : As per OEM standard (m) Counter weight shall be of cast iron as recommended by OEM. (n) Car & counter weight Guide : Guide rails of `T' Section Mild steel as per OEM design (o) Flooring : Aluminium chequered plate 5mm thick complete (p) Signals:- (i) Combined luminous hall buttons with LCD/VFD hall position indicators at all floors. (ii) Vacuum filled Display (LCD/VFD) for car position indicator of stainless steel . (iii) One No car operating panel with Luminous buttons in car . (iv) Car direction indicator in car & landing. (v) Battery operated alarm bell & emergency light (rechargeable) alongwith suitable maintenance free battery . (vi) Overload warning feature in car cabin . (vii) Fireman’s switch one No per lift to be installed at G Floor near landing door to be installed at ground floor near landing door. (viii) All signal fixture & car operating panel on hair line stainless steel face plate with hair line finish. (ix) Infra red door senser safety edges of door for entire height. (x) Built in announcing system without hand set , 2 Nos one each for car , Ground floor and machine room and with one hand set in machine room. (xi) The interior of the car should be provided with a device that audibly indicates the floor lift car has reached and indicates that car entrance/exit door is open or closed. (r) Stops & Opening : All opening on same side (s) Safety device : As per Automatic Rescue Device (ARD)/automatic landing device to be operating with maintenance free batteries for landing all as specified . (Make : OTIS/MITSUBISHI/ /SCHINDLER ) (t) Operation : Simplex collective selective Automatic operation with/without attendant (v) Machine Room : Located above the hoist way and details enclosed as per drgs . (Tenderer to inspect the same at site before quoting ) (w) Hoist-Way Constn : RCC wall constn as existing at site . Total height from G/L to slab of Machine room – As per drgs. (Tenderer to inspect the same at site before quoting) (x) ACVVVF drive shall be of make: OTIS/JOHNSON/KONE/SCHINDLER. (y) Control system shall be closed loop type. (z) Door shall have AC VVVF controlled door operator. (aa) Faceplate shape shall be Rectangular and stainless steel in Hairline Finish. (ab) Civil work : Necessary Civil work such as making good disturbed surfaces, modification to landing space to suit car size, necessary foundation for machine etc and one coat of white wash shall be applied on the lift shaft after completion of lift installation . |
| 23 | Supply, install, testing & commissioning 8 Passengers Lift suitable to serve G+6 upper floors with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories conforming to IS: 14665, simplex collective selective automatic and manual dual controlled operation with/without attendant, automatic center opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door and built in announcing system with hand set (3 Nos; one each in car, near Ground floor landing door and one with hand set in Machine room) all as specified below :- |
| 24 | (a) Capacity of Lift : 8 Passengers (b) Load capacity : 544 Kgs (c) Speed : 1.5 mtr/sec with single speed motor (d) Power Supply : 415 volts, 3 phase, 4 wire AC, 50 Hz (e) Type of Drive : AC variable voltage & variable frequency (f) Type of Machine : Gearless permanent magnet and directly coupled Horizontal traction machine (g) Car size (inside) : As per IS:14665(Part 3/Sec 1&2):2000 (h) Car door : Automatic Center opening with VVVF door drive opening size not less than 800mmx2000mm, sliding type, stainless steel, sheet not less than 16 gauge having hair line finish (N-304). (j) Car enclosure : Standard manufacturing with SS frame not less than with hair line finish (N304) having stainless steel false ceiling with hair line finish internal lighting arrangement with LED light fitting complete internal ventilation system provided with concealed arial floe/cross flow fan with auto cut off system and stainless steel grill wire mesh for protection. (k) Terminal buffers : Special spring buffers (l) Door opening (Inside) : 800mm x 2000mm or As per OEM standard (m) Counter weight shall be of cast iron as recommended by OEM. (n) Car & counter weight Guide : Guide rails of `T' Section Mild steel as per OEM design (p) Flooring : Aluminium chequered plate 5mm thick complete (q) Signals:- (i) Combined luminous hall buttons with LCD/VFD hall position indicators at all floors. (ii) Vacuum filled Display (LCD/VFD) for car position indicator of stainless steel . (iii) One No car operating panel with Luminous buttons in car . (iv) Car direction indicator in car & landing. (v) Battery operated alarm bell & emergency light (rechargeable) alongwith suitable maintenance free battery . (vi) Overload warning feature in car cabin . (vii) Fireman’s switch one No per lift to be installed at G Floor near landing door to be installed at ground floor near landing door. (viii) All signal fixture & car operating panel on hair line stainless steel face plate with hair line finish. (ix) Infra red door senser safety edges of door for entire height. (x) Built in announcing system without hand set , 3 Nos one each for car , Ground floor and machine room and with one hand set in machine room. (xi) The interior of the car should be provided with a device that audibly indicates the floor lift car has reached and indicates that car entrance/exit door is open or closed. (r) Stops & Opening :All opening on same side (s) Safety device : As per Automatic Rescue Device (ARD)/automatic landing device to be operating with maintenance free batteries for landing all as specified . (Make : OTIS/MITSUBISHI/ /SCHINDLER ) (t) Operation : Simplex collective selective Automatic operation with/without attendant (u) Two Separate earthing complete all as specified in SSR 2009 Part-I , Plate No.3 and with Aluminum strip of size 32x6mm from ground to Lift machine room to be terminated in the control panel , machine and other equipment installed in machine room. (v) Machine Room : Located above the hoist way and details enclosed as per drgs . (Tenderer to inspect the same at site before quoting ) (w) Hoist-Way Constn : RCC wall constn as existing at site . Total height from G/L to slab of Machine room – As per drgs. (Tenderer to inspect the same at site before quoting) (x) ACVVVF drive shall be of make: OTIS/JOHNSON/KONE/SCHINDLER. (y) Control system shall be closed loop type. (z) Door shall have ACVVVF controlled door operator. (aa) Faceplate shape shall be Rectangular and stainless steel in Hairline Finish. (ab) Civil work : Necessary Civil work such as making good disturbed surfaces, modification to landing space to suit car size, necessary foundation for machine etc and one coat of white wash shall be applied on the lift shaft after completion of lift installation . Note for Item No. 1 & 2:- XLPE copper conductor cable from lift panel to machine room deemed to included in item rate. |
| 25 | Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with the top edge of earth plate at depth not less than 1.5 Mtr below ground level connected to galvanised iron strip 32 X 6 mm dia by means of bolts, washers ,watering pipe 20mm dia, medium grade GI pipe,with welded funnel and wire mesh and 40mm dia medium grade GI pipe with fitting as protection pipe for strip from plate electrode to test point /plant/machineries etc. including concrete pit in PCC (1:3:6) type C-I having outer dimension 60cmx60cmx60cm and internal dimension 30cmx30cmx30cm, pre-caste RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia deformed bares @15 cm centre to centre both direction and 10 mm dia MS handle of suitable size charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as show in electrical plate No 3 of MES SSR Part I and testing complete all as specified and as directed.(Lifts - 06 No.; Fire Fighting - 04 No.; Lightning Protection - 05 No; External Electrification - 08 No, EV Charging - 04 No) |
| 26 | Supply and fix earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. of size 32 x 6 mm glvanised iron strip complete all as specified.(Lifts - 150 RM; Fire Fighting - 50 RM; Ligthning Protection - 220 RM; External Electrification - 200 RM) |
| 27 | FIRE FIGHTING |
| 28 | Material & Labour for fire hose cabinet box of size 800x600x250 mm made out of 1.6 mm thick MS sheet duly painted with two coats of red colour synthetic enamel paint over a coat of red oxide primer at externally and two coats of white colour synthetic enamel paint internally with double leafed glazed shutters (glazed with 4 mm thick glass) suitable for housing of two numbers each 15 mtr long canvas hose, single outlet landing valve, rubber hose, extinguisher and must have the legend \\"FIRE\\" painted prominently fixing arrangement on wall surface by providing MS section/flats etc., duly welded fabricated, anchored and painting to MS sections with synthetic enamel paint of fire red colour complete all as specified and directed by engineer - in- charge. |
| 29 | S & F 63 mm dia, 15 mtr long rubberised fabric reinforced rubber lined hose including gun metal male & female instantaneous coupling, hose confirming to IS : 636 type II and coupling confirming to IS 903-1975 as specified |
| 30 | Supply and fix first aid rubber hose reel drum, wall mounted swinging type fitted with 20 mm dia of 30 mtr long high pressure braided rubber hose pipe with 6 mm dia gun metal shut off nozzle and 25 mm dia inlet valve conforming to IS 884-1985 and fixing arrangement for 100 mm bore wet riser complete all as specified and directed by engineer - in- charge |
| 31 | Supply and fix fire brigade breaching unit two way, fire brigade inlet collecting head comprising of 2 Nos 63mm gun metal assembly instantaneous male inlet complete with cap and chain including 01 No non return valve 100mm dia and 01 No butter fly valve 100mm dia to be installed over 100 mm dia pipe line with necessary fittings like bends, flanged tees, tappers etc. complete all as specified and directed. |
| 32 | Supply, install, testing and commissioning of Booster pump set electrically driven of having discharge 900 LPM (ltrs/min) at 36 mtrs head CI casing, single stage, with bronze impeller, stainless steel shaft directly coupled to suitable capacity squirrel cage AC induction motor of suitable capacity to delivering adequate HP for above parameters to operate on 3 phase, 415 volts, AC, 50 Hz. The pump & motor are to be mounted on mild steel common base frame of suitable size on terrace of building with suitable PCC rigid foundation, nuts, bolts & washers with coupling guards, anti vibration rubber pads with all standard accessories including suction and delivery pipes of suitable size and adequate length with bends, tail/tappers, short pieces flanges, rubber packings, nuts bolts and washers etc., to connect suction and delivery pipes ,including electric connection by providing PVC insulated copper conductor cable alongwith earth continuity conductor of colour coaded of suitable size and adequate length from starter to motor through suitable PVC conduit complete all as specified and directed. |
| 33 | Supply,Install,Test, Commissioning of Intelligent Addressable Fire Alarm Panel, 2 Loop capacity expandable up to 5 loop with minimum 250 addresses on every loop , minimum 160 characters LCD Display, Battery Charger and Power Supply. Complete with all mounting accessories furnished with SMF type Lead Acid Battery in above panel for 24 hours backup in case of power failure, and 30 minutes in Alarm Condition complete all as specified and directed by engineer- in - charge. |
| 34 | Providing and fixing pressure flow switch (Switzer/Danfoss), 0-14 Kg/cm2 suitable to pipe dia. 150mm to 25 mm testing and commissioning etc. complete all as specified and directed by engineer in charge. |
| 35 | Supply, Install, Testing and commisioning of LT Panel , indoor type (Fire fighting) made out of 2mm thick CRCA sheet, duly powder coated, compartmental design with locking arrangements, weather and vermin proof with proper ventilation slots, IP 52 free standing floor mounted with copper busbar of suitable size for phase and neutral mounted on hygroscopic insulators comprising of the following:-i) MCCB 4 pole 63 A, incomer, 415V, 50Hz, 25 KA - 01 No.(ii) FASD starter for FF Motor-01 NosBUSBAR100 A rated copper bus bar with colour coded heat shrinkable sleeveMETERING & INDICATIONi) Ammeter,Digital type, with suitable CTs (0-100A) - 01 setii) Voltmeter, Digital type (500V) - 01 setiii) R-Y-B phase indicating lamp- 01 set(iv) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled. |
| 36 | Supply, laying, connecting, testing & commssioning 2 core;1.5 sqmm PVC insulated multistrandaded copper conductor, FRLS, armoured cable laid on surface including GI saddles, spacers at every 30 cm complete with GI junction box, lugs, glands, cable tags and ferruling and making connections to fire detectors/MCP/siren/control panel etc. complete all as specified and directed. |
| 37 | S&F GI slotted type cable trays of the following sizes using MS angle, channels, flats etc.. All MS supports used shall be given one coat of red oxide primer & 2 coats of synthetic enamel paint of approved colour of size 100 x 50 mm x 2mm complete all as specified and directed by engineer in charge. |
| 38 | Supply, installation, testing and commissioning of manual call point (MCP) for fire alarm system, wall mounted type, red color, break glass type, conforming to IS:2189 or latest, complete with necessary accessories, backbox, fixing arrangements, and termination at site, suitable for operation with addressable / conventional fire alarm system as per system design, including making good to the disturbed surfaces, connections, testing and commissioning all as directed by Engineer-in-Charge. |
| 39 | M & L Dry Chemical Powder type fire extinguisher of capacity 6 kg with genuine ABC ( MAP 50 % ) powder , IS 15683 all as specified and directed by EIC. |
| 40 | M & L for CO2 type light weight squeeze grip type fire extinguisher of capacity 4.5 kg ISI marked, IS 15683 all as specified and directed by EIC |
| 41 | M & L for Fire extinguisher water air stored type , IS 15683 , 9.0 Ltr a pressurized with nitrogen gas and filled with water with an average discharge throw of 6 m with in an average time of 31 sec with a service pressure of 31 bar complete with hose and nozzle all as specified and directed by EIC |
| 42 | M & L Fire extinguisher Mechanical foam type of rating 4A:144B,Operating Temperature +5 °C to +60 °C, IS 15683 , 9.0 Ltr Service/Max. service/Test Pressure 14 / 16 / 35 bar, verage Discharge Time 35 Sec. With average throw of 6Mtr complete with hose and nozzle complete all as specified and directed by EIC |
| 43 | S & F steek body Fire bucket made of strong iron with High Functionality, Colour – Red, Great to use outside as well for fire pits, lexible Ring handle provide a safe handling and easy way to clean-up and remove Designed with a classic finish that provides functionality for any use or a Iron coating , Fire Bucket is filled with sand or water and is used to extinguish fires Fire buckets dry sand IS 2546 complete all as specified and directed by EIC. |
| 44 | S & F Fire Escape lighting as per NBC 2016 para IV , The size and colours of the exit signs shall be in accordance with IS 9457, IS 12349 |
| 45 | S & F Fire Escape signs as per NBC 2016 para IV , The size and colours of the exit signs shall be in accordance with IS 9457, IS 12350 |
| 46 | Supply and fix suitable C.I. air release valve 32 mm dia, flanged ends ISI marked with all accessories and as per IS-14845 including 2 nos flanged joints complete with jointing material such as 3 mm thick rubber gasket, nuts, bolts, washers complete all as specified and directed. |
| 47 | EV CHARGING POINTS |
| 48 | Supply Installation and testing and commissioning of 03 phase, 04 wire, digital smart energy meter, 10A-60 Amps, 415 volts, 50 Hz accuracy class-1 single source of direct connected pre-paid mode facility BIS marked conforming to IS-16444 : 2015 (Re-affirmed 2020) with inbuilt 6LOWPAN 865-867 MHz radio frequency communucation facility having LCD type display, caliberation LED, Optical communication port, push button for scroll and having features for load disconnection through internal latching relay complying as per UC1 and data download port for last 200 temper event and and load survey for last 45 days with all standard anti tamper features including sealing facility with with self healing mesh network with default and on demand display billing data generation facility, anti-temper, micro processor and LED/LCD based circuitry complete with communication protocol DLMS as per category D2 complete all as specified and directed. Note: Meter should have following inbuilt capacity and data: (i) 30 minute instanteneous data for voltage, current, power factor, power, cumulative energy and frequency, 30 load survey data for energy, monthly billing survey for cummulative energy and max demand(ii) Meter should have connect/disconnet functionality operatable from prepaid billing software - The meter should support open communication protocol DLMS with the softwareMake: HPL/L&T or equivalent |
| 49 | Supply, install, testing and commissioning EV Charging quick charging station suitable for passenger car for test charging of input voltage of 415 Volt, Nominal output voltage of 42-58 volt DC of max output power of 6 kW IP-55 protection with LCD touch screen display including DC cable of length upto 3.5 meters complete all as specified and directed. |
| 50 | Supply and fix 16 Amps rating, 3P+N+E industrial panel mounted plug socket suitable for IP-67 degree of protection. |
| 51 | Supply and fix GI strip 25 x 4.0mm with sandles and fixing screws etc. for roof conductors with rubber & bitumen washer and including porcelain insulator on wall/ terrace for earth strip from earthing to earth test point complete all as specified and directed. |
| 52 | AVIATION LIGHT |
| 53 | Supply and fixing aviation light luminaire, LED type with integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complete all as specified and directed by Engineer-in-Charge.Cat Part No. BGAV 302 LED or equivalent in CG/BAJAJ/WIPRO |
| 54 | ROAD, CULVERTS, FOOTPATH AND HARDSTANDING |
| 55 | Material and labour for dense bituminous macadam not exceeding 50mm consolidated thickness using hot mix plant and mechanical paver with min 4% binder (paving bitumen VG-30 grade) content by weight of total mix, rolled and compacted with power rolled 8 to 10 tonnes to required cambar and gradient complete all as specified and directed by Engr-in-Charge.Note :-1. Works to be carried in places and also patch repairs to depressions over 50 mm shall be carried out under this item. Rate under this item includes for cleaning the surface of pot holes and depressions and removing of the rubbish meterials as per site requirement.2. Prepatation of mix in hot mix plant spreading by self propelling mechanical paver and rolling and compaction by set of rollers/vibrator as specified in particular specifications shall be carried out in hot mix plant which may be installed at distance as per norms but contractor shall be responsible to maintain the required temperature of mix under all conditions till it is laid and compacted. Unit rate against these items shall include for carrying out the works with deployment of these machinery for which nothing extra shall be payable and no deley in completion of work shall be acceptable.3. During transit of material from hot mix plant to site shall be covered by tarpolin/ necessary covering. |
| 56 | INTERNAL ELECTRIFICATION |
| 57 | S & F modular TV socket ISI mark incluiding flush box and cover plate with frame complete all as directed and specified. |
| 58 | S & F modular Telephone socket RJ-45 ISI marked complete incluiding flush box and cover plate with frame complete all as directed and specified. |
| 59 | S & F modular Blank plate, 1 module complete all as specified and directed. |
| 60 | S & F modular metal flush box 12 module ISI marked and flushed in wall and making good surface complete all as specified and directed. |
| 61 | External Water Supply |
| 62 | Supply Laying and testing of ductile iron pipe including specials, flanged type, class \\"K-9\\" complete of 100 mm (4\\") dia |
| 63 | External Electric Supply |
| 64 | M&L Rectangular RCC Route Marker for HT and LT line, Board Thickness: 3 inch Reinforced Concrete Cement Route Marker, colour- Red, of the hight upto 3 feet above the gorund made of PCC 1:2:4 Type B1 including excavation and PCC 1:3:6 Filling in the trench of size 0.45*0.3 Sqm and removing extra material from site all as specified and as directed. |
| 65 | Supply and laying of double wall corrugated (DWC) HDPE pipe of following sizes conforming to IS 16205 Part-24 including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc. having pressure rating not less than 450 N through trenches/UG/Wall/Floor in any type of soil for protection of electric cable complete all as specified and directed by Engineer-in-Charge. |
| 66 | 40/32 mm outer/inner dia |
| 67 | 50/38 mm outer/inner dia |
| 68 | 63/50 mm outer/inner dia |
| 69 | 90/75 mm outer/inner dia |
| 70 | Supply and errect 6 mtr octagonal pole hot dip galvanised conforms to BSEN ISO 1461, top-70, bottom 130mm, 3mm thickness, shaft material hot rolled steel plate conforms to IS 2062 BSEN 10025 or equivalent, flange/gussets/door stiffeners as per IS 2062 BSEN 10025 BRACKET, FOUNDATION BOLT M16x600mm J TYPE including necessary foundation also coping all as per specified and as directed also including provision of the following :-(a) MCB, SP, 10A, 230V, C Series, 10 KA mounted on and including 3mm thick plastic laminated sheet-01 No.(b) 4way connector, boit type having locking arrangement, weather proof and water proof control space - 01 No.Note :-(i) The rate quoted shall also be deemed to include the cost for provision of 50mm bore PVC pipe from cable trench to centre of the pole concrete. |
| 71 | Supply, installation,testing and commissioning Main LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC,50 HZ, indoor type,cubicle , floor mounted, free standing, dust and vermin proof, air ventilation with IP-54 protection fabricated out of 2mm thick CRCA sheet powder coated painting , CPRI approved,separate compartment for MCCB/metering equipments/cable gallay etc,Front and rear hinged door with locking arrangement. , copper bus bar duly covered with heat shrinkable sleeves colour coaded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing cables and connecting the outgoing MCCBs/switch gears with main bus bar by using aluminium bus links or copper conductor cable of suitable rating and connecting with terminal blocks of appropriate rating terminated by cable lugs, thimbles etc, earthing terminals, affixing danger notice plate, control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement. Angle iron of size 50mmx50mmx6mm for mounting of LT panel 40cm above floor level complete all as specified and directed by Engineer-in-Charge including comprising of following:- |
| 72 | INCOMER |
| 73 | i) ACB 4 pole 600 A, incomer, 415V, 50Hz, 36 KA - 01 No. (Incomer) |
| 74 | OUTGOING |
| 75 | i) MCCB 4 Pole,200 A, 415V, 25 KA - 2 No. |
| 76 | ii) MCCB 4 Pole, 200A, 415V, 25 KA - 1Nos. To AMF/Utility panel |
| 77 | iv) MCCB 4 Pole, 100A, 415V, 16 KA - 1 No.spare |
| 78 | BUSBAR |
| 79 | 900 A rated copper bus with colour coded heat shrinkable sleeve |
| 80 | METERING & INDICATION |
| 81 | h) AC Three phase static energy meter of accuracy class 1.0 ,3 X 240 V ,50 Hz with Backlit LCD (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power - 1 No. |
| 82 | j) Ammeter,Digital type, with suitable CTs - 03 sets |
| 83 | k) Voltmeter, Digital type - 01 set |
| 84 | l) R-Y-B phase indicating lamp- 01 set |
| 85 | m) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled. |
| 86 | Supply, installation,testing and commissioning Main LT meter panel, indoor type cubical panel board, (LT Meter Panel for building) made out of 3mm thick CRCA sheet, duly powder coated, compartmental design with locking arrangements, weather and vermin proof with proper ventilation slots, IP 54 free standing floor mounted with copper busbar of suitable size for phase and neutral mounted on hygroscopic insulators all as specified and directed by Engineer-in-Charge & comprising of the following:- |
| 87 | INCOMER |
| 88 | a) MCCB 4 Pole, 200A, 415V, 25 KA - 01 No. |
| 89 | OUTGOING |
| 90 | a) MCCB, 4 Pole 160 Amps, 415V, 25 kA - 02 Nosb) Smart Energy meters single phase, 230 V - 24 Nos for Qtrs + 02 Spare = Total 26 Nos , 01 phase , 02 wire, Digital Energy meter, 5A-60 Amps , 240 Volts, 50 Hz accuracy class-1.0 single source of direct connected prepaid mode facility BIS marked confirming IS-16444 2015(REAFFIRMED 2020) with inbuilt 4AG SIM having LCD type display . Meter should connect/disconnect functionality operable from prepaid billing software. -The meter should support open communication protocol DLMS with the software.Make of meter : HPL/L&T/Secure |
| 91 | d) MCB SPN 32 Amps- 26 No |
| 92 | BUSBAR |
| 93 | 300 A rated Copper bus with colour coded heat shrinkable sleeve |
| 94 | METERING & INDICATION |
| 95 | e) Ammeter,0-200A, Digital type, with suitable CTs - 01 set |
| 96 | f) Voltmeter, 0-500V, Digital type - 01 No. |
| 97 | g) R-Y-B phase indicating lamp- 01 set |
| 98 | h) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled. |
| 99 | Supply, installation,testing and commissioning Main LT panel, indoor type cubical panel board, (DG Utility Panel) made out of 3mm thick CRCA sheet, duly powder coated, compartmental design with locking arrangements, weather and vermin proof with proper ventilation slots, IP 52 free standing floor mounted with copper busbar of suitable size for phase and neutral mounted on hygroscopic insulators all as specified and directed by Engineer-in-Charge & comprising of the following:- |
| 100 | INCOMER |
| 101 | a) MCCB 4 Pole, 160A, 415V, 25 KA - 01 No. |
| 102 | OUTGOING |
| 103 | i) MCCB TP 63 A, 415V, 16 KA - 02 No. ( for 16 Pass Lift -01 no, Pump panel- 01 No) |
| 104 | ii) MCB TP 40 A, 415V - 05 Nos. ( for 8 Pass Lifts -02 nos , Area Security light, FF Pump) |
| 105 | iii) MCB 2 pole 32 A, 415V, 16 KA - 08 Nos. |
| 106 | BUSBAR |
| 107 | 250 A rated Copper bus with colour coded heat shrinkable sleeve |
| 108 | METERING & INDICATION |
| 109 | e) Ammeter,0-400A, Digital type, with suitable CTs - 01 set |
| 110 | f) Voltmeter, 0-500V, Digital type - 01 No. |
| 111 | g) R-Y-B phase indicating lamp- 01 set |
| 112 | h) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled. |
| 113 | Supply Installation , testing and commissioning of LED type street light fitting suitable for 120 watt capacity LED lamp ,IP 66 pressure die cast housing with epoxy powder coated aluminium housing drak graphite gray colour finish Enclosure complete with control driver ,fixed on street light pole connecting with 1.5 sqmm 3 core copper cable from street light connector to junction box with suitable size lugs/thimble complete all as specified and directed by Engineer-in-Charge. |
| 114 | Bitumen Road |
| 115 | Providing and applying 2mm thick road marking strips (retro reflective) n exc 10cm wide of specified shade / colour using hot thermoplastic material by fully / semi automated thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experinces operator on road surface including cost of material etc complete as per direction of Engr-in-charge and accordance with applicable specifications |
| 116 | S&F Solar road stud 135x105x26mm mode of aluminium frame with mix epoxy filler of approved colour having bearing strength of min 20 tons complete all as specified and directed |
| 117 | S&F Caution / Mandatory sign board (as specified by Engr in charge) made of high intensity grade retro-reflective sheeting. It is made of Alcobond sheet / Aluminium sheet 2 mm thick confirming to IS : 736 covered with high intensity grade retro reflective sheeting as per IRC standard and logos in black to be painted and fixed after etching treatment fixed with suitable adhisive. It is painted with spoxy to standard made fixed to structural steel frame of MS angle 25x25x5mm with nuts bolts or recients ensuring safety. This is fixed to one vertical post of 50x50x5mm andle or 50x50mm square pipe as required of 3m lengh. This is painted in black and white alternative band of 25cm ht. One msg / definition plate of size 900x200mm is fixed below. Similarly round shaped boards 900mm dia are provided Make dark eye. complete all as specified and directed |
| 118 | Rain Water Harvesting |
| 119 | Providing all material & constructing brick masonary recharge pit of 4.0m dia x 4.0 m depth (Eff. depth) with brick work in cement mortar 1:4 ( 1 cement : 4 coarse sand) with 100mm dia weep holes at side walls @ 500 mm vertically & horizontally center to center, 200 mm thick RCC top slab in cement concrete (1:2:4 ) along with periferial & two nos. of intermediate RCC beams of size 250 x 450mm R/ F of slab 12 mm tor steel at bottom and 10 mm at topwith a spacing of 125 mm c/c, 4 nos 16 mm tor steel bars at bottom & 2 nos. 12 mm tor steel bars at top for beams with 8 mm stirrups @ 150 mm c/c, 2 nos. heavy duty SFRC cover of 560 mm dia,poly propelene coated rungs @ 300 mm c/c embeded in CC ( 1 : 2 : 4 ) blocks of 200 x 200 x 200 mm, 150 mm thick PCC in 1: 4 : 8 below footing with 150 mm projection, internal & external plaster in CM 1 : 4, necessary excavation, backfilling & disposal of surplus earth upto a lead of 50m complete in all respect including drilling percolation Bore Hole of 300/250 mm dia upto 50 meter depth with reverse rotary method in all types of soil including costs for mobilisation of Rig, including development of bore with 300-400 cfm compressor and making good the area after completion of work. Contractor shall arrange for all necessary tools,consumables and water required for drilling and providing and fixing 160 mm OD UPVC perforated/partially plain pipe (6 Kg/cm.sq.) in bore hole with cap at top of approved brand.( Item including of providing and laying silt free coarse sand , pea gravels, loose boelders etc., in layers as per direction of engineer-in- charge / detailed drawing of rain water harvesting pit) |
| 120 | Providing and constructing brick masonry desilting chamber of size 200x150xupto300 cms effective depth inside with 75 class designation brick work 345mm/230mm thick in cement mortar 1:4 (1cement:4 coarse sand) with weep holes all around , SFRC cover heavy duty 560mm dia and 150 mm thick R.C.C. top slab 1:2:4 mix(1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including necessary excavation, back filling, disposal of surplus earth as directed, foundation concrete 1:5:10 mix (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) below masonry walls with 150mm projection at either side including necessary baffle wall inside(as per std. drawing) , excavation,back filling and disposal of surplus earth upto a lead of 200 mtr., poly propelene coated rungs @ 300 mm c/c. |
| 121 | Solar Power Plant Please Enable Macros to View BoQ information |
| 122 | Solar Power Plant Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail