Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Clearing jungle including uprooting of rank vegetations, grass,bush,wood trees and saplings of girth up to 30 cm. measured at a height of 1.00 M. above ground level and removal of rubbish up to a distance of 50.00M.Out side the peripheri of area cleared as per , SI No, DSR-2.3.1 |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m., SI No, 2.8.1 |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m., SI No, DSR-2.1.1 |
| 4 | Filling carted earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5m. DSR 2.25a, SI No, 2.25(a) |
| 5 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. DSR 2.27, SI No, 2.27 |
| 6 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment of soil along external perimeter of building 5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm. PWD CH 8 8.01, SI No, PWD Ambedkarnagar CH 8 |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) DSR 4.1.8, SI No, 4.1.8 |
| 8 | Providing, laying, spreading and compacting graded stone aggregate (sizerange 53 mm to 0.075 mm ) to wet mix macadam (WMM) specificationincluding premixing the material with water at OMC in for all leads & lifts,laying in uniform layers with mechanical paver finisher in sub- base / basecourse on well prepared surface and compacting with vibratory roller of8 to 10 tonne capacity to achievethe desired density, complete as perspecifications and directions of Engineer-in-Charge., SI No, (DSR- 16.79 |
| 9 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand (zone-lll) derived fromnatural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources): DSR 4.1.3, SI No, 4.1.3 |
| 10 | Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources), SI No, 5.1.2 |
| 11 | Supply & laying of 125micron polythene sheet under the foundation (for anti salt peter treatment ) over sub base to act as separation between sub base and conc. slab ( for CC road slab) including supply of material labour T &P etc required for proper completion of work., SI No, SOR CH 19 SI 4 |
| 12 | Centring and shuttering including strutting,propping etc. and removal of form for Foundations, footings, bases of columns etc. for mass concrete. DSR 5.9.1, SI No, 5.9.1 |
| 13 | Walls (any thickness) including attached pilasters. Butteresses, plinth and string courses etc. DSR 5.9.2, SI No, 5.9.2 |
| 14 | Lintels, beams, plinth bams, griders, bressumers and cantilevers. DSR 5.9.5, SI No, 5.9.5 |
| 15 | Columns,Pillars, Piers, Abutments, Posts and Struts. DSR 5.9.6, SI No, 5.9.6 |
| 16 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 5.22.6, SI No, 5.22.6 |
| 17 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M-25 grade with minimum cement content of 330 kg /cum DSR 5.33.1, SI No, 5.33.1.1 |
| 18 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) DSR -6.1.2, SI No, 6.1.2 |
| 19 | Providing & applying a coat of residual petroleum bitumen of gradeof VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. DSR 4.13, SI No, 4.13 |
| 20 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) DSR 4.1.3, SI No, 4.1.3 |
| 21 | Centring and shuttering including strutting,propping etc. and removal of form for Suspended floors, roots, landings, balcnies and access platform. DSR 5.9.3, SI No, 5.9.3 |
| 22 | Stairs, (excluding landings) except spiral-staircases. DSR 5.9.7, SI No, 5.9.7 |
| 23 | Edges of slabs and breaks in floors and walls Under 20 cm wide. DSR 5.9.16.1, SI No, 5.9.16.1 |
| 24 | Weather shade, Chajjas, corbels etc., including edges. DSR 5.9.19, SI No, 5.9.19 |
| 25 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). DSR 5.11.1, SI No, 5.11.1 |
| 26 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. DSR 5.33 All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.33.2.1, SI No, 5.33.2.1 |
| 27 | Add for using extra cement in the items of design mix over and above the specified cement content therein. DSR-5.35, SI No, 5.35 |
| 28 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 6.4.2, SI No, 6.4.2 |
| 29 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:4 (1 cement : 4 coarse sand), SI No, DSR-6.4.1 |
| 30 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) DSR 6.13.2, SI No, 6.13.2 |
| 31 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws DSR 9.21.1, SI No, 9.21.1 |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture including Applying priming coat with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. DSR 13.62.1+13.50.2, SI No, 13.62.1+ 13.50.2 |
| 33 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. DSR 9.121, SI No, 9.121 |
| 34 | 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. DSR 9.122.2, SI No, 9.122.2 |
| 35 | Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge. (Only for estimation), SI No, MR |
| 36 | Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge. (Only for estimation), SI No, MR |
| 37 | Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge. (Only for estimation), SI No, MR |
| 38 | Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge. (Only for estimation), SI No, MR |
| 39 | Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge. (Only for estimation), SI No, MR |
| 40 | Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/sqm) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The frame shall be filled with mineral wool Insulation having density minimum 96Kg/sqm . The frame will have a provision of G.I. anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with factory made template for SS ball bearing hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- Charge . (Cost of SS ball bearing hinges is excluded). DSR 9.161, SI No, 9.161 |
| 41 | Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes Fire rating conforming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/sqm) duly filled mineral wool insulation having density minimum 96 kg/cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-Charge (panelling to be paid for seperately). DSR 9.162, SI No, 9.162 |
| 42 | Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-Charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredited labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm. DSR 9.164, SI No, 9.164 |
| 43 | Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. DSR 9.139, SI No, 9.139 |
| 44 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces. DSR 10.5.1, SI No, 10.5.1 |
| 45 | Providing and fixing stainless steel (Grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). DSR 10.28, SI No, 10.28 |
| 46 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately), SI No, 10.14.2.2 |
| 47 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/masonry, etc. as per direction of Engineer-in-charge. 10 x 60 mm DSR 10.27.1, SI No, 10.27.1 |
| 48 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture including Applying priming coat with ready mixed aluminium primer of approved brand and manufacture on steel galvanised iron/ steel works. DSR 13.62.1+13.50.3, SI No, 13.62.1+ 13.50.3 |
| 49 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (by weight) DSR 9.48.1, SI No, DSR 9.48.1 |
| 50 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)( Z section windows) (by weight) DSR 10.11.1, SI No, DSR 10.11.1 |
| 51 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick DSR 11.26.1, SI No, 11.26.1 |
| 52 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. DSR 11.27, SI No, 11.27 |
| 53 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm DSR 11.41A.3.1, SI No, 11.41A.3.1 |
| 54 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 600 mm DSR 11.46.2, SI No, 11.46.2 |
| 55 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. DSR 11.37, SI No, 11.37 |
| 56 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. DSR 8.31, SI No, 8.31 |
| 57 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent DSR 11.56.1, SI No, 11.56.1 |
| 58 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. DSR 11.55.1, SI No, 11.55.1 |
| 59 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of Slab over 0.50sqm. DSR 8.2.2.2, SI No, 8.2.2.2 |
| 60 | Extra for providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work., SI No, 8.3.2 |
| 61 | Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete., SI No, 8.4 |
| 62 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete., SI No, 8.5 |
| 63 | 12mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) DSR 13.4.2, SI No, 13.4.2 |
| 64 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) DSR 13.5.2, SI No, 13.5.2 |
| 65 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 66 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR 13.80, SI No, 13.8 |
| 67 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre DSR 13.41.1, SI No, 13.41.1 |
| 68 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. DSR 13.45.1, SI No, 13.45.1 |
| 69 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. DSR 5.30, SI No, 5.3 |
| 70 | Providing and fixing 18mm thick gang saw cut Granite stone work for wall linin, backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1cement : 3 coarse sand) including pointing with white cement mortor with an admixture of pigment to match the granite shade complete as per direction of Engineer-in-charge., SI No, MR |
| 71 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :, SI No, 22.7 |
| 72 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
| 73 | (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65mm. DSR 22.7.1, SI No, 22.7.1 |
| 74 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. DSR 22.5, SI No, 22.5 |
| 75 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase DSR 12.21.1, SI No, 12.21 .1 |
| 76 | Providing & laying of light cinder filling/coil under floor of toilets & other sunken roofs., SI No, PWD Jhansi CH 11 New item 3 |
| 77 | Providing and laying Brick Bats in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge., SI No, MR |
| 78 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape,, SI No, 9.147A |
| 79 | colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : |
| 80 | Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded / mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. |
| 81 | Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. |
| 82 | Two track two panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system, adjustable nylon rollers with SS 304 body., SI No, 9.147.B1 |
| 83 | Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (74 mm & above). (Height upto 2.5 metre)., SI No, 9.147.B1.1 |
| 84 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes DSR 10.30.1, SI No, 10.30.1 |
| 85 | Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending, SI No, DSR 12.54.1 |
| 86 | Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement |
| 87 | and flexure in all directions including vertical displacement. The Joint system shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). |
| 88 | Wall Joint of 50 mm gap, SI No, MR |
| 89 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture as per Sl no. -13.62.1, SI No, 13.62.1 |
| 90 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone ) finished with floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. 40 mm thick floor 20 mm nominal size stone aggregate. As SI No. 11.3.1, SI No, 11.3.1 |
| 91 | Extra Cost for Lightening conductor, SI No, L.S. |
| 92 | Extra Cost for Inlet, outlet, overflow, washout and water meter gauge, SI No, L.S. |
| 93 | Cost of Distribution system, SI No, L.S. |
| 94 | ISMB 200 SECTION, SI No, DSR-10.1 |
| 95 | Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge. (Only for estimation), SI No, MR |
| 96 | Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge. (Only for estimation), SI No, MR |
| 97 | Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge. (Only for estimation), SI No, MR |
| 98 | Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge. (Only for estimation), SI No, MR |
| 99 | Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge. (Only for estimation), SI No, MR |
| 100 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand), SI No, DSR-13.5.1 |
| 101 | 18mm thick cement plaster in dado or skirting in 1:2 consisting of one part of cement and 2 parts of approved coarse sand laid in panels, finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 including supply of all materials, labour and T & P etc required for proper completion of the work., SI No, DSR-11.6.1 |
| 102 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors 40 mm wide and 4 mm thick., SI No, DSR-11.13.1 |
| 103 | 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall., SI No, DSR-13.9.1 |
| 104 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer- in- Charge., SI No, (DSR-16.78.2) |
| 105 | Providing, laying, spreading and compacting graded stone aggregate (sizerange 53 mm to 0.075 mm ) to wet mix macadam (WMM) specificationincluding premixing the material with water at OMC in for all leads & lifts,laying in uniform layers with mechanical paver finisher in sub- base / basecourse on well prepared surface and compacting with vibratory roller of8 to 10 tonne capacity to achievethe desired density, complete as perspecifications and directions of Engineer-in-Charge., SI No, (DSR- 16.79) |
| 106 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer- in- charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Cement concrete prepared with batch mixing machine., SI No, (DSR-16.43.1) |
| 107 | Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. |
| 108 | Providing and filling in position rubberized bitumen hot sealingcompound for sealing of expansion joints in roads / pavementsall complete as per direction of the Engineer-in-Charge (DSR- 16.46.1), SI No, 16.46.1 |
| 109 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 40X40X5 mm, joints mitred and welded by angle iron 40X40X5 mm or 40x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. (by weight) DSR 10.31, SI No, DSR 10.31 |
| 110 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq. mm with tape (0.52 mm thick) and weight 43.478 gm/ metre(cost of M.S. angle, C.C. blocks shall be paid separately)B51, SI No, DSR 16.53 |
| 111 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)., SI No, DSR-13.47.1 |
| 112 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). DSR 9.53, SI No, DSR 9.53 |
| 113 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources), SI No, 4.2.3 |
| 114 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete., SI No, 14.34 |
| 115 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm, SI No, 9.62.2 |
| 116 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :(a) 250 mm x 10mm, SI No, 9.63.1 |
| 117 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm, SI No, 9.66.1 |
| 118 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture, SI No, DSR 13.48.3 |
| 119 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tube, SI No, 10.16.1 |
| 120 | Providing & fixing Acrylic Sign board complete in all respects., SI No, M.R. |
| 121 | Providing & Laying 80mm dia. G.I pipe, SI No, 1552 |
| 122 | M.S. Flate & welding etc., SI No, M.R |
| 123 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall., SI No, 13.1 |
| 124 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: |
| 125 | (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
| 126 | (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 127 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. |
| 128 | (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
| 129 | (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: With average thickness of 120 mm and minimum thickness at khurra as 65 mm., SI No, DSR-22.7.1 |
| 130 | 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws decorative type, SI No, DSR-9.20.2 |
| 131 | 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws, SI No, DSR-9.21.2 |
| 132 | P&F of M.S. rectengular double rebated hollow pipe 120x60x3 mm section door frame with 4 nos. ISI hinges single leaf and 8 nos. ISI hinges in double leaf door., SI No, DSR-10.15.1 |
| 133 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood, SI No, DSR-9.1.1 |
| 134 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 12 mm mild steel U beading, SI No, DSR-9.135.2 |
| 135 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Second class teak wood, SI No, DSR-9.27.2.1.1 |
| 136 | 12mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) DSR 13.4.1, SI No, DSR-13.4.1 |
| 137 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete ( Size of Tile 600x600 mm), SI No, DSR-11.41.2 |
| 138 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : |
| 139 | (a) 200 mm x 10mm, SI No, DSR-9.63.2 |
| 140 | (a) 150 mm x 10mm, SI No, DSR-9.63.3 |
| 141 | Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :25 mm dia, SI No, DSR-9.46.3 |
| 142 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (a) Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only, SI No, DSR-9.21.3 |
| 143 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to 1S: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover, SI No, DSR-10.6.1 |
| 144 | Providing and fixing ball bearing for rolling shutters., SI No, DSR-10.7 |
| 145 | Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of, SI No, DSR-22.6 |
| 146 | Providing & laying of light cinder filling under floor of toilets & other sunken roofs., SI No, (M.R.) |
| 147 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge., SI No, DSR-10.28 |
| 148 | Providing & fixing on wall face PVC vent pipes including jointing with seal ring. |
| 149 | a) 110mm dia PVC pipe., SI No, 12.41.2 |
| 150 | b) 75mm dia PVC pipe., SI No, 12.41.1 |
| 151 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. [DSR-16.91.2], SI No, [DSR-16.91.2] |
| 152 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).. [DSR-16.69], SI No, [DSR-16.69] |
| 153 | Supply & laying of 125micron polythene sheet under the foundation (for anti salt peter treatment ) over sub base to act as separation between sub base and conc. slab ( for CC road slab) including supply of material labour T &P etc required for proper completion of work., SI No, SOR CH 19 SI 4 |
| 154 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:, SI No, 19.15 |
| 155 | With 20x20mm square bar, SI No, 19.15.1 |
| 156 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 157 | M.D. -10- Circular shape 500mm internal diameter, SI No, 19.19.2.2 |
| 158 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level., SI No, 23.2 |
| 159 | Drilling of 300mm dia bore hole manually., SI No, 23.2.1.1 |
| 160 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge., SI No, 23.4 |
| 161 | 150 mm nominal size dia, SI No, 23.4.2 |
| 162 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge., SI No, 23.5 |
| 163 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge., SI No, 23.6 |
| 164 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge., SI No, 23.7 |
| 165 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge., SI No, 23.8 |
| 166 | 40 mm : 15% of the entire volume (15%) |
| 167 | 20 mm : 50% of the entire volume (50%) |
| 168 | 45-63 mm : 35% of the entire volume (35%) |
| 169 | COST OF TECHNICAL WORK 75 KLD STP, SI No, M .R. |
| 170 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire, SI No, 1.14.6 |
| 171 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required., SI No, 1.57 |
| 172 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes., SI No, 1.51 |
| 173 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) 16 way Double door, SI No, 2.3.4 |
| 174 | Providing and fixing 600 x 450mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete in all respect., SI No, 17.31 |
| 175 | Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore, SI No, 18.17.1 |
| 176 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank., SI No, DSR 18.48 |
| 177 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. |
| 178 | 150 mm. dia. RCC Pipes, SI No, 43618 |
| 179 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipesincluding bed concrete as per standard design |
| 180 | 150 mm. dia. |
| 181 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cementm concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20 mm nominal size) as per standard design :, SI No, 19.15.1 |
| 182 | Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directedwithin a lead of 50m. |
| 183 | 1.50 m depth |
| 184 | Pipes 80 mm to 300 mm diameter, SI No, 2.10.1 |
| 185 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe withcollars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. |
| 186 | 150 mm. dia. RCC Pipes, SI No, 43618 |
| 187 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
| 188 | 150 mm. dia., SI No, 43526 |
| 189 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5, SI No, 19.9.1.1 |
| 190 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cementm concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :, SI No, 19.15.1 |
| 191 | Providing and fixing Square- mouth SW gully trap class SP-1 Complete with CI Grating brick masonry chamber with water tight CI Cover with frame of 300 X 300mm size (inside) the weight of cover to be not less than 4.50kg and frame to be not less than 2.70kg as per standard design., SI No, 19.4 |
| 192 | 100 x 100 mm size P type, SI No, 43556 |
| 193 | with common burnt clay F.P.S(non modular) brick of class designation 7.5, SI No, 19.4.1.1 |
| 194 | 11 KV DOUBLE POLE STRUCTURE |
| 195 | Supply, erection, testing and commissioning of 2 pole structure for providing 1 No. 11KV,200A GOS in accordance with IE rules, & local authority specification and drawings and comprising of the following. |
| 196 | a. 2 Nos. 11 mtr. long MS STEEL poles complete with, pole excavation, MS STEEL foundation, and back filling complete MS steel channel/angle iron etc. |
| 197 | b. 1 Set of cross arms, branching, clamps and painting complete with GI nut, bolts & washers as required (for GO & DO), LA connection. |
| 198 | c .1 set 11KV Insulator complete with spindles & hardware complete as required. |
| 199 | d .1 No. 11KV 400A TP Gang operated Air break switches complete with 25mm dia GI pipe operating machanism, handle & locking arrangement. |
| 200 | e. 1 set of 3 nos.11KV single pole drop out fuse complete with barrel fuses, and mounting arrangement. |
| 201 | f. 1 set (3 nos.) 11KV lightning arrestor and connecting to all phases. |
| 202 | g. 1 No. 150 mm dia GI pipe class 'B' (for XLPE cable protection) as required. |
| 203 | h. 2 Set 50mm dia 3m long GI pipe earting with 25 x 6 mm GI earth strip complete as required (for GO & DO & LA) |
| 204 | i 1 nos. 11KV HT danger boards and 2 set of anticlimbing devices. |
| 205 | 11 KV Double Pole Structure |
| 206 | ELECTRICAL WORK |
| 207 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C, SI No, 1.10.3 |
| 208 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required., SI No, 1.11 |
| 209 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C, SI No, 1.55.3 |
| 210 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire, SI No, 1.14.3 |
| 211 | Wiring for light/ Power plug with 2X4 sq. mm FRLS PVC insuleted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 Nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required., SI No, 1.12 |
| 212 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire, SI No, 1.14.5 |
| 213 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 x 16 sq.mm. + 2 x 6 sq.mm. earth wire, SI No, 1.14.11 |
| 214 | Supply and wiring of 4 numbers, 25 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 50 mm dia heavy guage rigid steel couduit on surface, with 2 nos 10 SWG copper earth continuity wire etc, complete in all respect, SI No, UPPWD 270B |
| 215 | Add for Invertor Wiring in wiring Point for light/ Fan/ Plugwith 1.5 mm Cu Wire, SI No, UPPWD 189 A |
| 216 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required., SI No, 1.26 |
| 217 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 5/6 amps switch, SI No, 1.24.1 |
| 218 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 2 Way 5/6 amps switch, SI No, 1.24.2 |
| 219 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 3 pin 5/6 amp socket outlet, SI No, 1.24.4 |
| 220 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 6 pin 15/16 amp socket outlet, SI No, 1.24.5 |
| 221 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required., SI No, 1.38 |
| 222 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., SI No, 1.24 |
| 223 | TV Antenna socket outlet, SI No, 1.24.7 |
| 224 | Telephone socket outlet, SI No, 1.24.6 |
| 225 | Supplying and drawing 4 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required., SI No, 1.18.3 |
| 226 | Supply & fixing of following white RJ 45 cat 6 data outlet / information outlet ETL verified to meet exceed TIA / ETA (Only for estimation), SI No, MR |
| 227 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required., SI No, 1.19 |
| 228 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm), SI No, 1.27.1 |
| 229 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm Dia, SI No, 1.21.2 |
| 230 | 40 mm dia G.I Pipe (Medium class), SI No, DSR 1549 |
| 231 | Supply & Installation of Safety Signage (Only for estimation), SI No, MR |
| 232 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required., SI No, 9.1.3 |
| 233 | Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work., SI No, DSR Civil 2023 10.18 |
| 234 | Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housingwith heat sink, diffuser/ Reflector and driver set complete in all respect. CAT AA, SI No, UPPWD 1401 |
| 235 | CAT AAA |
| 236 | Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. CAT AAA, SI No, UPPWD 1413A |
| 237 | Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect CAT AA, SI No, UPPWD 1417 |
| 238 | Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. CAT-AAA, SI No, UPPWD 1406 |
| 239 | Supplying and fixing PVC batten/ angle holder including connections etc. as required., SI No, 1.34 |
| 240 | Installation ,Testing, Commissioning of wall bracket /ceilingfittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required., SI No, 1.35 |
| 241 | Supply and fixing of Mirror Light 10 Watt LED . complete in all respect (only for estimation) (Only for estimation), SI No, MR |
| 242 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep, SI No, 1.50.1 |
| 243 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes., SI No, 1.51 |
| 244 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator), SI No, 2.4 |
| 245 | 4 way (4 + 12), Double door, SI No, 2.4.1 |
| 246 | 8 way (4 + 24), Double door, SI No, 2.4.3 |
| 247 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole, SI No, 2.10.1 |
| 248 | Supplying and fixing of 63 Amp. 4 pole MCB(10 KA) C Curve CAT A, SI No, UPPWD 1020A |
| 249 | Supplying and fixing of 40 Amp. 4 pole MCB (10 KA) CAT A, SI No, UPPWD 1020 |
| 250 | Supplying and fixin of 40 Amp. DP MCB (10 KA) C Curve CAT A, SI No, UPPWD 1010 |
| 251 | Supplying and fixing of 63 Amp. DP MCB (10 KA) CAT A, SI No, UPPWD 1011 |
| 252 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required., SI No, 2.11 |
| 253 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified., SI No, UPPWD 725 (B.) |
| 254 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required., SI No, 5.15 |
| 255 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30cm square C.I. frame with hinged cover & masonry housing.Make: As approved in U.P. P.W.D., & C.P.R.I. Certified., SI No, UPPWD 725 (B.) |
| 256 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required., SI No, 6.2 |
| 257 | Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required., SI No, 6.3 |
| 258 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor and external lighting complete as required. (For Horizontal run), SI No, 6.7 |
| 259 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run), SI No, 6.8 |
| 260 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required., SI No, 6.12 |
| 261 | LT PANEL |
| 262 | Design, Supply, installation, testing and commissioning of indoor/outdoor floor mounted/ wall mounted, IP43/IP65, IEC 61439/IS 8623, factory built, modular, sectionalised, compartmentalized, extendable type HT/LT cubicle panel of suitable size suitable for operation on 33/11/0.433/0.415 kV, 50 Hz AC 3 phase supply system fabricated from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process or better before painting for surface treatment and powder coated in approved shade, with suitable electrolytic grade high conductivity bus bars extensible, DMC/ SMC (whichever is superior) bus bar supports, with short circuit withstand capacity as mentioned ,bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm. PVC insulated FRLS copper conductor S/C cable for voltage & current respectively, including providing and fixing following switch gears as per SLD ,technical specifications etc.complete in all respect so as to fulfill all as required. .(Only for estimation), SI No, MR |
| 263 | The minimum clearances between bus bars shall be as follows : |
| 264 | Phase to phase - minimum 20mm |
| 265 | Phase to neutral-minimum 15mm |
| 266 | Incoming : |
| 267 | 1Nos 500 Amp. 4P MCCB of 36kA Breaking capacity |
| 268 | Metering : |
| 269 | 1 Set of CT's one of 500/ 5Amp ratio for Multifunction Meter |
| 270 | 1 Nos. Set of Phase Indication Lamp. |
| 271 | 1 Nos. of class-III Type SPD |
| 272 | Bus Bar : |
| 273 | 600 Amp.TPN aluminimum bus bar of suitable length.50KA |
| 274 | Outgoing : |
| 275 | Phase indication lamps on each outgoing to be provided. |
| 276 | 1 No.63 Amp 4P MCCB. (10 KA) |
| 277 | 40 No.40 Amp 4P MCB. (10 KA) |
| 278 | 5 No.40 Amp 2P MCB. (10 KA) |
| 279 | Panel described as above with 2 Years comprihensive waranty. ., SI No, MR |
| 280 | Fire Panel |
| 281 | Incoming : |
| 282 | 01 No. 100 Amp 4P MCCB. (36 KA) |
| 283 | 01 No. 100 Amp 4P ATS |
| 284 | Metering : |
| 285 | 1 Set of CT's one of 250/ 5Amp ratio for Multifunction Meter |
| 286 | 1 Set of CT's one of 250/ 5Amp ratio 50/51 |
| 287 | 1 Nos. Set of Phase Indication Lamp. |
| 288 | 1 Nos. of class-III Type SPD |
| 289 | Bus Bar : |
| 290 | 1 Set of 80 Amps TP Aluminium Bus Bars |
| 291 | Outgoing : |
| 292 | Phase indication lamps on each outgoing to be provided. |
| 293 | 02 No.63 Amp 3P MCCB. (25 KA) |
| 294 | 01 No.40 Amp 3P MCCB. (25 KA) |
| 295 | Panel described as above and with three years AMC & Comprihensive waranty (Only for estimation), SI No, MR |
| 296 | Fire Panel |
| 297 | Incoming : |
| 298 | 01 No. 250 Amp 4P MCCB. (36 KA) |
| 299 | 01 No. 250 Amp 4P ATS |
| 300 | Metering : |
| 301 | 1 Set of CT's one of 250/ 5Amp ratio for Multifunction Meter |
| 302 | 1 Set of CT's one of 250/ 5Amp ratio 50/51 |
| 303 | 1 Nos. Set of Phase Indication Lamp. |
| 304 | 1 Nos. of class-III Type SPD |
| 305 | Bus Bar : |
| 306 | 1 Set of 80 Amps TP Aluminium Bus Bars |
| 307 | Outgoing : |
| 308 | Phase indication lamps on each outgoing to be provided. |
| 309 | 02 No.125 Amp 3P MCCB. (25 KA) |
| 310 | 01 No.80 Amp 3P MCCB. (25 KA) |
| 311 | Panel described as above and with three years AMC & Comprihensive waranty (Only for estimation), SI No, MR |
| 312 | Plumbing Panel |
| 313 | Incoming : |
| 314 | 01 No. 100 Amp 4P MCCB. (25 KA) |
| 315 | 01 No. 100 Amp 4P ATS |
| 316 | Metering : |
| 317 | 1 Set of CT's one of 100/ 5Amp ratio for Multifunction Meter |
| 318 | 1 Set of CT's one of 100/ 5Amp ratio 50/51 |
| 319 | 1 Nos. Set of Phase Indication Lamp. |
| 320 | 1 Nos. of class-III Type SPD |
| 321 | Bus Bar : |
| 322 | 1 Set of 200 Amps TP Aluminium Bus Bars |
| 323 | Outgoing : |
| 324 | Phase indication lamps on each outgoing to be provided. |
| 325 | 03 No.63 Amp 3P MCCB. (25 KA) |
| 326 | 02 No.40 Amp 3P MCCB. (25 KA) |
| 327 | 01 No. 25 Amp 3P MCCB. (25 KA) |
| 328 | 01 No.63 Amp DP MCB. (10 KA) |
| 329 | Starter As per Type 2 & Pump Rating |
| 330 | Panel described as above and with three years AMC & Comprihensive waranty. (Only for estimation), SI No, MR |
| 331 | Fire Suppression System - CQRS Direct |
| 332 | Tube Based Fire Suppression System - CQRS Direct - Low Pressure HCFC 123 - 4KG Panel described as above and with three years AMC & Comprihensive waranty . (Only for estimation), SI No, MR |
| 333 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C, SI No, 1.3.3 |
| 334 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required., SI No, 1.25 |
| 335 | SITC of 20W LED batten with Microwave motion technology for providing an energy-efficient solution and with aluminum housing & integrated electronic driver complete in all respect., SI No, M.R. |
| 336 | Miscellaneous Items : |
| 337 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work., SI No, Civil 10.18 |
| 338 | PLUMBING WORK |
| 339 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid, SI No, 17.3.1 |
| 340 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 610x460 mm bowl depth 200 mm, SI No, 17.1 |
| 341 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer, SI No, 17.7A |
| 342 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia, SI No, 17.28.1.2 |
| 343 | Providing and fixing CP Brass 32mm/40mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge., SI No, 17.22A |
| 344 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (For bath) 15 mm nominal bore, SI No, 17.22.B |
| 345 | Providing and fixing 600 x 450mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete in all respect., SI No, 17.31 |
| 346 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms, SI No, 17.73.1 |
| 347 | Providing and fixing C.P. brass shower rose with 15 or 20mm inlet 150 mm diameter, SI No, 18.22.2 |
| 348 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore, SI No, 18.49.1 |
| 349 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore 15 mm nominal bore, SI No, 18.51.1 |
| 350 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore, SI No, 18.52.1 |
| 351 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore, SI No, 18.53.1 |
| 352 | Providing & fixing storage type electric hot water heater 25 Litre made out of heavy gauge steel jacket finished with rust proof baked-on glossy white enamel paint, inside glass lined heavy gauge copper tank, 25 mm thick polyurethane foam insulation, thermostatically controlled immersion heater with pilot neon lamp, replaceable magnesium anode bar, suitable for 8.0 bar maximum working pressure, cold water inlet and hot water outlet pipe, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. (Horizontal/Vertical) (only for estimation), SI No, MR |
| 353 | Providing & fixing C.P. hand spray with lever control (health faucet) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects. (Angle valve to be provide under item no. 18 and measure with that item.) (only for estimation), SI No, MR |
| 354 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarsesand : 10 graded stone aggregate 40 mm nominal size) all-roundS.W. pipes including bed concrete as per standard design : 100 mm dia, SI No, 19.2.1 |
| 355 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm dia, SI No, 12.41.2 |
| 356 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Coupler 110 mm, SI No, 12.42.1.2 |
| 357 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Single tee with door 110x110x110 mm, SI No, 12.42.3.2 |
| 358 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Single tee without door 110x110x110 mm, SI No, 12.42.4.2 |
| 359 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110mm bend, SI No, 12.42.5.2 |
| 360 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Shoe (Plain) 110mm shoe, SI No, 12.42.6.2 |
| 361 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams., SI No, 12.44 |
| 362 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete., SI No, 12.22 |
| 363 | Cutting holes up to 30x30 cm in walls including making good the same: With With common burnt clay F.P.S. (non modular) bricks, SI No, 18.76 |
| 364 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof, SI No, 18.77 |
| 365 | Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. 110 mm dia. (only for estimation), SI No, MR |
| 366 | Providing and fixing SWR PVC trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 110mm x 110mmX110mm (only for estimation), SI No, MR |
| 367 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Bend without door (45°) 110mm (only for estimation), SI No, MR |
| 368 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Y' Fitting without door 110mm (only for estimation), SI No, MR |
| 369 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Single Tee without door 110mm (only for estimation), SI No, MR |
| 370 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Coupler 110mm (only for estimation), SI No, MR |
| 371 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Clean Out Plug 110mm (only for estimation), SI No, MR |
| 372 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Vent Cowl 110mm (only for estimation), SI No, MR |
| 373 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal 50mm dia. Pipe (only for estimation), SI No, MR |
| 374 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc 40mm dia. Pipe (for wash basin & sunken toilet spout) (only for estimation), SI No, MR |
| 375 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . Elbow (90°) 40mm (only for estimation), SI No, MR |
| 376 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . Elbow (45°) 40mm (only for estimation), SI No, MR |
| 377 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . T fitting 40mm (only for estimation), SI No, MR |
| 378 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . Coupler 40mm (only for estimation), SI No, MR |
| 379 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . Elbow (45°) 32mm (only for estimation), SI No, MR |
| 380 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . T fitting 32mm (only for estimation), SI No, MR |
| 381 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . Coupler 32mm (only for estimation), SI No, MR |
| 382 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . Elbow (90°) 32mm (only for estimation), SI No, MR |
| 383 | Supply and fixing of UPVC S.W.R. pipe Nahni Trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali., SI No, MR |
| 384 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia nominal bore, SI No, 18.8.1 |
| 385 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm dia nominal bore, SI No, 18.8.2 |
| 386 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 15 mm dia nominal bore, SI No, 18.7.1 |
| 387 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 20 mm dia nominal bore, SI No, 18.7.2 |
| 388 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 32 mm dia nominal bore, SI No, 18.7.4 |
| 389 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 40 mm dia nominal bore, SI No, 18.7.5 |
| 390 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : . 20mm dia nominal bore, SI No, 18.17.1A |
| 391 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25mm dia nominal bore, SI No, 18.18.3 |
| 392 | Providing and fixing gun metal gate valve with wheel of approved quality. 32mm dia nominal bore, SI No, 18.17.2 |
| 393 | Providing and fixing gun metal gate valve with wheel of approved quality. 40mm dia nominal bore, SI No, 18.17.3 |
| 394 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required Single headed Gunmetal, SI No, 27.9.1 |
| 395 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal, SI No, 27.16.1 |
| 396 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling asrequired : Gun metal, SI No, 27.18.1 |
| 397 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket 40M, SI No, 27.17.2 |
| 398 | Supplying, installation, testing and commissioning of weather proof M.S door and glass fire door size 2100 mm x 900mm fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the following: - (only for estimation), SI No, MR |
| 399 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe, SI No, 27.19.1 |
| 400 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way-150 mm dia M.S. Pipe, SI No, 27.19.2 |
| 401 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia, SI No, 27.7.7 |
| 402 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 65 mm dia, SI No, 27.7.5 |
| 403 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 100 mm dia (only for estimation), SI No, MR |
| 404 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 65 mm dia, SI No, 27.11.3 |
| 405 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 100 mm dia, SI No, 27.11.5 |
| 406 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 100 mm dia, SI No, 27.14.5 |
| 407 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 65 mm dia, SI No, 27.14.3 |
| 408 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required., SI No, 27.13 |
| 409 | Supply, Installation, Testing and Commissioning of 100/150 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0 - 16 Kg / cm2 ., SI No, MR |
| 410 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange 100 mm dia, SI No, 27.15.2 |
| 411 | Supplying and Fixing of Fire Man's axe with heavy insulated rubber as per standard conforming to IS 926., SI No, MR |
| 412 | Providing & fixing double flanged Metallic expansion with M.S. fixed flanges (PN-1.6) joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required as per specifications. 150 mm dia, SI No, MR |
| 413 | Providing & fixing double flanged Metallic expansion with M.S. fixed flanges (PN-1.6) joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required as per specifications. 80 mm dia, SI No, MR |
| 414 | Providing & fixing Flow switch in folowing sizes M.S. pipe including connection ETC. as required. 100mm dia, SI No, 27.23.1 |
| 415 | upplying, installation, testing and commissioning of electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required: Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325 M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 450 lpm at 35m Head., SI No, 27.4.2 |
| 416 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completionof work, SI No, UPPWD 1132 |
| 417 | Supply and fixing of fire extinguisher, ABC Type 4.00kg. capacity (ISI Marked IS : 15683 & TAC approved)complete with initial charge and wall bracket, along withsupply of all materials and labour for proper completionof work., SI No, UPPWD 1131 |
| 418 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required- 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visua indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set. 6 zone panel, SI No, 17.1.11 |
| 419 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required., SI No, 17.1.2 |
| 420 | Supplying, installation, testing & commissioning of heat detector operating at 54C/57C with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required., SI No, 17.1.1 |
| 421 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required., SI No, 17.1.3 |
| 422 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operationwith amplifier i/c line matching transformer etc. complete as required., SI No, 17.1.6 |
| 423 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable Ethylene Propylene Runner (EPR) inshulation and LSZH inner bedding, steel wire armouring & FRLS outer sheath complete as required., SI No, 17.5.1 |
| 424 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia, SI No, 23.1.1.3 |
| 425 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 400 mm dia, SI No, 23.2.1.3 |
| 426 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm., SI No, 23.10.3 |
| 427 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS:8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia, SI No, 23.11.2 |
| 428 | Providing and fixing in 200X150 ERW Pipe Reducer including fittings complete., SI No, MR |
| 429 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200mm nominal size dia, SI No, 23.13.3 |
| 430 | Providing and fixing M.S. clamp of required dia made of 100 x10 mm flat to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts and nuts ofrequired size complete. 150mm nominal size dia, SI No, 23.14.2 |
| 431 | Providing and fixing M.S. clamp of required dia made of 100 x10 mm flat to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts and nuts ofrequired size complete. 200mm nominal size dia, SI No, 23.14.3 |
| 432 | Providing and fixing Bail plug / Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).150mm nominal size dia, SI No, 23.15.2 |
| 433 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge., SI No, 23.8 |
| 434 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge., SI No, 23.12 |
| 435 | Providing and fixing 80 dia G.I. column pipes complete with G.I. fittings including trenching and refilling etc., SI No, 18.12.8 |
| 436 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :80 mm dia, SI No, 18.59.2 |
| 437 | Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately)80 mm dia, SI No, 18.60.1 |
| 438 | Providing and fixing gun metal gate valve with C.I.wheel of approved quality (screwed end) : 80 mm dia, SI No, 18.17.6 |
| 439 | Providing and fixing gun metal non- return valve of approved quality (screwed end) :80 mm dia, SI No, 18.19.6.2 |
| 440 | PUMPING SETKSB make submersible pump set suitable for installation in bore well of min 150 mm inner dia preferably more and having under noted specifications.TYPE UQD 182/10 + 6 UMA I/H 150/22(S/D)+12.5HPCapacity 1400LPH Total Head 92M No of stages 6 Max OD of the pump set 150mm size of discharges out let 3” Speed in RPM 2900 RPM H.P. of Motor 5.5 KW/ 12.5 HP Method of starting star delta supply of voltage 400 V + 3% 3 phase The pumping set shall be comprise ( a ) Built in non-return valve ( b ) Six stages bowl assembly with bronze impellers and S. S. impeller shaft etc. ( c ) 12.5 HP 2900 RPM sub mersible electric motor suitable for Star/Delta starting with 3RM cable 2 x 3 x 4 sq mm, SI No, MR |
| 441 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm., SI No, 2.10.1.2 |
| 442 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter, SI No, 2.20.1 |
| 443 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1cement :1fine sand) including testing of joints etc. complete : 100 mm diameter RCC Pipes, SI No, 19.1.1 |
| 444 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1cement :1fine sand) including testing of joints etc. complete : 150 mm diameter RCC Pipes, SI No, 19.1.2 |
| 445 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1cement :1fine sand) including testing of joints etc. complete : 200 mm diameter RCC Pipes, SI No, 19.1.3 |
| 446 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1cement :1fine sand) including testing of joints etc. complete : 250 mm diameter RCC Pipes, SI No, 19.1.4 |
| 447 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design: 100 mm. dia. RCC Pipes, SI No, 19.3.1 |
| 448 | Providing and fixing square-mouth S.W. gully trap SP-1 complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type With common burnt clay FPS (non modular) bricks of class designation 75, SI No, 19.4.2.1 |
| 449 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 7.5, SI No, 19.7.1.1 |
| 450 | Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :- With common burnt clay F.P.S. (non modular) bricks of class designation 7.5, SI No, 19.7.2.1 |
| 451 | Extra for depth for manholes: Size 90x80cm With common burnt clay FPS (non modular) bricks of class designation 7.5, SI No, 19.8.1.1 |
| 452 | Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design., SI No, 19.16 |
| 453 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :- All kinds of soil Pipes, cables etc, not exceeding 80 mm dia., SI No, 2.10.1.2 |
| 454 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 20 mm dia nominal bore, SI No, 18.12.2 |
| 455 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 25 mm dia nominal bore, SI No, 18.12.3 |
| 456 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 32 mm dia nominal bore, SI No, 18.12.4 |
| 457 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 40 mm dia nominal bore, SI No, 18.12.5 |
| 458 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 65 mm dia nominal bore, SI No, 18.12.7 |
| 459 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :- 20 mm dia nominal bore, SI No, 18.40.2 |
| 460 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :- 25 mm dia nominal bore, SI No, 18.40.3 |
| 461 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :- 32 mm dia nominal bore, SI No, 18.40.4 |
| 462 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :- 40 mm dia nominal bore, SI No, 18.40.5 |
| 463 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :- 65 mm dia nominal bore, SI No, 18.40.7 |
| 464 | Providing and filling sand of grading zone V or coarser grade alround the G.I. pipes in external work. 20 mm dia nominal bore, SI No, 18.41.2 |
| 465 | Providing and filling sand of grading zone V or coarser grade alround the G.I. pipes in external work. 25 mm dia nominal bore, SI No, 18.41.3 |
| 466 | Providing and filling sand of grading zone V or coarser grade alround the G.I. pipes in external work. 32 mm dia nominal bore, SI No, 18.41.4 |
| 467 | Providing and filling sand of grading zone V or coarser grade alround the G.I. pipes in external work. 40 mm dia nominal bore, SI No, 18.41.5 |
| 468 | Providing and filling sand of grading zone V or coarser grade alround the G.I. pipes in external work. 65 mm dia nominal bore, SI No, 18.41.7 |
| 469 | Providing and fixing gun metal gate valve with wheel of approved quality. 20mm dia nominal bore, SI No, 18.17.1A |
| 470 | Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore, SI No, 18.17.1 |
| 471 | Providing and fixing gun metal gate valve with wheel of approved quality. 32mm dia nominal bore, SI No, 18.17.2 |
| 472 | Providing and fixing gun metal gate valve with wheel of approved quality. 40mm dia nominal bore, SI No, 18.17.3 |
| 473 | Providing and fixing gun metal gate valve with wheel of approved quality. 65mm dia nominal bore, SI No, 18.17.5 |
| 474 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design:- With common burnt clay F.P.S. (non modular) bricks of class designation 7.5, SI No, 19.27.1 |
| 475 | Constructing masonry Chamber 60 x 60 x 75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and180 mm deep (inside) with chain lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. With F.P.S. bricks, SI No, 18.33.1 |
| 476 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 50 mm dia, SI No, 27.11.2 |
| 477 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 65mm dia, SI No, 2711.3 |
| 478 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 80mm dia, SI No, 27.11.4 |
| 479 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 100mm dia, SI No, 27.11.5 |
| 480 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 150mm dia, SI No, 27.11.6 |
| 481 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 65 mm dia, SI No, 27.14.3 |
| 482 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 80 mm dia, SI No, 27.14.4 |
| 483 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia, SI No, 27.14.5 |
| 484 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 150 mm dia, SI No, 27.14.7 |
| 485 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange 80 mm dia, SI No, 27.15.1 |
| 486 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange 100 mm dia, SI No, 27.15.2 |
| 487 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange 150 mm dia, SI No, 27.15.3 |
| 488 | Providing two coats of Synthetic enamel paint of approved shade on pipes and supports as per pipe colour code over a coat of primer. Including painting of legends with direction arrow as per the approval of the Consultants / Project Manager. 65 mm dia, SI No, MR |
| 489 | Providing two coats of Synthetic enamel paint of approved shade on pipes and supports as per pipe colour code over a coat of primer. Including painting of legends with direction arrow as per the approval of the Consultants / Project Manager. 80 mm dia, SI No, MR |
| 490 | Providing two coats of Synthetic enamel paint of approved shade on pipes and supports as per pipe colour code over a coat of primer. Including painting of legends with direction arrow as per the approval of the Consultants / Project Manager. 100 mm dia, SI No, MR |
| 491 | Providing two coats of Synthetic enamel paint of approved shade on pipes and supports as per pipe colour code over a coat of primer. Including painting of legends with direction arrow as per the approval of the Consultants / Project Manager. 150 mm dia, SI No, MR |
| 492 | Supply, assembly, erection, testing and commissioning of pumping system comprising the following: MONOBLOCK PUMP, 2HP, 3PH HEAD RANGE: 20 to 40 MtrsFLOW RANGE: 124 to 20 LPMSUCTION X DELIVERY SIZE: 25 X 25 mmMAKE - LUBI INDUSTRIES LLP/EQFOR FILTER FEED PUMP, SI No, MR |
| 493 | Supply, assembly, erection, testing and commissioning of pumping system comprising the following:Vertical/ Horizontal centrifugal pumps with mechanical seal, SS Volute casing and SS impeller connected to suitable capacity TEFC induction motor suitable for 415 ± 10 % volts, 3 phase, 50 cycles A.C. supply with 100 mm dia. pressure gauges including MS skid and mounting of the pumps on the skid. (Motor to be of the same make as the pump) Pump Capacity (10m3/h@60M), 3HP (1 Working + 1 Stand-by) Domestic Water Supply MAKE - LUBI INDUSTRIES LLP/EQ, SI No, MR |
| 494 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks.25mm dia., SI No, MR |
| 495 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 65mm dia., SI No, MR |
| 496 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 80mm dia., SI No, MR |
| 497 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 100mm dia., SI No, MR |
| 498 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 150mm dia., SI No, MR |
| 499 | Providing and fixing motorised butterfly valve with float type sensors suitable for 240 volts with working pressure rating of not less than 5 kg/cm2 with control panel and sensors to open valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, conduits, upto junction box etc. complete. 80mm dia., SI No, MR Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail