| 1 | Earth work in excavation for all type of foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent refilling around masonary etc. in 15 cms layers with compaction/consolidation, including disposal of all surplus soil as directed, within campus/site. |
| 2 | Earth filling under floors/in plinth with surplus soil excavated from foundations and taken only from outside the building plinth, in 15cms layers including ramming, watering and consolidating as directed by the Engineer-in-Charge. |
| 3 | Earth filling under floors/in plinth with approved earth brought from outside, in 15cms layers including ramming, watering and consolidating as directed by the Engineer-in-Charge. |
| 4 | Providing and fixing steel shuttering for faces of concrete foundations, footings, strips, pedestals, foundation beam, plinth beams (vertical, or battering) and columns etc, below plinth beam. Complete in all respects as directed by E-in-C. |
| 5 | Providing and laying plain cement concrete 1:4:8 using concrete mixture volumetric type with stone aggregate (1 cement: 4 coarse sand: 8 stone aggregate 40mm gauge) for all types of foundations, footings, below rafts, extension columns, plinth beams/under floor etc. including spreading, laying, ramming and consolidating as per requirements and curing etc. but excluding centering and shuttering, complete in all respects as directed by E-in-C. |
| 6 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 7 | Cold twisted deformed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete. |
| 8 | Providing & constructing Ist Class burnt brick work laid in cement sand mortar 1:6 (1 cement: 6 coarse sand) including scaffolding, watering, curing etc. complete in all respects, as directed by the E-in-C. |
| 9 | Providing and applying cement plaster to the walls, columns etc. including providing groove, drip course, scaffolding, finishing, curing etc. Complete in all respects for all heights as directed by the E-in-C. |
| 10 | 20mm thick cement plaster 1:5 in two coat work |
| 11 | Structural steel work in compound girders or Stanchions built up from two or more R.S. joists or channel section or plates & angles etc. including cutting and fixing all lattice bars, stiffeners, gusset plates, bolts, nuts, rivets, welding rod, etc. complete with flange plates, heads, sole plates, angle connections, etc. with hoisting and erecting in position. |
| 12 | Providing and erecting Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI Marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete having span:, complete in all respects as directed by E-in-C. |
| 13 | Providing and erecting Steel work in hip & jack rafters common rafters purlins etc. with angle cleats and other connecting plates, complete in all respects as directed by E-in-C. |
| 14 | Providing and fixing of Roof and Cladding Sheets: LYSAGHT® Tata BlueScope Steel’s COOL SHIELD TRIMDEK COLORBOND® XRW sheet (or any Equivalent Make) of nom.1072 mm supplied width and nominal 28.5mm deep ribs with subtle square fluting in the five pan at nominal 203 mm center-To Centre. The end rib shall be designed for anticapillary action, to avoid any seepage of water through the lateral overlap. The feed material is manufactured out of nominal 0.45MM BMT( Base Metal thickness), 0.50MM TCT (Total Coated Thickness), 0.53MM TPT(Total Painted thickness), Hi-Tensile steel with min. 550 MPa yield strength, metallic hot dip coated with Aluminum-Zinc alloy (55% Aluminum, 45% Zinc) as per AS1397- Zincalume AZ150 GSM (Min. 150 gms/sq.mt total on both sides) with Super Durable Polyester Colorbond XRW (THERMA TECH TECHNOLOGY) quality paint coat as per AS/NZS 2728 Class 3 of Tata BlueScope Steel make. The paint will have a total coating thickness of nominal 35 μm,comprising of nominal 20 μm exterior coat on top surface and nominal 5 μm reverse coat on back surface over nominal 5 μm primer coat on both surfaces of approved colour shade by concern authority. With 5mm XLPE Insulation. |
| 15 | Providing and filling in plinth and under floors approved local river sand including carriage loading, unloading, spreading, watering, ramming, consolidating, etc. complete as directed by the Engineer-in-Charge. |
| 16 | Providing and fixing in sheet rooting wind operated approved make of equivalent make 600mm dia turbo ventilators/roof extractors with sky light, made from rotating heads having turbine blades of higrade aluminium, Roofing and neck of stainless steel 304 grade steel bearing with dust proof housing of GP pushing instead of bearing UV stabilised non-coloured translucent 3mm thick FRP mouled one piece construction (monolithic) venturi dome and corrugated base sheet (similar FRP sheets 3mm thick UV resistant) of appropriate size having the profile matching with existing roof sheet with double action natural ventilation system powered by natural flow of air, boosts/extracts the hot and contaminated air/gases, obnaxious fumes, bad odour outside for healthy and improved environment inside godowns including cutting the root if necessary and fixing without leakage in root ete complete in all respects as directed by the E-in-C |
| 17 | Providing and laying Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand), complete in all respects as directed by the E-in-C. |
| 18 | Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together, at the end, by end locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed). |
| 19 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS clamps. |
| 20 | (i) U-PVC pipes (working pressure 4 kgf. / sqcm)pipe 110 mm dia. |
| 21 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 22 | (a) UPVC 110 mm bend |
| 23 | Providing and Erection of Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in PVC conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½\\" deep for walls and 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 24 | (i) Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade. |
| 25 | (ii) Wiring 3 pin 6 Amp. wall socket point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade |
| 26 | (iii) Wiring 3 pin 16/20Amp. power plug control point and switch |
| 27 | Supply and erection of Miniature Circuit Breaker MCB's Single Pole 6-32amp. (10kA, Curve-C) for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size ofthimbles/lugs:- |
| 28 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 29 | Overall size 1.5sq.mm (Un-sheathed) |
| 30 | Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 31 | HGW Conduit Pipe 25mm dia. (1.6mm thick) On Surface |
| 32 | Providing and laying 80mm thick factory made cement concrete interlocking paver block of M-40 grade rubber moulded smooth finish with strong vibratory process and of approved size and design, shape laid in Ordinary Grey Colour and pattern over and including 50mm thick compacted bed of course sand filling the joints with fine sand etc. complete in all respects to the entire satisfaction of E-in-C. |
| 33 | Plain cement concrete M-20 grade precast kerb 250mm high with bottom width 165mm and top width 115mm fixed in position on earth base including carriage to site of work complete as per technical clause 408 of MORT&H specifications complete in all respects to the entire satisfaction of E-in-C. Please Enable Macros to View BoQ information |