| Sl. No. | Item Description |
| 1 | Dismantling asbestos cement (plain, corrugated, semi corrugated etc.) sheets in roof coverings complete all as directed. |
| 2 | S&F for 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws with two corrugation side lap complete all as specified and as directed. |
| 3 | S&F for 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 4 | Dismantling of wall/ceiling board of any description and any thickness including cover fillets etc complete all as directed. |
| 5 | M&L position suspended false ceiling system using T-grid suspended ceiling grid system. The size of grid shall be 600x600mm, with GI frame work main runner 38 x 24 x 3600mm, cross 'T' 25 x 24 x 60mm/25 x 24 x 1200mm and wall angle 24 x 24 x 2540mm (thickness of the material of 0.30mm ), using 8-9mm thick ceiling panel laminated with PVC film on front face and foil back available in due drop texture as per IS-2095, part-I-1996, fixed in the grid of T-grid suspended ceiling grid system duly suspended by 4mm dia GI bar hanger from the purlins of the roof with butterfly clips all as specifed and directed by Engineer- in -charge. Make:-Gyproc/Armstrong. |
| 6 | Taking down chowkats or frames not exc.1.5 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and directed |
| 7 | -Ditto- all as per Item No.6 above but exc. 1.5 sq. m but n exc 4 sqm each complete all as specified and directed |
| 8 | Taking down shutters of any description exc 1.0 sqm but n.exc 2.0 sqm each complete all as specified and directed |
| 9 | Taking down shutters of any description exc 1.0 sqm but n.exc 2.0 sqm each and refixing in same opening complete all as specified and directed |
| 10 | S&F in repair for aluminium powder coated three track sliding window with two glazed shutters with 4mm thick float glass ordinary quantity and one shutter of stainless steel wire mesh 0.36 mm dia wire and 1.40mm aperture including good quality of bearing handle, locks, PVC rubber lining etc complete all as specified and as directed. Cat louge numbers of Jindal company or equivalent make complete all as specified and directed. Sections of Jindal company : Three track bottom – 20957, Three track top/vertical – 20958, Handle – 20606, Interlocking – 20605, Top and bottom – 20604. |
| 11 | M&L for factory made 100% solid wood plastic composite (WPC) door frame single rebated 90mm x 45mm made from wood plastic composite (Single extruded process) material with density 780kg/ cum all as directed. Note:-During fixing of chowkat, surface shall be make good in plumb with existing finishes like cement plaster wall tiles, floor tiles etc and as per ans site requirement fixed with screws not less than 50mm on existing chowkats or timber framed work complete all as specified and directed |
| 12 | S&F for 35mm thick flush shutters solid core construction, with block board core and plywood face panels, commercial type on both sides incl 2nd class HW plain cover fillets 35 x 6mm all around the shutters including two coat of synthetic enamal paint over one coat of pink primer complete all as specified and directed. |
| 13 | S&F in repairs Stainless steel butt hinges medium weight 100mm all as specified and directed. NOTE :- All screws shall be self tapping chrome plated and length of screw not less 38 mm |
| 14 | S&F Stainless steel sliding door bolts, bright bolt not lesss than 12mm dia with and incl a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate 250 mm long( selected quality as approved ) all as specified. |
| 15 | S&F Stainless steel Tower Bolt of 200 mm long ( selected quality as approved ) fixed with Self Tapping screws all as specifed and directed by Engr-in-Charge |
| 16 | S&F 150 mm long aluminum handles, cast type anodised and fixed with door complete all as specifed and directed. |
| 17 | S&F in repair floor door stopper of stainless steel type polished and tongue 135 mm anodised with hard drawn steel spring fixed in floor complete all as directed and specified. |
| 18 | M&L Granite (of any type), 18- 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platform,WHB plateform and like in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust with admixer of pigment to match with marble shade and,complete. all as specified. |
| 19 | Labour only for full round moulding to 18 to 20mm thick granite slab complete all as directed. |
| 20 | S&F for rolled mild steel frame work as in grills, doors or gates of angle or other sectioin with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and incl either hooks and hinges or steel hanging door fittings also fastenings and fixing etc. conforming Fe 290-W(Gde-E-165) quality -B complete all as specified and as directed. |
| 21 | M&L for preparation of new steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint over a coat of red oxide. |
| 22 | Taking down in cement plastering on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc upto any height of Bldg, including necessary scaffolding complete all as directed. |
| 23 | M&L for rendering 15mm thick in CM (1:4) on fair faces of brick or concrete surface finished even and smooth without using extra cement, mixed with WPC compound @ 2% (which is paid seperately), upto any height of Bldg, including necessary scaffolding , complete all as specified and directed. |
| 24 | M&L for providing Integral waterproofing compound for pcc in sunken treatment and external plaster, complete all as specified and directed. |
| 25 | M&L for rendering 15 mm thick cement plaster on faces of brick or concrete surfaces in cement mortar(1:6) finished even and fair without using extra cement , upto any height of Bldg, including necessary scaffolding , complete all as specified and directed. |
| 26 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, upto any height of Bldg, including necessary scaffolding complete all as directed. |
| 27 | M&L for providing 1.5 mm thick wall care putty on new plastered surfaces of wall , complete all as specified and directed. |
| 28 | M&L for preparation of new plastered wall surface of any description, width or girth, and applying two coats of OBD over a coat of primer upto any height of Bldg, including necessary scaffolding complete all as directed. |
| 29 | M&L for complete removal of existing treatment on walls, preparation of surfaces and make surface free from loose particles, oil stains etc and surface ideally prewetted and applying white cementitious wall care putty average thickness 1.5mm complete all as specified and directed by Engr-in-charge. |
| 30 | M&L for preparation of old plastered or unplastered surfaces of wall incl cornices, pillasters by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of OBD over a coat of alkali resistant priming surfaces, complete all as specified and directed. |
| 31 | M&L for preparation of old wall surface of any description, width or girth, application of resin pigment and hardener to desired colour spfd pattern and applying applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces. in any height of Bldg complete all as specified and directed by Engr-in-Charge |
| 32 | M&L for preparation of old steel surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enemel paint complete all as specified and directed by Engr-in-Charge |
| 33 | M&L for preparation of old wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enemel paint complete all as specified and directed by Engr-in-Charge |
| 34 | Demolition of stone slabs and tiles laid dry or laid dry and pointed of any description or thickness in floors, aprons etc., complete all as specified and directed by Engr-in-Charge |
| 35 | M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 36 | M&L for mirror polishing on marble / granite / kota stone / stone work where ever required to give high gloss finishe complete all as specified and directed |
| 37 | M&L glazed ceramic coloured tiles of size 450x300x7mm/450x350x7mm thick, on vertical surfaces of walls such as skirting dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4 and complete all as specified and directed |
| 38 | Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 39 | M&L for Cement concrete 1:3:6 type C-2 (using 40mm graded agg) as in plinth protection, 75 mm thick and finished even and smooth without using extra cement, including demolition of existing cement concrete all as specified and directed |
| 40 | M&L for 75mm thick PCC (1:3:6) type C2 (using 40 mm graded stone aggregate ) as in sub base and as in plinth protection laid in alterrnate panels and finish even and fair. |
| 41 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 42 | S&F for rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming Fe 410-W(Gde-E-250) quality -B complete all as specified and as directed. |
| 43 | Surface excavation not exc 30cm deep and averaging 15 cm deep and getting out in sodt loose soil. |
| 44 | M&L for PCC 1:4:8 type E-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete. |
| 45 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter |
| 46 | M&L for flat formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete. |
| 47 | S&F for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming |
| 48 | S&F 10mm dia round bars Gde IS 432 (part-I) and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming |
| 49 | S&F of but 6 mm dia and over upto and including 8mm dia in stirrups, spacers and binders |
| 50 | M&L RCC type B-1, 1:2:4 using 20 mm graded stone aggregate as in Chajjas all as specified . |
| 51 | M&L for RCC design mix M-30 (20mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like |
| 52 | M&L for RCC Type B1 1:2:4 (12.5mm graded aggregate Foundations, including rafts,footings, foundation beams;plinth beams; bases forcolumns, etc.; basement slabs,under-reamed piles and mass concrete |
| 53 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles. |
| 54 | M &L for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar !:6 Type C1 1:3:6 using (20mmaggregate complete |
| 55 | M&L for Brick work with fly ash bricks, straight or curved on plan exc 6 meter mean radius built in cement mortar 1:6 as in manholes complete all as specified and directed. |
| 56 | M&L for DPC in horizontal or vertical surfaces 40mm thick in cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate. Note : WPC will be measured and paid separately. |
| 57 | M&L for screed bed with WPC or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:4 Note : WPC shall be measured and paid separately |
| 58 | Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner |
| 59 | Supply and application of single component, seamless, spray applied, hybrid elastomeric PU based material i.e Nitoproof 725 of Fosroc chemicals (or) sikalastic 590 of Sika India Pvt Ltd (or) equivalent in any approved make as approved by GE over a coat of primer i.e Nitoproof WB primer of Fosroc chemicals (or) diluted sikalastic 590 of Sika India Pvt Ltd (or) equivalent in any approved make as approved by GE, all as recommended by manufacturer ans as specified.Note:-(i) Average minimum DFTof PU based material shall be 1mm and shall be applied by using a Graco pump.(ii) PU based material shall process the following properties solids by volume -65%, tensile strength ASTM D412-1.75Mpa, density 1.3 g/ml, elongation ASTM D-412-350%, Adhesion to substrate concrete-1.9Mpa, resistance to water-10m pressure.(iii) Rate are deemed to be include for cleaning and preparation of surface to receive PU water proofing system including filling of cracks with cementitious repair mortars i.e renderoc CS of Fosrock chemicals (or) equivalent of approved make.(iii) Work shall be got carried out by authorised applicator of the manufacturer and it shall be got approved by the GE before progressing the work.(iv) 10 years of guarantee shall be provided and security amount shall be deposited as speicified in tender documents. |
| 60 | M&L for providing reinforcement cement concrete as in lintel upto 1.5 Mtr clear span 1:2: 4 type B-1 using 20mm graded stone aggregate, set in CM 1:4 all as specified & directed. |
| 61 | Spreading & levelling in layers n exc 25 cm thick & well ramming including watering as required. |
| 62 | M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 Iitres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete |
| 63 | M&L for providing and injecting Along the external wall below concrete or masomy apron using chemical emulsion @ 2.25 litres per linear meter including drilling and plugging holes etc. in apron etc complete. |
| 64 | M&L for Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12 mmdia )holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors and all specified. |
| 65 | M&L hardcore of gauge not exc 63 mm deposited spread and leveled in layers not exc 15 cm thick watered and rammed to a true surface . |
| 66 | M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone agg as in sub base flooring all as specified (75 mm thick) |
| 67 | M&L25 mm thick cement concrete type B-1, !:2:4 (20mm graded agg) as in floors com,plete all as specified. |
| 68 | M&L for Rendering in CM 1 :4, 10 mm thick on fair faces of brick or concrete surfaces of wall finished even and smooth without using extra cement . |
| 69 | M& L for Factory made single extruded WPC (Wood S&F Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp- ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 70 | S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicityindex of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face)& 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 71 | S&F aluminium anodised powder coated ventilator using rectangular tube of size 63.50 x 25 x 1.50 mm including 3.50 mm thick designer glass louvers and stainless steel wire mesh 0.36 mm nominal dia of wire, average width of aperture 1.40 mm using ‘Jindal” aluminium section with provision for exhaust fan complete all as specified and directed by Engineer-in-Charge. |
| 72 | M&L for 2.8 mm thick sheet glass ordinary quality and glazing with of putty in sqare not exc. 0.5Sqm in each pane. |
| 73 | S & F in repair brass Chromium plated soap dish(Polycarbide) , fixed to wall with CP brass screws, all as specified and directed. equivalent make as per Appx 'A' as approved by GE |
| 74 | Aluminium anodised barrel tower bolts of extruded section, 200-mm long complete. |
| 75 | Butt hinges, extruded aluminium alloy with galvanized mild steel hinge pin, anodized, type C-21, 100 mm size complete. |
| 76 | Aluminium handles, cast type anodised, 125mm size complete. |
| 77 | M&L, Rotational moulded polyethyene water storage tanks 500 lit capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified,includinf supply and fixing of Ball brass valves, high pressure, with polythene float (25mm dia) and flynut complete, screwed for iron pipe or brass ferrule and fixed |
| 78 | S/F bib tap 15 mm bore dia chromium plated fancy type , screwed down for iron pipe |
| 79 | S&F stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed with both ends for iron pipe 20mm bore |
| 80 | S&F PVC connection 15mm size 450mm long with brass union at each end. |
| 81 | S & F in repair vitreous china wash basin, white flat back size 550x400mm excluding chain and plug and porcelain stopper but including brackets all as specified & directed including 32mm bore CP based fittings and PVC waste pipe suitable for 32fmm bore complete. |
| 82 | S&F 32mm brass CP waste coupling to WHB |
| 83 | M&L UPVC pipe of pressure 10 kgf/cm 2 suitable for water supply distribution incl all fittings,20 mm dia |
| 84 | M&L UPVC pipe of pressure 10 kgf/cm 2 suitable for water supply distribution incl all fittings, 15 mm dia |
| 85 | S&F 15mm dia pillar taps, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without lettered hot or cold with long and screwed shanks and flynuts, screwed for iron pipe and fixed. |
| 86 | S&F vitreous china squattting pan of Orrisa pan of pattern long pan size 580mmx450mm white with 'P' or 'S' trap front or back inlet and foot rest any pattern including connection to trap and to flushing pipe etc complete including lime concrete bedding and making good to floor. |
| 87 | S&F 10 ltrs capacity PVC valve less, symphonic action type flushing cistern, low level with inlet; ball valve, float and handle incl brackets |
| 88 | M & L for Non-skid coloured ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.06 Sqm but exceeding 0.11 Sqm , n floors etc. set set in neat cement slurry and joint filling of tiles by using epoxy to match the surface all as specified and as directed by Engr-in-charge.. |
| 89 | M&L for rendering 15 mm thck in CM 1:4 with even and fair finish as backing coat for tiles. |
| 90 | M & L exterior wall (Designer) tiles in vertical surface any size as approved set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, all as specified and as directed by Engr-in-charge.. |
| 91 | S&F PVC cowl suitable for 110mm PVC pipe |
| 92 | S&F in repair, PVC (SWR) junction single (single T), equal or unequal, 110mm bore, complete. |
| 93 | S&F PVC clamp suitable for holding 110mm PVC pipe |
| 94 | S&F PVC (SWR) pipe 110mm bore single socketed in any length with rubber ring jounts laid in trenches or in floor. |
| 95 | S&F PVC (SWR) floor trap 63mm dia of outlet plain with grating including jointing with solvent cement |
| 96 | S&F PVC (SWR) pipe 63mm bore single socketed in any length with rubber rings joints laid in trenches or in floor |
| 97 | S&F PVC(SWR) bend any radius of size 63mm bore. |
| 98 | S&F bend PVC (SWR) any radius 110mm bore |
| 99 | M&L for 3 coat of white wash on wall including preparation of surfaces |
| 100 | M&L for cutting into existing manholes for connecting new drains, 150mm bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required complete. |
| 101 | Material and labour for preparation of new decorated external wall surfaces and applying two coat of cement paint complete all as specified and as directed. |
| 102 | M & L for Machine Pressed Precast rubbermoulded concrete interlocking Paver Block any shape, size,colour or design, confirming to 15658-2006 of 60mm thickness, M-30 Grade including M -sand filling under paver block including watering,consolidation nd leveling in layers n exc 25cm thick and all as specified and directed . |
| 103 | M&L for chequered cement concrete tiles 25cmx25cmx25mm thick , with grey cement and pigment set jointed and pointed in neat cement slurry in floors including 20 mm thick screed bed or beding layer in cement mortar 1:6 complete all as specified |
| 104 | Supply and fix 600 x 450mm bevelled edge mirror 5.5mm thick of selected quality glass, mounted on PVC framework including sheet back side and fixed to wooden plugs with chromium plated brass screws and cup whashers all as specified and as directed. |
| 105 | S & F in repairs tubler towel rail 20mm dia 60cm long of brass chromium plated ;D: type fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 190 gms). |
| 106 | Supply only approved water proofing liquid of make DR FIXIT/FOSROC/PIDILITE |
| 107 | M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in bed for manhole complete all as specified and directed. |
| 108 | M/L for 150mm dia salt glazed stone ware drain pipes ISI Marked laid in trenches and jointed all as specified and as directed. MAKE : TSL/TACEL |
| 109 | S&F PVC SWR pipes, 160 mm bore, single socketed in any length with rubber rings joints, laid in trenches complete all as specified and directed. |
| 110 | M&L for Plain cement concrete 1:4:8 type C2 (using 40 mm graded stone aggregate) for concrete bed to drain pipes (work in foul condition) including packing under and hunching against the sides of pipes after they are laid and tested for 150 mm dia pipes complete all as specified and directed. |
| 111 | M&L for PCC 1:3:6, type C1 (using 20 mm graded stone aggregate) for coping and benching inside the manholes including weathering, slightly rounded or chamfered angles and throating and including necessary formwork complete all as specified and directed. |
| 112 | M&L for Precast cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate) as in cover slab for manholes set in cement mortar 1:6 complete all as specified and directed. Note: Reinforcement will be measured and paid separately (use and waste of form work is deemed to be included). |
| 113 | M & L Rendering in CM 1:3, 5mm thick on fair faces of brick work or concrete surfaces on ceiling complete all as specified. |
| 114 | S&F TMT bar 10mm dia cut to length, bent to shape required and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 115 | M&L for extra form farming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds ,mitred stopped ends etc. |
| 116 | Supply and fix mild steel section ( Y shape) flat angle , round for hand rails , Tie bars , Post and struts in fencing including cutting tops to shape as directed notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 117 | Supply and fix Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed |
| 118 | Fixing only Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed |
| 119 | Supply and fix 610 mm dia CONSEC-ZAL Super Razor punched Barb Tape (SRBT) Aluminium base helix coil with and including necessary GI fixing clips for securing complete all as specified and as directed with following specifications :- (i) Dia of coil (unstretched) - 610 mm (ii) No. of circles - 51 turn per coil.(iii) Weight of each coil with hessain pack - 8.50 Kg ( + 0.50Kg ) (iv) Coverage per coil - 8 RM (v) Central core wire - Made from 2.60 mm dia GI - HTSS wire as per IS- 4454 galvanised as per IS -2629 .(vi) Razor punched strip Razer punched tape is CONSEC-ZAL steel comprising of aluminium base with zinc alloy @ 150 gm/Sqm conforming to ASTM A-792/A-792M with additional primer treated of Epoxy/Polyurethane and final paint top coat of Caulified green shade ( BSL -139 ) by Hot Dipping process .Note :- Running length of the wall shall be measured for the payment purpose. |
| 120 | Supply only chain link MS galvanisd fencing, any size or type complete all as specified and direced |
| 121 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire etc complete all as specified and directed |
| 122 | S & F of MS flat iron for securing ms sheet including all necessay welding or bolting or riveting etc and similar work conforming to Fe-290 gde E-165 |
| 123 | S&F of Framed work such as grills, gratings, framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etcetc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of conforming to Fe.290.Gde-E-165 |
| 124 | S&F Cast Iron for ornamental and intricate design and similar articles all as specified and directed. |
| 125 | Supply and fix for 2mm thick polycarbonate sheets outer sky light panels clear acrylic plastic sheet for Roof/ vew cutter any colour fixed to steel frame work with self tapping screws complete all as specified and as directed. |
| 126 | M & L for preparing new steel and iron surfaces any description n exc 10 cm in width or girth , priming with red oxide and applying one coats of synthetic enamel paint. |
| 127 | Excavation in post holes (or similar joles) not exc 0.5 Cum and getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing surplus soil to a distance not exc 50 mtr and making good surfaces etc complete all as specified and as directed by Engr-in-Charge.. |
| 128 | M & L for PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in foundation, filling and mass concrete etc complete and as directed by Engr-in-Charge. |
| 129 | S & F rolled mild steel work in tubular trusses including special shaped washers etc complete using ERW or induction butt welded tubes confirming to IS : 1161-1979Gde St-240 complete all as specified and as directed by Engr-in-Charge. |
| 130 | S & F rolled mild steel plates (plane or chequered ) channels, square cut or notched (ordinary and countersunk) forming holes without any attachement. Fe 410 W (Gde E-250) quality -B |
| 131 | M&L for Plain, galvanised, mild steel sheeting,0.50mm thick in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 ® |
| 132 | Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 m depth and getting out in Hard dense soil complete all as specified and directed. |
| 133 | S&F PVC SWR pipes, 160 mm bore, single socketed in any length with rubber rings joints, laid in trenches complete all as specified and directed. |
| 134 | M&L for PCC 1:3:6 type C2 (using 40mm graded agg) concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 150mm dia of bore pipe including demolition of existing old one with PCC complete all as directed. |
| 135 | M&L in repair for 200 mm bore RCC pipes, class NP2 laid and jointed with collars and tested including demolition of existing old one (salt glazed earthware, AC or reinforced pipes etc) set in cement mortar complete all as directed. |
| 136 | M&L for RCC (Nominal mix) Type B1 1:2:4(20mm graded crushed stone aggregate) slabs supported on walls,beams and columns in floors,roofs, landings balconies ,canopies, deck slabs and in shelves and the like complete all as specified and directed |
| 137 | S & F TMT bars as in reinforcement 6 mm dia to 8 mm dia cut to length bent to shape required including cranking, bending and binding with and including MS wire (annealed) not less then 0.9 mm dia. Complete all as specified and as directed. |
| 138 | M&L for Formwork rough finished surface to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. Complete all as specified and directed. |
| 139 | M&L for 10mm thick plastering in CM 1:4 on brick or concrete wall surfaces fair and even with 2% of WPC on cement complete all as directed.(Note:WPC shall be measurned and paid in separatetly) |
| 140 | M &L for providing cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in copings, benching, kneeler , apex stone, including weathering, slightly rounded or chamfered angles & throating as directed and including necessary form work required. Complete all as specified and as directed. |
| 141 | M&L for preparation of new plastered wall surface of any description, width or girth, and applying two coats of cement base paint over a coat of primer complete all as specified. |
| 142 | Material and labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty PVC concealed conduit including all accessories, Metal flush box of suitable module, with earth dolly, covered with twin colour (specified by Engr-in- Charge)modular white cover plate & frame after chasing in brick masonry walls etc for accomodating modular switches, sockets, regulators etc including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly, providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed for the following (Make- Finolex/ ANchor/ Grandlay/ Polycab/L&T) |
| 143 | One light / Ceiling / exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and as directed |
| 144 | One ceiling fan point controlled by one, one way switch 6 Amps and regulatorNote : PVC Casing caping / Pipe of size as required at site on surface of ceiling (only for fan point) in lieu of concealed is permitted and is deemed to be included in the unit rate quoated. |
| 145 | One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and as directed |
| 146 | One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and as directed |
| 147 | Description all as per 142 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point,16 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed |
| 148 | Supply and fixing Modular Switch - 6 Amps, Single pole one way, one module complete all as specified and as directed. (Make:Anchor/Roma/Havells/Legrand/Indoasian) |
| 149 | Supply and fixing Modular Switch - 16 Amps, Single pole one way, one module complete all as specified and as directed. (Make:Anchor/Roma/Havells/Legrand/Indoasian) |
| 150 | S & F Modular socket outlet multipurpose 6 Amps, 5 pin, 2 module, complete all as specified and as directed. (Make:Anchor/Roma/Havells/Legrand/Indoasian) |
| 151 | S & F Modular socket outlet multipurpose 16 Amps, 6 pin-shuttered type, 2 module, complete all as specified and as directed. (Make:Anchor/Roma/Havells/Legrand/Indoasian) |
| 152 | Supply and fixing modular fan step regulator, 120W - 2 module suitable for ( 48\\" & 56\\" fans) supply complete all as specified and as directed. |
| 153 | S & F Ceiling rose, 3 phase / PVC / polycarbonate, complete all as specified and as directed |
| 154 | Supply and fix in repair for wall mounted LED 18/20watts with lumens out put not less than 2000 lumens white/ warm white, box type (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4' x 20watts complete all as specified and as directed. Make: Bajaj Cat No. BCLAB 20W, JAQUAR Cat part No LGLZ01X020XN or equvalent of make Philips/ as approved. |
| 155 | S & F in repair for recess mounted 2' x 2' luminaire to enhance the delight of occupants with comfortable experience through its classic design & glare free sift illumination square LED panel 43 watts, white/Warm White powder coated CRCA housing with full window acrylic diffuser giving a complete full glow look, operating voltage 140 volts - 270 volts, AC, 50 Hz complete all as specified and as directed. Make- Bajaj Cat No BZRSQL 36L LED GX WH or its equivalent in Havells/ Jaquar/ Phillips or equivalent. |
| 156 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection completecomplete all as per Make JAQUAR, Bajaj, Philips, Havells as approved. |
| 157 | Taking down ceiling fan of any size, type and make after disconnecting the electrical connections and refixing back (after cleaning and servicing/ repairing / painting / rewinding) including Repairing of ceiling fan and replacing all the unserviceable parts such as bearing, gunmetal bushes, capacitors, bolt/nuts, split pins, rubber reels, mounting clamps etc. and connecting up with 3 core 1 sqmm copper flexible cable from ceiling rose to the fan all as directed. Note:- The cost of cleaning and servicing/ repairing / painting and 3 core 1 sqmm copper flexible cable from ceiling rose to the fan is included in this Item. |
| 158 | Supply and fix in repair for plastic body exhaust fan, AC single phase, 240 volts of size 250 mm sweep with louvers all as per Cat No. Maxma DX 10\\" of Make Bajaj or equivalent of Automberg/ Havells/Usha with necessary connection and replacement of flexible copper cable from ceiling rose complete all as specified and as directed. |
| 159 | S & F in repair for sheet metal enclosure MCB DB TPN 415 volts, IP 43 of 4 way made of CRCA sheet steel, powder coated provided with insulated phase busbars, neutral bar, shrouds, earth bars, cable ties, blanking plates and circuit identification labels with necessary electrical connection, double door with locking system including cement work for inserting the DBs for mounting in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.Make: L&T Cat Part No DBTPE004DD or in equavalent in Legrand, C & S,ABB, Schneider |
| 160 | S & F sheet metal enclosure MCB DB SPN 12 way with 100 Amps rated bus bar 240 Volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed |
| 161 | S & F for MCB TPN rated capacity 63 Amps, 415 Volts breaking capacity 10 KA complete all as specified and as directed. L&T/Legrand/C & S/Schneider/ABB/Indo Asian/Havells |
| 162 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 5 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning |
| 163 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning |
| 164 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 165 | Taking down old / sub main wiring of any size aluminium / copper conductor cable along with batten / PVC conduit and making good the disturbed surface of wall all as directed. |
| 166 | S & F submain wiring with 2 single core (FRLS) PVC insulated unsheathed multistranded flexible copper conductor cable, of 4.0 Sqmm and one single core 4.0 Sqmm flame retardent low smoke (FRLS) PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per IS 694/1990 drawn through including concealed in brick masonary PVC conduit and conduit accessories heavy duty ISI marked, providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed all as specified and as directed complete all as specified and as directed. Note :- ( Two runs of main copper wire, one run of earth wire cable & PVC conduit shall be measured together as one length). |
| 167 | All as per item No 162 but of size 1.5 Sqmm |
| 168 | Supply, lay, joint, test and commissioning of LT under ground cable 1100 volt grade , XLPE insulated and PVC sheathed heavy duty armoured with aluminium conductor , IS 7098-I Marked, Laid in trenches/ducts/fixed on poles/walls/laid under roads/paths/drains/culverts or encased in GI pipe including cable glands, lugs jointing material etc of 25 Sqmm 4 Core Size complete all as specified and directed |
| 169 | Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth, for foundation etc. or for shafts, welles cesspitsm, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5m in depthe in hard/dense soil and getting out , complete all as specified and as directed by Engr in Charge. |
| 170 | Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25m, complete all as specified and as direted by Engr in Charge. |
| 171 | Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the strating point, complete all as specified and directed by Engr in Charge. |
| 172 | Supply and laying 40 mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties plete with fittings for cable protection complete all as specified and as directed. |
| 173 | M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 174 | Supply and fix MCB DB SPN 8 way, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with integrated door earhting system, with tinned copper bus bar ,neutral link earth link complete all as directed. Make: Legrand or its equivalent make Indoasian/Havells/Legrand/Anchor |
| 175 | Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections and joints including Pipes, Bricks, etc of any description complete all as specified and as directed. |
| 176 | Supply, laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductors 1100 volts grade of size 4 core x 10 Sqmm laid in trenches, fixed on wall etc complete all as specified and directed. |
| 177 | M & L Cement Concrete 1:3:6 (20 mm graded aggregate) as in coping of pole etc including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified |
| 178 | Supply and fix black bolt with hexagon head and nuts round neck of any size as required at site complete all as specified and as directed |
| 179 | Taking down old unserviceable feeder pillar box of any type, Supply, fixing, testing and commissioning of LT feeder pillar panel double door floor mounted outdoor type, as per IP-65 grade, made out of CRCA sheet 3.00 mm thick of outer body and 2 mm of internal thickness of suitable size with aluminium bus bar 200 Amps, 4 strip (3 phase & Neutral) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, internal wiring with suitable size of copper wire, panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking, shouldhave danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) type B-1 foundation for fixing of panel complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands, Nuts & Bolts, Washers complete with comprising of following and including: - |
| 180 | Incoming |
| 181 | (a) MCCB, 4 Pole, 415 Volts, 100 Amp, adjustable type Thermal Magnetic relay with breaking capacity 36 KA at 415 volts Ics=100% Icu -01 No Make . ABB, Seimens, L & T, Schneider, BCH, Havells, Legrand, C&S Electric |
| 182 | (b) Digital Voltemeter 0-500 volts with selector switch - 01 No |
| 183 | (c) Suitable Digital Amp meter 0-600 Amp with selector switch - 01 No |
| 184 | (d) Indicator lamp LED type (R,Y,B) complete with bakalite fuse fitting - 01 Set |
| 185 | Outgoing |
| 186 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 5 To 32 AMP and current carrying capacity in the LT Stareet light panel complete with connection testing and commissioning- 5 Nos |
| 187 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 40 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning-6 Nos |
| 188 | S & F Modular socket outlet multipurpose 16 Amps, 6 pin-shuttered type, 2 module, complete all as specified and as directed.- 4 Nos |
| 189 | Automatic astronomical type timer switch with switches ON/OFF the street lights base on lux level of natural light current rating 100 Amps, 220 Volts, 50 Hz. The sensor based timer should also have over voltage and low voltage trip with auto reset facility the sensor alongwith suitable power contactor, MCB and support terminals should be enclosed-1 No |
| 190 | Supply and lay in trenches /under roads/ crossing or fixed to wall/ pole, GI tubing light grade of size 40mm bore for protection of UG cables complete all as specified and as directed.(Note : Road cutting and PCC of leveling same surface is deemed in this rate) |
| 191 | Supply and fixing weather proof street light junction box of size 150 x 150x 105 mm including MCB SP 6 Amps and connecting terminals 4 way and fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as specified and as directed. Make : Hensel/Sintex/Universal Switch Gear control Note : The rates quoted are inclusive of provision and fixing of suitable lugs and glands for cable connection. |
| 192 | S & F in repair decorative LED bollard 10 watts inverted prism type with aluminium die casting, with adequate size elecrical connections complete all as specified and as directed. |
| 193 | Supply and fix for energy saving new generation environmental friendly long life with peanut lenses versatile presure die cast housing and heat sink in aluminium extrusion IP 66 flood light fitting luminaire with secondary optics, high power LEDs as light source and electronic driver of capacity 120 watts with lumens out put not less than 12000 lumens with pre wired suitable for sports lights and provision of new 3 core multistranded copper conductor of size 23/0.193 for connection including taking down of old unserviceable fitting complete all as specified and as directed. Make: Bajaj cat no. GLATT MT144L WH PO PC SD PD, or equivalent like Philips, Havells, CG as approved . |
| 194 | Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail