| Sl. No. | Item Description |
| 1 | Surface excavation in soft/ loose soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed. |
| 2 | Excavating in trenches, in soft/loose soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables and pipes etc. not exceeding 10Sqm on plan and not exceeding 1.5m in depth and getting out complete aii as specified and as direcetd. |
| 3 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceding 25cm in soft/loose soil complete all as directed. |
| 4 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 5 | M&L for 25 mm thick Sand filling under Interlocking paver block including watering,consolidation and compaction with plate vibrator complete all as specified and as directed. |
| 6 | M&L for Hardcore of broken stones and boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 7 | M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammedincluding watering complete all as specified and directed. |
| 8 | M&L for Pre-construction Treatment to bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified. |
| 9 | M&L for Pre-construction Treatment to backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified. |
| 10 | M&L for Pre-construction Treatment to top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified. |
| 11 | M&L for Pre-construction Treatment tos oil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified. |
| 12 | M&L for Lean Cement Concrete (1:2:4) type B-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 13 | M&L for Lean Cement Concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete etc in sunken portion complete all as specified and directed. |
| 14 | M&L for Lean Cement Concrete (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 15 | M&L for Lean Cement Concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in surface channels and drains; benching of man holes complete all as specified and directed. |
| 16 | M&L for Lean Cement Concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in surface channels and drains; benching of man holes complete all as specified and directed. |
| 17 | M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc.as in manhole pipe line portion only complete all as specified and directed. |
| 18 | M&L for Reinforced Cement Concrete Design Mix M-25 Grade as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 19 | M&L for Reinforced Cement Concrete Design Mix M-25 Grade as in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 20 | M&L for Reinforced Cement Concrete Design Mix M-25 Grade as in Beams, cantilevers, bressummers, lintels over1.5m spancomplete all as specified and directed. |
| 21 | M&L for Reinforced Cement Concrete Design Mix M-25 Grade as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 22 | M&L for Reinforced Cement Concrete Design Mix M-25 Grade as in Chajjas and the like complete all as specified and directed. |
| 23 | Formwork for rought finished flat surface of concrete to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 24 | Formwork for rought finished flat surface of concrete to to sides of pillars, posts, struts, piers, columns and stanchionscomplete all as specified and as directed. |
| 25 | Formwork for rought finished flat surface of concrete to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed. |
| 26 | Formwork for rought finished flat surface of concrere to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping) kitchen platform complete all as specified and as directed. |
| 27 | Formwork for rought finished flat surface of concrete to rough finished surfaces of chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed. |
| 28 | Formwork for rought finished flat surface of concrete to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. |
| 29 | M&L for brick work built in cement mortar (1:6) with Fly ash bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. Note:- Unit rate qouted by the contractor shall be deemed to be included for Forming or leaving chases (or cutting instead at the option of the contractor where approved by EIC) for concealed water tubing and concealed conduit wiring, ends or edges of slabs, landings, shelves, sunshades, steps, cills and the like not exc. 50 cm in girth.; making or leaving holes for fixing pipes, bolts etc. and weep-holes, and making good, including grouting, if necessary. No claim whatsoever shall be entertained later on by the Department. |
| 30 | M&L for brick work built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 31 | M&L for brick work in half brick thick wall built in cement mortar (1:4) with Fly ash bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. Note:- Unit rate qouted by the contractor shall be deemed to be included for Forming or leaving chases (or cutting instead at the option of the contractor where approved by EIC) for concealed water tubing and concealed conduit wiring, ends or edges of slabs, landings, shelves, sunshades, steps, cills and the like not exc. 50 cm in girth.; making or leaving holes for fixing pipes, bolts etc. and weep-holes, and making good, including grouting, if necessary. No claim whatsoever shall be entertained later on by the Department. |
| 32 | M&L for brick work in half brick thick wall built in cement mortar (1:4) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 33 | M&L Pre-cast Cement Concrete (1:2:4) type B-1 using 20mm graded stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, set in cemet mortar (1:4) including form work complete all as specified and directed. Note:- Reinforcement shall be measured and paid for separately. |
| 34 | M&L for Cast-in-Situ Plain Cement Concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in bed blocks for hold fasts roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work complete all as specified and directed. |
| 35 | S&F 2nd class softwood Plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, all as specified and directed. complete all as specified and directed. |
| 36 | S&F in Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x125mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of equired dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately), complete all as specified and directed.. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 37 | S&F in Factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star eaded counter sunk S.S screws, all as per direction of Engineer In- Charge. (Note: stainless steel butt hinges andnecessary S.S screws shall be paid separately) |
| 38 | S&F Providing 30mm thick factory made wire mesh solid WPC door shutters consisting of Density 650 Kg /Cbm Manufactured by an ISO-9001-2015 certified Company , Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose. (confirming as per IS:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. M.S powder coated butt hinges size 100mm*25mm*2mm and 32mm long steel screws drilled suitable to pass through both the walls of the M.S tube.Other hardwares should be fixed with 19*6mm size steel screws etc., complete as per direction of Engineer-in -Charge, manufacturer's specification & drawings. |
| 39 | S&F Anodised aluminium frame powder coated (minimum 50micron thickness of epoxy powder coating) for door, windows, ventilators and partitions with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 40 | S&F Anodised aluminium window and ventilator shutters, powder coated aluminium(minimum 50micron thickness of epoxy powder coating) side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified complete all as specified and directed. |
| 41 | S&F mild steel framed work with Fe.290.Gde-E-165, such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work complete all as specified and directed. |
| 42 | S&F 50mmx47mm size solid PVC door frame made out of 5mm plain colour PVC sheet reinforced with MS square tube, complete all as specified shown on drawing and specified and directed. |
| 43 | S&F factory made 30mm thick (style) solid panel PVC door shutter consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified shown on drawing and specified and directed. |
| 44 | S&F factory made PVC cup boards/ Shelf / Partition of required size consisting of panel of 18mm thick Celuka PVC Ply and for supporting the hold of Shelf/ Partition and shall provided 3 edges in size 18mm x18mm as per required length. The front side of the edge visible in the front of the shelf/ Partition to be edge lipped by 18mm width x 1mm thick PVC sheet using solvent cement etc. complete all as specified and directed. |
| 45 | S&F 40 mm dia, cupboard knobs fixed with nut , screw and washer of brass, polished complete all as specified and directed. |
| 46 | S & F 125 mm bright finished brass hasp and staple , safety type with mild steel hinge pin including bolt to hinge plate and fixed with screw.complete all as specified and directed |
| 47 | S&F Cabinet Catches, CP brass, bright finish or electrogalvanised complete all as specified and as directed. |
| 48 | S&F Godrej Cabinet hinges, CP brass, bright finish or electrogalvanised complete all as specified and as directed. |
| 49 | S&F 100mm size mild steel butt hinges medium weight rolled cold complete all as specified and directed. |
| 50 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section and fixed with steel screws complete all as specified and directed. |
| 51 | S&F 200mm long aluminium anodised barrel tower bolts of extruded section and fixed with steel screws complete all as specified and directed. |
| 52 | S&F 150mm size aluminium door handle, extruded aluminium alloy, fabricated type complete all as specified and directed. |
| 53 | S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 54 | S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, with 150mm overall length of cover plate fixed in floor complete all as specified and directed, |
| 55 | S&F 20mm dia Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed |
| 56 | S&F Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed. |
| 57 | S&F 4.0mm thick, plain sheet glass, ordinary quality and glazing, with oil putty or with wooden beads (supplied alongwith shutters), in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed. |
| 58 | S&F 4.0mm thick, Frosted glass, and glazing, with oil putty or with aluminum or mild steel beads (supplied alongwith shutters), in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed. |
| 59 | S&F Structural Steel Fe-410- W(Gde E-250) Quality 'B' Rolled sections framed work as in doors or gates or cooler stands of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete and similar work complete all as specified and directed. |
| 60 | S&Fstainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 61 | S&F 10mm dia and over mild steel TMT bars, in reinforcement bars, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. |
| 62 | S&F 6 to 8mm dia and over mild steel TMT bars, in reinforcement bars, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. |
| 63 | S&F 5mm dia and over upto and including 10mm dia mild steel TMT bars, in reinforcement stirrups, spacers and binders cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. but |
| 64 | M&L for 75mm thick Plain Cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints and expansion joints filled with bitumen mixed with sand in ratio (1:1) complete all as specified and directed. |
| 65 | M&L for 75mm thick Plain Cement Concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in sub base of flooring, surface finished even and fair, surface finished rough to receive floor topping complete all as specified and directed. |
| 66 | M&L for 40mm thick Plain Cement Concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in flooring, surface finished even and fair complete all as specified and directed. |
| 67 | M&L for 18 to 20mm thick Granite (table rubbed and mirror polished) in steps ,jambs,pillars,cooking platform and like including pointing in white cement 1:2 using marble dust with admixture of pigment to match with marble shade other than white and black types over a 20mm thick cement screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed. |
| 68 | M&L for 18 to 20 mm thick Baroda green marble in single piece incl nosing at front and sides in steps, jambs,pillars,window cills,cooking platforms,staircase and like with bull nosing incement mortar (1:4) including pointing in white cement(1:2) using marble dust with admixture of pigment to match with marble shade including making grooves for slip guard or steps,edge moulding,making 30 mm dia hole in cooking counter slab and green marble top for gas pipe including 15mm thick screed bed in cement mortar (1:4) and providing edge moulding to marble incl machine polishing to edge to finish etc complete all as specified and directed. |
| 69 | M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. |
| 70 | M&L for 10mm thick (square/ rectangular) Vitrified Tiles, light colour, polished, area of each tile not exceeding 0.36Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed. |
| 71 | M&L for 10mm thick (square/ rectangular) Vitrified Tiles, light colour, polished, area of each tile not exceeding 0.36Sqm, in vertical surfaces such as skirtings, dados, risers and steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed. |
| 72 | M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Coloured Tiles, Joint-free, premium quality, area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in vertical surfaces such as skirtings, dados, risers and steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed. |
| 73 | M&L for 7mm thick (Area 450 x 300mm / 450x350mm/ 350x250mm/300x200mm) Glazed Ceramic Coloured Tiles, in vertical surfacesX 7 mm th set and jonnted in cement slurry and pointed in white or coloured cement in vertical surfaces such as skirtings, dados, risers and steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed. |
| 74 | M&L for 80mm thick M-40 Grade Coloured Machine Pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of with grey cement and pigment complete all as specified and directed. |
| 75 | M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete complete all as specified and directed. |
| 76 | M&L for 12mm thick rendering cement plaster in cement mortar (1:6) on fair faces of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 77 | M&L for 15mm thick rendering cement plaster in cement mortar (1:4) on any faces of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 78 | M&L for 15mm thick rendering cement plaster in cement mortar (1:4) on other than fair faces of brick walls or concrete surfaces, mixed with water proofing complound as per manufacturer's instructions, finished even and fair without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately. finished even and smooth without using extra cement complete all as specified and directed. |
| 79 | M&L for 5mm thick rendering cement plaster in cement mortar (1:3) on ceiling surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 80 | M&L for 10mm thick screed bed or bedding layer in cement mortar (1:4) mixed with water proofing compound @ 3% by weight of cement or as per manufacturer's instructions, finished even and smooth without using extra cement on roof surfaces to have a smooth and uniform surface for laying of water proofing membrane complete all as specified and directed. . Note: WPC shall be measured and paid separately. |
| 81 | Supply only Integral water proofing compound complete all as specified and directed. ( Note:- WPC shall be mixed @ 3% by weight of cement or as per manufacturer's instructions whichever is more.) |
| 82 | M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqm over a coat of bitumen primer @ 0.30 litre per Sqm including preparation of roof surfaces/ sunken portion and all surfaces of sunken portion complete all as specified and directed. |
| 83 | M&L for One layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surfaceby forced application complete all as specified. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing.Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer's instructions.(ii) A minimum overlap shall be 75mm length wise and 100 mm width wise of polymeric membranes respectively and sealed all overlaps and joints as manufacturer's instructions. |
| 84 | M&L for preparation of surfaces of platered, brick, concrete, polymeric etc, of any description, over10cm in width or girth,not otherwise describedone and applying two coats of Solar Reflective Bituminous Aluminium paint @0.1 Kg/ Sqm over APP Membrane complete all as specified and directed. |
| 85 | S&F 1.00mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 86 | M&L for preparing new plastered surfaces of walls and distempering with two coats of distemper oil emulsion white or tinted over one coat of cement primer are surface even and smooth complete all as specified and directed. |
| 87 | M&L for applying 2.0 mm thick wall care putty omn surface of walls to prepare surface even and smooth complete all as directed. |
| 88 | M&L for preparing new plastered surfaces of walls and applying three coats of lime white wash complete all as specified and directed. |
| 89 | M&L for preparing new plastered surfaces of ceiling and applying three coats of lime white wash complete all as specified and directed. |
| 90 | M&L for for preparing new plastered surfaces of walls and applying two coats of Exterior Acrylic Emulsion weather proof paint white or tinted over a coat of cenet primer complete all as specified and directed. (Note:- Weatherproof painting shall be got executed through authorised applicator of the manufacturer and furnish seven years guarantee from the Manufacturer) |
| 91 | M&L for preparation of new wood or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed. |
| 92 | M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 93 | S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floors complete all as specified and directed. Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 94 | S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floor complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 95 | S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 96 | S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 97 | S&F 75mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 98 | S&F 110mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 99 | S&F 110mm dia PVC (SWR) distance pieces complete all as specified and directed. |
| 100 | S&F 110mm dia PVC (SWR) shoe complete all as specified and directed. |
| 101 | S&F 75mm dia PVC (SWR) bends any radius with oval type access door complete all as specified and directed. |
| 102 | S&F 110mm dia PVC (SWR) bends any radius with oval type access door complete all as specified and directed. |
| 103 | S&F 110mm dia PVC (SWR) Branch piece double (double \\"Y\\") equal or unequal complete all as specified and directed. |
| 104 | S&F 75mm dia PVC (SWR) Branch piece double (double \\"Y\\") equal or unequal complete all as specified and directed. |
| 105 | S&F 75mm dia PVC (SWR)Junction single (single or double \\"T\\") equal or unequal complete all as specified and directed. |
| 106 | S&F 110mm dia PVC (SWR)Junction single (single or double T) equal or unequal complete all as specified and directed. |
| 107 | S&F 75mm dia PVC (SWR) vent cowl complete all as specified and directed. |
| 108 | S&F 110mm dia PVC (SWR) \\"P\\" traps for Water Closets complete all as specified and directed. |
| 109 | S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 110 | S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 111 | S&F Stack clamps for 110mm dia pipe made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 112 | S&F Stack clamps for 75mm dia pipe made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 113 | S&F 16mm outer diameter CPVC pipes SDR 11 with and including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. (Note:- Special fittings shall be measured and paid for as \\"S&F\\" separately. |
| 114 | S&F 20mm outer diameter CPVC pipes SDR 11 with and including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. (Note:- Special fittings shall be measured and paid for as \\"S&F\\" separately . |
| 115 | S&F special fittings of Brass elbow for 16mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed. |
| 116 | S&F special fittings of Brass Tee for 16mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed. |
| 117 | S&F special fittings of Male Brass Threaded Adaptor (MTA/ MBTA) for 16mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed. |
| 118 | S&F special fittings of Female Brass Threaded Adaptor (FTA/ FBTA) for 16mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed. |
| 119 | S&F special fittings of Tank Adaptor for 16mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed. |
| 120 | S&F special fittings of Union for 16mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed. |
| 121 | S&F special fittings of Brass elbow for 20mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed. |
| 122 | S&F special fittings of Brass Tee for 20mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed. |
| 123 | S&F special fittings of Male Brass Threaded Adaptor (MTA/ MBTA) for 20mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed. |
| 124 | S&F special fittings of Female Brass Threaded Adaptor (FTA/ FBTA) for 20mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed. |
| 125 | S&F special fittings of Tank Adaptor for 20mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed. |
| 126 | S&F special fittings of Union for 20mm outer diameter CPVC pipes SDR 11 & plain CPVC SDR 11 complete all as specified and directed. |
| 127 | S&F 15mm bore Bib Taps, long body fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 128 | S&F 15mm bore Angle Valves, fancy type, chromium plated, cast copper alloy, with flange, one way turn, screwed down high pressure, with crutch or butterfly handle, screwed for iron pipe complete all as specified and directed. |
| 129 | S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and directed. |
| 130 | S&F 15mm PVC connections 450mm long heavy duty with brass nuts adaptors and washers and rubber gaskets at both ends complete all as specified and directed. |
| 131 | S&F 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), five layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. screwed for iron pipe or brass ferrule complete as specified in SSR Part-I. complete all as specified and directed. |
| 132 | S&F 20 mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 133 | S&F Baroda Green Marble Counter Top of approved quality,machine polished,minimum 18 mm thick, 1200 mm long, 550 mm wide having elegant appearance and comfortable usage, with moulded and polished exposed edges including necessary cuttings for wash basin and mixer,fixed over suitblle heavy duty MS brackets/ supports with white cement slurry and cement mortar 1:3 bedding complete including vitreous china Counter Top wash basin, white, of size 550 mm X 400 mm (minimum) complete with CP brass waste coupling & bottle trap and also including CP brass chrome plated single lever wash basin mixer with hot and cold water arrangment, ceramic cartridge, braided connection pipes, angle valves, check nuts and allied fittings complete all as specified and as directed. |
| 134 | S&F one piece vitreous china wash down water closet white or coloured, pedestal pattern, size approximately 640 mm x 360 mm x 690 mm complete with integrated low noise dual flush cisteren, soft close PP seat cover , jet arrangment, flush pipe, inlet connection pipe, S-trap/ P-trap of 220 mm projection, all internal flushing mechanisms, hinges, rubber gasket, rag bolts, fixing screws and all necessary arrangments complete all as specified and as directed.Make :- Jaquar/ Parryware/ CERA or Equivalent |
| 135 | S&F Vitreous China urinals, half stall (back or corner wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete including all joints and making good to floors complete all as specified and directed. |
| 136 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified complete all as specified and directed. |
| 137 | S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms)complete all as specified and directed. |
| 138 | S&F 32mm bore Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm 45gms/40mm-60 gms) complete all as specified and directed. |
| 139 | S&F 100mm dia of chromium plate steel grating doom fixed over trap with white cement complete all as specified and directed. |
| 140 | S&F125mm dia Chromium plated brass shower rose with swivel joints, any colour including shower arm 15mm dia, 195mm long with bend of 45 degree with flange of chromium plated brass including fixing complete to steel pipe or union complete all as specified and directed. |
| 141 | S&F Stainless Steel (AISI-304) Shower drain with Cockroach Trap (450 x 75mm) heavy duty including all fittings and fixed with white cement fixed complete all as specified and directed |
| 142 | S&F 900mmx750mm size of specified thickness looking mirror, bevelled edge of selected quality glass with aluminium frame made of channel around, mounted on 6mm thick commercial ply or AC building board, fitted to wooden plug with chromiumplated brass screws and cup washers complete all as specified and directed. |
| 143 | S&F 20mm dia brass chromium plated tubular towel rail 600mm long between flanges type \\"D\\", with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms)complete all as specified and as directed. |
| 144 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 145 | S&F Chromium plated Soap dish of stainless steel of size 160x160mm x 1mm thick, fixed to wll with CP brass screws and PVC gutties complete all as specified and directed. |
| 146 | S&F Central hole basin mixer for wash hand basin including all fittings ie including connection pipe as per manufactures specification complete all as specified and directed. (Make:- Jaquar/ Kohler/ Cera / Parryware or equivalent. |
| 147 | Cutting into existing manhole for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC (1:2:4) type B-1, smooth finished and reforming benching as required for internal pipe of dia 150 mm complete all as specified and directed. |
| 148 | M&L for cement concrete (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in concrete bed for 150 mm bore reinforced cement concrete pipes including packing under haunching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 149 | S&F 150 mm bore Reinforced concrete pipes, class NP-2, laid and jointed complete with collars laid in trenches and jointed complete all as specified and directed. Note:- Excavation, Earth work and Concrete bed shall be measured and paid separately) |
| 150 | M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) in and including 20mm dia non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing mild steel pressed / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 1.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for the followings :- (a) One light/fan/Bell Point controlled by one single pole one way switch. |
| 151 | ditto all as per item No 150 above but for one socket outlet on the same board controlled by one single pole one way switch |
| 152 | ditto all as per item No 150 above but for one 5 amps socket outlet independent controlled by one single pole 5 Amp switch. |
| 153 | M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 4.0 Sqmm (nominal area) in and including non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing mild steel pressed / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 4.0 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for one 3/5 pin 15 Amps switch socket out let on the independent board controlled by one single pole one way switch. |
| 154 | S&F Modular Switch, one way, 6A, module complete all as specified and directed. |
| 155 | S&F Modular Switch, one way, 16A, module complete all as specified and directed. |
| 156 | S&F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 157 | S&F Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 158 | S&F Modular white cover plate with frame, 1 module complete all as specified and directed. |
| 159 | S&F Modular white cover plate with frame, 2 module complete all as specified and directed. |
| 160 | S&F Modular white cover plate with frame, 3 module complete all as specified and directed. |
| 161 | S&F Modular white cover plate with frame, 4 module complete all as specified and directed. |
| 162 | S&F Modular white cover plate with frame, 6 module complete all as specified and directed. |
| 163 | S&F Modular white cover plate with frame, 8 module complete all as specified and directed. |
| 164 | S&F Modular Metal Flush Box, 1/2 module complete all as specified and directed. |
| 165 | S&F Modular Metal Flush Box, 3 module complete all as specified and directed. |
| 166 | S&F Modular Metal Flush Box, 4 module complete all as specified and directed. |
| 167 | S&F Modular Metal Flush Box, 6 module complete all as specified and directed. |
| 168 | S&F Modular Metal Flush Box, 8 module complete all as specified and directed. |
| 169 | S&F Modular Metal Flush Box, 3 module complete all as specified and directed. |
| 170 | S&F Modular Bell Push 6A, I module complete all as specified and directed. |
| 171 | S & F Modular step type regulator,120 W - 2 module complete all as specified and directed. |
| 172 | S&F Ceiling Roses Ceiling rose, 3 phase/PVC/polycarbonate, isolated body omplete all as specified and directed. |
| 173 | S&F Lamp holder PVC/Polycarbonate,isolated with back plate suitable for batten fittings ISI marked complete all as specified and directed. including 10W LED Bulb omplete all as specified and directed. |
| 174 | S&F bell, Ding Dong AC. 230 Volts, single pole complete all as specified and directed. |
| 175 | Supply, hoist, fix and connect Ceiling Fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 176 | S&F 250mm sweep Exhaust Fan, sturdy Engineering plastic body with louvers AC single Phase. 230V with blades and frame and louvers with Copper winding complete all as specified and directed. |
| 177 | S&F LED bulb 9/10 Watt B-22, 65000K, pin type complete all as specified and directed. |
| 178 | S&F in repairs LED light fiting 1x 20 W, 230 Volts, AC, decortive box type with driver holder including LED tube light, connected up with three core flexible copper conductor PVC cable of suitable size, from ceiling rose, including taking down, complete all as specified and directed. |
| 179 | S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed. |
| 180 | S&F in repairs sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired VTPN DBs (Verticle type)fitted with ABS frame, 415 Volts 200Amps rated bus bar,Neutral link,Earth bar and Din rail, 4 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 181 | S&F in repairs sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired TPN DBs, 415 Volts 200Amps rated bus bar,Neutral link,Earth bar and Din rail, 4 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 182 | S&F in repairs sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs, 240 Volts 200 Amps rated bus bar,Neutral link,Earth bar and Din rail, 8 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 183 | S&F Moulded Case Circuit Breaker (MCCB) Four Poles (FP) current carrying capacity 63Amp, 415 Volts, breaking capacity 16 KA with adjustable thermal and magnetic settings, complete all as specified and directed. |
| 184 | S&F Miniature Circuit Breaker (MCB) Single Pole (SP) current carrying capacity 6 to 32 Amp, 240V, breaking capacity 10 KA, type 'B' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 185 | S&F Miniature Circuit Breaker (MCB) Single Pole and Neutral (SPN) current carrying capacity 40 Amp, 240V, breaking capacity 10 KA, type 'C' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 186 | S&F Miniature Circuit Breaker (MCB) Single Pole and Neutral (SPN) current carrying capacity 63Amp, 415V, breaking capacity 10 KA, type 'C' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 187 | S&F in repairs Single Pole two Pin and Earth Plug and Socket including one single pole MCB 20 Amp fixed in and including sheet Metal enclosures, including taking down, complete all as specified and directed. |
| 188 | M&L for submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size 4.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 4.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cable single core for continuous earthing complete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 4.0Sqmm and one run of 4.0Sqmm PVC insulated copper conductor single core (2x4.0Sqmm+1x4.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run) |
| 189 | S&F Electronic Energy Meter temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed. |
| 190 | M&L for Earthing complete with Galvanised Iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at (Earth pit not less than 2.25m deep below ground level) a depth not less than 2.25m below normal ground level with top edge of earth plate at depth not less than 1.5m below normal ground level surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using 4mm dia galvanised earth wire by means of bolts, nuts, check nuts and washers of galvanized iron and protected by 15mm bore GI pipe light grade connected to main switch board or main control board and 20mm bore GI pipe light grade for watering and including funnel, wire mesh, 80mm thick pre-cast RCC (1:2:4) type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4Kg/Sqm in lieu of CI cover, PCC (1:2:4) type B-1 pit/chamber including all necessary excavation: and earth work, form work, disposal of surplus soil to a distance not exceeding 50m all as specified and al shown in Electrical Plate No.3 of MES Standard Schedule of Rates 2009 Part-I complete all as specified and directed.Note:- (i) The unit rate shall deemed to include for Test point, PCC pit, 4mm dia GI earth wire from top of the earth plate up to 7.5m above ground level. In case 15mm bore GIprotection pipe required is less than 7.5m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate.(iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. |
| 191 | Note : All building construction works under this contract shall be executed as per BoQ items and specifications. Drawings are also enclosed for guidance and shall form part of the tender document. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail