| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) level : |
| 2 | 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) |
| 3 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc.Kiln seasoned and chemically treated hollock wood. |
| 4 | Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).6 mm thick Cement bonded wood particle board as per IS:14276 |
| 5 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : Kiln seasoned and chemically treated hollock wood 50x20 mm |
| 6 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :15.13.1 Of area 3 sq. metres and below |
| 7 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.3 Kiln seasoned and chemically treated hollock wood |
| 8 | Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching wood beading |
| 9 | Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with :10.30.1 4.0 mm thick glass panes |
| 10 | Labour Only Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : Old work (one or more coats) Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 11 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade |
| 12 | Dismantling G.S Sheet roofing incl. ridges, hips, valleys and gutters etc, and stacking the materials within 50m lead.Asbestos Cement sheet |
| 13 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required |
| 14 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Ridges plain (500 - 600mm) |
| 15 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade |
| 16 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. asrequired. |
| 17 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 18 | Supplying and drawing 3 x 2.5 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 19 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.(i) 5/6 amps switch |
| 20 | Supplying and drawing 3 x 2.5 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (ii) 3 pin 5/6 amp socket outlet |
| 21 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.(iii) 15/16 amp switch |
| 22 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.(iv) 6 pin 15/16 amp socket outlet Please Enable Macros to View BoQ information |