| Sl. No. | Item Description |
| 1 | PROPOSED DEVLOPMENT OF GURU MANDIR PREMISES AT KARANJA (LAD), DIST-WASHIM |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 3 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means |
| 4 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 3.0m to 4.5m) By Mechanical Means |
| 5 | Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. Up to 4Km |
| 6 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per One Square Metre of vertical surface area covering 10 years guarantee on bond paper. |
| 7 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten yearsguarantee on bond paper. |
| 8 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper. |
| 9 | Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. |
| 10 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. |
| 11 | Providing soling using 80 mm size trap metal in 15 cm layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. |
| 12 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade) |
| 13 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 14 | Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 15 | Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Upto Ground Floor |
| 16 | Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor |
| 17 | Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Second Floor |
| 18 | Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Upto Ground Floor |
| 19 | Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor |
| 20 | Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Second Floor |
| 21 | Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Upto Ground Floor |
| 22 | Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor |
| 23 | Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Second Floor |
| 24 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Upto Ground Floor |
| 25 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor |
| 26 | Providing cast in situ / ready mix M40 grade cement concrete for head walls of CD work / retaining walls etc. including necessary form work, compaction, finishing and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) with SCADA |
| 27 | Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Upto Ground Floor |
| 28 | Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor |
| 29 | Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Second Floor |
| 30 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Upto Ground Floor |
| 31 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. First Floor |
| 32 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Second Floor |
| 33 | Providing Water proofing treatment to newly laid fully cured concrete slab of terraces by applying first coat of polymer modified semi-viscous paste prepared by mixing polymer of approved make and Cement in 1 : 2 proportion ( 1 litre polymer : 2 Kg. Cement) to a neatly cleaned and dust free concrete surface and upto 300 mm. over parapet wall prepared by removing loose and deposited material with brush and water, laying glass fibre mesh of 10 x 10 specification of approved make over tacky surface of first coat of polymer followed by second coat in transverse direction, sprinkling coarse sand over it, followed by protective mechanical cover water proof plaster 20 mm thick after sufficient curing apply IPS 40 mm to 75 mm. thick cement concrete of 1:2:3 proportion using coarse aggregate of 10 MSA and water proofing compound of approved make and polypropylene fibres @ 125 gm per bag of cement making groovr 3 to 4 mm wide & 10 mm deep in concrete, in pannels of 3m/4m or as per site condition & filling the joints with poly sulphide sealant after curing including providing holler with drip moulds at the junction and finishing the concrete surface with neat cement slurry, as directed and ponding the surface as directed etc.complete ; covering 10 years guarantee against leakproofness on court Fee stamp paper of Rs 100/- First Floor |
| 34 | Providing Water proofing treatment to newly laid fully cured concrete slab of terraces by applying first coat of polymer modified semi-viscous paste prepared by mixing polymer of approved make and Cement in 1 : 2 proportion ( 1 litre polymer : 2 Kg. Cement) to a neatly cleaned and dust free concrete surface and upto 300 mm. over parapet wall prepared by removing loose and deposited material with brush and water, laying glass fibre mesh of 10 x 10 specification of approved make over tacky surface of first coat of polymer followed by second coat in transverse direction, sprinkling coarse sand over it, followed by protective mechanical cover water proof plaster 20 mm thick after sufficient curing apply IPS 40 mm to 75 mm. thick cement concrete of 1:2:3 proportion using coarse aggregate of 10 MSA and water proofing compound of approved make and polypropylene fibres @ 125 gm per bag of cement making groovr 3 to 4 mm wide & 10 mm deep in concrete, in pannels of 3m/4m or as per site condition & filling the joints with poly sulphide sealant after curing including providing holler with drip moulds at the junction and finishing the concrete surface with neat cement slurry, as directed and ponding the surface as directed etc.complete ; covering 10 years guarantee against leakproofness on court Fee stamp paper of Rs 100/- Second Floor |
| 35 | Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. First Floor |
| 36 | Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Second Floor |
| 37 | Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. Upto Ground Floor |
| 38 | Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. First Floor |
| 39 | Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. Second Floor |
| 40 | Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete ) |
| 41 | Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) |
| 42 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. |
| 43 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Upto Ground Floor |
| 44 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete First Floor |
| 45 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Second Floor |
| 46 | Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. Upto Ground Floor |
| 47 | Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. First Floor |
| 48 | Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. Second Floor |
| 49 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Upto Ground Floor |
| 50 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. First Floor |
| 51 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Second Floor |
| 52 | Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete. Upto Ground Floor |
| 53 | Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete. First Floor |
| 54 | Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete. Second Floor |
| 55 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Upto Ground Floor |
| 56 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. First Floor |
| 57 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Upto Ground Floor |
| 58 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. First Floor |
| 59 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Second Floor |
| 60 | Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 mm with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7 Kilograms/M2 and minimum pull out strength of 100 Kilograms.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Upto Ground Floor |
| 61 | Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 mm with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7 Kilograms/M2 and minimum pull out strength of 100 Kilograms.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. First Floor |
| 62 | Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 mm with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7 Kilograms/M2 and minimum pull out strength of 100 Kilograms.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Second Floor |
| 63 | Providing and applying impression 24 carrat Luxury paint of approved make & approved brand Emulsion paint to interior walls and ceilings of approved quality, colour and shade to new surface in two coats, including sub surface prparation by Acrylic putty and Acrylic primer coats including scaffolding, preparing the surface. etc. complete (Low VOC). Upto Ground Floor |
| 64 | Providing and applying impression 24 carrat Luxury paint of approved make & approved brand Emulsion paint to interior walls and ceilings of approved quality, colour and shade to new surface in two coats, including sub surface prparation by Acrylic putty and Acrylic primer coats including scaffolding, preparing the surface. etc. complete (Low VOC). First Floor |
| 65 | Providing and applying impression 24 carrat Luxury paint of approved make & approved brand Emulsion paint to interior walls and ceilings of approved quality, colour and shade to new surface in two coats, including sub surface prparation by Acrylic putty and Acrylic primer coats including scaffolding, preparing the surface. etc. complete (Low VOC). Second Floor |
| 66 | Providing and laying vitrified stone effect finish tiles having size 590 to 605 mm x 590 to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete Upto Ground Floor |
| 67 | Providing and laying vitrified stone effect finish tiles having size 590 to 605 mm x 590 to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete First Floor |
| 68 | Providing and laying vitrified stone effect finish tiles having size 590 to 605 mm x 590 to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete Second Floor |
| 69 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete Upto Ground Floor |
| 70 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete First Floor |
| 71 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete Second Floor |
| 72 | Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Upto Ground Floor |
| 73 | Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. First Floor |
| 74 | Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Second Floor |
| 75 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Upto Ground Floor |
| 76 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. First Floor |
| 77 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Second Floor |
| 78 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Upto Ground Floor |
| 79 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. First Floor |
| 80 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Second Floor |
| 81 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. Upto Ground Floor |
| 82 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. First Floor |
| 83 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. Second Floor |
| 84 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Upto Ground Floor |
| 85 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete First Floor |
| 86 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Second Floor |
| 87 | Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete Upto Ground Floor |
| 88 | Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete First Floor |
| 89 | Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete Second Floor |
| 90 | Providing and fixing Country teak wood Four leaf paneled shutters, 35 mm thick style and rail and 25 mm thick panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete Upto Ground Floor |
| 91 | Providing and fixing Country teak wood Four leaf paneled shutters, 35 mm thick style and rail and 25 mm thick panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete First Floor |
| 92 | Providing and fixing Country teak wood Four leaf paneled shutters, 35 mm thick style and rail and 25 mm thick panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete Second Floor |
| 93 | Providing and fixing of factory made uPVC Sliding window & door (White Colour) 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm. Upto Ground Floor |
| 94 | Providing and fixing of factory made uPVC Sliding window & door (White Colour) 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm. First Floor |
| 95 | Providing and fixing of factory made uPVC Sliding window & door (White Colour) 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm. Second Floor |
| 96 | Solid Core Flush door Single leafProviding and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter Upto Ground Floor |
| 97 | Solid Core Flush door Single leafProviding and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter First Floor |
| 98 | Solid Core Flush door Single leafProviding and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter Second Floor |
| 99 | Providing and fixing of factory made uPVC Louver window (White Colour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with 1.5 mm thick G. I. Section. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 mm Frosted Annealed glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge.uPVC Window and Door Profiles are warranted for a period of ten (10) years against non- uniform discoloration,wrapping and rotting under general use.a.Louver Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm. Upto Ground Floor |
| 100 | Providing and fixing of factory made uPVC Louver window (White Colour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with 1.5 mm thick G. I. Section. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 mm Frosted Annealed glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge.uPVC Window and Door Profiles are warranted for a period of ten (10) years against non- uniform discoloration,wrapping and rotting under general use.a.Louver Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm. First Floor |
| 101 | Providing and fixing of factory made uPVC Louver window (White Colour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with 1.5 mm thick G. I. Section. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 mm Frosted Annealed glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge.uPVC Window and Door Profiles are warranted for a period of ten (10) years against non- uniform discoloration,wrapping and rotting under general use.a.Louver Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm. Second Floor |
| 102 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Upto Ground Floor |
| 103 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. First Floor |
| 104 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Second Floor |
| 105 | Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) Upto Ground Floor |
| 106 | Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) First Floor |
| 107 | Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) Upto Ground Floor |
| 108 | Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) First Floor |
| 109 | Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) Second Floor |
| 110 | Providing and fixing 10 cm PVC nahani trap with grating etc. complete.Upto Ground Floor |
| 111 | Providing and fixing 10 cm PVC nahani trap with grating etc. complete.First Floor |
| 112 | Providing and fixing 10 cm PVC nahani trap with grating etc.complete.Second Floor |
| 113 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete.Upto Ground Floor |
| 114 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete.First Floor |
| 115 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Second Floor |
| 116 | Providing and fixing C.P. a 2-Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.Upto Ground Floor |
| 117 | Providing and fixing C.P. a 2-Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.First Floor |
| 118 | Providing and fixing C.P. a 2-Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Second Floor |
| 119 | Providing , constructing and fixing 450 mm dia. Inspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 mm and height of 388 mm with 160 or 200 mm main inlet (s) outlet and 110 and / or 160 mm branch inlets, with 450 mm dia. Ultra shaft pipe of HDPE material having height of 460 mm, having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete.Upto Ground Floor |
| 120 | Providing , constructing and fixing 600 mm dia. Inspection chamber made up of Polypropylene / polyethylene material Having 315 mm diameter inlet(s)/outlets and with eccentric reducers as per requirement to connect 160 mm and 200 mm pipes having thickness of 5 mm and 600 mm in height, with inbuilt shaft achieve the invert depth as per site condition of wall thickness of 5 mm having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc.complete.Upto Ground Floor |
| 121 | Providing and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall. Upto Ground Floor |
| 122 | Providing and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall. First Floor |
| 123 | Providing and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall.Second Floor |
| 124 | Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall. Upto Ground Floor |
| 125 | Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall. First Floor |
| 126 | Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete.Upto Ground Floor |
| 127 | Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. First Floor |
| 128 | Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. Second Floor |
| 129 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Upto Ground Floor |
| 130 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete First Floor |
| 131 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Second Floor |
| 132 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Upto Ground Floor |
| 133 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. First Floor |
| 134 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Second Floor |
| 135 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Upto Ground Floor |
| 136 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. First Floor |
| 137 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Second Floor |
| 138 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Upto Ground Floor |
| 139 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. First Floor |
| 140 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Second Floor |
| 141 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.Upto Ground Floor |
| 142 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. First Floor |
| 143 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc.complete. Second Floor |
| 144 | Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete. Upto Ground Floor |
| 145 | Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete. First Floor |
| 146 | Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete. Second Floor |
| 147 | Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.Upto Ground Floor |
| 148 | Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.First Floor |
| 149 | Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. Second Floor |
| 150 | Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete.Upto Ground Floor |
| 151 | Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete. First Floor |
| 152 | Providing and laying in trenches 50 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 5.17 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Upto Ground Floor |
| 153 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.Upto Ground Floor |
| 154 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. First Floor |
| 155 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Second Floor |
| 156 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.Upto Ground Floor |
| 157 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. First Floor |
| 158 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Second Floor |
| 159 | Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 mx 0.60 m )Upto Ground Floor |
| 160 | Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m ) First Floor |
| 161 | Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m ) Second Floor |
| 162 | Providing and fixing white wash basin with half pedestal of size 515mmX615mmX460mm including pillar cock auto-closing system CP angular stop cock long thread of approved make continental including S.S. bottle trap of necessary pipe connection upto the outside face of the wall.Upto Ground Floor |
| 163 | Providing and fixing white wash basin with half pedestal of size 515mmX615mmX460mm including pillar cock auto-closing system CP angular stop cock long thread of approved make continental including S.S. bottle trap of necessary pipe connection upto the outside face of the wall First Floor |
| 164 | Providing and fixing white wash basin with half pedestal of size 515mmX615mmX460mm including pillar cock auto-closing system CP angular stop cock long thread of approved make continental including S.S. bottle trap of necessary pipe connection upto the outside face of the wall Second Floor |
| 165 | Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.Upto Ground Floor |
| 166 | Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.First Floor |
| 167 | Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.Second Floor |
| 168 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc.complete.Upto Ground Floor |
| 169 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.First Floor |
| 170 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc.complete. Second Floor |
| 171 | Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters.Second Floor |
| 172 | Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester.Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67%Water absorption (as per ASTM):-0.30% Flammability as per ASTMTensile strength:-115 MPASpecific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mmOutlet pipe size rigid PVC:-80mmGas outlet rigid PVC with Valve: 20mmBacteria immobilization PVC mattes (on all partition)With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below f) Up to 80 user size (2.7mx1.5mx1m), Capacity of Biodigester:-4000 liters, Area of top, bottom and side walls: - 16.50 sq.m, Area of partition walls: 4.50sq.m, Total weight of FRP: - 202.50 Kilogram, Bacteria inoculums quantity: - 1400 liters, Minimum thickness of side walls / top and bottom: 6mm, One Number of inside partitions: - 4, Minimumthickness of partition wall: 3mm.Upto Ground Floor |
| 173 | RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.Upto Ground Floor |
| 174 | Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600MM (H) X 600MM (D) and 32MMDIA. and thickness mm of the approved brand and make. 27c) Straight grab bar (2 NOS)Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make.Upto Ground Floor |
| 175 | Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600MM (H) X 600MM (D) and 32MMDIA. and thickness mm of the approved brand and make. 27c) Straight grab bar (2 NOS)Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make. First Floor |
| 176 | Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600MM (H) X 600MM (D) and 32MMDIA. and thickness mm of the approved brand and make. 27c) Straight grab bar (2 NOS)Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make. Second Floor |
| 177 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone Cladding of 25 mm thickness to Concret or Plaster surfaces, wall , soffit, Column, Beam and top of chajja of approved quality, vein & colour as per drawing. Fixing Pink / Yellow Bansi Pahadpur Sand Stone cladding by Hilti anchor bolt over on level surface, Including cutting, dressing, machine / hand polish to surface, embossing, grooving, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead, lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 178 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone Cladding of 25 mm thickness to Concret or Plaster surfaces, wall , soffit, Column, Beam and top of chajja of approved quality, vein & colour as per drawing. Fixing Pink / Yellow Bansi Pahadpur Sand Stone cladding by Hilti anchor bolt over on level surface, Including cutting, dressing, machine / hand polish to surface, embossing, grooving, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead, lift and as per Engineer Incharge etc.. complete. First Floor |
| 179 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone Cladding of 50 mm thickness to Concrete or Plaster surfaces, wall, Column and Beam of approved quality, vein & colour as per drawing. Fixing Pink / Yellow Bansi Pahadpur Sand Stone cladding by Hilti anchor bolt over on level surface, Including cutting, dressing, machine / hand polish to surface, embossing, Machine carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead, lift and as per Engineer Incharge etc.. complete. First Floor |
| 180 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone Cladding of 75mm thickness to Concret or Plaster surfaces, wall, Column and Beam of approved quality, vein & colour as per drawing. Fixing Pink / Yellow Bansi Pahadpur Sand Stone cladding by Hilti anchor bolt over on level surface, Including cutting, dressing, machine / hand polish to surface, embossing, Machine carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead lift and as per Engineer Incharge etc.. complete. First Floor |
| 181 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for cladding to side of Circular columns of thickness Cladding Varies 175 mm. The cladding is to be installed over the RCC Column by Hilti Anchor bolt As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, statue of Gods etc., installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 182 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for cladding to side of Circular columns of thickness Cladding Varies 175 mm. The cladding is to be installed over the RCC Column by Hilti Anchor bolt As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, statue of Gods etc., installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. First Floor |
| 183 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for Solid columns of thickness 1030 to 510mm. The Solid Stone Column is to be installed over the RCC Column by Hilti Anchor bolt As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, statue of Gods etc., installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 184 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for Solid Beam of thickness 450mm and depth 600mm. The Solid Stone beam is to be installed over the Solid Stone Column by Hilti Anchor bolt As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, statue of Gods etc., installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 185 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for Solid Slab of thickness 250mm . The Solid Stone Slab is to be installed over the Solid Stone Columnm & Beam by Hilti Anchor bolt As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, statue of Gods etc., installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 186 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for Baluster for Railing /Balcony, of size 150 mm x 150 mm x 700 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 187 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for Baluster for Railing /Balcony, of size 150 mm x 150 mm x 700 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. First Floor |
| 188 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for Bottom Rail for stone railing of size 200 mm X 150 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 189 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for Bottom Rail for stone railing of size 200 mm X 150 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. First Floor |
| 190 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for Top Rail for stone railing of size 200 mm X 100 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 191 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for Top Rail for stone railing of size 200 mm X 100 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. First Floor |
| 192 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for newel post for Railing of staircase, of size 200 mm x 200 mm x 1200 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 193 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for newel post for Railing of staircase, of size 200 mm x 200 mm x 1200 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. First Floor |
| 194 | Providing, fixing and installation of Machine carved solid Pink / Yellow Bansi Pahadpur Sand Stone Arch. The finished unifrom thickness of stone cladding 150 mm to form a semicircular shape of approved quality vein & colour . The cladding is to be installed over the RCC column & Beam by Hilti Anchor bolt . As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), Fixing with brass pinning, cement slurry and making level surface by cement mortar 1:4 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints with white cement, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 195 | Providing, fixing and installation of Machine carved solid Pink / Yellow Bansi Pahadpur Sand Stone Arch. The finished unifrom thickness of stone cladding 150 mm to form a semicircular shape of approved quality vein & colour . The cladding is to be installed over the RCC column & Beam by Hilti Anchor bolt . As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), Fixing with brass pinning, cement slurry and making level surface by cement mortar 1:4 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints with white cement, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. First Floor |
| 196 | Providing, fixing and installation of Machine carved solid Pink / Yellow Bansi Pahadpur Sand Stone Jali. The finished unifrom thickness of stone Jali 75mm to form a semicircular shape of approved quality vein & colour . The cladding is to be installed over the RCC column & Beam by Hilti Anchor bolt . As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), Fixing with brass pinning, cement slurry and making level surface by cement mortar 1:4 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints with white cement, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 197 | Providing, fixing and installation of Machine carved solid Pink / Yellow Bansi Pahadpur Sand Stone Jali. The finished unifrom thickness of stone Jali 75mm to form a semicircular shape of approved quality vein & colour . The cladding is to be installed over the RCC column & Beam by Hilti Anchor bolt . As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), Fixing with brass pinning, cement slurry and making level surface by cement mortar 1:4 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints with white cement, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. First Floor |
| 198 | Providing, fixing and installation of Pink / Yellow Bansi Pahadpur Sand Stone moulding to outer side of Slab of approved quality vein & colour for moulding, the moulding thickness at bottom is 300 mm and height 400 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 199 | Providing, fixing and installation of Pink / Yellow Bansi Pahadpur Sand Stone moulding to outer side of Slab of approved quality vein & colour for moulding, the moulding thickness at bottom is 300 mm and height 400 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. First Floor |
| 200 | Providing, fixing and installation of Pink / Yellow Bansi Pahadpur Sand Stone moulding to outer side of Slab of approved quality vein & colour for moulding, the moulding thickness at bottom is 250 mm and height 350 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 201 | Providing, fixing and installation of Pink / Yellow Bansi Pahadpur Sand Stone moulding to outer side of Slab of approved quality vein & colour for moulding, the moulding thickness at bottom is 250 mm and height 350 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. First Floor |
| 202 | Providing, fixing and installation of Pink / Yellow Bansi Pahadpur Sand Stone moulding to outer side of Slab of approved quality vein & colour for moulding, the moulding thickness at bottom is 230 mm and height 300 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 203 | Providing, fixing and installation of Pink / Yellow Bansi Pahadpur Sand Stone moulding to outer side of Slab of approved quality vein & colour for moulding, the moulding thickness at bottom is 230 mm and height 300 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. First Floor |
| 204 | Providing, fixing and installation of Pink / Yellow Bansi Pahadpur Sand Stone moulding to outer side of Slab of approved quality vein & colour for moulding, the moulding thickness at bottom is 300 mm and at top 100 mm for height 600 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 205 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone Ceiling of 40mm thickness to bottom of R.C.C slab (slab soffit @ 3 to 6m height) of approved quality, vein & colour as per drawing. Fixing Sand Stone by Hilti anchor bolt over on level surface, Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 206 | Providing, fixing and installation of Pink / Yellow Bansi Pahadpur Sand Stone paraet wall of approved quality vein & colour . The parapet wall is with vertival post of size 360 mm X 360 mm X 600 mm @ 3 m center to center and 250 mm thick stone plate of height 600 mm in Sand Stone As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:4 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. First Floor |
| 207 | Providing and Fixing solidPink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for Flooring 25mm thick as per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 208 | Providing, fixing and Installation of carved Pink / Yellow Bansi Pahadpur Sand Stone Pyramid Cladding 350mm thickness of Solid stone .As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete First Floor |
| 209 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone Cladding of 600 mm thick of approved quality vein & colour for \\"Shikhar\\", on RCC wall .The shape of cladding stone should be as per profile of Shikhar as shown in detailed drawing. The top surface of cladding should be carved & moulded as shown in drawing. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:4 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete . First Floor |
| 210 | Providing and fixing Pink / Yellow Bansi Pahadpur Sand Stone Mandap with 4 nos of Column of Size 390mm dia and 1.76m height, Mandap Slab 6.14 m length, Width-2.86 m and Height-290 mm & Shikhar L-4.66m , W-1.26 & D-0.76 of approved quality vein & colour on RCC Slab .The shape of cladding stone should be as per profile of Shikhar as shown in detailed drawing. The top surface of cladding should be carved & moulded as shown in drawing. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:4 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. First Floor |
| 211 | Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete.Upto Ground Floor |
| 212 | Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete. First Floor |
| 213 | Providing and Fixing solid Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for Kalash, height of Kalash is 2.62 m and base is 1.3 m x 1.3 m the kalash is projcted adjacent to shikhar as per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. First Floor |
| 214 | Providing and Fixing solid Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for Kalash, height of Kalash is 0.86 m and base is 0.84 m x 0.84 m the kalash is projcted adjacent to shikhar as per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. First Floor |
| 215 | Providing and Fixing solid Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for Statue, height of Statue is 1 m and base is 0.6 m x 0.6 m the kalash is projcted adjacent to shikhar as per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. First Floor |
| 216 | Providing and Fixing solid Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for Window Bracket including Bottom moulding 2.49 x 0.135x 0.15, Top Moulding 2.49 x 0.15x 0.15, Top elevation 1 x 0.3 x 0.15 & 2 Column size 0.15 x 0.15 x1.5 as per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 217 | Providing and Fixing solid Pink / Yellow Bansi Pahadpur Sand Stone of approved quality vein & colour for Window Bracket including Bottom moulding 2.49 x 0.135x 0.15, Top Moulding 2.49 x 0.15x 0.15, Top elevation 1 x 0.3 x 0.15 & 2 Column size 0.15 x 0.15 x1.5 as per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, approved water proofing treatment, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. First Floor |
| 218 | Providing and laying Ambaji Marble flooring of thickness 25 mm of approved quality vein & colour, on bed of 1:6 C.M. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, mirror polish to surface, embossing, carving, grooving, installation and grinding, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement float, filling joints with neat cement slurry, curing, polishing and cleaning transportation of all materials up to site of work, filling of joints, cleaning, including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 219 | Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mm Bacteria immobilization PVC mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below l) Up to 500 user size (6mx2.0mx1.6m), Capacity of Biodigester:-20000 liters, Area of top, bottom and side walls: - 50.72 sq.m, Area of partition walls: 13.36sq.m, Total weight of FRP: - 917.86 Kilogram, Bacteria inoculums quantity: - 7000 liters, Minimum thickness of side walls / top and bottom: 9 mm, One Number of inside partitions: - 4,Minimum thickness of partition wall: 4mm. Upto Ground Floor |
| 220 | Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.Upto Ground Floor |
| 221 | Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 5.0 to 9.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary) Upto Ground Floor |
| 222 | Providing and laying Ambaji Marble flooring of thickness 25 mm of approved quality vein & colour, including inlay work in semi precious stones @ 850 gms per sq.mtr. (LAPIS LAZULI, GREEN PAYZER, EMERALD GREEN, MALACHITE, TIGER EYE, MOP (MOTHER PEARL) ONYX, etc) of approved quality vein & colour on bed of 1:6 C.M. including. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, mirror polish to surface, embossing, carving, grooving, installation and grinding, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement float, filling joints with neat cement slurry, curing, polishing and cleaning transportation of all materials up to site of work, filling of joints, cleaning, including all material, labour, lead , lift and as per Engineer Incharge etc.. complete. Upto Ground Floor |
| 223 | Providing Stampping polymer modified wall Plastering material to vertical surfaces, Wall plastering is premixed with Water and Bonding agents ( 2.5 kg mortor with ratio 1:5 mixed with 1kg polymer material) on the wall over Rough Plastered Wall in thickness of Approx. 10-12mm finalized with prescribed colour and stamping pattern as directed by Engineer Incharge. Providing and applying Acrylic polymer Sealer coat to the stamped area including removing Acid and Dust with water jet if required, after curing applying first coat of sealer using either spray pump, brush or roller @ 80 sqft per Ltr. After complete drying of first coat. Applying second coat @ 80 sq ft per Ltr , Allowing to dry for at least 4 hours etc. Including labour, fixing material, scaffolding etc. Job complete.Upto Ground Floor |
| 224 | Providing Stampping polymer modified wall Plastering material to vertical surfaces, Wall plastering is premixed with Water and Bonding agents ( 2.5 kg mortor with ratio 1:5 mixed with 1kg polymer material) on the wall over Rough Plastered Wall in thickness of Approx. 10-12mm finalized with prescribed colour and stamping pattern as directed by Engineer Incharge. Providing and applying Acrylic polymer Sealer coat to the stamped area including removing Acid and Dust with water jet if required, after curing applying first coat of sealer using either spray pump, brush or roller @ 80 sqft per Ltr. After complete drying of first coat. Applying second coat @ 80 sq ft per Ltr , Allowing to dry for at least 4 hours etc. Including labour, fixing material, scaffolding etc. Job complete First Floor |
| 225 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Upto Ground Floor |
| 226 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor |
| 227 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Upto Ground Floor |
| 228 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor |
| 229 | Providing, fixing and installation of decorative type Gate in cast iron and MS pipes of Required height consist of MS pipes, CI flat leafs etc as per detailed drawing and specification provided by architect & engineer in charge, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. |
| 230 | Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils. |
| 231 | Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 232 | Providing and laying weep holes of 100 mm diameter PVC pipes as per drawing for abutment returns, return walls etc. Complete. |
| 233 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 234 | Providing cast in situ / ready mix M20 grade cement concrete for head walls of CD work / retaining walls etc. including necessary form work, compaction, finishing and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) with SCADA |
| 235 | Providing and laying in situ / ready mix M-20 controlled cement concrete of trap/ granite/ quartzite/ gneiss metal for RCC work in solid/ deck slab etc. including ramming, vibrating, curing, formwork, centering and finishing in cement plaster excluding reinforcement etc. complete. (with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer and fine agreegates of required specifications ( VSI sand finely washed etc )i) Height up to 5 m, normal rate.ii) Height 5 to 7.50 m, add 5 percent extra over basic rate.iii) Height 7.50 to 10 m, 7.50 percent extra.iv) Over 10 m Height, add 10 percent extra for every 2.50m rise. |
| 236 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 237 | Providing cast in situ / ready mix M25 grade cement concrete for head walls of CD work / retaining walls etc. including necessary form work, compaction, finishing and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) with SCADA. |
| 238 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 239 | Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) |
| 240 | Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (Heat Reflective Paint). |
| 241 | Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram/Smt. |
| 242 | Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc.complete. |
| 243 | Providing and fixing of factory made uPVC Sliding window & door (White Colour) 2 Track 2 / 4 Sash (Big Series) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAll corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. 2 Track 2 / 4 Sash (Big Series) window frame of size 67 x 54 mm & Sash of size 64 x 47 mm. |
| 244 | Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. |
| 245 | Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader / Paver on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- By Mix in Place Method and Grading - I Material. |
| 246 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means -Grading I (Using Screening Type B (11.2 mm) Aggregate) |
| 247 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 mm) Aggregate) |
| 248 | Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 mm thickness of having a strength of 400 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. (using 100% crushed sand) |
| 249 | Stamp Concrete of 100mm Thickness - Providing and Laying in-situ M30 Grade unreinforced plain cement stamp concrete of 100mm thickness pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate (natural sand / VSI grade finely washed crushed sand) Confirming to IS 383, as per mixed in a batching and mixing plant / non tilting mixer and weigh batcher as per approved mix design, admixtures, transporting to site in nagpur city with lead upto 20KM (on Inner Ring Road from Avasti nagar to wadi), spreading, laying with approved make pover, compacted and finished in a continous operation, finishing to lines and grades Also Providing, Placing and applying stamp powder which is light fast UV resistant pigment with appropriate chemical compounds of desired colour on base concrete after excess bleed water has evaporated using dry shake method @5kg per sqm. Including texturing, and covering with plastic sheet (min 200 micron thickness) and also applying two coats of UV-stable,30 % solids clear sealer @ 150 to 250 gms per sqm using surface roller and protecting from falling dust,dirt and curring by curring compound / by providing cement vata in cement Mortor 1:8 @ 0.6m x 0.6m center to center, admeasuring 80mm at bottom and 40mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-incharge or Landscape architect etc. complete. (prior approval of superinteding Engineer will be necessary ) |
| 250 | Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 251 | Yield Testing of borewells using90\\" 'V' Notch by air lift method for Half hours for successful borewell as per yielidng Borewell and installation. Yield testing of Borewell using 80\\"V'. |
| 252 | Driling of 150mm diameter Inwell vertical bore including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete |
| 253 | Providing casing pipe welded threaded joints medium class ERW Mild Steel block as per ISI 1239 specifications with socket and inserting in Tube well through over burden including transportation to site cutting threading & grouting the sand with cement slurry including in the cost of the coupling and plugs of 4.8mm thick etc. complete 150 mm dia perforated. providing casing pipe welded threaded joints.150 mm |
| 254 | Providing and laying in trenches 80 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 10.15 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 255 | Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 20cms.( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38a). |
| 256 | Supplying on site well decomposed Farm Yard Manure for excavation area of depth of 20 cms.( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38b). |
| 257 | Providing on site well established (free from weeds /diesease etc.) ready to fix lawn turf in slabs/ rolls of required variety as directed .(As per P&G DSR 2022-23 Items of garden work,Sr No.14, item no 2) |
| 258 | Providing on site required variety of Shrubs (free from weeds /diesease etc.) 30 cms. apart c/c.Name:-Murraya(Kamini);Bag Size 7'' x 8\\" (plants list) 1(a) serial no 15. |
| 259 | Providing on site required variety of HedgesWell Developed, Healthy Foliage / Half Bloom Stage , Free from Pest and Diseases. apart c/c.Name:-Bougavillae Thema ;Bag Size 8'' x 10\\"(plants list) 7(b) serial no 10. |
| 260 | Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 20 cms.(As per P&G DSR 2022- 23 Items of garden work,Sr No.5) |
| 261 | Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 20 cms. for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed/ ground cover. (1/10 of semiskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.23) |
| 262 | Maintainance of Newly Developed lawn(Instant Lawn) Area. For First 30 daysOnly (As per P&G DSR 2022-23 Items of garden work,Sr No.29) |
| 263 | Maintainance of Newly Developed ShrubsArea. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.31) |
| 264 | Supplying on site fresh Garden soil (i. e. 3 part soil ) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 1 x 1 x 1m ( consolidated thickness).Quantity of soil 0.653 cum x 800/cum = 522.40/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.45a). |
| 265 | Supplying on site fresh Garden soil (i. e. 3 part soil ) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 0.45 x 0.45 x 0.45m ( consolidated thickness).Quantity of soil 0.079 cum x 800/cum = 63.20/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.43a). |
| 266 | Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 1 x 1 x 1m. ( consolidated thickness).Quantity of FYM 0.203 cum x 950/cum = 19.85/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.45b). |
| 267 | Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 0.45 x 0.45 x 0.45m. ( consolidated thickness).Quantity of FYM 0.203 cum x 950/cum = 21.85/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.45b). |
| 268 | Providing on site Flowering Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and diseases Name:-ALLAMANDA ;Bag Size 10 x10'', ht 15- 30CM (plants list sr no1 ( b) , item no 2 Page no -16). |
| 269 | Providing on site Flowering Climbers and creepers Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and. disease Name:-Allamanda (allamanda cathertica) ;Bag Size 7 x 8'', ht 15- 30 CM (plants list sr no 3 , item no 2 Page no -19). |
| 270 | Providing on siteBalbous / Rhizomatous plants Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Lilium sp. ;Bag Size 7 x 8'', ht 30- 45 CM (plants list sr no 4 , item no 6 Page no -20). |
| 271 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Bahva (Amaltash);Bag Size 18 x18'', ht 8- 10'(plants list sr no 5C, item no 1 Page no -22) . |
| 272 | Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Arjuna ;Bag Size 18 x18'', ht 8- 10'(plants list sr no 6C, item no 3 Page no -24). |
| 273 | Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Deshi Badam ;Bag Size 18 x18'', ht 8- 10'(plants list sr no 6C, item no 4 Page no -24). |
| 274 | Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Drooping Ashok ;Bag Size 18 x18'', ht 8- 10'(plants list sr no 6C, item no 5 Page no -24). |
| 275 | Providing on site HEDGES Specification:- Well developed, healthy Foliage/ Half bloom stage, free from pest and diseases .Name:-Bougavillae Thema ;Bag Size 18 x18'', ht 60cm to 75 cm (plants list sr no 7d, item no 2 Page no -26). |
| 276 | Providing on site HEDGES Specification:- Well developed, healthy Foliage/ Half bloom stage, free from pest and diseases .Name:-Bougavillae Glabra;Bag Size 13 x13'', ht 60cm to 75 cm (plants list sr no 7d, item no 3 Page no -26). |
| 277 | Providing on site Ground Cover Specification:- Well developed, healthy, free from pest and diseases .Name:-Asparagus ;Bag Size 7 x8'', ht 10cm to 20 cm (plants list sr no 8, item no 3 Page no -26). |
| 278 | Providing on site Palms Specification:- Palm should be well Developed,Good Branching ,healthy Condition,appropriate Size in Polybag,undamaged... Apart c/c.Name:-Areca Palm ;Bag Size 18 x18'', ht 8- 10'(plants list sr no1,item no 11d). |
| 279 | Providing on site Palms Specification:- Palm should be well Developed,Good Branching ,healthy Condition,appropriate Size in Polybag,undamaged... Apart c/c.Name:-Fox tail palm;Bag Size 18 x18'', ht 8- 10'(plants list sr no3,item no 11d). |
| 280 | Providing and Supplying Cement Pot size 36 Inch x 18 inch x 18 Inch of good quality, Durable well finish on edge with good strength. |
| 281 | Excavation pit size 1.00 x1.00 x 1.00m for planting large flowering/ shady trees (plant height 2 to 4 mtr.)/ palm varieties of height (plant height 2 to 4 mtr.) inearth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 mtrs. (As per P&G DSR 2022-23 Items of garden work,Sr No.12) |
| 282 | Excavation pit size 0.45 x 0.45 x 0.45 m for planting earth, soil of all types, soft murum, including removing the excavated & unwantedmaterial up to a required distance of 50 mtrs. (As per P&G DSR 2022-23 Items of garden work,Sr No.10) |
| 283 | Filling fresh garden soil / silt & manure in excavated pit size area of 1.00 x 1.00 x 1.00m (1/10 of unskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.22) |
| 284 | Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species as directed etc. complete for required pit size 1.00 x 1.00 x 1.00m.(1/10 of semiskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.27) |
| 285 | Maintainance of Newly Planted tree varities having height 2mtr. - 4mtr. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Srs No.35) |
| 286 | EI & LAN/WAN;Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 287 | EI & LAN/WAN; Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 288 | EI & LAN/WAN; Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 289 | EI & LAN/WAN; Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 290 | EI & LAN/WAN; Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 291 | EI & LAN/WAN; Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 292 | EI & LAN/WAN;Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 293 | EI & LAN/WAN;Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 294 | EI & LAN/WAN;Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 295 | EI & LAN/WAN;Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 296 | EI & LAN/WAN;Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 297 | EI & LAN/WAN;Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 298 | EI & LAN/WAN;Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 299 | EI & LAN/WAN;Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 300 | EI & LAN/WAN;Supplying and erecting mains with 4x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 301 | EI & LAN/WAN;Supplying and erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 302 | EI & LAN/WAN;Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 303 | EI & LAN/WAN;Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 304 | EI & LAN/WAN;Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 305 | EI & LAN/WAN;Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 306 | EI & LAN/WAN;Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 307 | EI & LAN/WAN;Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 308 | EI & LAN/WAN;Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 309 | EI & LAN/WAN;Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 310 | EI & LAN/WAN;Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 311 | EI & LAN/WAN;Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 312 | EI & LAN/WAN;Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW( Light111+Wall Fan 26=137) |
| 313 | EI & LAN/WAN;Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW (Celling Fan 15) |
| 314 | EI & LAN/WAN;Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW. (Exhaust + Tube+BH) |
| 315 | EI & LAN/WAN;Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 316 | EI & LAN/WAN;Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 317 | EI & LAN/WAN;Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW |
| 318 | EI & LAN/WAN;Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 319 | EI & LAN/WAN;Supplying and installing armoured single mode optical fibre cable with 6 fiber, core dia 50/125μm (OS1/OS2) 10/40 GBPS speed in provided underground HDPE pipe complete. |
| 320 | EI & LAN/WAN;Supplying and fixing 1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-D in position as per specification No. WG-COC/PC |
| 321 | EI & LAN/WAN;Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS |
| 322 | EI & LAN/WAN;Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL |
| 323 | EI & LAN/WAN;Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK |
| 324 | EI & LAN/WAN;Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 325 | EI & LAN/WAN;Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 326 | EI & LAN/WAN;Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 327 | EI & LAN/WAN;Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size. |
| 328 | EI & LAN/WAN;Supplying and erecting integrated LED flood light fitting Max. 50W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 5000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 3500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.(Warm White) |
| 329 | EI & LAN/WAN;Supplying and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 RPM with speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 Volts single phase, 50 cycles A.C. supply, with one meter of 3 core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation. |
| 330 | EI & LAN/WAN;Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 331 | EI & LAN/WAN;Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF (Without Remote) |
| 332 | EI & LAN/WAN;Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. |
| 333 | EI & LAN/WAN;Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. |
| 334 | EI & LAN/WAN;Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 335 | EI & LAN/WAN;Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC |
| 336 | EI & LAN/WAN;Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system. |
| 337 | EI & LAN/WAN;Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC |
| 338 | EI & LAN/WAN;Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC |
| 339 | EI & LAN/WAN;Supplying & erecting four pole ON LOAD change over switch, 415V, 315-320A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. |
| 340 | EI & LAN/WAN;Supplying and erecting switch disconnector fuse (SDF) 415V, 300-320A, with enclosure, four pole and neutral link AC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3 HRC - DIN type fuse switch, insulation voltage 1000 V, with rotary handle for ON / OFF operation (without HRC fuse) |
| 341 | EI & LAN/WAN;Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 342 | EI & LAN/WAN;Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 343 | EI & LAN/WAN;Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 344 | EI & LAN/WAN;Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 345 | EI & LAN/WAN;Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 346 | EI & LAN/WAN;Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB(Utility) |
| 347 | EI & LAN/WAN;Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 348 | EI & LAN/WAN;Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 349 | EI & LAN/WAN;Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 350 | EI & LAN/WAN;Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB |
| 351 | EI & LAN/WAN;Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 352 | EI & LAN/WAN;Supplying, fixing and commissioning 4 pole RCBO 63A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 353 | EI & LAN/WAN;Supplying & erecting HRC fuse cartridge 415V, 300A |
| 354 | EI & LAN/WAN;Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 200/300A |
| 355 | EI & LAN/WAN;Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. |
| 356 | EI & LAN/WAN;Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982 |
| 357 | EI & LAN/WAN;Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 358 | EI & LAN/WAN;Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard |
| 359 | EI & LAN/WAN;Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB |
| 360 | EI & LAN/WAN;Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 361 | EI & LAN/WAN;Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 362 | EI & LAN/WAN;Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs. |
| 363 | EI & LAN/WAN;Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. |
| 364 | EI & LAN/WAN;Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. |
| 365 | EI & LAN/WAN;Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc. |
| 366 | EI & LAN/WAN;Supplying, installation & marking of surge arrestor/ surge protection device at the sub main distribution board after the incoming breaker of type 2 tested for Imax 40 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD |
| 367 | EI & LAN/WAN;Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 368 | EI & LAN/WAN;Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 369 | EI & LAN/WAN;Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 370 | EI & LAN/WAN;Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 371 | EI & LAN/WAN;Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories. |
| 372 | EI & LAN/WAN;Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 373 | EI & LAN/WAN;Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 374 | EI & LAN/WAN;Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 375 | EI & LAN/WAN;Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. |
| 376 | EI & LAN/WAN;Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 377 | EI & LAN/WAN;Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. |
| 378 | EI & LAN/WAN;Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete. |
| 379 | EI & LAN/WAN;Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes) |
| 380 | EI & LAN/WAN;Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV |
| 381 | Fire fighting;Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 382 | Fire fighting;Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 383 | Fire fighting;Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 384 | Fire fighting;Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 385 | Fire fighting;Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 100 mm height comprising all required standard accessories. |
| 386 | Fire fighting;Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 387 | Fire fighting;Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 388 | Fire fighting; Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 389 | Fire fighting;Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850LPM at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 45kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP (Main Hydrant+Sprinkler+Standby) |
| 390 | Fire fighting;Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 110 to 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 11 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/JP |
| 391 | Fire fighting;Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP |
| 392 | Fire fighting;Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP |
| 393 | Fire fighting;Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specificationsthe capacity of electric motor driven pump are as followsa. Main fire pump(MFP) having capacity of 22kW 1no (1 working)b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. 4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch.5. TPN SPD 100kA Type 1 +2 tested.6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps.7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications.9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge.10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP = (1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECP Add Ons:-A-3)For main electric motor driven fire hydrant system pump of 45kW capacity & relevant capacity jockey pump add Rs 47686/-B-4)For main electric motor driven fire sprinkler system pump of 45kW capacity (1Working) & relevant capacity jockey pumps (1working+1standby, alternate run per start in auto mode, add Rs 200564/-C-4)For standby main electric driven fire hydrant/sprinkler system pump of 45kW capacity, add Rs 37184/- D)For addition of standby main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode) & jockey fire pumps (1working+1standby, alternate run per start in auto mode) , add Rs 68381/-The control for diesel engine comprises of automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumpsE-1)for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) , add Rs 17994Total:- FCP + A-3 + B-4 + C-4 + D + E-1 = 182320+47686+200564+37184+68381+17994 =554129+5% = 5,81,835.45 |
| 394 | Fire fighting;Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP |
| 395 | Fire fighting;Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP |
| 396 | Fire fighting;Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP |
| 397 | Fire fighting;Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP |
| 398 | Fire fighting;Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP |
| 399 | Fire fighting;Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP |
| 400 | Fire fighting;Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV |
| 401 | Fire fighting;Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, screen of SS end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 402 | Fire fighting;Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV |
| 403 | Fire fighting;Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 404 | Fire fighting;Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 405 | Fire fighting;Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 406 | Fire fighting;Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 407 | Fire fighting;Supplying and erecting 50 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 408 | Fire fighting;Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 409 | Fire fighting;Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV |
| 410 | Fire fighting;Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL |
| 411 | Fire fighting;Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ |
| 412 | Fire fighting;Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FMC |
| 413 | Fire fighting;Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT |
| 414 | Fire fighting;Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV |
| 415 | Fire fighting;Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG |
| 416 | Fire fighting;Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS |
| 417 | Fire fighting;Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8\\"x6\\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 418 | Fire fighting;Supplying, erecting testing and commissioning optical type smoke detector on suitable back box with necessary connections complete as per specification no. FF-FAS/SD |
| 419 | Fire fighting;Supplying, erecting, testing and commissioning manual call point (Pill box) with break glass push button and flip abort switch or agent release switch in metal enclosure complete as per specification no. FF-FAAS/MCP |
| 420 | Fire fighting;Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR |
| 421 | Fire fighting;Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU |
| 422 | Fire fighting;Supplying, installing, testing and commissioning of 4 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories , 16x2 Character LCD Display, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC, 0 - 49 Deg C, 93 ± 2 Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF-FAAS/FACP ( Add 50% for Additional 2 zone Rs 8919.50/- ; Base Price Rs 17839 + 8919.50 = 26758/- Add 5% Total - 28096.45 |
| 423 | Fire fighting;Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR |
| 424 | Fire fighting;Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC |
| 425 | Fire fighting;Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC |
| 426 | Fire fighting;Supplying, erecting, testing and commissioning of 0.5 sq. mm speaker wire complete. |
| 427 | Fire fighting;Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½\\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR. |
| 428 | Fire fighting;Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. |
| 429 | Fire fighting;Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 430 | Fire fighting;Supplying and erecting ABC powder type fire extinguisheras per IS : 13849 /15683 of 6 kg capacity with necessaryclamp for erection on wall. |
| 431 | Fire fighting;Providing and Erecting of SIP4G-16 Smart IoT Gateway for Fire Fighting Monitering System.GSM-based IoT module for monitoring and controlling fire safety and building systems with RS-485 MODBUS and MQTT connectivity. Having 16 Digital Inputs, 4 (SPST) Relay Outputs,RS-485 MODBUS RTU Input (Upto 16)MQTT Protocol with JSON format, SMS (10), Email (5), Voice Call (10), Data interval: 60-3600 seconds, Inbuilt Memory and RTC, MQTT compatible (Ambeiiot, ThingsBoard), Real-time dashboards and analytics, Encrypted data transfer, Historical data logging and reporting, LEDs- 12 LED's (Buzzer & LED indications), 4G GSM/LTE with dual SIM slots for redundancy, PC Software Configuration, With One year Cloud Storage, Relay card contact rating- 5A@28VDC/230VAC (1 C/O), Antenna: up to −15 dBi, Humidity: 10–90% RH, Non-Condensing, 230VAC Power Supply and Operting Temp: 0–50°C. Including all required interface Relay Cards as per site requirtements. Including Installation and testing of all types of sensors as per requirements such as Underground tank water level sensors, Overhead tank water level sensors, Diesel Sensor, Low Battery sensor, etc. Including All type of Wiring C, Cables, Connectors and accessories, SIM Card with 1 year recharge, Cloud Storage, etc as per site or as directed by Executive Engineer in charge. Monitering System Should Comply as per Maharashtra Fire Prevention and Life Safety Measures Act, 2006, Amended in 2025. |
| 432 | Fire fighting;Supplying & installation auto glow/self Luminous Including inbuild Rechargable Battery (Viewing upto 15 mtr length) fire signages Fire Exit, Fire Hydrant,Hose Box, MCP, Hooter, Fire Alarm Control Panel & Fire Exinguisher signage Indicating the detail. With BS 5499 as per sample approved by incharge. Including Wiring and All accessories. |
| 433 | Fresh Air Plant & Kitchen exhaust;SITC of factory built Floor mounted double skin type Air Handling Units with thermal break profile made of 43 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.6 mm outside layer and 0.6 mm plane inside layer with polyurethene foam (PUF) insulation of density 32 kg/m3 factory injected between them by injection moulding machine, complete with blower section with blower DIDW backward curved centrifugal fan of 60 mm WC static pressure, 6 row deep cooling coil, section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type Pre filters having efficiency 90% down to 10 micron, belt drive package with TEFC drive motor suitable for 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, complete with mixing box, drain connections with drain valve, drain pan, thermometers and pressure gauge at the inlet and outlet of the coils, necessary vibration isolation arrangement etc, complete as per specifications of following capacities: 10000 CFM at 60 mm WC |
| 434 | Fresh Air Plant & Kitchen exhaust;Supply & Installation of Acoustic Insulation of ducts with Open Cell Nitrile rubber Insulation Material with density 140-160 kg/m3 10 mm thick |
| 435 | Fresh Air Plant & Kitchen exhaust;Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.(1.98 Sqm Each) |
| 436 | Fresh Air Plant & Kitchen exhaust;Supply, installation, testing and commissioning of anodised aluminium fresh air louvers with bird screen and volume control damper with lever mounting arrangement etc. as per specifications and drawings. |
| 437 | Fresh Air Plant & Kitchen exhaust;Supply, Installation, Testing & commissioning of Motorised Fire Dampers min 90 min rating with suitable modulating type actuator of the torque suitable to operate the damper. The actuator shall operate on 24V DC supply. of GI Construction, |
| 438 | Fresh Air Plant & Kitchen exhaust;Installation, testing and commissioning of Inline fans with motor complete in all respect & of following capacities. The casing of inline fans shall be acoustically lined & shall be selected for lower noise level. Fan motor shall have inbuilt speed controller.1600 CFM with 25mm ESP motor should comply with minimum IE3. |
| 439 | Fresh Air Plant & Kitchen exhaust;Supplying and fixing GSS Louvres with bird screen, adjustable damper. |
| 440 | Fresh Air Plant & Kitchen exhaust;Supplying and installing of coller damper of 304 grade Stainless Steel Sheet material for supply air grill of required size |
| 441 | Fresh Air Plant & Kitchen exhaust;Supplying and erecting 304 grade Stainless Steel (24 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 442 | Fresh Air Plant & Kitchen exhaust;Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 443 | Fresh Air Plant & Kitchen exhaust;Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 444 | Fresh Air Plant & Kitchen exhaust;Supplying and erecting GI sheet 1 mm (20 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 445 | DG Set;Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 446 | DG Set;Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 447 | DG Set;Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 448 | DG Set;Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 449 | DG Set;Supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 1 %, with performance class G2 and maximum fuel consumption 34.40 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 1.4/1.5 mm thickness MS Sheet, sound absorbing material to restrict sound level up to 75 dB(A) at 1.0 m, provided with first filling of oil, diesel not less than 300 Ltr etc. on provided M20 Grade CC Foundation, complying to CPCP IV norms with STD AMF panel complete. Approved by SE Office Nagpur Vid letter no.520 Dt.20/02/2024. |
| 450 | DG Set;Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 180 kVA up to 200 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. . (194306.70-10% = 174876.03) |
| 451 | DG Set;Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. |
| 452 | DG Set;Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). |
| 453 | PA & Display system;Supply, installation, testing and commissioning of Surface mount speaker with 6.5-inch LF driver with a coated paper cone and one 1-inch high-frequency soft dome driver. operating range of 65 Hz to 22 kHz (-10 dB) or better with a nominal beamwidth of 100° (H) x 50° (V) or better. Continuous Power Handling of 150W @ 16Ω (600W peak) or better. Nominal sensitivity of 90 dB (1 W/1 m) or better, and a maximum SPL of 112 dB continuous and 118 dB peak or better. The integrated transformer shall offer selectable power taps of 70V: 60W, 30W, 15W, 7.5W, 3W and 100V: 60W, 30W, 15W, 6W. The device shall include a three-stage self-resetting protection system. The speaker shall be mountable via a supplied bracket and shall carry an IP64 environmental rating. Included accessories shall consist of a mounting bracket and safety cable. the speaker should have 5-year warranty. |
| 454 | PA & Display;Supply, installation, testing and commissioning of The loudspeaker system full-range, high-output, long-throw horn design incorporating a 6.5-inch (165 mm) weather-resistant cone driver and a 1-inch (25 mm) compression driver, both mounted within a durable ABS horn assembly with a weather-resistant rear cover and cable gland. The system shall meet IP66 rating for environmental protection, and the enclosure shall be constructed from high-impact ABS to ensure long-term reliability. A heavy-gauge corrosion-resistant U-bracket shall be provided, allowing rotation of more than 180 degrees for flexible aiming. The operating frequency range shall be 150 Hz to 20 kHz or better, and the unit shall include Transformer Tapping of 70 V: 62 W, 32 W, 16 W, 8 W, 4 W and 100 V: 62 W, 32 W, 16 W, 8 W. The sensitivity of speaker at 1 meter shall be 106 dB or better, with a nominal dispersion of 95° H X 125° V. The loudspeaker shall be supplied with an adjustable U-bracket for mounting. the speaker should have 5-year warranty. |
| 455 | PA & Display system;Supply, installation, testing and commissioning of a 2400W 4-channel amplified loudspeaker controller.The amplified loudspeaker controller shall operate in both Lo-Z (low impedance) and Hi-Z (70V/100V high impedance) configurations, with the capability to support hybrid systems. Device shall feature a built-in DSP with comprehensive audio processing, including 2048-tap FIR filters, dynamic EQ, raised-cosine EQ, peak limiters, program limiters, and thermal limiters with side-chain functionality. The controller shall be able to drive both low impedance loads (2.7/4/8/16 Ohm) and 70V/100V distributed lines, selectable per channel. Ports: 2 1000Base-T ports,Dante, AES67 and AVB,Frequency Response:- +/-0.5 dB (20 - 20000 Hz, 8 ohm,Dynamic range :-117 db.GPIO Ports - 4 logic/voltage control pins. The Amplifier should have 5-year warranty. |
| 456 | PA & Display system;Supply, installation, testing and commissioning of Stereo pre-amplifier and mixer featuring two independent stereo volume zones. The device shall provide two stereo zone outputs with a signal-to-noise ratio greater than 97 dB or better and crosstalk greater than 70 dB or better. The system shall include two balanced microphone inputs with individual level control and 48-volt phantom power, along with four unbalanced line-level inputs. The unit shall support VOX mute, an emergency input, a priority contact input, three priority levels, tone control, and music level control. The frequency response shall be 20 Hz to 25 kHz or better, with total harmonic distortion less than 0.2% or better. The mixer shall be suitable for both low-impedance and 100 V applications and shall not include selectable input or output dynamics, RS-232 control, SPDIF input or output, VCA control, or noise gating on microphone inputs. The Device should have 5-year warranty. |
| 457 | PA & Display system;Supply, installation, testing and commissioning of a multi-source music player equipped with DAB/DAB+ radio, FM RDS tuner, CD playback, USB, SD-card and Bluetooth audio streaming. The device shall support USB and SD-card storage up to 32 GB with a capacity of up to 9,999 audio files in MP3 or WMA formats. Bluetooth functionality shall support A2DP, AVRCP and SPP profiles. The system shall include one optical and one coaxial digital audio output, as well as RS-232 control capability. Unbalanced audio outputs shall be provided via two RCA connectors and a combined RCA output. An IR remote control shall be included. The music player shall be suitable for use in both low-impedance and 100 V audio systems. The Device should have 5-year warranty. |
| 458 | PA & Display system;Supply, installation, testing and commissioning of Wireless handheld microphone set with Frequency Response: 50 to 15,000 Hz or better, Total Harmonic Distortion Ref. ±33 kHz deviation with 1 kHz tone 0.5%, typical or better, Dynamic Range: 100 dB or better. receiver should have Sensitivity of -105 dBm or better. It should have a minimum 91 m (300 ft) transmission range. Image Rejection >50 dB or better. Output Impedance 200 Ω or better, Audio Output Level –27 dBV (into 100 kΩ load). Transmitter Audio Input Level: @ 0dB: -20 dBV maximum @ -10dB: -10 dBV maximum. Gain Adjustment Range: 10 dB or better.RF Transmitter Output: 10 mW or better. Power Requirements: 2 LR6 AA batteries, 1.5 V. Battery Life: up to 14 hours. |
| 459 | PA & Display system;SuppLy and laying of High-conductivity copper speaker Cable, 2.5 SQ mm stranded tinned copper conductor, PVC insulation, twisted pair PVC jacket. |
| 460 | PA & Display system;Supply, Installation, Testing, and Commissioning of Outdoor type LED Screen 18 Feet (W) x 10 feet (H) Dimensions (w x h) (mm) -320 x 160mmPixel pitch - 1.8 mm Indoor LED Configuration & Make- SMD 2121 Resolution (w x h) - 128 x 64Pixel Density -160000 dots/m, Pixel Configuration- (1R,1G, 1B)Brightness Control - 256 levels.Viewing Angle - 140/120 DegreeMinimum Viewing Distance - >2.5m Brightness Control - 256 LevelsRefresh Frequency - 1920/3840HzDriving Mode - constant current drivingScan method - 1/32 Scanning, Input power frequency -50 or 60HzInput Voltage - 140 ~ 260 VoltPower Consumption Maximum - <488 W/mPower Consumption Average - 163 W/mBlind spot rate - <1/10000 hoursCabinet Services method - Front Rear ServiceLifetime at 50% brightness - 100000 hoursInternational Protection - IP 43Operation Temperature - -20~ + 60 C+ 10%MTBF - >10,000hoursWorking humidity - 10%-90%RHSignal input format - Composite, S-Video, VGA, DVI, YPbPr, HDMI, SDI/USB. |
| 461 | PA & Display system;Providing and Erecting All-in-one LED video processor and controller Inputs: HDMI 1.3, Single Link DVI, 3G-SDI, Light Sensor Port, Outputs: HDMI 1.3 (Loop), HDMI (PVW / MVR), Single Link DVI (Loop), 3G-SDI (Loop), Max pixels per LED out (port): 650,000 pixels, Total pixels: 2.6 million pixels, Control options: Ethernet, USB, It integrates video processing and control. It's capable of receiving a variety of video signals and processing high-resolution images. Model -VX400 |
| 462 | PA & Display system;To supply and install the LED wall structure, including frame fabrication, panel mounting, electrical setup, cable management, and final testing with alignment and calibration. |
| 463 | PA & Display system;Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC |
| 464 | PA & Display system;Supplying and fixing 17U floor mount rack (Dimension-DxWxH – 800x600x954 mm) as per specification No. WG-NAS/RAK |
| 465 | Lift;Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 466 | Lift;Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 467 | Lift;Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 468 | Lift;Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 469 | Lift;Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 470 | Lift;Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. |
| 471 | Lift;Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 472 | Lift;Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 473 | Lift;Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 474 | Lift;Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 475 | Lift;Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 476 | Lift;Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 477 | Lift;Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 478 | Lift; SITC of Electric Traction Passenger Lift with · Rated capacity :- 10 Passenger/680Kg · Floors :- G+3 floor (4 Stops/4 Landings) · Travel :- 3 to 4.2 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of 1300mm wide x1350mm deep x 2250mm high · Lift shaft available having clear size of 2100mm wide x 2000mm deep, 1500mm Pit depth, ………mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min.18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. |
| 479 | Lift; For Lift having 900mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. |
| 480 | CCTV;Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 481 | CCTV;Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 482 | CCTV;Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete. |
| 483 | CCTV;Supplying, erecting, testing and commissioning of 3kVA capacity online pure sine wave with backup time of 6 hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS |
| 484 | CCTV;Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete (24V Series Parallel Combination) |
| 485 | CCTV;Supply, Installation, Testing and Commissioning of 5MP Outdoor Dome camera with 1/2.9\\" CMOS, 4 to 8 mm Automatic Varifocal (AVF) lens, Effective pixels 2520 x 1440, 25fps, Sensitivity - Color 0.1 lx Mono 0.01 lx With IR 0.0 lx, IR Range- min 30Mtrs (Detection), 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, iDNR, Quad streaming, Privacy Mask, Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Speed, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Motion, tamper and audio detection, The system should be able to simultaneously trigger any 08 user defined rules on the cameras, Audio Streaming Full-duplex / half duplex, MicroSD card slot for edge recording support min 1.5TB or Better, FTP, Dropbox and e-mail applications, AES/FIPS encryption, signed firmware, 3 axis adjustment, ONVIF Profile S & G & T, PoE, IP66 & NEMA 4k, IK10, CE, FCC, UL certified & NDAA compliant. 5 years OEM warranty.Mode NDE‐5503‐AL-IN, |
| 486 | CCTV;Supply, Installation, Testing and Commissioning of 5MP Outdoor Bullet camera with 1/2.9\\" CMOS, 4 to 8 mm Automatic Varifocal (AVF) lens, Effective pixels 2520 x 1440, 25fps or better, Sensitivity- Color 0.1 lx Mono 0.01 lx With IR 0.0 lx, IR Range- min 30Mtrs (Detection), 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, iDNR, Quad streaming, Privacy Mask, Rule based alarms, Analytics like Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 2D tracking based on Duration, Size, Aspect ratio v/h, Speed, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Motion and tamper detection, The system should be able to simultaneously trigger any 08 user defined rules on the cameras, Camera should be able to count number of objects with minimum 60 objects at a time in scene in both moving and static condition with more than 90%accuracy. It should not give false alarms caused by challenging environment such as rain, wind(moving trees), water reflection, shadows etc. Camera should also reliably classify person, vehicle in scene, Audio Streaming Full-duplex / half duplex, MicroSD card slot for edge recording support min 1.5TB or Better, FTP, Dropbox and e-mail applications, AES/FIPS encryption, signed firmware, 3 axis adjustment, ONVIF Profile S, G & T, PoE, IP66, IK10, CE, FCC, UL cerified & NDAA Complied. 5 years OEM warranty. Model-NBE-3703-AL. |
| 487 | CCTV;Supply, Installation, Testing and Commissioning of (4 x 5MP) Multi-Lens camera with each lens shall have 1/2.9\\" CMOS, 4 to 7 mm Automatic Varifocal (AVF) lens, Effective pixels 2560 x 1440, 30fps, Sensitivity- Color 0.01lx, Mono 0.01lx, IR: 0.0lx, min 30Mtrs IR Distance (Detection), 120dB Wide Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264, M-JPEG Video compression, White balance, Backlight Compensation, iDNR, Quad streaming, Privacy Mask Rule based alarms, Line crossing, Enter / leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Speed, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Built-in mic, Motion, tamper and audio detection, Audio Streaming Full / Half duplex, Camera deep learning ability, 2D/3D tracking, The system should be able to simultaneously trigger any 08 user defined rules on each lens of the cameras, MicroSD card slot for edge recording support upto 1.5TB, FTP, Dropbox and e-mail applications, AES/FIPS encryption, signed firmware, IP65, NEMA Type 4X, IK10, ONVIF Profile S, G & T, PoE, CE, FCC, UL, BIS certified & NDAA Compliant, 5 years OEM warranty.Model - NDM‐7703‐AL. |
| 488 | CCTV;Supply, Installation, Testing and Commissioning of Management Server, fully featured VMS based video recording and management solution with scalable min 64 Channels, RAID 5 configuration, Hot-swappable hard drives, Dedicated storage operating system delivers robust, secure operation, System Manager for operation mode selection, software setup and upgrades, Advanced user and alarm management, Intel® Core™ i3 Processor, 3.20 GHz, 6MB Cache, min 08GB RAM, 1U Rack Mount, DVD, 4 Trays: 3.5\\" SATA, 7200 rpm, max 18TB per HDD slot (4 x 18TB) supported, OS Strorage 256 SSD, Connectivity: min 02 USB, Intel® onboard Graphics, Video output: 3, 2 RJ45 Gigabit Ethernet LAN ports (teamed), 1 IPMI BMC port, Min recording bandwidth 350 Mbps, Microsoft Windows Server IoT 2022 for Storage Workgroup (64-bit), Operating Temperature 0°C to +35°C, Relative humidity 10 to 85% (non-condensing), UL, CE, FCC, BIS, TAA Certified & NDAA Compliant.Video Managment software (VMS) with Live viewing of multiple cameras, Local recording and snapshots, PTZ control and digital zoom, Playback and export from storage, Motion and forensic search, Multi-screen grid selection (1, 2X2, 3X3 and 4X4), Sequencing selection, Audio and volume control, Configuration manager shortcut, Log-off and help, Task panels for snapshots (BMP, JPG or PNG format), favorite view design.Licanse :- 5 yrs SMA License for MBV-BPLU-DIP, 5 yrs SMA license for MBV-XCHAN-PLU Channel Exp Lics (Camera / Decoder) Licenses ; Model- DIP-6440IG-00N (1) |
| 489 | CCTV;Supply Installation Testing & commissioning of Intel Xeon W-2123 (3.6 GHz), 16GB RAM, 256GB SSD, 2GB Quadro P620 Graphic Card, Serial Card, keyboard, Mouse, Win10 64bit OS, 1G Network Port, w/o Monitor. |
| 490 | CCTV;Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD |
| 491 | CCTV;Supplying & erecting 65\\" professional LED display with 1920 *1080 ( Full HD) Display, suitable for 64 channel NVR and following featuresBrightness: minimum 500 Cd/m2Contrast Ratio: minimum 1000:1Viewing angle: 178/178 deg.Response time: maximum 8 msInputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON |
| 492 | Utility pump;Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON. |
| 493 | Utility pump;Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 494 | Utility pump;Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 495 | Utility pump;Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 496 | Utility pump;Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 497 | Utility pump;Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 498 | Utility pump;Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 499 | Utility pump;Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 500 | Utility pump;Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 501 | Utility pump;Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. |
| 502 | Utility pump;Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 503 | Utility pump;Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 504 | Utility pump;Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 505 | Utility pump;Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 506 | Utility pump;Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 507 | Utility pump;Supplying and erecting minimum Three & above star rated submersible pump set of 3.75 KW/5 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 60 to 290 LPM discharge at 112 to 12 m head & discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP (Borewell Depth = 60Mtr) |
| 508 | Utility pump;Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP |
| 509 | Utility pump;Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 510 | Utility pump;Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc . |
| 511 | Utility pump;Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). |
| 512 | Utility pump;Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. |
| 513 | Utility pump;Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. |
| 514 | Utility pump;Supplying and erecting CI flange 50 mm. dia with necessary nuts bolts and washers with rubber seal in position complete. |
| 515 | Facade Lighting;Providing and Erecting Indoor Seamless Concled (Continous) Track Light Track Suitable for 36W, 24W, 9W,etc (Multiple Wattage) (5600K, 3000K) White and Warm White Linear Lights, Magnetic Electric Light of various types such as Spot Light, Movable Lense Light,etc, Tracks, Supports, Bends, Circular Bends, etc, Connections, Drivers, and including all accessories Must be installed as per directed by Executive Engineer, Engineer in-charge and Project Consultant. |
| 516 | Facade Lighting;Providing and Erecting Lense Type Linear Foldable Magnetic Track Light compatiable to fix with the track. Having CCT of 3000K to 5600K (Warm White) of Wattage 24Watt. (220MM Length) Must be installed as per directed by Executive Engineer, Engineer in-charge and Project Consultant. |
| 517 | Facade Lighting;Providing and Erecting Track type Foldable Magnetic Track Spot Light compatiable to fix with the track. Having CCT of 3000K to 5600K (Warm White) of Wattage 18 Watt. Must be installed as per directed by Executive Engineer, Engineer in-charge and Project Consultant. |
| 518 | Facade Lighting; Supply and erection of 1200mm Laser Cut Design Static 3000K Light Pole Bollard 12Watt System wattage (+/-10%) with LED having CRI >/= 70 and residual flux of 70% (L70) @ 50,000 hours at Ta of 25°C. Colour temperature (CCT) of 3000K. The luminaire shall be suitable for operating within temperature range from - 10°C to + 40°C. with Macadam = 5. Post is 0.9m height and made from Aluminium and base plate made of Al Plate and welded to the Al Post. The diffuser is Optical grade opal PMMA. Static 3000K Light System is made from Light Engine from a rigid printed circuit board designed and made in India. The luminaire should be with an effective heat sink design to maintain the operating temperatures at LED junction and other components within permissible limits corresponding to the designated design life and the IP65 optical compartment. The luminaire should be deigned to operate at any voltage from 140V to 270V, with Power Factor ≥ 0.95 and shall be provided with optional built in Over Voltage and Under Voltage protection and internal surge protection of 4KV. The Manufacturer should have valid ISO 9001:2015 from TUV Rhineland & CE certification, with inhouse 2m Integratin Sphere, IK10, IP, Auto Soaking Facility to maintain and provide a quality warranty Lighting System. DRIVER USED OF EFFICIENCY >85%,PF>0.95,THD<10% |
| 519 | Facade Lighting;Erection &Supply of high quality Static White (3000K) Linear Wall Washer in 1000mm having precies beam angle as per design or site requirement suitable for general lighting applications. Housing to be made of extruded Aluminium alloy with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have electrostatically applied polyester powder coating finish. Luminaire shall be suitable to operate in a temperature range of -10°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 25°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots to insure proper light distribution. Suitable for outdoor weather proof conditions having IP66 ingress protection. Transparent toughened glass having impact resistance protection of IK08. The luminaire shall have system wattage 36W and system lumen output of not less than 2750 lumens, Beam angle should be 10x60 /15x45/25 Degree/As per site condition, The fixture shall have input voltage of 24V DC, provided with external high efficiency Driver operating on 240V AC, Power factor >0.90 @ full Load, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver. Luminaire complying to BIS standard \\"IS 10322\\" ,Color Temperature : 3000K, CRI>80,, Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, LED Makes should be CREE, LumilLED, Osram, Nichia, Bridgelux to insure higher lumen output and brightness with SMD LED chips. The manufacturer should have internal testing equipment’s especial 2m Integrating Sphere, IPX6, IK10, Humidity Chamber. The manufacturere shall submit the LM79 & LM 80 report along with the supply of material along with the BIS certificate. |
| 520 | Facade Lighting;Erection & Supply of high quality RGBW Linear wall washer in 1000mm having precies beam angle as per design or site requirement suitable for façade lighting applications. Housing to be made of extruded Aluminium alloy with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have electrostatically applied polyester powder coating finish. Luminaire shall be suitable to operate in a temperature range of -10°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 25°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots & fringing in color mixing to insure proper light distribution. Suitable for outdoor weather proof conditions having IP66 ingress protection. Transparent toughened glass having impact resistance protection of IK08. Luminaire should have DMX-512 control protocol and should have inbuilt DMX decoder chip. The luminaire shall have system wattage 18W and system lumen output of not less than 710 lumens, Beam angle should be narrow : 10x60 /15x45/25 Degree/As per site condition, The fixture shall have input voltage of 24V DC, provided with external high efficiency Driver operating on 240V AC, Power factor >0.90 @ full load, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver. Luminaire complying to BIS standard \\"IS 10322\\" ,Color Temperature : RGBW, Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, LED Makes should be CREE, LumilLED, Osram, Nichia, Sanan/Lumisee to insure higher lumen output and brightness with SMD LED chips. Luminaire should have pre wired integral male/female waterproof connectors as per IS standard for DMX Loop In/out facility. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, polar curve & LM80 report issued by LED manufacturer along with the BIS certificate. |
| 521 | Facade Lighting;Erection & ofSupply of high quality RGBW Linear wall washer in 500mm having precies beam angle as per design or site requirement suitable for façade lighting applications. Housing to be made of extruded Aluminium alloy with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have electrostatically applied polyester powder coating finish. Luminaire shall be suitable to operate in a temperature range of -10°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 25°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots & fringing in color mixing to insure proper light distribution. Suitable for outdoor weather proof conditions having IP66 ingress protection. Transparent toughened glass having impact resistance protection of IK08. Luminaire should have DMX-512 control protocol and should have inbuilt DMX decoder chip. The luminaire shall have system wattage 18W and system lumen output of not less than 710 lumens, Beam angle should be narrow : 10x60 /15x45/25 Degree/As per site condition, The fixture shall have input voltage of 24V DC, provided with external high efficiency Driver operating on 240V AC, Power factor >0.90 @ full load, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver. Luminaire complying to BIS standard \\"IS 10322\\" ,Color Temperature : RGBW, Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, LED Makes should be CREE, LumilLED, Osram, Nichia, Sanan/Lumisee to insure higher lumen output and brightness with SMD LED chips. Luminaire should have pre wired integral male/female waterproof connectors as per IS standard for DMX Loop In/out facility. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, polar curve & LM80 report issued by LED manufacturer along with the BIS certificate. |
| 522 | Facade Lighting;Erection &Supply of high quality RGBW Floodlight projector having precies beam angle as per design or site requirement suitable for façade lighting applications. Housing to be made of pressure die-cast Aluminium with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have electrostatically applied polyester powder coating finish. Luminaire shall be suitable to operate in a temperature range of -10°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 35°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots & fringing in color mixing to insure proper light distribution. Suitable for outdoor weather proof conditions having IP66 ingress protection. Transparent toughened glass having impact resistance protection of IK08. Luminaire should have DMX-512 control protocol and should have inbuilt DMX decoder chip. The luminaire shall have system wattage 48W and system lumen output of not less than 1930 lumens, Beam angle should be narrow : 8/15/25 Degree/As per site condition, The fixture shall have input voltage of 24V DC, provided with external high efficiency Driver operating on 240V AC, Power factor >0.90 @ full load, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver. Luminaire complying to BIS standard \\"IS 10322 ,Color Temperature : RGBW, Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, LED Makes should beCREE, LumilLED, Osram, Nichia, Sanan/Lumisee to insure higher lumen output and brightness with SMD LED chips. Luminaire should have pre wired integral male/female waterproof connectors as per IS standard for DMX Loop In/out facility. The successful bidder shall submit the following certifications/ reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, polar curve & LM80 report issued by LED manufacturer along with the BIS certificate. |
| 523 | Facade Lighting;Erection &Supply of high quality RGBW Floodlight projector having precies beam angle as per design or site requirement suitable for façade lighting applications. Housing to be made of pressure die-cast Aluminium with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have electrostatically applied polyester powder coating finish. Luminaire shall be suitable to operate in a temperature range of -10°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 35°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots & fringing in color mixing to insure proper light distribution. Suitable for outdoor weather proof conditions having IP66 ingress protection. Transparent toughened glass having impact resistance protection of IK08. Luminaire should have DMX-512 control protocol and should have inbuilt DMX decoder chip. The luminaire shall have system wattage 24W and system lumen output of not less than 980 lumens, Beam angle should be narrow : 8/15/25 Degree/As per site condition, The fixture shall have input voltage of 24V DC, provided with external high efficiency Driver operating on 240V AC, Power factor >0.90 @ full load, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver. Luminaire complying to BIS standard \\"IS 10322 ,Color Temperature : RGBW, Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, LED Makes should beCREE, LumilLED, Osram, Nichia, Sanan/Lumisee to insure higher lumen output and brightness with SMD LED chips. Luminaire should have pre wired integral male/female waterproof connectors as per IS standard for DMX Loop In/out facility. The successful bidder shall submit the following certifications/ reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, polar curve & LM80 report issued by LED manufacturer along with the BIS certificate. |
| 524 | Facade Lighting;Erection &Supply of high quality RGBW Floodlight projector having precies beam angle as per design or site requirement suitable for façade lighting applications. Housing to be made of pressure die-cast Aluminium with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have electrostatically applied polyester powder coating finish. Luminaire shall be suitable to operate in a temperature range of -10°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 35°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots & fringing in color mixing to insure proper light distribution. Suitable for outdoor weather proof conditions having IP66 ingress protection. Transparent toughened glass having impact resistance protection of IK08. Luminaire should have DMX-512 control protocol and should have inbuilt DMX decoder chip. The luminaire shall have system wattage 72W and system lumen output of not less than 2895 lumens, Beam angle should be narrow : 8/15/25/40 Degree/As per site condition, The fixture shall have input voltage of 240V AC, provided with internal high efficiency Driver operating on 240V AC, Power factor >0.90 @ full load, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver. Luminaire complying to BIS standard \\"IS 10322 ,Color Temperature : RGBW, Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, LED Makes should beCREE, LumilLED, Osram, Nichia, Sanan/Lumisee to insure higher lumen output and brightness with SMD LED chips. Luminaire should have pre wired integral male/female waterproof connectors as per IS standard for DMX Loop In/out facility. The successful bidder shall submit the following certifications/ reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, polar curve & LM80 report issued by LED manufacturer along with the BIS certificate. |
| 525 | Facade Lighting;Erection &Supply of high quality Static White (3000K) Linear Wall Washer in 1000mm having precies beam angle as per design or site requirement suitable for façade lighting applications. Housing to be made of extruded Aluminium alloy with excellent heat management system to ensure proper heat dissipation and thermal stability of the luminaire. The luminaire shall have electrostatically applied polyester powder coating finish. Luminaire shall be suitable to operate in a temperature range of -10°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 25°C. The lens shall be made of anti-aging & anti UV-PMMA/PC material and able to minimize hot spots to insure proper light distribution. Suitable for outdoor weather proof conditions having IP66 ingress protection. Transparent toughened glass having impact resistance protection of IK08. The luminaire shall have system wattage 24W and system lumen output of not less than 1950 lumens, Beam angle should be 10x60 /15x45/25 Degree/As per site condition, The fixture shall have input voltage of 24V DC, provided with external high efficiency Driver operating on 240V AC, Power factor >0.90 @ full Load, internal Surge protection 4KV and other protections including OCP, OVP, SCP, OTP shall be provided in the driver. Luminaire complying to BIS standard \\"IS 10322\\" ,Color Temperature : 3000K, CRI>80,, Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, LED Makes should be CREE, LumilLED, Osram, Nichia, Bridgelux to insure higher lumen output and brightness with SMD LED chips. The manufacturer should have internal testing equipment’s especial 2m Integrating Sphere, IPX6, IK10, Humidity Chamber. The manufacturere shall submit the LM79 & LM 80 report along with the supply of material along with the BIS certificate. Including All fixing material and Drivers. |
| 526 | Facade Lighting;Erection &Supply of LED Flexible Strip light (RGBW) with IP67 rating sealed with anti-UV and anti-UV aging silicon without color shifting. Lumen output 50Lm/W, 50Watt/5Mtr.Universal PCB width for perfect installation with aluminum profile. SMD LED's, CRI80, RGBW, 120LEDS/M, 15W/m, 24V dc, 10mm white PCB, overall width 12mm after IP rated, Supply voltage 24VDC, PCB Type: 2oz white FPC, OSP, Class III for safety use, Long lifespan 50K hrs. L70B50@25℃ , High density of LED array for dot-free linear lighting performance, better color consistency for visual comfort,. Lead cable (300mm) with suitable numbers of clip, screw, end caps , mounting tracks and waterproof connector. with 3 years warranty. Compactable with DMX Controller. |
| 527 | Facade Lighting;Erection &Supply of DMX Controller System with Standalone interfaces along with Button Panel for scene changing. Controller should deliver 512 DMX channels for entry-level budgets and shall have the options to upgrade upto 4 universe, users seeking an easy-to-operate DMX control system. Newly designed aluminium housing with beautiful finish and updated electronics that work with all the latest Pixelerr software Capable of various trigger options and equipped with DC 5-24V input. It is the perfect hardware for easy integration projectsDMX Output: 512 Out channels PC and 512 Out Stand Alone. upgradtion upto 2048 Channels Input Supply: USB-C (5V-24V. DC, 0.3A). Memory: Internal memory (8 Mb, 5K to 20K DMX step capacity. )Zones: 10 Zones, play 10 scene/sequence at time in Stand Alone. Infrared optional (scenes, play, pause, dimmer, speed) : Additional Infrared (optional) commands and additonal commands on triggers. DMX Mode: DMX In/Out, DMX Splitter x 4 ports, DMX Record, DMX Trigger Stand Alone Options: 16-bit and fine channel management, Cross Fade time between scenes, Default start scene when power up.Triggers: Real time clock and calender for each scene, Wi Light 2 Application (iOS, Android), 12 smart contact on 3-5V, Commands from contacts, UDP/ethernet triggers and commands.Max DMX outputs (USB): x12 USB interfaces connected = 12 DMX max Power: DC In USB-C 5V DC + 5-24V DC Input on Terminal Block Housing: Strong Aluminum DIN Rail cabinet,Connectors: USB-C, 3 pin Screw terminalBlockOperating Temperature: -10 to +50 C°IP Rating: IP20 |
| 528 | Facade Lighting;Erection &Supply of 6 output DMX Splitter cum Booster works as DMX signal amplifier and signal splitter. The signal amplification/boosting function should amplify the DMX master controller’s output DMX signal up to 200 meters by using an ideal DMX cable. The DMX Splitter & Amplifier’s all six output terminals are optically isolated. All six outputs should have an independent output 9V coil transformer to boost the DMX signal and capable of 24V reverse voltage protection. The Splitter/booster should be capable of working on 220V/230V line voltage AC and must have over voltage /under voltage protection. Operating temperature shall be -10 to 50 Deg Celsius. The Splitter/booster should be equipped with lightning protection. Protection Rating IP 20. Splitter/Booster should be equipped with included mounting brackets which allow multiple installation options for rack, floor, surface, ceiling mounting. Connector blocks for DMX IN and OUT connections for firm and solid DMX signal. The signal strength of DMX signal should be above 4 V at each output for reliable signal strength for a maximum of 6x32 lights in a chain and to 200 meters maximum length to the last light. Equipped with an accessible fuse carrier for surge protection and supplied with 1.5sq. mm 3 core cable pre-connected. |
| 529 | Facade Lighting;Erection &Progarmming and testing of controllers. 1. Addressing, Patching and Programming DMX Light Fixtures 2. Creating many number of sequences as per client's requirement. 3. Training of the site technicians. |
| 530 | Facade Lighting;Erection &DMX cable (single pair) having one 22AWG pair stranded (7x30) tinned copper conductors, Datalene (FHDPE) insulation, twisted pairs, overall Beldfoil shield (100% coverage) plus tinned copper braid, PVC jacketCable. Beldon make or equivalent. |
| 531 | Facade Lighting;Erection &Supply of IP67 \\"I\\" Connectors for DMX signal terminations having 3 pole cable connector, Heavy-duty, robust and strong, Integrated terminal block design. 10 AMP Current-Carrying capacity/terminal. One-piece, 3-pole in-line waterproof field assembly. Compact, therefore more options to accommodate during installation. Screw type terminals make installation easier. |
| 532 | Facade Lighting;Erection &Supply of IP67 \\"T\\" Connectors having 5 pole cable connector, Heavy-duty, robust and strong, Integrated terminal block design. 20 AMP Current-Carrying capacity/terminal. One-piece, 5-pole in-line waterproof field assembly. Compact, therefore more options to accommodate during installation. Screw type terminals make installation easier. |
| 533 | Facade Lighting;Erection &Supply of 600mm long leader cable with IP67 5-Pin Male/Female connector at one end. The Pin material should be of high quality and corossion resistance. |
| 534 | Facade Lighting;Erection &Supply of 1000mm long Jumper cable with IP67 5-Pin Male-Female connector at both end. The Pin material should be of high quality and corossion resistance. |
| 535 | Facade Lighting;Erection &Enclosure for DMX controller: Size 300 x 300 x 150 mm, plain sides, polyester, gray cover, polyester enclosures have superb temperature, UV and chemical resistance and high impact strength, Degree of protection: IP 66, Impact strenght: IK 09, Material, base: Glass reinforced polyester (GRP) Material, cover: Polycarbonate Material, gasket: Polyurethane, Colour: RAL 7035, 1 no. breather. |
| 536 | Facade Lighting;Erection &Enclosure for DMX splitter: Size 300 x 600 x 132 mm, plain sides, grey cover, Degree of protection: IP 66/ IP 67, Impact strenght: IK 08, Material, base: Fiberglass reinforced polycarbonate, Material, cover: Polycarbonate, Material, cover screws: Polyamide, Material, gasket: Polyurethane, Colour: RAL 7035, 1 no. breather. Including mounting arrangement for DMX splitter & suitable polyamide glands. |
| 537 | Facade Lighting;Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail