| 1 | Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) complete all as specified and as directed. |
| 2 | Taking down Chowkats or frames exceeding 1.5 Sq. M but not exceeding 4 Sq. M each (Without taking off shutters from the frame) complete all as specified and as directed. |
| 3 | S&F Pressed steel frames for door with one or more rebates including necessary fixing lugs hinges, lock, strike plate etc.complete for frame of size (105x60mm) complete all as specified and as directed. |
| 4 | S&F Pressed steel frames for door with one or more rebates including necessary fixing lugs hinges, lock, strike plate etc.complete for frame of size (125x60mm) complete all as specified and as directed. |
| 5 | M&L for PCC (1:3:6) type C-0 in filling of pressed frame. complete all as specified and as directed. |
| 6 | S&F 150 mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor.complete all as specified and as directed. |
| 7 | S&F 35 mm thick Flush shutters, solid core construction, with solid block board core and plywood face panels, commercial type on both sides. complete all as specified and as directed. |
| 8 | S & F 35 mm thick factory made Second class hard wood kiln seasoned and chemically pressure treated Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc. complete all as specified and as directed. |
| 9 | S & F Solid pvc Door Frame of size (150mmx95 mm) made out of 5mm wood grain printed PVC Sheet reinforced with MS Square etc. complete all as specified and as directed. |
| 10 | Supplying and fixing in frame at site, factory made solid panel pvc moulded door shutter 28 to 30 mm thick (style) with 2,4,or 6 raised panel design with 2 mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face with particle board core, supplying & fixing in frame at site as per specification & drawing. complete all as specified and as directed. |
| 11 | S&F powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and as directed. (minimum thickness of powder coating 50 micron). |
| 12 | S&F for powder coated anodised window/ventilators shutters, side hung type without sash bars aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips,ruber neoprene packing,anodised aluminium snap beading screws,anodised aluminium fittings such as peg stays 150 mm long(1 no),hinges type-B-21 100 mm long( 2 no) suitable handle 1 no complete all as specified (thick ness of powder coating not less than 50 micron). complete all as specified and as directed. |
| 13 | S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or revited, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe.290. Gde-E-165 Including Taking down/Dismantlinig wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 14 | Taking down/Dismantlinig wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 15 | S & F 4 mm thick Sheet glass, ordinary quality and glazing with wooden beads in squares not exceeding 0.5 Sq. M in each pane complete all as specified and as directed. |
| 16 | S & F 4 mm thick Sheet glass, frosted on one side, ordinary quality and glazing with wooden beads in squares not exceeding 0.5 Sq. M in each pane complete all as specified and as directed. |
| 17 | S&F stainless steel wire cloth with 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed withstainless steel wire stapple complete all as specified and as directed. |
| 18 | M&L in repair 18/19 mm thick pre-laminated particle boards exterior grade prelaminated both sides with decoratative choice lamination fixed in timber frame work. complete all as specified and as directed. |
| 19 | S & F 100 mm long extruded aluminium alloy with galvanised mild steel Butt hinges and fixed type B-21 complete all as specified and as directed. |
| 20 | S & F 100 mm long extruded aluminium alloy with galvanised mild steel Butt hinges medium weight cold rolled mild steel and fixed type B-21 complete all as specified and as directed. |
| 21 | S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised.complete all as specified and as directed. |
| 22 | S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed. |
| 23 | S & F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and as directed. |
| 24 | Supply fix in repairs Harrison rails, mild steel, chromium plated fixed alongwith 2 Nos. of brackets, stops, rollers etc, complete all as specified and as directed. |
| 25 | S&F in repairs 10 Ltrs. Capacity PVC flushing cistern low level slimline or equivalen make / model with all accessories complete all as specified and as directed. |
| 26 | Supply & Fix in repairs Vitreous EWC size (580x440 mm) white with including P or S traps (excluding flushing cistern and flush pipe) complete all as specified and as directed. |
| 27 | S & F in repairs Vitreous China Ware Wash hand basin white, flat back, size (550 x 400 mm) size including cutting for and pinning ends of brackets or erecting stand and waste pipe as requred complete all as specified an as directed |
| 28 | PVC connection 15 mm bore 600 mm long complete all as specified and as directed. |
| 29 | S&F in repairs brass cromium plated Tubular Towel Rail 20 mm dia, D Type, 60 cm long between flanges. (Minimum weight 190gms) complete all as specified and as directed. |
| 30 | Supply and fix (600mm x 450 mm) bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers incl taking down old one. complete all as specified and as directed. |
| 31 | S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar of dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size (915mmx460mm) bowl size (410mmx330mmx160mm). complete all as specified and as directed. |
| 32 | S&F in repair kitchen plate rack made of stainless steel sheet not less than 0.63 mm thick of over all size (1050 x 750 x 250 mm) complete all as specified and as directed. |
| 33 | Dismantling floor, hearth or wall tiling incuilding cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises.complete all as specified and as directed. |
| 34 | Glazed ceramic coloured tiles in vertical surfaces (450x 350x 7 mm) thick set and jointed in neat cement slurry & painted in white or colour cement to match incl plastering 10 mm thick in CM (1:4) complete all as specified and as directed. |
| 35 | M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including Screed bed or bedding layer of cement mortar (1:6), 15 mm thick for laying floor finishes. complete all as specified and as directed. |
| 36 | M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including Screed bed or bedding layer of cement mortar (1:6), 15 mm thick for laying floor finishes. complete all as specified and as directed. |
| 37 | Demolition of stone slabs tiles of any description or thickness in floors aprons laid bedded and pointed in any morter etc complete all as specified and as directed. |
| 38 | M & L for granite of any type 18-20 mm thick machine cut bedded and jointed with grey cement slurry and pointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete incl 20 mm thick screed bed (1:6) CM in floors. complete all as specified and as directed. |
| 39 | Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) complete all as specified and as directed. |
| 40 | M&L for 75 mm thick cement concrete as in plinth protection/ path etc type C-2 (1:3:6) (using 40mm graded aggregate) finishing concrete surface even and smooth with using extra cement complete all as specified and as directed. |
| 41 | M&L for 100 mm thick cement concrete type C-2 (1:3:6) using 20 mm graded stone aggregate as in path/hardstanding/sub base complete all as specified and as directed. |
| 42 | M & L for Polythene film, black, 150 micron laid in floor ,complete all as specified and as directed. |
| 43 | M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment complete all as specified and as directed. |
| 44 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:3) and even and smooth without using extra cement including mixing of water proofing compound wherever required for floors and sides of wall in sunken floors complete all as specified and as directed.NOTE: Water proofing compound will be measured separately |
| 45 | M&L applying one coat of NITTO proof to sides and bottom of floors to sunken floors. complete all as specified and as directed. |
| 46 | M & L for plain cement concrete Type E2 (1:5:10) (using 40mm graded stone aggregate) in foundations, filling and mass concrete. complete all as specified and as directed. |
| 47 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets. complete all as specified and as directed. |
| 48 | S&F for Anodised aluminium/ GI snap grid power coated framed work of size (605x605 mm) for false ceiling all as specified with hangers 4mm thick GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and as directed. |
| 49 | M & L for 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to GI/Aluminium framework with screws fixed in ceiling flat or sloping complete all as specified and as directed. |
| 50 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed. |
| 51 | Demolition of brick work or stone/ boulder masonry built in cement mortar or cement lime mortar including removal to rubbish complete all as specified and as directed. |
| 52 | M&L for half brick work burnt modular bricks built in cement mortar (1:4) straight or curved on plan exceeding 6mtr mean radius complete all as specified and as directed. |
| 53 | M&L for 15mm thick plaster in two layers on fair faces of brick work or concrete surface in cm (1:4) with wpc @2% by weight of cement face of conc work to wall surface and the surface is finished even and smooth without using extra cement.WPC paid separetely complete all as specified and as directed. |
| 54 | M&L rendering 15mm thick on other than fair faces of brick or concrete Surfaces in cement mortar (1:6) finished even and smooth without using extra cement. complete all as specified and as directed. |
| 55 | M&L rendering 5mm thick of cement plaster (1:3) on concrete surfaces of ceiling finished even and smooth(without using extra cement.). complete all as specified and as directed. |
| 56 | Supply only Integral water proofing compound complete all as specified and as directed. |
| 57 | Dismantling plain or corrugated asbestos sheeting any thickness in roof covering.complete all as specified and as directed. |
| 58 | S&F pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed. |
| 59 | Removing complete existing treatment incl pcc pedding of roof surfaces by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed. |
| 60 | M&L for brushing neat cement slurry with 03 Kg of cement per Sqm complete all as specified and as directed. |
| 61 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) . (Internal water proof compound measured seperately) complete all as specified and as directed. |
| 62 | M&L 25 mm thick cement concrete PCC Type B0 (1:2:4) using 12.5 mm graded aggregate. complete all as specified and as directed. |
| 63 | M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application including coating the surface with water based bituminous primer blow bitumen of 85/25 or 90/15 at 1.2 Kg/Sqm both at bottom and top of the membrance and finally finished with one coat of bitumenous aluminium primer at 100 gm per sqm complete all as specified |
| 64 | Taking down rain water pipes inculding all fittings any size and pattern complete all as specified and as directed. |
| 65 | S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls. complete all as specified and as directed. |
| 66 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes double socketed in any length with rubber ring joints fixed in walls. complete all as specified and as directed. |
| 67 | S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 68 | S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 69 | S & F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door complete all as specified and as directed. |
| 70 | S & F 110 mm bore PVC (SWR) Vent Cowl complete all as specified and as directed. |
| 71 | S&F 50 mm bore sand cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and as directed. |
| 72 | S&F 50 mm bore bends any radius sith ducks of heel rest complete all as specified and as directed. |
| 73 | M&L 75 mm bore for cast iron floor trap with grating incl jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed. |
| 74 | M&L 75 mm bore for cast iron Nahani trap with grating incl jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed. |
| 75 | Supply & fix 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed. complete all as specified and as directed. |
| 76 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all as specified and as directed. |
| 77 | Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all as specified and as directed. |
| 78 | Taking up or down 25 or 32 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all as specified and as directed. |
| 79 | Supply and laying 20 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed. |
| 80 | Supply and laying 25 mm dia CPVC pipes SDR 11 & plain/brass CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed. |
| 81 | Supply and laying 32 mm dia CPVC pipes SDR 11 & plain/brass CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed. |
| 82 | S & F in repairs 15mm bore angular/ concealed stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions. complete all as specified and as directed. |
| 83 | S & F in repairs 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.complete all as specified and as directed. |
| 84 | S & F in repairs 15 mm bore chromium plated two way bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule. complete all as specified and as directed. |
| 85 | S & F in repairs 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed. complete all as specified and as directed. |
| 86 | S & F in repairs Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. |
| 87 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161 1979 grade St.-240 complete all as specified and as directed. |
| 88 | Preparation of new or previously treated steel surfaces of any description, over 10 cm width or girth, not otherwise described appling one coat of Red Oxide, zinc chorme and applying two coat of synthetic enamel paint. complete all as specified and as directed. |
| 89 | Preparation of old painted treated steel surfaces of any description, over 10 cm width or girth, not otherwise described appling one coat of synthetic enamel paint.complete all as specified and as directed. |
| 90 | Preparation of new or previously treated wood surfaces of any description, over 10 cm width or girth, not otherwise described appling one coat of pink primer over applying two coat of synthetic enamel paint. complete all as specified and as directed. |
| 91 | Material & Labour for preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm over new surface over 1 mm thick wall care putty. complete all as specified and as directed. |
| 92 | M & L for Complete removal of old surface for preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm over new surface over 1 mm thick wall care putty. complete all as specified and as directed. |
| 93 | M&L for preparation of new plastered surfaces of walls and applying two coats of acrylic distemper including one coat of chalk whiting on plastered surface to prepara-tory to distempering complete all as specified and directed over 1 mm thick wall care putty. complete all as specified and as directed. |
| 94 | M&L for complete removal of old surfaces of walls and applying two coats of acrylic distemper over one coat of 1mm thick putty surface including preparation of surface complete all as specified and as directed. |
| 95 | Preparing new surfaces of ceilings by brooming down or by steel wire brushing and applying three coats of white wash.complete all as specified and as directed. |
| 96 | M&L for preparation of old decorated plastered surfaces of ceiling and applying one coat of white wash complete all as specified and as directed. |
| 97 | Dismantling PVC/RCC water tank and removing to store exc 500 & not exc 1000 ltrs complete all as specified and as directed. |
| 98 | S&F 500 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed Including dismantling PVC/RCC water tanks and removing to store n exc 500 complete all as specified and as directed. |
| 99 | S&F for health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connection and fixed in position complete all as specified and as directed.. |
| 100 | M& L for machine cut kota stone slab flooring 20-25mm thick over 20mm thick screed bed in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 101 | M& L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 15mm thick cement screed in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 102 | Taking down carefully existing unserviceable copper/ aluminium point wiring (light,fan , call bell, two way, socket or power point etc) complete with fittings/fixures such as switches sockets, ceiling rose, fan regulators, bell push,call bell,bracket light fittings and making good to the disturbed surface complete all as directed by Engr-in-Charge. complete all as specified and as directed. |
| 103 | Taking down the existing unservicable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified by Engr-in- Charge. complete all as specified and as directed |
| 104 | Taking down carefully unsv aluminium submain wiring of any type /location including conduit /casing and earth wire and making good the distributed surface of walls /ceiling matching with existing finishes all as directed by Engr-in-Charge. complete all as specified and as directed |
| 105 | Taking out unsv UG Cable any cross sectional area and connection of any description of any description laying in trenches or fixing with wall or poles complete all as specified and as directed Please Enable Macros to View BoQ information |
| 106 | Taking out unsv UG Cable any cross sectional area and connection of any description of any description laying in trenches or fixing with wall or poles complete all as specified and as directed Please Enable Macros to View BoQ information |