Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Sub-Head : Earth Work |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. |
| 3 | All kinds of soil |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50 m and lift up to 1.5m, as directed by Engineer-in-Charge. |
| 5 | Ordinary rock |
| 6 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 7 | All kinds of soil. |
| 8 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains not exceeding 1.5m in width or 10 sqm on plan including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. |
| 9 | Ordinary rock |
| 10 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m including getting out the excavated soil, and then returning the soil as required, inlayers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : |
| 11 | All kinds of soil |
| 12 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 13 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 14 | Supplying and filling in plinth with Local Fine sand under floors, including watering, ramming, consolidating and dressing complete. |
| 15 | Sub-Head : Concrete Work |
| 16 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 17 | 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stoneaggregate 40 mm nominal size). |
| 18 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain windowsills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 19 | 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 20 | 1:5:10 [ 1 Cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size] |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 22 | Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps, window sills, copings etc. |
| 23 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 24 | Supplying & back filling with well graded stone boulders of size 150 mm to 300 mm behind retaining wall complete as per the directions of the Engineer-in-charge. (Note :- 30% deductions in measurements shall be made for voids). |
| 25 | Providing and fixing 75 mm dia Rigid PVC pipe (working pressure 4kg./sqcm.) conforming to IS : 13592 type A in retaining walls for use as weep holes, laid to required slope etc. all complete as per the directions of the Engineer-in-charge. |
| 26 | Providing and laying in position cement concrete 1:3:6 (1cement:3 coarse sand: 6 graded stone aggregate 40mm nominal size) with 40% plums/stone boulders of specified grade and size and curing complete excluding the cost of centring & shuttering in retaining walls/ breast walls. The size of plums shall usually be 150mm to 300mm as per the directions of the Engineer-in-charge. |
| 27 | Sub-Head : Reinforced Cement Concrete |
| 28 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 29 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 30 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 31 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 32 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 33 | Centering and shuttering including strutting, propping etc. and removal of form for for all heights: |
| 34 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 35 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 36 | Suspended floors, roofs, landings, balconies and access platform. |
| 37 | Shelves (Cast in Situ) |
| 38 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 39 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 40 | Edges of slabs and breaks in floors and walls. |
| 41 | Under 20 cm wide |
| 42 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all floor levels. |
| 43 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 44 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand) |
| 45 | Making holes of 150mm dia and 100 to 200 mm depth in RCC slab by core cutting method or other suitable method for fixing SCI/ CI/ PVC pippes and sealing the joints with silicone adhesive and WATER sealant grout / white cement ro make water tight joint after fixing of pipes including scaffolding whereever requires all complete as per the direction of the Engineer-in-charge. |
| 46 | Sub-Head : Masonry Work |
| 47 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 48 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 49 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 50 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 51 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 52 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 53 | Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. |
| 54 | Brick edging 7cm wide 11.4cm. deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). |
| 55 | Providing and laying autoclaved aerated cement blocks masonry with 100mm/150mm/ 230mm/ 300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer in-Charge. (The payment of RCC band and reinforcement shall be made for separately). |
| 56 | Sub-Head : Cladding Work |
| 57 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 58 | Granite stone slab colour black, Cherry/Ruby red |
| 59 | Area of slab upto 0.50 sqm |
| 60 | Area of slab upto 0.50 sqm |
| 61 | Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location inmarble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 62 | Making hole of 40mm dia. [approx.] in granite shelf for housing gas pipe including finishing complete as per the direction of E-in-C. |
| 63 | Providing and fixing Ist quality ceramic glazed Rectified wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 64 | Sub-Head : Wood and PVC Work |
| 65 | Extra for providing frosted toughened glass panes 6 mm thick instead of plain float glass panes 6 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 66 | Deduct for not providing hinges in doors, windows or clerestory window shutters with : |
| 67 | ISI marked Stainless steel butt hinges with stainless steel screws : |
| 68 | For 2nd class teak wood and other class of wood shutters |
| 69 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : |
| 70 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 71 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 72 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : |
| 73 | 35 mm thick shutters. |
| 74 | with ISI marked M.S. pressed butt hinges bright finished of required size - Second class teak wood. |
| 75 | Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete : |
| 76 | 25 mm dia. |
| 77 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete. |
| 78 | Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality with necessary screws etc. complete. |
| 79 | Size 50 mm |
| 80 | Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete. |
| 81 | Providing and fixing bright /matt finished Stainless Steel sliding door bolts of approved quality & make with necessary screws etc all complete as per direction of Engineer-in-Charge. |
| 82 | 300x16 mm |
| 83 | 250x16 mm |
| 84 | Providing and fixing bright /matt finished Stainless Steel tower bolt of approved quality & make with necessary screws etc all complete as per direction of Engineer-in-Charge.. |
| 85 | 250x10 mm |
| 86 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. |
| 87 | 125mm |
| 88 | 100mm |
| 89 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and shade with necessary screws etc. complete. |
| 90 | Twin rubber stopper |
| 91 | Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. |
| 92 | Double strip (horizontal type) |
| 93 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 94 | Providing and fixing to existing door frames. |
| 95 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. |
| 96 | Providing and fixing 6mm thick ISI marked commercial plywood of Century or equivalent make to frames, backings, studding and similiar places with screws, nails etc. all complete as per the directions of the Engineer in Charge.(Note:- Frames, backing or studding to be paid separately). |
| 97 | Providing and fixing fly proof stainless steel grade 304 wire gauge,to windows,clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.50 mm all complete as per the directions of Engineer-in Charge. |
| 98 | With uPVC glazing beading which shall be paid in main item. |
| 99 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. |
| 100 | After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. |
| 101 | Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately. |
| 102 | Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: |
| 103 | (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 |
| 104 | (ii) Sites with structure height more than 20m for all wind speeds. |
| 105 | Three track three panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. |
| 106 | Using R4 series with frame (115mm & above) x (45mm & above) & sash (44mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on two end panels along with multi-point locking system. (Height above 1.8 meter). |
| 107 | Fixed window / ventilator with mullion / transom. |
| 108 | Using R3 series with frame (55mm & above ) x (45mm & above) & mullion (55mm & above) x (65mm & above). (Height upto 2.5 meter) |
| 109 | Providing and fixing glass pans in fixed.openable portion of windows,ventilators and doors shutters etc. all complete as per the directions of Engineer-in Charge (Note : Area of opening of glass panes excluding portion inside rebete shall be measured for payment) |
| 110 | Float glass panes of thickness 4 mm |
| 111 | Providing and fixing cuboard shutter with 19 mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2 mm thick PVC edege banding tape with hot glue by edege bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge. (Payment of providing and fixing auto closing hinges shall be paid separately) |
| 112 | Providing and fixing 19 mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes, shelves, racks, almirah, cupboard and drawer etc. including necessary nails, screws etc. complete as per direction of Engineer-in-charge. |
| 113 | Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydrarlic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. |
| 114 | Providing and fixing glazing in uPVC windows, all complete with uPVC beading as per manufacturer's specification and direction of of Engineer-in-charge. ( Note :- uPVC beading to be paid in basic frame item). (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). |
| 115 | 6mm thick toughened glass . |
| 116 | Providing and fixing MS powder coated set of five pegs (Hooks) of approved quality with MS screws all complete as per direction of the Engineer-in-charge . |
| 117 | Providing and fixing PVC rubber Silencer on the rear side of door shutter to avoid collision between wall and door shutter as per directions of Engineer in Charge. |
| 118 | Providing and fixing fly proof stainless steel grade 304 wire gauge with average width of aperture 1.40 mm in both directions with wire of dia 0.50 mm to uPVC windows, doors & ventilators all complete with uPVC beading as per manufacturer's specification and direction of Engineer-in-charge. (Note :- uPVC beading to be paid in basic frame item). |
| 119 | Sub-Head : Steel Work |
| 120 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 121 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 122 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: |
| 123 | Profile C |
| 124 | Fixing with adjustable lugs with split end tail to each jamb. |
| 125 | Profile D of size 125x 60 mm with double rebate to suit the wooden shutter. |
| 126 | Fixing with adjustable lugs with split end tail to each jamb. |
| 127 | Modified Profile D - of size 125 x60 mm with triple or double rebate to suit the shutter and glass panes |
| 128 | Fixing with adjustable lugs with split end tail to each jamb. |
| 129 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 130 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 131 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. |
| 132 | M.S. tube. |
| 133 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 134 | Sub-Head : Flooring |
| 135 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 136 | 40 mm thick with 20 mm nominal size stone aggregate |
| 137 | Chequerred precast cement concrete tiles 22 mm thick in footpath &courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 138 | Light shade pigment using white cement. |
| 139 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 140 | Providing and laying full body Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 141 | Double charge vitrified tile polished finish of size |
| 142 | Size of Tile 600 x 600 mm |
| 143 | Providing and laying full body Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 144 | Glazed Vitrified tiles Matt/Antiskid finish of size |
| 145 | Size of Tile 600 x 600 mm |
| 146 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting,riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 147 | Size of Tile 600x600 mm |
| 148 | Providing and laying GVT Vitrified tiles of approved make and design (thickness to be specified by manufacturer) in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 149 | GVT Vitrified Tiles of Size 600x1200 mm |
| 150 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardener and 0.20 kg of resin per kg), including filling/grouting and finishing complete as per direction of Engineer-in-charge. |
| 151 | Size of Tile 600 x 600 mm |
| 152 | Size of Tile 600x1200 mm |
| 153 | Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles |
| 154 | Sub-Head : Roofing |
| 155 | Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 156 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 : 2000 |
| 157 | Providing and fixing precoated galvalumn iron profile sheets of Jindal (Colouron)/ Tata steel (Durashine)/Bhushan make (size, shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 158 | Providing and fixing precoated galvalumn steel sheet of Jindal (Colouron)/ Tata steel (Durashine)/Bhushan make, roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 159 | Ridges / Valley plain (500 - 600mm). |
| 160 | Flashings/ Aprons.( Upto 600 mm) |
| 161 | Sub-Head : Finishing |
| 162 | 12 mm cement plaster of mix : |
| 163 | 1:6 (1 cement: 6 coarse sand) |
| 164 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 165 | 1:6 (1 cement: 6 coarse sand) |
| 166 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
| 167 | 1:4 (1 cement: 4 fine sand) |
| 168 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 169 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 170 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 171 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 172 | Two coats |
| 173 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 174 | Two or more coats on new work. |
| 175 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 176 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 177 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 178 | Providing and fixing 22 gauge chiken wire mesh in required size and shape 150 mm wide and fixed with Bombay nails on vertical and horizontal junctions of RCC and AAC block masonary i/c scaffolding, all leads and lifts etc. Before plastering of surface all complete as per direction of E-In-Charge. |
| 179 | Sub-Head : Road Work |
| 180 | Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineer in-Charge. |
| 181 | 60 mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern. |
| 182 | Sub-Head : Sanitary Installations |
| 183 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 184 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 185 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : |
| 186 | W.C. pan with ISI marked white solid plastic seat and lid |
| 187 | Providing and fixing white vitreous china flat back half stall urinal of size 80x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : |
| 188 | Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 189 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 190 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 191 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 192 | Kitchen sink without drain board |
| 193 | 470x420 mm bowl depth 178 mm. |
| 194 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : |
| 195 | Size 450x300x150 mm |
| 196 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge. |
| 197 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 198 | Semi rigid pipe |
| 199 | 32 mm dia |
| 200 | 40 mm dia |
| 201 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 202 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 203 | Providing and fixing toilet paper holder : |
| 204 | C.P. brass |
| 205 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 206 | 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 207 | Providing and laying UPVC SWR pipes 110mm dia. [Type-B category] conforming to IS:13592-2013 of Supreme/ Diplast /Finolax make, including jointing with suitable PVC adhesive complete as per the direection of Engineer in Charge. |
| 208 | Providing and laying UPVC SWR pipes fittings ( Type B category) of Supreme/ Diplast /Finolex make including jointing with suitable PVC adhesive complete as per the direection of engineer in Charge. |
| 209 | Bend 87.5° |
| 210 | 110 mm bend |
| 211 | Bend 87.5° with door |
| 212 | 110 mm bend |
| 213 | Single tee without door |
| 214 | 110x110x110 mm |
| 215 | Single tee with door |
| 216 | 110x110x110 mm |
| 217 | Coupler |
| 218 | 110mm |
| 219 | Vent Cowl : 110mm |
| 220 | Floor Trap 110 mm with CP Grating |
| 221 | Sub-Head : Water Supply |
| 222 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall. |
| 223 | 20 mm dia. nominal bore |
| 224 | 25 mm dia. nominal bore |
| 225 | 40 mm dia. nominal bore |
| 226 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps i/c making good the walls etc. concealed pipe including painting with anticorrosive bitumastic paint, cutting chases and making good the wall |
| 227 | 15 mm dia nominal bore |
| 228 | 20 mm dia. nominal bore |
| 229 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work |
| 230 | 15 mm dia. nominal bore |
| 231 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 232 | 25 to 40 mm nominal bore |
| 233 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 234 | 25 mm nominal bore |
| 235 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 236 | 20 mm nominal bore |
| 237 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 238 | 45 cm length |
| 239 | 15 mm nominal bore |
| 240 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 241 | 100 mm diameter |
| 242 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : |
| 243 | 20 mm dia. nominal bore |
| 244 | 25 mm dia. nominal bore |
| 245 | 40 mm dia. nominal bore |
| 246 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : |
| 247 | 15 mm diameter pipe |
| 248 | Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : |
| 249 | 15 mm diameter pipe |
| 250 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) |
| 251 | 15 mm nominal bore |
| 252 | 20 mm nominal bore |
| 253 | 25 mm nominal bore |
| 254 | 40 mm nominal bore |
| 255 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 256 | Circular tank |
| 257 | Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 : |
| 258 | 15 mm nominal bore |
| 259 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 260 | 15 mm nominal bore. |
| 261 | Providing and fixing C.P. brass stop cock( concealed) of standard design and of approved quality confirming to IS:8931 : |
| 262 | 15 mm nominal bore |
| 263 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 264 | 15mm nominal bore |
| 265 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 266 | Providing & fixing 15 mm dia CP Brass kitchen sink wall mixer of Victor make of Cera / Jaquar / Ess-Ess or equivalent all complete as per the direction of the Engineer-in-charge |
| 267 | Providing & fixing 15 mm dia CP Brass wall mixer with CP bend for shower arrangement for bathrooms of Victor make of Cera / Jaquar / Ess-Ess or equivalent all complete as per the direction of the Engineer-in-charge |
| 268 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 269 | Providing and fixing G.I. tank nipple including cutting and threading the pipe and making long screws etc. complete (New work) |
| 270 | 15 mm nominal bore |
| 271 | 20 mm nominal bore |
| 272 | 25 mm nominal bore |
| 273 | Sub-Head : Drainage |
| 274 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : |
| 275 | 150 mm diameter |
| 276 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: |
| 277 | 150 mm diameter S.W. pipe |
| 278 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : |
| 279 | 100x100 mm size P type |
| 280 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 281 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 282 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg(weight of cover 23 kg and weight of frame 15 kg) : |
| 283 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 284 | Extra for depth for manholes |
| 285 | Size 90x80 cm |
| 286 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 287 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : |
| 288 | With 20X20 mm square bar diameter round bar |
| 289 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality |
| 290 | L D- 2.5 |
| 291 | Rectangular shape 600x450mm internal dimensions |
| 292 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 293 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 294 | Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 295 | Sub-Head : Aluminium Work |
| 296 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 297 | For fixed portion |
| 298 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 299 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). |
| 300 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 301 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 302 | Pre-laminated particle board with decorative lamination on both sides. |
| 303 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 304 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 305 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors ,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. |
| 306 | With brass cover plate minimum 1.25 mm thickness. |
| 307 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 308 | Upto 5mm depth and 5 mm width |
| 309 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 310 | Sub-Head : Water Proofing |
| 311 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of :i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand)mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7Kg. per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) |
| 312 | Providing and fixing GI Spouts in depressed portions, 40mm dia and 60Cm long in Cement Mortar 1:4 (1 Cement: 4 Fine Sand) i/c making arrangement for smooth & efficient functioning of the spout as per the direction of the Engineer-in-charge. |
| 313 | ELECTRICAL COMPONENT SUB HEAD-I (Wiring) |
| 314 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 315 | Group A |
| 316 | Group C |
| 317 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 318 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 319 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 320 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 321 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 322 | 4 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire |
| 323 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 324 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 325 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 326 | 20 mm |
| 327 | 25 mm |
| 328 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. |
| 329 | 2x1.5 sq. mm |
| 330 | 3x1.5 sq. mm |
| 331 | 4x1.5 sq. mm |
| 332 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 333 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 334 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. of 3 pin 5/6 A modular socket outlet and 2 nos. of 5/6 A modular switch, connections etc. as required. |
| 335 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 336 | 5/6 amps switch |
| 337 | 15/16 amps switch |
| 338 | 3 pin 5/6 amp socket outlet |
| 339 | 6 pin 15/16 amp socket outlet |
| 340 | TV antenna socket outlet |
| 341 | RJ-45 Jack with Cat 6 One Module |
| 342 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 343 | 1 or 2 Module (75mmX75mm) |
| 344 | 4 Module (125mmX75mm) |
| 345 | 8 Module (125mmX125mm) |
| 346 | 12 Module (200mmX150mm) |
| 347 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 348 | 1 run of cable |
| 349 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 350 | 1 run of cable |
| 351 | S/Fixing hexagonal fan box of size 150 mm dia made outof 16 SWG MS sheet including 12mm dia MS rod in the U shape with its vertical legs bent horizontally at the top at least 19 cm on either side and bound to the top reinforcement of the roof at the time of casting i/c S/F 3 mm thick phenolic laminated sheet at the bottom complete as reqd. |
| 352 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 353 | SUB HEAD-II (Distribution System) |
| 354 | Supplying and fixing following way, vertical type TPN, sheet steel, MCB distribution board, 415 volts having provision for MCCB as incomer, on surface/ recess, complete with metal door, tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCCB/ RCCB/ Isolator) |
| 355 | 4WAY (4+4+4) Double Door ( Model:-DTVTL004DD of Lauritz & Knudsen |
| 356 | Supplying and Fixing Four pole, 100A rating MCCB with Fixed Thermal-Fixed Magnetic Release, breaking capacity 10KA at 415V with With Spreader Links for interconnection in the existing vertical DB i/c making interconnection etc as required. (M/s Lauritz & Knudsen , Model-DY125U 100A 10kA FTFM -EM90984OOKO or equivalent similar superior make) |
| 357 | Supplying and fixing following way, horizontal type SPN / TPN, sheet steel, MCB distribution board, 240/ 415 volts, on surface/ recess, complete with metal door, tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) |
| 358 | 16Way SPN (2+10) Double Door Glazed ( Make& Model- Lauritz & Knudsen Model-DTTPN004GD-Tripbox NXT) |
| 359 | 4 Way TPN (8+12) Double Door Glazed ( Make& Model- Lauritz & Knudsen Model-DTTPN004GD-Tripbox NXT) |
| 360 | Supplying and fixing following rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 361 | 5 amps to 32 amps, 240 volts Single pole. |
| 362 | 63 amps, 415 volts Four pole. |
| 363 | 63 amps, TP MCB |
| 364 | S/F Following rating MCB power protected unit suitable for operation on 230V single phase AC supply complete with all accessories i/c making interconnection etc as required. |
| 365 | Supplying and fixing 63 Amps., four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 366 | Supplying and fixing Adaptor Box(s) fabricated out of 16 SWG M.S. sheet complete with cutting, welding, painting, sign writing etc. all as required. |
| 367 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 368 | SUB HEAD-III ( Earthing)) |
| 369 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 370 | Supplying and laying 25 mm X 5 mm G.I strip on surface or in recess etc as required. |
| 371 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc.as reqd |
| 372 | Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail