Tender For Repair Maintenance Specialized Electrical & Mechanical Services Of Tis Hazari Court, Delhi. (Sh:- Annual Comprehensive Maintenance Of Cp Plus Make Cctv System Installed At Tis Hazari Court Complex.), Delhi-Delhi
TDR : 55766954
Tender Notice
BOQ
5 Days Left
Delhi
Delhi
Tender For repair maintenance Specialized Electrical & Mechanical Services Of Tis Hazari Court, Delhi. (Sh:- Annual Comprehensive Maintenance Of Cp Plus Make Cctv System Installed At Tis Hazari Court Complex.)
Name of Work:- R.M.O. Specialized Electrical & Mechanical Services of Tis Hazari Court, Delhi. (SH:- Annual Comprehensive Maintenance of CP Plus Make CCTV System Installed at Tis Hazari Court Complex.)
Sl. No.
Item Description
1
Providing annual comprehensive maintenance of following existing CP Plus make CCTV surveillance system (as mentioned below) consisting of CCTV cameras, NVR with racks and all other associated equipment’s etc. installed at Tis Hazari Court Complex, Delhi along with attending Breakdown complaints, periodical maintenance and repair etc. & periodical checking of entire system & replacement of worn out /faulty spare parts as per terms and conditions attached and as per the direction of Engineer-in-charge etc. as reqd.i) IP PTZ Camera - 2 Nos.ii) IP Dome Cameras - 36 Nos.iii) IP Bullet Cameras - 103 Nos.iv) NVR 32 Channel - 5 Nos.v) Work Station - 1 No.vi) 24 Port POE Switch - 9 Nos.
2
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.
3
a) 1 Run of cable
4
Supplying and drawing of UTP 4 pair CAT 6 armoured Cable in the existing surface/ recessed Steel/ PVC conduit as required.
5
a) 1 Run of cable
6
Supplying and drawing following core Multi mode Fiber Optic Cable having corrugated steel armoring, leser optimize 50/125 μm with HDPE jacket, LSZH (Low smoke Zero Halogen), Tight-buffered or loose tube, maximum attenuation: < 3.5 dB/km at 850 nm, < 1.5 dB/km at 1300 nm, bandwidth > 2000 MHz-km at 850 nm, > 500 MHz-km at 1300 nm compliance and certifications: ISO/IEC 11801 Ed. 2.2, ANSI/TIA-568- C.3, ITU-T G.651.1 RoHS compliant. Multi Mode Fiber shall be Central-loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793- 1/60794-1-2, ITU-T-REC G.652D and Telecordia GR- 20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature should be – 5 0C to +50 0C, Maximum Attenuation ± 3.5 dB/km at Operational Wavelength 850 nm and ± 1.5 dB / km at Operational Wavelength 1300 nm . type of fiber should be 50/125 / G.652D & Refractive Index should be 1.483/1.478, The value for Mode-filed,Cladding Diameter 50 ± 2.5 μm and 125 ± 1μm correspondingly i/c splicing & marking etc complete as required.a) 6 Core Multi Mode Optical Fiber Cable
7
Making provision of jointing and splicing of optical fiber cable (all core) inside LIU box including connection, testing & commissioning etc. complete as required. Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.