| 1 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge. (SOR No. 15.3) |
| 2 | Chipping, Removing, Carefully loose plaster and Concrete work by low impact Hammer, Breaker without damaging the structure as Instructed by Engineer-in-Charge. (SOR 14.64) |
| 3 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : M-20 Grade Concrete SOR No. 5.1.1 |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level. SOR No. 5.9.1 |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform. SOR No. 5.9.3 |
| 6 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786 . SOR No. 15.16.6 |
| 7 | Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. Cement Mortar 1:6 (1 cement: 6 sand). SOR 6.5.2 |
| 8 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement : 6 sand) SOR 13.2.2 |
| 9 | Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm SOR No. 12.32.2 |
| 10 | Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5o (Eighty Seven Point Five Degree) 110 mm bend . SOR NO. 12.33.5.2 |
| 11 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings etc. (SOR 18.28) |
| 12 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 25 mm nominal outer dia pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittingsi/c fixing the pipe with clamps at 1.00 m spacing complete SOR NO. 18.6.2.3 |
| 13 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 15 mm nominal outer dia pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittingsi/c fixing the pipe with clamps at 1.00 m spacing complete. SOR 18.6.2.1 |
| 14 | Providing and fixing CPVC gate valve with knob of approved quality...25 mm nominal bore SOR 18.13.1 |
| 15 | Point wiring for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification . SOR No. 10.1.1.1 |
| 16 | Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc. complete: 300x16 mm.. SOR No.9.65.1 |
| 17 | Providing and fixing ISI marked stainless steel door latches with screws etc. complete : 300x20x6 mm SOR 9.68.1 |
| 18 | Providing and fixing ISI marked stainless steel tower bolt black finish, with necessary screws etc. complete : 250x10 mm SOR No. 9.66.1 |
| 19 | Providing and fixing Stainless steel hanging type floor door stopper with necessary screws, etc. complete. SOR NO. 9.76 |
| 20 | Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete : 125 mm SOR 9.69.1 |
| 21 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,etc SOR 21.1.2.2 |
| 22 | Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work ) SOR NO 13.46 |
| 23 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete.Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of APD/Chief Engineer will be required. SOR NO 13.41 |
| 24 | 20 mm cement plaster of mix : 1:4 (1 cement : 4 sand) SOR NO 13.3.1 |
| 25 | Finishing walls by any mechanical or manual means with Premium Acrylic Smooth exterior paint (Premium exterior) of required shade including all scaffolding. New work . SOR NO 13.53 |
| 26 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Single pole MCB SP 0.5Amp to 5Amp 10kA rating SOR NO 27.8.1.1 |
| 27 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'D' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- For Triple pole MCB TP 6Amp to 32Amp 10kA rating SOR NO 27.9.3.2 |
| 28 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 sand) SOR NO 13.8 |
| 29 | \\"Water proofing treatment over Roof, Wall, Chajjas. Balcony with fibre glass mesh and Sealer coat at leakage/ seepage area consisting of.(i) Surface preparation roughening of surface, opening cracks in 'V' groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely. SOR No. 22.22 |
| 30 | Providing & applying crack fill paste for crack filling up to 5 mm cracks.Widen the crack by putty knife in V/U shape & apply 1st priming coat of crack fill paste diluted with water in 1:1 proportion over the crack by brush. Apply 2nd coat with filling of crack fill paste when the surface is tacky but not dried completely with putty knife & spatula.After 4 hours of application 2nd coat apply 3rd coat of Crack fill paste. The work shall be carried out as recommended by the manufacturer's specification & the direction of the Engineer-in-Charge SOR NO 22.3 |
| 31 | Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) : Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/RCC work. SOR NO 14.83.2 |
| 32 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument and/ or the75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2) : 50 mm average thickness in 3 layers. SOR NO 14.80.3 |
| 33 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete SOR NO 14.27 |
| 34 | Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.):Epoxy injection grout in concrete/RCC work of approved make SOR NO 14.83.3 |
| 35 | \\"Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design :. Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :..With well burnt bricks\\" SOR NO 19.9.1.1 |
| 36 | Providing and laying Ceramic glazed floor tiles 300x300 mm or more (having thickness 6 to 7mm) of 1st quality conforming to IS : 15622 of approved make in any colours and shade laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete. SOR NO 11.48 |
| 37 | Providing and fixing Ceramic glazed wall tiles 300x450 mm or more (having thickness 6 to 7 mm) of 1st quality conforming to IS: 15622 of approved make in all Colours& shades, except burgundy, bottle green, black laid on 12mm thick bed of Cement Mortar 1:3 (1 Cement: 3 sand)preprad same day when mortar is still green jointed with grey cement slurry @3.3 kg per sqmincluding pointing the joints with white cement and matching pigments etc., complete. SOR NO 11.49 |
| 38 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, UPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :..White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. SOR NO 17.1.1 |
| 39 | Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification 2x2.5 Sq.mm. (Using flush type normal accessories) ) SOR NO 4.3.1 |
| 40 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. SOR NO 13.64 Please Enable Macros to View BoQ information |