| 1 | S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 2 | S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specified |
| 3 | Fixing only pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specified (Except sheeting) |
| 4 | Dismantling plain or corrugated Steel sheeting any gauge thickness including nainital or similar pattern roof covering complete all as specified and as directed. |
| 5 | Dismantling framed work timber scantlings 40 Sqcm and over in section, in any position complete all as specified and directed. |
| 6 | Dismantling framed work timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 Sqcm in sectio, in any position complete all as specified and directed. |
| 7 | M & L mild steel work as in tubular trusses including special shaped washer etc complete in using ERW or induction butt welded tubes confirming to IS 1161-1979 grade St-240 complete all as specified and directed. |
| 8 | Erection only mild steel work as in tubular trusses including special shaped washer etc complete in using ERW or induction butt welded tubes confirming to IS 1161-1979 grade St-240 complete all as specified and directed. |
| 9 | Dismantling wrought iron or mild steel / structural steel work of any description not otherwise provided for complete all as specified and directed. |
| 10 | S & F Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with attachment conforming to Fe-410-W and gde-E-250 as in gusset plate complete all as specified and as directed |
| 11 | S&F mild steel screw bolts (machine made) dia 16 to 20mm and length exc 22.5cm but n.exc 30cm with hexagonal or square heads at one end or screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and as directed |
| 12 | Taking down chowkat with shutter without taking off shutter from the frame exc 1.5 Sqm n.exc 4 Sqm each complete all as specified and as directed |
| 13 | Taking down chowkats with shutter (without taking off shutter from the frame) not exc 1.5 Sqm each complete all as specified and as directed |
| 14 | S&F 125X60mm size pressed steel door frames of doors with one or more rebates including necessary fixing lugs, hinges lock strike plate, etc complete as specified |
| 15 | S & F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides and covered on both side with 6mm thick decorative face veneer with lipping/frame to match all as specified and directed. |
| 16 | S&F factory made wire guazed (panel will be wire guazed in lieu of plain PVC sheet) PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top rails, bottom rails stiles & lock rail. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. The wire gauze shall be wrapped on an additional square 8 mm MS Solid tube and this tube shall be welded to MS tubes. The wire gauge shall be stretched to tighten firmly complete all as specified and directed. Note:- Wire cloth / wire mesh shall be measured seperately |
| 17 | S & F for factory made Solid PVC Door Frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing. |
| 18 | S&F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of framemade out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stile sand plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail;Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing |
| 19 | M&L for anodised aluminium power coated frame for doors, sliding window three track ,ventilator etc with one or more rebates including all jointing cleats,etc complete all as specified and directed. |
| 20 | M &L anodised aluminium powder coated (Thick not less than 50 micron) aluminium window and ventilator shutter, slide type without sash bars,aluminium section weighing 0.55 kg /m including necessary jointing cleats,glazing clips,ruber packing, anodised aluminium snap beading, screw, including all fitting etc complete all as specified and directed. |
| 21 | S&F 4.80 mm thick plain sheet glass, ordinary quality fixed with aluminium frame work exc 0.5 sqm in each pane Complete all as specified and directed. |
| 22 | S& F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples Complete all as specified and directed. |
| 23 | S&F framed work such as grills, grating, etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed baluster; walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 24 | S&F 300mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed. |
| 25 | S&F 200 mm long aluminum anodized barred tower bolts of extruded section Complete all as specified and directed. |
| 26 | S&F aluminium handle 150 mm long cast type anodised Complete all as specified and directed. |
| 27 | M&L for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge |
| 28 | M&L 8 mm thick non asbestos fibre cement building boards fixed or laid / inserted to timber / GI / aluminium framework with screws as including dismantling complete all as specified and directed. |
| 29 | M &L PCC 1:3: 6 type C1 using 20 mm graded single as in bed plates & filling in pressed steel door frame |
| 30 | S&F in repairs 20mm dia Curtain rod/ Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as directed and specified. |
| 31 | S&F Decorative type brass chromium platedb brackets support for holding curtain rods and corner to be fixed to ends of curtain rod fixing with screws complete. |
| 32 | M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 all as specified |
| 33 | M&L Brick work with sub class 'B' bricks straight or curved on plan any radius in half Brick thick wall built in cement mortar 1:4 complete all as specified and directed . |
| 34 | M&L for brick work with subclass 'B' bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 and pointed cement mortar 1:6 with using old size bricks(Except brick ) |
| 35 | M&L for brickwork with sub-class `B' brick straight or curved on plan to any radius in half brick thick walls built in CM 1:4 with using old size brick (Except brick ) |
| 36 | Demolition of brick work built in cement mortar all as directed |
| 37 | M&L Rendering 15 mm thick on other than fair faces of brick work or concrete sur-faces in cement mortar 1:6 for finished even and fair complete all as specified and directed |
| 38 | M&L Rendering 15 mm thick on fair faces of brick work or concrete sur-faces in cement mortar 1:4 using water proofing compound for finished even and smooth (without using extra cement) (WPC will be measured and paid separately) |
| 39 | Taking down cement plaster on Brick or concrete surfaces incl racking out joints hacking for key scrubbing down with water etc complete |
| 40 | M&L for prepration of new plastered surfaces of wall applying two coat of oil emulsion distemper over a coat of alkali resistant cement primer over 2mm thick of wall care putty to obtained smoothness of plastered surfaces complete all as specified and directed. |
| 41 | M&L preparation of new plastered wall surfaces and including applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 42 | M&L preparation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 43 | M&L for two coat of synthetic enamel paint (1st grade quality) over a primed new steel surfaces of girth 10 cm incl preparation of surfaces. |
| 44 | M&L for complete removal of existing treatment on plastered or unplastered surface of wall including brooming down or steel wire brushing, scrapping down smoke scoot, mould, moss and efflorescent salt, trading oil and greasy spot and applying one coat 2 mm thick of wall care putty and then applying two coats of distemper oil emulsion(OBD), white or tinted over a coat of priming coat (alkali resistant priming paint, on plastered surfaces, preparatory to distempering) after preparation of wall surfaces, complete all as specified and directed. |
| 45 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tiles exceeding 0.18 Sqm but n.exc 0.38 Sqm as in floor, etc and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 46 | All as per Sl item No 45 above but in skirting / dado etc. laid over and including backing coat 10 mm thick in CM 1:4. |
| 47 | M&L for coloured non-skid ceramic tiles 7 to 8 mm thick, premium quality conforming to relevant IS (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:6), complete all as specified and directed. |
| 48 | M&L for glazed ceramic colouered tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick as in vertical surface such as risers of steps, skirting, dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 10 mm thick rendering in cement mortar (1:4) finished even and rough, complete all as specified and directed. |
| 49 | Dismantling of floor, hearth or wall tiles including cement mortar bedding ( but not backing) and remvoing rubbish off the premishes all as per specified and directed. |
| 50 | M&L for 50 mm thick plain cement concrete(1:3:6), type C2 (40 mm graded stone aggregate) as in flooring, plinth protection, hard standing, path etc including finish the surface rough to receive screed bed, complete all as specified and directed. |
| 51 | M&L for reinforced cement concrete (nominal mix) (1:2:4), type B1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. |
| 52 | M&L for RCC B1 1:2:4 with using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 53 | M&L for RCC (nomial mix) type B1 1 :2:4 with using 20mm graded stone agg as in Chajjas complete all as specified and as directed. |
| 54 | Demolition of RCC in any description description and in any position complete all as specified and as directed. |
| 55 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, slab cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc and finished rough surfaces of concrete flat complete all as specified and as directed. |
| 56 | M&L for Formwork to sides of rough finished flat surfaces of concrete chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed. |
| 57 | Formwork to soffits of suspended slabs such as roof slabs , floorslabs ,landing and similar work not exc 200 mm thick (horizontal or slope) complete all as specified and as directed. |
| 58 | M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. |
| 59 | All as per Sl item 58 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed. |
| 60 | Supply only liquid water proofing compound complete all as specified and directed. |
| 61 | S&F 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 62 | M&L for 18 mm thick plywood, grade BWR, type BB, fixed with scres to timber frame work complete all as specified and as directed. |
| 63 | M&L for 0.9 mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and as directed. |
| 64 | Dismantling boarding, any description fixed in any position with nails/screws including frame work complete all as specified and as directed. |
| 65 | S&F 75mm long Butt hinges extruded brass with brass/bronze hinge pin, bright polished and fixed complete all as specified and as directed. |
| 66 | S&F 75mm long Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and as directed. |
| 67 | S & F for CP decorative type Brass handles, cast type, polished bright handles 75 mm long fixed to plywood or frame complete all as specified and directed |
| 68 | S & F for magnetic and connected plate to shutter and frame as per sample complete all as specified and directed |
| 69 | M&L for providing precast cement concrete (1:2:4), type B-1 (using 20mm graded stone aggregate) as in landings, cover slabs (for man holes, drain etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces with plain fair faces, including chamfers, weatherings, throating etc. and set in cement mortar (1:4), complete with joints to match the surface, inclding demoliton of old concrete complete all as specified . |
| 70 | M&L for 75mm thick PCC(1:3:6) Type C2 using 40mm graded stone aggregate and finished even and smooth without using extra cement as in plinth protection complete all as specified and directed. |
| 71 | Demolition of cement concrete in ground floor and paving not exc 15 cm thick below or above ground level complete all as specified and directed. |
| 72 | M&L coloured ceramic heavy duty full digital paving tiles 10 to 12 mm thick (square/rectangular) polished, area of each tiles exc 0.11 sqm but not exc 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over including screed bed or bedding layer of mortar 15 mm thick for laying floor tiles in cement mortar 1:4 finished even and rough complete all as specified and as directed |
| 73 | M&L Chequered cement concrete tiles 30 cm x 30 cm x 25mm thick with grey cement and pigment set, jointed and pointed in neat cement slurry in floors over 15 mm thick Screed bed/bedding layer of 1:6 cement mortar completa all as specified and directed. |
| 74 | M & L 75 mm thick PCC 1:4:8 Type D-2 (using 40 mm graded aggregate) footpath/ sub base filing Complete all as specified and directed. |
| 75 | S&F in repair 600 mm x 600 mm frameless mirror (Elegant modern design) of selected quality glass not less than 5mmin thickness, wall mounted, rectangular type fixed with chromium plated brass screws and cup washers complete all as specified and directed |
| 76 | S&F in repair vitreous china, wash hand basin white flat back of size not less than 550 x 400 mm with and including PVC waste pipe 32 mm bore, CP waste fitting and cutting for and pinning in ends of brackets etc, complete all as specified and directed. |
| 77 | S&F in repair fancy type pillar tap 15mm dia, cast copper alloy with capstan heads, chromium plated screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shank and fly nut screwed for iron pipe complete all as specified and directed |
| 78 | S & F in repairs Stainless Steel Tubular towel rail , 20mm dia, 60cm long between flanges complete all as specified and directed. |
| 79 | S&F in repair Brass chromium plated shower rose 125mm size, including shower arm with or without swivel joints complete all as specified and directed. |
| 80 | S&F in repairs stop cock concealed type with long shank and cup of fancy type,chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of 15mm bore complete all as specified and directed |
| 81 | S&F in repair bib taps concealed type with long shank and cup of fancy type,chromium plated screwed down high pressure with crutch or butterfly handle screwed for iron pipes of 15mm bore complete all as specified and directed |
| 82 | S&F in repair stop/ Angle valves fancy type,chromium plated cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of 15mm bore complete all as specified and directed |
| 83 | S&F in repair vitreous china squating pan \\"Orissa\\" patern size 580 x 440mm white with 'P' or 'S' trap front or back inlet with integral foot rest (excluding flushing cistern and flush pipe), squating pan including connection to trap and flushing pipe, anit syphonic pipe etc complete incl making good to floor complete all as specified and directed |
| 84 | S & F in repairs Vitreous China wash down water closet pan (pedestal pattern), white in colour with fixing bolts and flush pipe, connection to trap and to flushing cistern and all joints, including plastic water closet seat cover white, closed pattern with flat bottom and cover and mild steel CP hinges complete all as specified and directed. |
| 85 | S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect, complete all as specified and directed |
| 86 | S&F in repairs PVC valve less flushing cistern low level 10 litres capacity with syphonic action type with inlet ball valves, float and handle and connections to pipes and fixing of chain and pull (or) lever including brackets and 32mm dia PVC flush pipe of 60cm long complete all as specified. |
| 87 | S& F in repairs Chromium plated Soap dish any type fixed to plugs with CP brass screws complete all as specified. |
| 88 | S & F PVC connection 15 mm size with PTMT Nuts of length 450 mm complete all as specified. |
| 89 | M&L for PVC waste pipe with 32 mm dia bore with one end socket for WHB/urinal/sink as in repairs complete all as specified and directed |
| 90 | S&F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed |
| 91 | S&F in repairs corner glass shelf assembly consisting of 5.5 mm thick sheet glass shelf, & side not less than 300mm with ABS chromium plate bracket guard complete all as specified and directed. |
| 92 | S&F in repair 25 mm bore steel water tubes, medium grade, galvanised with and including all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor, including taking down existing pipe complete all as specified and directed. |
| 93 | S&F in repar 20 mm bore steel water tubes, medium grade, galvanised with and including all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor, including taking down existing pipe complete all as specified and directed. |
| 94 | S&F in repairs steel water tubing and connection medium grade 15 mm bore with all fitting fixed to wall or floors or in ceiling incl dismantling of old complete all as specified and directed. |
| 95 | S&F in repair 25 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified. |
| 96 | M&L cutting chases in brick wall, pinning in. making good to facings where required and pointing in CM 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exc. 10 cm girth complete all as specified and directed. |
| 97 | S&F in repairs rotational moulded polyethylene water storage tanks of 1000 Litres capacity, multilayered (cylindrical vertical with closed top) hoisted and fixed in position and including 20 mm dia nipple suitable for HDPE water tank (minimum weight 45 gm), 20 mm bore ball valves (minimum weight 210 gm) high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed to 20 mm bore pipe & locking with GI wire (to prevent monkey menace) to tank incl dismantling of old/ unserviceable tank complete all as specified and directed. |
| 98 | S&F in repairs rotational moulded polyethylene water storage tanks of 500 Litres capacity, multilayered (cylindrical vertical with closed top) hoisted and fixed in position and including 20 mm dia nipple suitable for HDPE water tank (minimum weight 45 gm), 20 mm bore ball valves (minimum weight 210 gm) high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed to 20 mm bore pipe & locking with GI wire (to prevent monkey menace) to tank incl dismantling of old/ unserviceable tank complete all as specified and directed. |
| 99 | M &L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement as in repairs. |
| 100 | M &L 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solven cement as in repairs Complete all as specified and directed. |
| 101 | S&F PVC (SWR) pipe 110 mm bore single socketed in any length with rubber ring joint fixed to wall including taking down of old material as in repairs Complete all as specified and directed. |
| 102 | S&F PVC (SWR) pipe 110 mm bore laid in trenches or in floor.with rubber ring joins in repairs Complete all as specified and directed. |
| 103 | S&F PVC (SWR) pipes 75 mm single socketed, in any length with rubber ring joints, laid in trenches or in floors Complete all as specified and directed. |
| 104 | S&F PVC (SWR) pipes 75 mm single socketed, in any length with rubber ring joints, fixed with wall Complete all as specified and directed. |
| 105 | S&F PVC (SWR) bend 110mm access door in repairs. |
| 106 | S&F PVC (SWR) bend 75mm access door in repairs Complete all as specified and directed. |
| 107 | S&F in repair 75mm PVC (SWR), junction single, (Single T) equal or unequal with oval access door, complete all as specified and directed. |
| 108 | S&F in repair 110mm PVC (SWR), junction single, (Single T) equal or unequal with oval access door, complete all as specified and directed. |
| 109 | S&F in repair 75 mm PVC (SWR), vent cowl fixed in position complete all as specified and directed. |
| 110 | S&F in repair 110mm PVC (SWR), vent cowl fixed in position complete all as specified and directed. |
| 111 | S&F 4 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to Anodised aluminium snap grid frame size 605x605 mm work for false ceiling Hangers with 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed |
| 112 | M&L for 5 mm thick solid plain PVC sheet (latest design min and density 600 Kg/Cum) wall panelling, panels stuck on & including framework made out of 5 mm thick & 50 mm wide PVC strips (min density 600 Kg/Cum) fixed to wall vertically at 250 mm centre to centre & horizontally at 600mm centre to centre. PVC strips shall have 6 mm wide and 1 mm deep grooves in their centre for sinking the head of the screw & shall be fixed to wall using 65 mm long MS screws & PVC fasteners at a max distance of 200 mm centre to centre. PVC sheet panel shall be fixed to PVC strip framework using solvent cement & jointing of two PVC sheet panel shall only be done above PVC strip. Minimum size of one PVC sheet panel shall be 1220 (L) x 2440 (H) mm, however in case of complete height of wall panelling is more than 2440 mm, PVC sheet panel of length 1220 mm and balance height shall be fixed above lower panels complete all as specified and directed. |
| 113 | Demolition wall and ceiling boards (fibre, pulp, insulation, etc) or insulation oards/slabs/ blankets, any thickness including cover fillets etc complete all as specified and as directed |
| 114 | M & L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in marble dust with admixture white cement (1:2) using of pigment to match with shade of granite including cutting and polishing types over 20mm thick screed bed in CM(1:6) complete all as specified and directed. |
| 115 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc with laid bedded and pointed in any mortar complete all as specified and as directed. |
| 116 | Taking down carefully existing copper/aluminum point wiring ( Light, fan, socket or power) complete including fixture and fittings such as switches , ceiling roses , pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good the disturbed surfaces of walls, floors etc as per existing specification complete all as specified and as directed by Engr-in-Charge. |
| 117 | M & L for point wiring with two single core 1.5 sqmm concealed wiring ,PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) & incl fixing of modular metal flush boxes of appropriate size & thickness fixed flush to wall for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for modular boxes & making good the disturbed surfaces, matching to the existing one etc. complete all as specified & as directed for the following : |
| 118 | (a) One Light point controlled by one switch 5/6 Amps. |
| 119 | (b) One fan/exhaust fan point controlled by one switch 5/6 Amps. |
| 120 | (c) One switch socket outlet point 5/6 Amps on independent board. |
| 121 | (d) One switch socket outlet point 5/6 Amps on same board. |
| 122 | Description all as per Item No-2 above but with FRLS PVC insulated copper conductor cable of size 2.5 Sqmm and 2.5 Sqmm for earth continuity conductor green in colour for 16A switch socket and metal sheet enclosure DB including taking down of unsv ones complete all as specified and directed. Please Enable Macros to View BoQ information |
| 123 | Description all as per Item No-2 above but with FRLS PVC insulated copper conductor cable of size 2.5 Sqmm and 2.5 Sqmm for earth continuity conductor green in colour for 16A switch socket and metal sheet enclosure DB including taking down of unsv ones complete all as specified and directed. Please Enable Macros to View BoQ information |