| 1 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and complete all as specified and as directed. |
| 2 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness including any pattern roof coverings complete all as specified and as directed. |
| 3 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. |
| 4 | Dismantling of wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness including cover fillets of any description including all snap grids and hanging arrangements complete all as specified. |
| 5 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, suitable for 75 / 110 mm Internal dia of pipe complete, all as specified and as directed by Engineer-in-charge at site. |
| 6 | Dismantling of wrought or mild steel work of any description such as in ladder work, bracing/supporting angle iron, roof top MS sheets, railings etc. complete all as specified and directed. |
| 7 | Taking down cement plaster, any description, on brick or stone walls, etc.including racking out joints, hacking for key, scrubbing down with water, etc. including removal of rubbish material away from site, complete all as specified and as directed. |
| 8 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer-in-charge at site. |
| 9 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.70 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering/ wall clading fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 10 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.70 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 11 | S&F suspended false ceiling using E-grid 2430 180 GSM (exposed ceiling suspension system) of grid size 600 mm x 600 mm with main runner 15mm x 32 mmx 0.30mm, cross tee 15mm x 32 mmx 0.30mm and wall angle 15 mm x 15 mm x 030mm using 4 mm thick Hihg pressure steam crude self textured design pre- primered Non asbestos fiber cement plain board (E board classic) in & including a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with steel dash fasteners or iron purlin form the roof with adjustment clip providing positions for light fixture air conditioning diffuser and ducts sprinkler smoke cetectores etc. the main runners to be secured to structura soffts by hanger @ 1220 mm maximum centre to centre the last hanger at the end of each main runner should not be placed at more than 450 mm from the adjucent wall flush fitting 1220 mm cross tee to be inter locked between main runners @ 610 mm centre to centre so as to form 600 mm x 600 mm grid complete all as specified and as directed. |
| 12 | M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 13 | M & L for cement concrete M15 (Nominal Mix) using 12.50 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed. |
| 14 | Material & labour for rendering 10 mm thick in cement mortar 1:3 over RCC Roof mixed with water proofing compound @ 3% by weight of cement or manufacturer instruction all as specified. (Note;- water proofing compound shall be measured and paid separately as supply only) |
| 15 | M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top: (i) Taking out old roof tratment and roughening tha same old concrete slab by picking, sweepingc clean and washing down with water to remove dust etc. (ii) Screed bed or bedding layer of mortar 15mm thick in CM 1:4 for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement (WPC shall be measured and paid seperately) (iii) Cleaning the plastered roof surface and applying one coat of cold bituminuous primer @ 0.30 ltr/Sqm confirming ti IS: 3384 -1986 (iv) APP based polymeric menbrane 3mm thick (minimum) weighing 3.5 kg/Sqm reinfiorced with polyster non woven fabric (weighing not less than 160gms/Sqm) shall be less appliedb over bituminous primer as specified above over a application of polymeric membrane shall by torch application. The overlaps shall be minimum 100mm on the teransverese direction and 75mm on longitudinal direction. (v) Applying one coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm. |
| 16 | Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and fair without using extra cement complete all as specified and as directed. |
| 17 | Material & labour for rendering 15 mm thick in cement mortar 1:4 over RCC Roof mixed with water proofing compound @ 3% by weight of cement or manufacturer instruction all as specified. (Note;- water proofing compound shall be measured and paid separately as supply only) |
| 18 | Supply only liquid water proofing compound complete all as specified and directed. |
| 19 | S&F PVC (SWR) Pipes single socketed in any length with rubber ring joints, 110 mm bore fixed to walls/floor, complete all as specified and as directed. |
| 20 | S&F in repairs PVC (SWR) bend with access door of 110mm bore complete all as specified. |
| 21 | Complete removal of existing treatment on wall/ roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour complete all as specified and directed. |
| 22 | M & L for 1 mm thick wall care putty on wall/ ceilings complete all as specified and as directed. |
| 23 | M & L for preparation of old surface of walls by washing, rubbing down and stopping of distempered and painted surfaces and applying two coat of oil bound distemper over one coat of suitable primer complete all as specified and as directed |
| 24 | M & L for preparation of new or previously untreated surfaces of wall and applying two coats of oil bound distemper over a coat of suitable primer complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 25 | M & L for preparation of new or previously untreated surfaces of wall and applying two coats of oil bound distemper over a coat of suitable primer complete all as specified and as directed. Please Enable Macros to View BoQ information |