| 1 | Excavation in trenches not exc 1.50m deep and 1.50 mtr wide and getting out in hard/dense soil, complete all as specified and as directed. |
| 2 | Excavation in post holes (or similar holes) in hard/dense soil each n.exc 0.5cum getting out, returing, filling in and raming earth/broken rubble mixed with earth around, in layers n.exc 25cm, watering and removing surplus soil to a distance n.exc 50m and making good surface in soft/loose soil , complete all as specified and as directed. |
| 3 | M&L Plain Cement concrete Type D-2, 1:4:8 (40mm graded aggregate), in foundation, filling and mass concrete, complete all as specified and as directed. |
| 4 | M&L Plain Cement concrete Type B-2, 1:2:4 (40mm graded aggregate), in foundation, filling and mass concrete, complete all as specified and as directed. |
| 5 | M & L for brick work with sub class 'B' bricks (old sizes) straight or curved on plan exc 6 mtr mean radius built in CM 1:6 , complete all as specified and as directed. |
| 6 | M & L Rendering 10 mm thick in cement and sand mortar 1:6 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified and as directed. |
| 7 | M & L Rendering 15 mm thick in cement and sand mortar 1:4 on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing with using integral waterproofing compound @ 3% by weight of cement including finishing the surface even and smooth without using extra cement complete all as specified. (Note - W P C shall be measured and paid separately). |
| 8 | Preparation of newly plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and as directed. |
| 9 | M&L for preparing newly plastered surfaces of walls , applying two coats of distemper oil emultion, white ot tinted, complete all as specified and as directed. |
| 10 | M&L for Sand filling under floors or in foundations including watering and consolidation, complete all as specified and as directed. |
| 11 | M & L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed. |
| 12 | M&L 75 mm thick Cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring, complete all as specified and as directed. |
| 13 | M & L 25 mm thick PCC 1:2:4 type B-1, using 20 mm graded stone aggregate, including finishing surface of concrete topping even and rough as sub base, complete all as specified and as directed. |
| 14 | M & L Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement and sand mortar 1:4, complete all as specified and as directed. |
| 15 | M & L Glazed ceramic tile 450 x 300 x 6-7mm thick (coloured) on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick plaster in cement and sand mortar 1:4, complete all as specified and as directed. |
| 16 | S&F Framed brackets of angles or tees, rafter purlins with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165, complete all as specified and as directed. |
| 17 | S&F mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat ections) including distance pieces, cleats etc complete all as specified. Fe 410 Gde -250, complete all as specified and as directed. |
| 18 | M & L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as etc, complete all as specified and as directed. |
| 19 | M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 20 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe.290.Gde-E-165 , complete all as specified and as directed. |
| 21 | Mild steel, plain, black sheet 1mm thick in wall cladding, steel gates and similarwork, cut to size, holes punched; includinground headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams,including bending or turning up, mitred angles, etc. as required, complete all as specified and as directed. |
| 22 | M&L for preperaring surfaces of newly or previously untreated steel or iron surfaces of any description over 10 cm in width or girth not otherwise described and apply two coats of sythetic enamel paint over a coat of red oxide primer, complete all as specified and as directed. |
| 23 | Returning filling in incl spreading leveling, watering and well ramming in layers n exc 25 cm, complete all as specified and as directed. |
| 24 | Removing of excavated soil exc.50 m but n exc. 250 m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as specified and as directed. |
| 25 | S&F welded steel wire fabric to steel member of weight n.exc 4 Kg per Sqm of 50mm pitch and 3.8mm dia, complete all as specified and as directed. |
| 26 | M&L for joist, channel ,angle or tee sections fixed independently without connecting plates etc complete conforming to Fe 410 Gde E 250, complete all as specified and as directed. |
| 27 | M&L pre-cast cement concrete Type B-1, 1:2;4, (20 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands etc , complete all as specified and as directed. |
| 28 | M&L for providing precast cement concrete type B-1, 1:2:4 (20mm graded aggregate) and set in cement mortar 1:6 in landings, cover slabs (for manholes/ drain cover) etc, complete all as specified and as directed. |
| 29 | M&L TMT bars 10mm dia and over cut to length, bend to shape required including cranking, bending spirally for hookings for cols, hooking ends and binding with and including mild steel wire (aneeled) not less than 0.9mm dia, complete all as specified and as directed. |
| 30 | All as per itemNo. 29 above but 5mm dia and above including 10mm dia in stirrups, complete all as specified and as directed. |
| 31 | S&F 2nd class soft wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed. |
| 32 | S&F 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle boarde with commercial veneering on both faes. The size of rail and stile (second class hardwood) as per IS-1003 (part-I), kiln seasoned and chemically pressure treated, complete all as specified and as directed. |
| 33 | S&F 2nd class soft wood glazed and skeleton shutters 35 mm thick , open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and as directed. |
| 34 | S&F Glazed and skeleton shutters thickness 30 mm,(2nd class softwood), open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters supplied and fitted to chowkats if windows, ventilators, etc. are provided with stiles and rails as in SSR Part I, Section specified 8 clause 8.24(b) , complete all as specified and as directed. |
| 35 | Preparation of newly or previously untreated wooden surfaces of any description over 10 cm width or girth and priming with pink primer ovder two coats of synthetic enamel paint on wooden surfaces, complete all as specified and as directed. |
| 36 | S&F 300mm long long aluminium alloy, anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast alouminiu alloy and fixed, complete all as specified and as directed. |
| 37 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average wide of aperature 1.40mm and fixed with stainless steel wire staples etc, complete all as specified and as directed. |
| 38 | S&F 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and as directed. |
| 39 | S & F Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked, complete all as specified and as directed. |
| 40 | S & F Butt hinges, 75 mm long medium weight, cold rolled mild steel, ISI marked , complete all as specified and as directed. |
| 41 | S & F Butt hinges, 50 mm long medium weight, cold rolled mild steel, ISI marked, complete all as specified and as directed. |
| 42 | S & F 150mm long aluminium anodised, barrel tower bolt ISI marked, complete all as specified and as directed. |
| 43 | S & F 100mm long aluminium anodised, barrel tower bolt ISI marked, complete all as specified and as directed. |
| 44 | S & F 150mm long aluminium anodised cast type alumiinium handle SI marked, complete all as specified and as directed. |
| 45 | S & F 100mm long aluminium anodised cast type alumiinium handle SI marked, complete all as specified and as directed. |
| 46 | M & L 75mm thick PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cemen, complete all as specified and as directed. |
| 47 | S&F 3 layer PPR pipes 25mm dia abore SDR 7.4 & SDR 11 UV staablished and antimicrobial welded having thermal stability for hot and cold water, complete all as specified and as directed. |
| 48 | S&F 3 layer PPR pipes 20mm dia abore SDR 7.4 & SDR 11 UV staablished and antimicrobial welded having thermal stability for hot and cold water, complete all as specified and as directed. |
| 49 | S&F 500 Ltrs capacity Rotational moulded polyethylene in white coloured three layered ISI marked water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as per specified and directed. |
| 50 | S&F 25mm PPR Gate valve inserted as per requirement of site, complete all as specified and as directed. |
| 51 | S&F 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (min weight 20mm-210 gms), complete all as specified and as directed. |
| 52 | S&F 15mm bore Bib taps, fancy type chromium plated with crutch or butterfly handle, screwed down, serewed for iron pipe or for brass ferrule and fixed, complete all as specified and as directed. |
| 53 | S&F 15mm bore Angle valve, fancy type chromium plated high pressure with crutch or butterfly handle screwed both ends for iron pipe, complete all as specified and as directed. |
| 54 | S&F mild steel framed work such as grills, frame work of water taks FE 290 Gde E-165, complete all as specified and as directed. |
| 55 | S & F for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 110 mm bore of pipe, complete all as specified and as directed. |
| 56 | S & F for PVC (SWR) gully trap, plain with grating including jointing with solvent cement 110 mm bore, complete all as specified and as directed. |
| 57 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out hard dense soil , complete all as specified and as directed. |
| 58 | Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as specified and as directed. |
| 59 | Hard core of broken stone or boulder of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified and as directed. |
| 60 | M&L for 75mm thick cement concrete type C-2, 1:3:6 (40mm graded agrregate) as in sub base of floors, finished even and fair over well/rammed/compacted earth, complete all as specified and as directed. |
| 61 | M&L 25mm thick Sand filling under floors or in foundations including watering and consolidation, complete all as specified and as directed. |
| 62 | S & F Chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors including screed bed 15mm thick comple in CM 1:4, complete all as specified and as directed. |
| 63 | M&L for providing cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in roof kerbs or mud stop, rounded or chamfered on edges, complete all as specified and as directed. |
| 64 | M&L for Point wiring with 1.5 Sqmm multistrand, FRLS copper conductor cable, PVC insulated and unsheathed, drawing in and including PVC concealed conduit 20 mm dia medium grade ISI marked with all accessories such as bends, elbows reducers, pressed steel/ MS terminal boxes factory made 1.6 mm thick dully painted in rectangular shape appropriate size (having wall thickness of conduit not less than 2.00 mm) for one light/ fan point controlled by one 5 Amps switch one way, covered with 3 mm thick plastic laminated sheet top cover for mounting switches, sockets requlators etc and continous PVC insulated and unsheathed 1.5 Sqmm copper conductor cable multistrand as earth wire, complete all as specified. |
| 65 | All as per serial item No. 64above but 3 pin 5 Amp switch socket outlet on same board. |
| 66 | All as per serial item No. 64 above but 3 pin 5 Amp switch socket outlet on independent board. |
| 67 | All as per item No.64 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multy stranded, FRLS grade and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS grade as earth lead. |
| 68 | Supply and fixing LED lights fittings 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed. |
| 69 | Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body, complete all as specified and as directed. |
| 70 | S&F Lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked), complete all as specified and directed. |
| 71 | S&F LED light fitting 1x10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed. |
| 72 | S&F exhaust fan, steel body AC single phase, 230V of size 300mm sweep with, blades, and frame and louvers, complete all as specified and as directed. |
| 73 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V, 1200mm sweep BEE 5 star rated with brushes direct connect motor, complete all as specified and as directed. |
| 74 | S&F LED bulb inverter type of capacity 9 watt (ISI marked) complete with all accessories base, complete all as specified and as directed. |
| 75 | S&F Switch piano flush button single pole one way 5 Amps, complete all as specified and as directed. |
| 76 | S&F switch piano Flush type, single pole, 15 amp 240 volts, complete all as specified and as directed |
| 77 | S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed. |
| 78 | S&F Socket outlet 2 in 1, 3 pin, 5and 15 Amps, flush type complete all as specified and as directed. |
| 79 | Supply and fix sheet metal enclosures for DBs when MCBs to used single pole & neutral (SPN) double door 240 volts, 8 way incl. 200 Amp bus bar and neutral link (ISI marked) complete all as specified and directed. |
| 80 | Supply and fix sheet metal enclosures for DBs when MCBs to used single pole & neutral (SPN) double door 240 volts, 12 way incl. 200 Amp bus bar and neutral link (ISI marked), complete all as specified and as directed. |
| 81 | Supply and fixing MCB SPN 63 Amps, 240V, 10KA 'C' curve and current carrying capacity in the MCB DB , complete all as specified and as directed. |
| 82 | Supply and fixing MCB SP 6-32 Amps, 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 83 | S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2KW capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc, complete all as specified and as directed. |
| 84 | Supply and fixing in wall mounted fans 300 mm swing high speed , 230 volts, 50 HZ, AC connecting up including provision of cable from connector to fan, complete all as specified and as directed. |
| 85 | M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, RFR and removal etc |
| 86 | M&L for Sub main wiring with 2 runs of 10 sqmm PVC insulated multi stranded FRLS copper cable drawn through PVC Conduit of required size with accessories along with 1 run of 10 sqmm copper cable as earth continuity conductor including taking down the old existing submain wiring complete all as specified and as directed.Note :- Two runs of 10 sqmm and one runs of 10 sqmm cable as earth along with PVC conduit will be measured as one length. |
| 87 | Supply & fix Mosquito Insect killer ,2 Tube ,12'', White, complete all as specified and as directed. |
| 88 | Supply & Fixing GI tubing, medium grade, ISI marked complete with all fittings, laid in trenches or laid under floors, fixed on walls with and providing clamps etc size 25mm dia bore, complete all as specified and as directed. |
| 89 | S & F valve, stop, screwed 25mm (1\\") dia pipe, complete all as specified and as directed. |
| 90 | Supply and laying XLPE insulated PVC FRLS, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area, galvanized steel strip or wire armoured, of size 50 Sq mm 3.5 core. (X'mer to Panel), complete all as specified and as directed. |
| 91 | Supply and laying XLPE insulated PVC FRLS, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area, galvanized steel strip or wire armoured, of size 25 Sq mm 2 core. Panel to cookhouse) |
| 92 | Excavation in trenches n exc 1.5 m wide & n exc 1.5 mtr deep in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holesetc not exc 50 sqm on plan and n exc 1.5 mtr in depth and getting out of soft/lose soil, complete all as specified and as directed. |
| 93 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and as directed. |
| 94 | Returning, filling in, including spreading, leveling, watering & well ramming in layers n. exc 25 cm, complete all as specified and as directed. |
| 95 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable, complete all as specified and as directed. |
| 96 | M&L for Sub class \\"B\\" bricks laid dry width wise across the line of cable in treanchs as cable protection, complete all as specified and as directed. |
| 97 | Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (Adm Block) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 200 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :- |
| 98 | (a) INCOMING |
| 99 | (i) MCCB 4 Pole 415 volts grade 160 Amps rating and 25 KA rupturing capacity - 01 No |
| 100 | (ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No |
| 101 | (iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No |
| 102 | (iv) CTs ratio 160/5A class ISI marked sets of three each |
| 103 | (v) Indicating lamp-01 set of three |
| 104 | (vi) change over switch 160 amp. |
| 105 | (b) OUTGOING |
| 106 | (i) MCCB 4 Pole 415 volts grade 63 Amps rating and 25 KA rupturing capacity - 02 No |
| 107 | (ii) MCCB DP 240 volts grade 63 Amps rating and 25 KA rupturing capacity - 01 No |
| 108 | (iii) MCB DP 10 TO 32 AMP - 6 Nos |
| 109 | Supply and install steel tubular pole type 410 SP-31 (9 mtr long) single swan neck type complete with CI base plate and finial and single swan neck including foundation and coping, complete all as specified and as directed. |
| 110 | Supply, fixing and testing LED street light fitting of 35 watt IP 66, complete all as specified and as directed. |
| 111 | Supply & fixing cubical type hot pressed moulded SMS of size 250 x 200 x 100 mm Sintex SMC/FRP juction box for street light pole mounted terminal box suitable for mounting on round pole and suitable arrangement for fixing bracket complete with one MCB SPN 6-10 amps capacity single pole and 200A Busbar SPN suitable to terminate loop in/out cables upto 25 sqmm , complete all as specified and as directed. |
| 112 | Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 2.5 Sqmm 1100 Volt , draw through LT steel tubular poles for connection to street light from junction box, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 113 | Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 2.5 Sqmm 1100 Volt , draw through LT steel tubular poles for connection to street light from junction box, complete all as specified and as directed. Please Enable Macros to View BoQ information |