| 1 | Dismantling, clearing away the brick/stone masonry in cement mortor wall under 3m high and carefully stacking materials useful for re-use for any thickness of walls. |
| 2 | Dismantling the RCC by manual/by using deploying machineries clearing away and carefully stacking materials useful for reuse for any thickness of walls. |
| 3 | Supplying and fabricating M.S Rectangular hollow tube section of size 80x40x3.20mm for purlin including welding works over one coat of red oxide primer etc., complete complying with standard specification and as directed by the University Engineer. |
| 4 | Supplying and fabricating M.S Rectangular hollow tube section of size 96x48x3.20mm for truss including welding works over one coat of red oxide primer etc., complete complying with standard specification and as directed by the University Engineer. |
| 5 | Supplying and fabricating M.S square hollow tube section of size 50x50x2.60mm for truss including welding works over one coat of red oxide primer etc., complete complying with standard specification and as directed by the University Engineer. |
| 6 | Supplying and roofing with colour coated galvalume sheets of 0.45mm thick (26 gauge) with necessary bolts, nuts and washers etc., including ridge sheets, cost of all materials, labour charges, conveyance charge welding charges etc., complete complying with standard specification. |
| 7 | Cement concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and three crushed stone sand) and kraft paper laid over it without claiming etc., complete complying with standard specification and as directed by the University Engineer. |
| 8 | Fly ash Bricks in cement mortar 1:5 (one cement and crushed stone sand) using fly ash bricks of size 230x110x70mm for the following items, including neat finishing, curing etc., complete complying with standard specifications. (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost) |
| 9 | Plastering with Cement Mortar 1:5 (one cement and crushed stone sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the university engineer. |
| 10 | Distempering the old wall and ceiling two coat with best oil bound distember of approved quality including preparation of surface, the rate includes cost of brushes, high scaffolding arrangements, neat finishes, etc., complete complying with standard specification and as directed by the University Engineer. |
| 11 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the University Engineer before use on works.) |
| 12 | Supplying and fixing aluminium anodised suspended FALSE CEILING system using Powder coated G.I section of size 25mm x 25mm x 1.20m supported along the wall all-round and inter connected with main frame using section of size 38mm x 25mm x 1.20mm at 1.20m both ways and cross supports with 25mm x 25mm x 1.20mm at 1.20m c/c both ways and suspended by means of 6mm M.S. rod one and threaded and the other end fixed on ceiling at 1.20m c/c both ways. The total area is covered with gypsum board of size 0.60m x 0.60m and laying aluminium tees and angles and board with necessary clips, jointing plats, screws etc., complete.(C.E.BLDGS) PWD approved rate) |
| 13 | Water proofing with TPO membrane - providing and laying 1.5 mm thick TPO membrane over old terrace having week surface/lime mortar. The membrance is manufactured using hot-melt extrusion process for complete scrim encapsulation. It is reinforced with a strong, polyester reinforced fabric centre (scrim) and a tough thermoplastic polyolefin compounded top ply and the bottom. It should have UV resistant top white colour which has a very high resistance to weather agents and UV rays. TPO membrane shall be plasticizer, cholrine & pthalate fre and should exceed/meet specifications of ASTM D6878. Membrane should be mechanically fixed to the substrate by independent plate and fasteners. TPO roof membrane should be lapped and seamed using hot air heat welding equipment after mechanically fastening the overlaps. Membrane should have following minimum properties, breaking strenth min. 220obf (976N) as per ASTM D751, Elongatin break of reinforcement>15% as per ASTM D751 and Tear strength 551 bf (245N) as per ASTM D751. The finished cost including surface preparation, application of TPO membrane over the 200 GSM Geo-textile and termination of TPO membrane using 2mm thick aluminium strip sealing with PU sealant at the top of strip completely as per specification. |
| 14 | Removing and clearing away the colour coated galvalume sheets of 0.45 mm thick (26 gauge) with necessary bolts, nuts and washers etc., including ridge sheets, cost of all materials, labour charges. |
| 15 | GST @ 18% Please Enable Macros to View BoQ information |