| Sl. No. | Item Description |
| 1 | A. CONSERVATION WORKDe-vegetation of small plants, bushes and rank vegetation from masonry/structures including including hing/gur/lime formulation as specified by the Architect or other patented chemical biocide treatment such as biocide (iso propylamine salt of glyphosate) or other equivalent chemical to roots to avoid further growth including disposal of rubbish to nearest Municipal dumping ground. Lead as per direction of Engineer incharge. The rate is inclusive of open the masonry area upto founded roots ends and filled the joints with lime mortar/grout. (reworking of masonry paid sepratly for this item .) |
| 2 | Providing and fixing double scaffolding system (cup lock type) on the exterior/interior side of building/structure, upto 25 Rmt height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 Rmt centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. |
| 3 | Providing and fixing Scaffolding net of required width made of high density Polyethylene UV stabilized knitted on warp knitting machines having density 100grams/sqm and shading coefficient minimum 75% around the construction site/ for vertical extension as per requirement including fastening/tying with building/scaffolding pipes or with any other fixtures etc. complete as per direction of Engineer-in-Charge. (One time payment shall be made for providing Scaffolding net from start of work till completion of work including shifting if any. The Scaffolding net shall be the property of the contractor on completion of the work) |
| 4 | Removing of old sulphated lime wash/white or colour wash in multiple applications without causing damage to the below stone/brick/plastered surface. Scrubbing (not by scraping which leaves surfaces scarred and scratched ) with bristle brushes and hot water ( Care to be taken if the surface is weak one it will break down). Hot water should be used if the limewash has an oil or tallow binder. Gentle cleaning with air abrasive tools can be used if the wall surface is not very week.The final clean will almost invariably have to be carried out by hand scrubbing and rinsed with clean water on completion. The work should be done under supervision of a trained conservator. |
| 5 | Raking out joints of stone masonry surface to the required width and depth, with due care and precaution, by mechanical / manual means, including preparing and cleaning the surface for re-pointing/ refilling of joints, including disposal of rubbish to the dumping ground within 50 metre lead. |
| 6 | Ruled / Flush pointing on Red sand stone masonry surface with lime, surkhi and marble dust mortar in the ratio of 1:1.5:1/2 {One lime: 1.5 surkhi (50% red and 50% light yellow surkhi ) : 1/2 marble dust}. (The rate is inclusive of all materials & labours involved except scaffolding). |
| 7 | Flooring protection: Covering the existing historic flooring with a layer of of 30mm Plaster of Paris thickness over a layer of high density plastic sheet 150 GSM or 10mm plywood board to ensure that scaffolding/movement of machine do not damage the historic flooring. |
| 8 | Brick work in gauged arches in superstructure above plinth level and upto 15 meters height (or upto floor five level, whichever is lower) including centering and shuttering complete for span up to 6 metres with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in lime mortar 1:1:1 (1 lime: 1 surkhi: 1 coarse sand). |
| 9 | Brick work in plain arches in superstructure above plinth level and upto 15 meters height (or upto floor five level, whichever is lower) including centering and shuttering complete for span up to 6 metres with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in lime mortar 1:1:1 (1 lime: 1 surkhi: 1 coarse sand). |
| 10 | Brick consolidation of Bricks masonry work by removing damaged bricks or masonry along a minor non structural crack and refixing with new bricks to matching the existing masonry by tradinonal method in lime surkhi mortar (1 Lime: 1 Surkhi:1 corse sand) as per direction of Engineer incharge. |
| 11 | Brick masonry in mouldings and cornices (upto 30 cm in projection and 30 cm in depth as per traditional practice) in lime mortar similar to the existing traditional lime mortar 1:1:1 (1 lime: 1 coarse sand: 1 surkhi) after removing the damaged and out of plumb masonary from the vertical surfaces , as directed by Engineer incharge/ Architect, and including all leads, lifts and carriage. All complete. |
| 12 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 13 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) :Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm includingexcavation channel along the wall & rodding etc. complete:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 14 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 15 | Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same |
| 16 | DismantlingDismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. |
| 17 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 Rmts lead. |
| 18 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 Rmts lead as per direction of Engineer-in-charge. : In cement mortar |
| 19 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 Rmts lead as per direction of Engineer - in - charge |
| 20 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 21 | Dismantling jack arch/Plain arch roofing and floors including stacking of serviceable material and disposal of unserviceable material within 50 Rmts lead. |
| 22 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 Rmts lead :Of area 3 sq. Rmts and below |
| 23 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 Rmts lead :Of area beyond 3 sq. metres |
| 24 | Dismantling old Lime/Cement plaster of any thickness and height internal/ external surface and raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 Rmts lead. |
| 25 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 Rmts leadUpto 150mm dia pipe |
| 26 | Dismantling of old wires and conduits including making good of all damage and disposal of unserviceable material within 50 Rmts lead as per direction of Engineer-in- charge. |
| 27 | Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 Rmts lead. |
| 28 | Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 Rmts lead as per direction of Engineer-in- charge. |
| 29 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 Rmts span and 5 Rmts height including stacking the material within 50 Rmts lead.Of sectional area 40 square centimetres and above |
| 30 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 Rmts span and 5 Rmts height including stacking the material within 50 Rmts lead.Of sectional area below 40 square centimetres |
| 31 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceablematerial with in 50 meters lead as directed by Engineer-in-charge. |
| 32 | Dismantling cement asbestos or other hard board/Acrylic ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 Rmts lead. |
| 33 | Carefully removing and breaking the dado & marble platform(upto 30 mm thick) by manually and mechanicaly with low duty Chiseller machine and carting away the debris from the site premise. |
| 34 | Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : |
| 35 | Dismantling concrete flooring or IPS flooring including stacking of serviceable materials and disposal of unserviceable materials within 50 Rmts lead. Upto 75 mm thick. |
| 36 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 Rmts lead.Note: This item includes dismantling of existing cycle stand steel work, includingISMB/ISMC, angles, flats and connected components, complete. |
| 37 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet |
| 38 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 39 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 40 | Carefully dismantling and removing existing split / window type air-conditioning outdoor units mounted on stone façade, including removal of MS brackets, fasteners, anchor bolts, cutting and disconnecting refrigerant pipes, drain pipes and electrical connections, making units safe and lowering to ground level, stacking at specified location, complete as per direction of Engineer-in-Charge. |
| 41 | Carefully dismantling of existing surface-mounted / wall-mounted GI / MS / PVC / CI or similar pipes of diameter up to 150 mm fixed on walls / stone façade / building surfaces at any floor level up to 3rd Floor, including cutting, unfastening of clamps, brackets, supports and joints, careful lowering of dismantled pipes, stacking of serviceable materials at site within 50 metre lead and disposal of unserviceable material, complete as per direction of Engineer-in-Charge. |
| 42 | Dismantling and removing existing electrical wires and cables from external façade / walls up to 10 metre height, including detaching from fixings, careful lowering, stacking of serviceable materials within 50 metre lead and disposal of unserviceable material, complete as per direction of Engineer-in-Charge. |
| 43 | Civil WorkEarth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top- most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift : |
| 44 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 45 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 46 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1 :3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 47 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation7.5 in foundation and plinth in: Cement mortar 1 :4 (1 cement : 4 coarse sand) |
| 48 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1 :4 (1 cement : 4 coarse sand) |
| 49 | Brick work with bricks of class designation 7.5 in superstructure up to two level : Lime mortar 1:1:1 (1 Lime putty: 1 surkhi: 1 coarse sand). ** Note:- Lime mortar ( 1:1:1) to be prepared after proper slaking of lime (the name of kalli chuna from katni or Gotan) (minimum slaking period 15 days) . The mortar ratio is to be strictly followed as per the directions of the conservator. * Sand shall conform to IS 383/ IS 2116/ IS 1542. |
| 50 | 25-40mm lime plaster in two coats with 20 mm base coat in lime mortar 1:1:1 (1 lime: 1 Surkhi: 1 Coarse Sand) and top coat in lime mortar 1:1:1 (1 lime: 1 Surkhi: 1 Fine Sand). * Note:- Lime mortar ( 1:1:1) & lime surkhi mortar (1:2) to be prepared after proper slaking of lime (the name of kalli chuna from katni or Gotan) (minimum slaking period 15 days) . The mortar ratio is to be strictly followed as per the directions of the conservator. ** Sand shall conform to IS 383/ IS 2116/ IS 1542. |
| 51 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.20 mm cement plaster |
| 52 | Providing and creating plaster to achieve an artificial exposed brick masonry appearance by consolidating the existing damaged brickwork with lime mortar in the ratio 1:1:1 (1 part lime : 1 part surkhi : 1 part sand), including the addition of organic additives such as sugarcane molasses, bel extract, methi, etc., as per traditional practices, complete as per the direction of the Engineer-in-Charge. |
| 53 | Providing and applying putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 54 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. |
| 55 | Lime wall painting by any mechanical or manual means with breathable lime paint antiifungal , anti-bacterial and color rentention properties of approved brand , including applying additional coats wherever required to acheive smooth finish in approved shade of color as per direction of engineer-in-charge. |
| 56 | Applying breathable, non-reactive, antifungal, and water repellent Silane/ Siloxane chemical as approved by Archaeological Survey of India/ Engineering-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In- charge (The rate is inclusive of all materials & labours involved except scaffolding) |
| 57 | Providing and fixing or replacing damaged teak wood with well seasoned second class teak wood. wood for door or window frames or members of decorative frame of the same original design, size and patternincluding all mouldings, rebating, holdfasts and any other necessary fittings and finishing with one coat ofprimer complete.Window or Door Frames (upto a section size of 150mm x 100mm).**150x 100mm cross-section frame of second class teak wood as per market availabe well seasoned.**Type of wood- Well Seasoned second class teak wood |
| 58 | Door Restoration by providing and fixing or replacing damaged teak wood with well seasoned second class teak wood double leaves 50mm thick fully glazed openable shutters for doors/windows as per the originaldesign and pattern as instructed by the Architect including all necessary fitting brass hardware like screws,nails, hinges, tower bolts, handles, of the same design, size and weight, etc. complete.Item to also include making all the mouldings and design of the panels as in the original detail with all beading patti as per size etc., Item to include complete finishing of the shutter inclusive of primer andpaint or melamine polish as approved by the Architect. Mode of Measurement: Elevation of visbile entire door/window area shall be measured and paid for.**Type of wood- Well Seasoned second class teak wood |
| 59 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Second class teak wood-35 mm thick. |
| 60 | Float glass panes5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). |
| 61 | Extra for providing frosted glass panes 5 mm thick instead of ordinary float glass panes 5 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 62 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) |
| 63 | Providing and fixing bright finished brass handles with screws etc. complete:100 mm |
| 64 | Providing and fixing bright finished brass handles with screws etc. complete:75 mm |
| 65 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10 mm |
| 66 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :100x10mm |
| 67 | Providing and fixing bright finished brass Aldrop necessary screws etc. complete |
| 68 | IPS-Cement concrete flooring 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement with red oxide, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 69 | Extra for making chequers of approved pattern on cement concrete floors, steps, landings, pavements etc. |
| 70 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 71 | For Suspended floors, roofs, landings, balconies and access platform |
| 72 | Construction of Jack/Vaulted arched roof using Rolled steel joists, fired clay bricks with composite lime mortar mix 1 lime: 3 Slaked lime: 4 Coarse sand: 8 Coarse aggregate (Kafgi Mix) Steel Sections shall conform to IS 808 (1989): Dimensions for Hot Rolled Steel Beam, Column, Channel and Angle Sections*Note:- Lime concrete ( 1:3:4:8) to be prepared after proper slaking of lime (the name of kalli chuna from katni or Gotan) (minimum slaking period 15 days) . The mortar ratio is to be strictly followed as per the directions of the conservator.** Sand shall conform to IS 383/ IS 2116/ IS 1542. |
| 73 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 154 77, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).- Size 600x600 mm |
| 74 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints. |
| 75 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 ) kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.- Size 600x600 mm |
| 76 | Ornamental traditional brick masonry in mouldings and cornices (upto 50 cm in projection and 30 cm in depth as per traditional practice) in lime mortar similar to the existing traditional lime mortar 1:1:1 (1 lime: 1 coarse sand: 1 surkhi) after removing the damaged and out of plumb masonary from the vertical surfaces , as directed by Engineer incharge/ Architect, and including all leads, lifts and carriage. All complete. |
| 77 | Ornamental traditional brick masonry as per traditional practice in lime mortar similar to the existing traditional lime mortar 1:1:1 (1 lime: 1 coarse sand: 1 surkhi) after removing the damaged and out of plumb masonary from the vertical surfaces , as directed by Engineer incharge/ Architect, and including all leads, lifts and carriage. All complete. |
| 78 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement -All work up to plinth level- 1 :1.5:3 (1 cement : 1.5 coarse sand (zone-Ill} derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 79 | Reinforced cement concrete work in beams,wall, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources). |
| 80 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1 :1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 81 | Providing and Laying of Micro-concrete of M30 grade for structural strengthening work as per approved methodology for columns/beams and other structural members for all leads & depths including base preparation, conveying (manually / mechanically) for all leads & depth, placing in position, compaction by mechanical means, curing, levelling & finishing of top surface, staging & scaffolding for concreting excluding cost of reinforcement etc. Complete. Incase thickness exceeds 100mm aggregates not exceeding 10mm would be added in ratio 50% of weight of microconcrete as directed by Engineer incharge. (In case the damaged RCC area exceeds in thickness by 40mm). The material is approved make of \\"FOSROC\\" Renderoc RG(L) Density 2100 kg/cum or equivalent for the same. |
| 82 | Extraction of core cutting of 150/300 mm dia in slab/Wall ( 250 mm-450 mm deep) as per direction of structural engineer. |
| 83 | Polishing the existing terrazzo flooring by repairing the damaged portions with a 6–10 mm thick layer of marble chips (1 mm to 4 mm nominal size) laid in acement–marble powder mix in the ratio 3:1 by weight (3 parts cement : 1 part marble powder), using a proportion of 4:7 by volume (4 parts cement–marble powder mix : 7 parts marble chips), including applying cement slurry and completing all operations as per the direction of the Engineer-in-Charge. |
| 84 | 40 mm thick marble chips flooring, rubbed and polished to granolithic finish, under layer 28 mm thick cement concrete 1 :2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 12.5 mm nominal size) and top layer 12 mm thick with white, black, chocolate, grey yellow or green marble chips of sizes from 7 mm to 10 mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 2:3 (2 cement marble powder mix: 3 marble chips) by volume, including cement slurry etc. complete- Dark shade pigment with ordinary cement |
| 85 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 86 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 87 | Providing and applying deco paint in matt finish on new MS works, including Gate and Railings, complete as per manufacturer’s specifications and as directed by the Engineer-in-Charge. |
| 88 | Dismantling and shifting of existing DG set installed on ground floor, having approximate installation area 25 sqm and height up to 3.0 m, including disconnecting electrical/control connections, dismantling of DG set components wherever required, loading, unloading, shifting within the premises using suitable lifting arrangement such as hydra/crane, rigging tools and tackles, skilled manpower, stacking at designated location, complete as per site conditions and direction of Engineer-in- Charge. |
| 89 | Providing and constructing in position 600 x 600 x 600 depth size brick masonry water entrance chamber including 230mm thick brick masonry walls in cement mortar 1:4 cement plaster inside and outside in C.M 1:3 with waterproofing compund, 100 thick C.C M-15 cap on top, 1000 x1000 mm size MS frame and M.S. grating weight medium duty, etc complete |
| 90 | Providing & fixing FRP chamber cover (2.5T) with frame 600×600 mm complete with all fittings and fixing arrangements, including making good, as per direction of Engineer-in-Charge. |
| 91 | B. STRUCTURAL CONSOLIDATION & REPAIRSSupports for transferring the superimposed load, partially/fully, for RCC elements like column, beam, slab by providing adjustable steel telescopic props and bracing with C channel / Wooden Batten for uniform distribution of load and maintaining the same in position till required as directed by Engineer incharge. (1 prop covers 1.1 m x1.1 m area) |
| 92 | Repairing of 0.5 mm to 5 mm wide open joints/ cracks upto depth of 0.6 m in all types of masonry work including scraping of loose jointing material from cracks. The inner side to be filled/pointed with lime mortar with wooden trowel and fixing grouting nipple from outer side as directed by Architect. Then apply lime mortar by injection grouting through nozzle of compatible diameter through the pre fix nipple up to total thickness of existing wall and cut the PVC nipple pipe and grout with the material, lime mortar of mix lime & sand 1:1 mix with polymer using katha or other additives to achieve require matching colour and including cost of all materials, labour, machinery, equipment, curing and cleaning the site as directed. The fixing of Nozzles per nose 300mm centre to centre along the cracks. |
| 93 | Repairing of wide open joints/ cracks of width more than 10 mm wide and upto depth of 0.6 m in all types of masonry work including grouting for wall strenthening (such as filled the posrse area of wall joints mortar and increase the existing mortar life) by raking of loose external jointing material from cracks. The area to be drilled at equal intervals and fixing grouting nipple according to the grid finalized by the conservator. Then apply lime mortar by injection grouting through nozzle of compatible diameter through the pre fix nipple up to total thickness of existing wall and cut the PVC nipple pipe and grout with same material, lime mortar of mix lime & fine sand 1:1 mix with polymer using katha or other additives to achieve require matching colour and including cost of all materials, labour, machinery, equipment, curing and cleaning the site as directed. The fixing of nozzles arrangement for 1 sqm area in staggered patern in 300 mm c/c. |
| 94 | Steel reinforcement for R.C.C/RBC. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 95 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 96 | Stitching the cracks in brick/stone masonry by Stainless Steel bars of 6 mm Ø (304 grade) with length of 0.5 m on either sides after raking, cleaning and washing the cracks. The work execution as per direction or given methodlogy by Structural Engineer. |
| 97 | Gently cleaning of existing Str. Steel member manually/Mechanically as per EOI. |
| 98 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes |
| 99 | Applying priming coat:With ready mixed red oxide zinc chromate primer ofapproved brand and manufacture on steel galvanised iron/ steel works |
| 100 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 101 | Resuing of existing scrape/slavage wood (any size) available at site for timber rafters, purlins and purlin cleats hip rafters, jackrafters, ridges, wall plates, post plates and posts for roofing etc. after cleaning and repair. |
| 102 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In- Charge :- 50 mm average thickness |
| 103 | Tapping and removing the rusted sections of the steel and Providing and applying alkaline based Rust Remover coating on the rusted steel sections, repeat coating after 12 hours leave for 8hours after which wash with clean water so that all residue of the chemical is wash and cleaned after which the section is dry completely as per direction of Engineer in charge. |
| 104 | Providing and applying two coats of Rust passivator coating chemical on the cleaned and rust removed rebar sections ensuring 12 hour time gap between the two coats as per direction of Engineer in charge. |
| 105 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge.25 mm average thickness in 2 layers. |
| 106 | Repair and restoration of damaged profiles of carvings, cornices, mouldings, stringer courses and other architectural details by carefully removing the decayed portions and rebuilding the same in layers to accurately match the original profile, using lime mortar prepared with a mix of 1 kg lime to 3 kg fine sand, including the use of stainless steel armature pins of 6 mm diameter for proper bonding and anchorage, complete in all respects, as per the direction of the Engineer-in-Charge and in accordance with the detailed specifications laid down in the separate volume of specifications. |
| 107 | Providing and fixing in position MS iron gate / sliding door / double door / railing as per approved design, including all fixing arrangements such as rollers, guides, brackets, hinges, bolts, and other necessary hardware, complete as per the directionand approval of the Engineer-in-Charge. |
| 108 | Providing and fixing GRC railing for barricading the existing transformer, as per site requirement, including all fittings, fixing accessories and finishing as approved by the Engineer-in-Charge.Note: Foundation / civil works shall be measured and paid separately. |
| 109 | C. WATERPROOFING & ROOFING WORKRemoving the present treatment of waterproofing System (if any) given on the terraces and Each the sound surface below the present waterproofing system and cleaning the surface to Each the sound surface, remove all loose material with the help of tools and tackles from the surface and as well as from the hair line cracks & wide cracks if any.The Avg. thickness is 115mm. |
| 110 | Surface Repair: In case of pot holes/cracks, the same shall be repaired with lime grout using bonding agen of ratio 1:1 (1 lime:1 water:1 bonding agent) as per specificationed by manufacture/direction of Engineer incharge.Note:- Lime mortar( 1:1) to be prepared after proper slaking of lime (the name of kalli chuna from katni or Gotan) (minimum slaking period 15 days) . The mortar ratio is to be strictly followed as per the directions of the conservator.* Sand shall conform to IS 383/ IS 2116/ IS 1542.** The lime mortar used with bonding agent approved make of \\"FOSROC\\" Nitobond SBR-300 or equivalent as per mixing ration of manufacture or Conservator direction. |
| 111 | Providing and treating existing cracks/joints by cutting them in “V”-shape with cutter machine, cleaning, and filling with modified polyurethane elastomeric membrane/compound such as Sikalastic 450/560 of SIKA or approved equivalent. Applying additional PU membrane over the crack and embedding 11 GSM fibre mesh for reinforcement. Work to be done as per manufacturer’s specifications and as directed by the Design Architect. |
| 112 | Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.)-Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/RCC work. |
| 113 | Making khurras 45 x 45 cm with average minimum thickness of 10 cm lime concrete comprising of 1 Slaked lime: 1 sand: 2 brick aggregate (25mm nominal size) over PVC sheet 1 m x 1 m x 400 micron, finished with 12 mm lime plaster 1:2 (1 Slaked lime: 2 Coarse sand), rounding the edges and making and finishing the outlet complete.Note:- Lime Concrete (1:2) and lime mortar( 1:2) to be prepared after proper slaking of lime (the name of kalli chuna from katni or Gotan) (minimum slaking period 15 days). The mortar ratio is to be strictly followed as per the directions of the conservator.* Sand shall conform to IS 383/ IS 2116/ IS 1542. |
| 114 | Brick bat coba with Brick aggregate in superstructure up to two level: Lime mortar 1:1:1 (1 Lime putty: 1 surkhi: 1 coarse sand), upto 75 mm thick as per direction of Engineer-In-Charge.Note:- Lime mortar( 1:1:1) to be prepared after proper slaking of lime (the name of kalli chuna from katni or Gotan) (minimum slaking period 15 days) . The mortar ratio is to be strictly followed as per the directions of the conservator.* Sand shall conform to IS 383/ IS 2116/ IS 1542. |
| 115 | Lime concrete comprising of 1 Slaked lime: 2 sand: 4 brick aggregate (25mm nominal size) (above proportion can be used for flooring, foundation bed and roof).Note:- Lime concrete ( 1:2:4) to be prepared after proper slaking of lime (the name of kalli chuna from katni or Gotan) (minimum slaking period 15 days) . The mortar ratio is to be strictly followed as per the directions of the conservator.* Sand shall conform to IS 383/ IS 2116/ IS 1542. |
| 116 | Providing and applying bonding coat using SBR-based polymer such as Fosroc Nitobond SBR / Nitobond EP or equivalent products like Sika Latex / STP Shaliplast, prepared by mixing cement and SBR polymer in the ratio 1:1 (cement : SBR polymer) with the required quantity of water or as per manufacturer’s specifications to achieve a brushable consistency, and applying uniformly over the concrete surface with a brush, complete as per direction of the Engineer-in-Charge. |
| 117 | Providing and applying Polymer Modified Mortar (PMM) screed of 8–12 mm thickness, prepared in the proportion of Cement : Sand = 1:3, using an approved brand of SBR polymer dosed at 10–15% of the cement weight, thoroughly mixed to achieve a uniform consistency, laid and finished over the prepared surface, and cured for 24–48 hours to obtain a fully hardened surface, complete as per direction of the Engineer-in-Charge. |
| 118 | Providing and applying PU primer of approved brand such as Sika Primer-3N / Fosroc Primer 20 or equivalent, followed by the application of a PU waterproofing membrane such as Sika Sikalastic-450 / Fosroc Nitoproof 600 or equivalent systems, applied in 2–3 coats to achieve a total dry film thickness (DFT) of 1.2–1.5 mm, all in accordance with the manufacturer’s specifications and as directed by the Engineer-in- Charge. |
| 119 | Providing and Making Gola (Watta)in lime concrete comprising of 1 Slaked lime: 1 sand: 2 brick aggregate (25mm nominal size), along joints of wall and terrace finished with lime surkhi mortar 1:2 plaster of 15 mm thick single coat with gur, gugal, methi etc as per traditional practice in concave /approved shape of (size 75 mm x 75 mm). Note:- Lime Concrete ( 1:1:2) & lime surkhi mortar (1:2) to be prepared after proper slaking of lime (the name of kalli chuna from katni or Gotan) (minimum slaking period 15 days) . The mortar ratio is to be strictly followed as per the directions of the conservator.* Sand shall conform to IS 383/ IS 2116/ IS 1542. |
| 120 | Providing and fixing Cast Iron Pipes for drainage complete with fittings, bends, clamps, etc. including cutting and making good the walls, all complete.150 mm |
| 121 | Providing and fixing Cast Iron Pipes for drainage complete with fittings, bends, clamps, etc. including cutting and making good the walls, all complete.100 mm |
| 122 | Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). |
| 123 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). |
| 124 | Supplying and stacking of sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment) |
| 125 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 20 mm |
| 126 | Rough dressing the trenched ground including breaking clods. |
| 127 | Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. |
| 128 | Fine dressing of the ground. |
| 129 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 130 | Mixing earth and sludge or manure in the required proportion specified or directed by the officer-in-charge |
| 131 | Grassing with selection No. 1 Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying of good earth, if needed (the grass and good earth shall be paid separately). In rows 5 cm apart in both directions |
| 132 | Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying of good earth if needed.(The cost of sludge, manure and good earth shall be paid separately). |
| 133 | Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts. ICD No Description |
| 134 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, levelling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid separately). |
| 135 | Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded). |
| 136 | Plantation of Trees, Shrubs, Hedge, ground covers and seasonal plants at site i/c watering and removal of unsaverieable material’s as per direction of officer in charge(excluding cost of plant & water).Trees Plant |
| 137 | Plantation of Trees, Shrubs, Hedge, ground covers and seasonal plants at site i/c watering and removal of unsaverieable material’s as per direction of officer in charge(excluding cost of plant & water).Shurbs Plant |
| 138 | Plantation of Trees, Shrubs, Hedge, ground covers and seasonal plants at site i/c watering and removal of unsaverieable material’s as per direction of officer in charge(excluding cost of plant & water).Hedge Plant |
| 139 | Providing and Displaying of Duranta Golden plant, having ht.15 to 20 cm bushty shape plant with fresh and healthy leaves in 20 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.. |
| 140 | Providing and stacking of Caesalpinia pulcherrima species of height 45-60 cm. in earth |
| 141 | Providing and stacking of Allamanda violacea of height 30 cm to 45 cm. in poly bag of size 20 cm as per direction of the officer-in-charge. |
| 142 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 143 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: |
| 144 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re- rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 145 | Deduct for not rolling with power roller of minimum 8 tonnes for banking excavated earth in layers not exceeding 20 cm in depth. |
| 146 | 1 :2:4 (1 Cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 147 | Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20 mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10 mm wide filled with same mortar including ruled pointing ,approved pattern, etc. complete as per direction of engineer-in-charge. |
| 148 | Providing & fixing in position 65 mm thick factory made door frame of Phenol bonded Bamboo wood (superior class, interior use), in approved colour, texture and finish.The bamboo wood shall have minimum density of 1000 Kg/cum, minimum hardness 1000 Kgf. The door frame shall have tenon & mortise interlocking system, to be fixed to the wall with 100 mm size G.I screws all a complete as per direction of Engineer-in charge. |
| 149 | Providing, fabricating, supplying and installing signage of approved size, design, colour and material, including lettering, graphics, mounting framework, fixing accessories, surface preparation, alignment and final finishing, complete in all respects, as directed by the Engineer-in-Charge. |
| 150 | Iternal ElectrificationSWITCH CONTROL LIGHT POINTSWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 151 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 152 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 153 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 154 | Wiring for light/ power plug with 4X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.. |
| 155 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 156 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 157 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 158 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 159 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 160 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessedsteel/ PVC conduit as required.3 x 1.5 sq. mm |
| 161 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessedsteel/ PVC conduit as required.3 x 2.5 sq. mm |
| 162 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 163 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 164 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 165 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required.5/6 A switch |
| 166 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required.2 way 5/6 A switch |
| 167 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required.15/16 A switch |
| 168 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required.3 pin 5/6 A socket outlet |
| 169 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required.6 pin 15/16 A socket outlet |
| 170 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required.Telephone socket outlet |
| 171 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. |
| 172 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 173 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.asrequired1 or 2 Module (75mmX75mm) |
| 174 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.asrequired3 Module (100mmX75mm) |
| 175 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.asrequired6 Module (200mmX75mm) |
| 176 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.asrequired12 Module (200mmX150mm) |
| 177 | DISTRIBUTION BOARDSupplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door |
| 178 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)12 way (4 + 36), Double door |
| 179 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required.Single pole |
| 180 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required.Double pole |
| 181 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required.Triple pole and neutral |
| 182 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required63 A |
| 183 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete withconnections, testing and commissioning etc. as required. |
| 184 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 185 | SUB HEAD - III :Light FixturesSupply, installation testing and commissioning Linear suspended LED light fixture made of Wooden finishing with diffuser with opal and Prismatic diffuser with customised fixture finish suitable to support the heritage designing of Interior for indoor application with IP rating 40 with opal or prismatic diffuser, The fixture should have 50000hrs+ life with minimum @ L70B50. The LED light should have CRI 85+ with CREE Chip with CCT 3000K/4000K/6000K with diffused beam for proper spread of light, Luminaire should be of 20W having delivered lumen 4000-4500lm. The switching should be on/off.Make: Wipro/Lightup, BIPL ,Compect light, or Simillar (It will be procured after approval of PMC ) |
| 186 | Supply, installation testing and commissioning decorative wall light fixture made of terrace brass and glass for fixture finish suitaable for indoor application with IP rating 20 having double and single head which has LED Bulb Fitting of E27,E14,B22,B15 covered glass and opal diffuser as per the design, The fixture should have 50000hrs+ life with minimum @ L80B10. The LED light should have CRI 85+ with CREE Chip with CCT 3000K/4000K with diffused beam for proper spread of light, Luminaire should be of 10-20W having delivered lumen 2000-3000lm. The switching should be on/off.Make: kapoor lamp shades/Lightup, BIPL, Unilamp,Ikiru, RK Lite, Formalighting or Simillar (It will be procured after approval of PMC ) |
| 187 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuitprotection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. Recommended make - Philips, compact or similar- |
| 188 | Supply and fixing of LED surface mounted panel light of size 300×300 mm, 20/24 Watt, made of powder coated aluminium housing with opal diffuser, complete with electronic driver, PF >0.95, THD <20%, lumen efficacy ≥100 lm/W, CCT as required, including fixing accessories, wiring connection, testing and commissioning complete.ilar |
| 189 | Supply, installation testing and commissioning Tube lightLED1X20/22Watt, Integral i/c batten aluminiumbody, PC diffuser.t Make compact model no Marina - Tulip L-605 or simillar |
| 190 | UNINTERRUPTED POWER SUPPLYSupplying, installation, testing and commissioning of online 3 phase UPS system with 30 minutes back up including batteries, interconnecting cables, battery racks etc |
| 191 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speedcontrol and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 192 | Supply, Installation, Testing and Commissioning of heavy duty metal blade Exhaust Fan 300mm as per approved make ( havells Venttil - FHVVEMTDBB12- 1400 RPM, 70 watts or similar) |
| 193 | Providing and fixing chandelier of approved make. The rate is inclusive of all fixing arranegement.. (It will be procured after approval of Client requirement) |
| 194 | EXTERNAL WORKP/ F MV Danger Notice PlateProviding and fixing MV Danger Notice Plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides and with inscription in single red colour on front sideas required. |
| 195 | Providing and fixing HT danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides and with inscription in single red colour on front sideas required. |
| 196 | laying of one number PVC Insulated and PVC shethed /XLPE power Cables of 1.1 KV grade of following size direct in ground including excavation,sand cushioning and protecting covering and refillingthe trench etc as required.Up to 35 sq mm. |
| 197 | laying of one number PVC Insulated and PVC shethed /XLPE power Cables of 1.1 KV grade of following size direct in ground including excavation,sand cushioning and protecting covering and refillingthe trench etc as required.Above 35 sq mm and up to 95 sq mm. |
| 198 | Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications.3 x 2.5 sq. mm |
| 199 | Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications.3 x 4 sq. mm |
| 200 | Internal Electrification4 x 4 sq. mm |
| 201 | 4 x 6 sq. mm |
| 202 | 4 x 10 sq. mm |
| 203 | 4 x 16 sq. mm |
| 204 | XLPE Insulated Copper Armoured Cables2C x 6 Sq.mm. |
| 205 | 2C x 4 Sq.mm. |
| 206 | 3C x 6 Sq.mm. |
| 207 | Supplying & making of end terminations with brass compression gland and Al. lugs for following sizes of PVC insulated and PVC sheathed/ XLPE Al. conductor cable of 1.1 KV grade as required.4 x 10 sq. mm |
| 208 | Supplying & making of end terminations with brass compression gland and Al. lugs for following sizes of PVC insulated and PVC sheathed/ XLPE Al. conductor cable of 1.1 KV grade as required.4 x 16 sq. mm |
| 209 | S/ F powder coated of approved shade MS Cable TraysSupplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts,painting suspenders etc. as required..150 mm width X 50 mm depth X 1.6 mm thickness |
| 210 | S/ F powder coated of approved shade MS Cable Tray BendsSupplying and installing following size of perforated powder coated of approved shade M.S. cable tray bends with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 211 | S/ F powder coated of approved shade MS Cable Tray Tee'sSupplying and installing following size of perforated powder coated of approved shade M.S. cable tray tee's with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts &nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 212 | S/ F hot Galvanised of approved shade MS Cable Trays ( G.I) Tee'sSupplying and installing following size of perforated HOT dipped Galvanised iron M.S. cable \\" Tee\\"(Galvanised thiknes not les than 50 microns) bends with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling withM.S. suspenders including bolts & nuts, painting suspenders etc asrequired.100 mmm width X 50 mm depth X1.6 mm thickness |
| 213 | EARTHING SYSTEMProviding and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required. |
| 214 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 215 | Providing and fixing 25 mm X 5 mm copper strip on surface or inrecess for connections etc. as required. 2 nos used for 50 x 5 for the Neutral earthing of euipments ) |
| 216 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. |
| 217 | Supplying, fixing, testing and commissioning of following bare Copper/ GI flat including all necessary fixing accessories andeffecting connections.50 mm x 6 mm thick Cu flat |
| 218 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. asrequired. |
| 219 | Inground Uplighter -IP 66, 12W, 1512lm, 3000K, CRI 80, 24 Deg, Non-Dim |
| 220 | Driver For Uplighter |
| 221 | Surface Mounted Grazer -IP 65, 12W, 2400lm, 3000K, CRI 80, 24 Deg,Non-Dim L-1000mm |
| 222 | Power Supply For Grazer 150W, 24V, IP Rated |
| 223 | LED Strip With profile and Power Supply -IP 67, 10W/m, 980lm, CRI80, Diffused Optics, Non-Dim |
| 224 | DATA & CCTV4 pair shielded twisted pair (STP)Supplying and drawing 4 pair shielded twisted pair (STP),0.5 mm PVC insulated copper conductor un-armoured Cat-6 computer cable FRLS in existing surface/concealed, steel/PVC. conduit/ casing-n- capping as required.1 Run of cable |
| 225 | Supply & fixing of following sizes of medium class PVC conduit along with accessories in surface / recessed including cutting the wall & making good the same in caseof recessed conduit as required.25 mm dia. |
| 226 | Supply & fixing of following sizes of medium class PVC conduit along with accessories in surface / recessed including cutting the wall & making good the same in caseof recessed conduit as required.32 mm dia |
| 227 | Dome Camera CP-UNC-DA41L3C-D-LQ1/2.9\\" 4MP PS CMOS Image Sensor (0.8758 Centimeters) Max. 4MP (2688 × 1520)/ (2560 × 1440)@25/30 fps Instastream, H.265, H.264, H.264H, H.264B, MJPEGSupport Triple stream Support Built-in Mic3.6mm fixed LensWDR (120dB), Day/Night (ICR), 3D NR, ROI, AWB, AGC, BLC, HLC,IR Range of 30 Mtr., Warm Light Range of 30 Mtr., PoE, IP67MAKE:- CP PLUS,TP.LINK simillar |
| 228 | IP bullet cameraBullet Camera CP-UNC-TA41L6C-D-Q1/2.8\\" 4MP PS CMOS Image Sensor (0.9071 centimeters) Max. 4MP (2688 × 1520)@1-30fps/ 4MP (2560 × 1440)@1- 25/30Instastream, H.265, H.264, H.264H, H.264B, MJPEGSupport Triple streamWDR(120dB), Day/Night(ICR), 3D NR, AWB, AGC, BLC, HLC6mm Fixed Lens Support Built-in MicIR Range of 60 Mtr., IP67, PoEMake:- cp plus, TP.link,simillar |
| 229 | 32 channel NVR with 1080pSupply, Installation testing and commissioning Recommended make:TP-Link- VIGI NVR4064H VIGI 64 Channel Network Video Recorder64-Channel Live View and 4K HDMI Video OutputUp to 16-ch @ 2MP (25fps) / 8-ch @ 4MP (30fps) Decoding Capability16-Channel Synchronous Playback320 Mbps Incoming Bandwidth and 320 Mbps Outgoing Bandwidth4× SATA Interfaces and 1 Up to 16 TB* , H.265+ Compression TechnologyHDMI and VGA Simultaneous Output, Remote Monitoring.Make :- cp plus,tp link, d.link . Simillar |
| 230 | Hard diskProviding and Fixing of Seagate Skyhawk 8 TB Surveillance Internal Hard Drive HDD – 3.5 Inch SATA 6 Gb/s 256 MB Cache for DVR NVR Security Camera System with Drive Health Management (ST8000VX004) orsimmilar make8 TB |
| 231 | Supplying, installation, testing and commissioning of Jetstream TP-Link TL-SG3428MP | 24 Port Gigabit L2+ Managed PoE Switch | 384W | 4 SFP Slots | Auto Recovery | Omada SDN Support | IPv6, Static Routing make:- D.link, TP.link ,cp plus etc. Simillar24 port switch |
| 232 | Supplying and fixing RJ - 45 CAT 6 Patch Cable Speed Up to 1Gbps 23AWG/Upto 250Mhz, Bare Copper for, Router, Printer, SMART TVS,LAPTOPS,DESKTOPS ManualCrimbing(2 METER) etc. make :- honeywell ,D.link,Simillar2-Meter Patch Cord |
| 233 | Supply, installation testing and commissioning of 19\\" modular patch- D-Link Posiflex Cat6 Utp 24 Port Loaded Patch Panel/ Cat6 24 Port Panel. make :- honeywell,D.link, Simillar |
| 234 | Supply, installation testing and commissioning RJ - 45 computer jack cat 6 with shutter modular (2Module) etc.make :- honeywell ,D.link, Simillar |
| 235 | 5 Metre, HDMI cordhoneywell HDMI Cable v2.0 with ethernet, 3D/4K@60Hz ultra HD resolution, 5 mtr, 18GBPS Transmission Speed, high speed, compatible with all HDMI devices Laptop, Desktop, T.V. Set etc. make :- honeywell ,D.link, Simillar |
| 236 | 30U cabinetDynamic Rack 42U Rack Enclosures Networking/Server RackFor medium/large Networking telecom.CCTV, AV and Cable TV applications Made of 1.2mm high quality metal sheet1.6mm mounting angle wiht clear \\"U\\" marking Front with toughened glass, Real MS Door with lockRemovable side panels Cable entry provision at top & bottom2/4 Cooling fan fitting option at top Sufficient perforation provided for ventilation Finished with 7 process pre- treated powder coating Attractive color design- RAL- 7035 or blackPerforated front & rear doors also available Make -Dynamic Rack ,mass rack Simillar |
| 237 | Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for High density use having features and specifications etc. as mentioned here under- 802.11ax Wi-Fi 6, 2.6 Gbps wireless throughput, 2.5GbE uplink port, Poe or DC powered. SKU: FGINA7RPX5SZCategories: Networking Devices, Wireless Access Points Brand: ArubaApproved make- Aruba AP32/Instant On Wifi 6E Access point or similar |
| 238 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius :< 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required.1 Run of cable |
| 239 | Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. |
| 240 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete asrequired. |
| 241 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD)Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbersclosed cable organizer, Hardware mounting screwspacket of 20 x 1 number, etc. complete as required.6U Rack |
| 242 | Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. with the panel. |
| 243 | Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.Copper Patch Cords of length 1m (3ft) |
| 244 | Fire Detection & AlarmSupplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 245 | Supplying, installation, testing & commissioning of manualcall boxes of MS construction in surface/recess with stainlesssteel chain & hammer assembly complete with glass andpush button etc. as required. |
| 246 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 247 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete interconnections asrequired.4 ZONE |
| 248 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVCconduit as required.2 x 1.5 sq. mm |
| 249 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Single pair, 2-core, 1.5sqmm |
| 250 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit asrequired.25 mm |
| 251 | Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete asrequired. |
| 252 | Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required. |
| 253 | Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphoneassembly complete as required. |
| 254 | Supplying and installation of CO2 Type Fire Extinguisher 4.5 Kg Capacity made from seamless Cylinder Conforming to IS: 7285 duly approved by chief controller of Explosive, Nagpur fitted with ISI Marked controlled Valve conforming to IS : 3224, discharge adaptor with 1 mtr hose and PVC Bend horn complete with initial gas charged with carrying handle and wall mounting bracket Suitable for Operating between -30°C to +55°C IS:15683. Complete in all respect. |
| 255 | Supplying and installation of Mechanical Foam (Stored Pressure) Fire Extinguisher 9 Lt Capacity consisting of wielded cylinder, Squeeze lever discharge valve fitted with pressure indicate gauge, internal discharge tube, discharge nozzle suspension bracket, duly charged with ISI Marked Aqueous Film Forming Foam Forming to IS : 4989 and Pressurized with Nitrogen gas, Suitable for Operating between +5°C to +55°C IS : 15683. |
| 256 | HVACSplit AC floor mountedAC installation: - Installation of split type wall mounted air conditioner indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A, including connection of copper pipe and material supplied with complete unit etc as required. (excluding cost of copper pipe)1.8 ton |
| 257 | Split AC (non inverter) :-Supply installation testing and commissioning of split type floor mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A.Thecondensing unit working range should be capable of providing cooling between+/-5deg.Cto50deg.C required of cordless remote control, auto air swing louvers, wall stand for outdoor unit, connection copper lead wire, condense water outlet complete etc as required.Outdoor/indoor units should be of same make (brand).MODEL No :- 48CZMM .MAKE:- voltas, .blu star simillar4 ton |
| 258 | Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume aircooled Outdoor unit ssuitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller,topdischarge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required.The unit shall deliver the rated capacity a tAHRI Conditions and work evenat 50°C ambient temperature without tripping.The unit shall be suitable to work on 415 V+/-10%, 3Phase, 50Hz AC powersupply.The unit shall b efilled with first charge of the refrigerant and ready for use as required. MODEL No. -.MAKE:- voltas, daikin .blu star simillar10 |
| 259 | Supply, installation, testing and commissioning of following minimumcapacity VRV/VRF High wall type Indoor unit equipped with washable synthetic mediapre-filter, fan section with low noise fan/dynamically balanced blower, multi speed motor, coil section with DX copper coil,electronic expansion valve, oute rcabinet,cord less remotecontrol, drainpan, necessary accessoriesetc., suitable for operation on 230 V ± 10%, 50Hz, single phase AC supply, complete as required. The unit shall have automatic force shutdown provision in case of fire on receiving signal from BMS System.The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.MAKE:- voltas, daikin .blu star simillar1.8 ton |
| 260 | Supply, installation, testing and commissioning of following minimumcapacity VRV/VRF High wall type Indoor unit equipped with washable synthetic mediapre-filter, fan section with low noise fan/dynamically balanced blower, multi speed motor, coil section with DX copper coil,electronic expansion valve, oute rcabinet,cord less remotecontrol, drainpan, necessary accessoriesetc., suitable for operation on 230 V ± 10%, 50Hz, single phase AC supply, complete as required. The unit shall have automatic force shutdown provision in case of fire on receiving signal from BMS System.The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.MAKE:- voltas, daikin .blu star simillar2.5 ton |
| 261 | Copper pipeSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specificationsetc. as required :6.4mmdia(OD)(Softdrawn)with tubethickness1.2mmwith19mm thickinsulation |
| 262 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specificationsetc. as required :12.7mmdia(OD) (Softdrawn)with tubethickness1.2mmwith19 mmthick insulation |
| 263 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specificationsetc. as required :9.5mmdia(OD)(Softdrawn)with tubethickness1.2mmwith19mm thickinsulation |
| 264 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specificationsetc. as required :15.86mmdia(OD) (Softdrawn)with tubethickness1.2mmwith19 mmthick insulation |
| 265 | Cable traySupplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness |
| 266 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 267 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness |
| 268 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 269 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/PVC conduit as required.2 x 1.5 sq. mm |
| 270 | Supply of following sizes of XLPE insulated copper conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications.MAKE:- POLYCAB, HAVELLS.4c x 25 sq mm |
| 271 | Supply of following sizes of XLPE insulated copper conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications.MAKE:- POLYCAB, HAVELLS.4c x 16 sq mm |
| 272 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge.Dia 25 mm |
| 273 | Centralised Remote controllerCentral Remote Controller analog type with Technical Specifications suitable for automatic operation of all indoor and outdoorunits. |
| 274 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre longetc. with charcoal/ coke and salt as required. |
| 275 | Bills of Quantities - plumbingProviding and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the wallswherever required :Kitchen sink withdrain board510x1040 mm bowl depth 250 mm |
| 276 | Providing and fixing P.V.C. waste pipe for sink or wash basinincluding P.V.C. waste fittings complete.32 mm dia |
| 277 | Providing and fixing kitchen sink taps |
| 278 | Providing of below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation to bepaid seperataly.40 mm OD |
| 279 | Providing of below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation to bepaid seperataly.110 mm OD |
| 280 | Providing and fixing C.P. Brass Extension Nipple (1/2\\"x2\\" size)of approved quality conforming |
| 281 | Providing and fixing 100 mm sand cast Iron grating for gullytrap. |
| 282 | Water supply sytemProviding, fixing and testing CPVC pipes of an approved make complete with CPVC fittings such as tees, crosses, plugs, sockets, elbows, reducers, unions, sleeve pieces, check nuts etc. jointed with solvent cement compound including clamps/structural steel supports as required / directed at site including cutting and making good the walls, floors, RCC work etc. cutting chases and filling the same with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or cement mortar 1:4 (1 cement : 4 coarse sand) as required.(Vertical pipes for CWS & HWS)20mm nominal bore (SDR-11) |
| 283 | Providing, fixing and testing CPVC pipes of an approved make complete with CPVC fittings such as tees, crosses, plugs, sockets, elbows, reducers, unions, sleeve pieces, check nuts etc. jointed with solvent cement compound including clamps/structural steel supports as required / directed at site including cutting and making good the walls, floors, RCC work etc. cutting chases and filling the same with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or cement mortar 1:4 (1 cement : 4 coarse sand) as required.(Vertical pipes for CWS & HWS)25mm nominal bore (SDR-11) |
| 284 | Providing and fixing PPR UnionsPPR Union 25mm |
| 285 | Providing and fixing PPR UnionsPPR Union 20mm |
| 286 | Providing and fixing ball valve (brass) of approved quality,High or low pressure, with plastic floats complete :25 mm nominal bore |
| 287 | Geyser 3kw , 25 lt. Aproved make bajal/ V guard or equivalentwith glass lined.. |
| 288 | Aquaguard Aura RO+UV+UF+Taste Adjuster(MTDS) with Active Copper & Zinc 7L water purifier,8 stages of purification,suitable for borewell,tanker,municipal water(Black)from Eureka Forbes |
| 289 | Providing and fixing pillar tap mixer Single Lever Tall Boy with 150mm Extension Body Fixed Spout without Popup Waste System with 600mm Long Braided Hoses (model :- ORP- 10005BPM ) |
| 290 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 291 | well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction ofEngineer -in-charge.100 mm nominal size dia |
| 292 | well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction ofEngineer -in-charge.150 mm nominal size dia |
| 293 | GST Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail