| 1 | Taking out Wooden tile flooring work in floors Pasted to the Existing Floor with Adhesive including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm. |
| 2 | Supply & Fixing of Wonderwoods Engineered Wood Flooring 14 mm Thick including fixing Base ply of 12 mm thick anchored/pasted to the existing floor for providing Smooth & leveled surface to the top Wooden flooring including all Complete as per the direction & Complete satisfaction of Engineer in Charge. |
| 3 | Fixing of Wood Flooring 10 -25 mm Thick including fixing Base ply/Plastic Sheet anchored/pasted to the existing floor including 2mm foam underlay for providing Smooth & leveled surface to the top Wooden flooring including all Complete as per the direction & Complete satisfaction of Engineer in Charge. |
| 4 | Dismantling,cheeping, removing and Cleaning of old waterproofing layer from the roof shed surface with the help of required tools, wire brush, Chiesal, Hammer and make surface dust free surface and reach the sound surface level raking out joints and cleaning the surface for laying new waterproofing layer including disposal of rubbish to the dumping ground within 50 metres lead. |
| 5 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick |
| 6 | Providing & replacement of existng damaged Asbestos roof shed/sheetup to any pitch, including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. with same existing material or equivalent , with all operations including all necessary materials, labour including cutting and making good the surface wherever required all complete as per the direction of Engineer-in charge. |
| 7 | Dismantling wall tile including old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead |
| 8 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 9 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.size of Tile 600X600mm |
| 12 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 13 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/ litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour:New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 14 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 15 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 16 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 17 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick |
| 18 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead Of area 3 sq. metres and below |
| 19 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer -in - charge.Nominal concrete 1:4:8or leaner mix (i/c equivalent design mix) |
| 20 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 21 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 22 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 23 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 24 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 25 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 26 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 27 | Dismantling of Indian type W.C. pan along with \\"S\\" or \\"P\\" trap including dismantling of old WC seat and \\"S\\" or \\"P\\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba & , including cutting and making good the walls and floors wherever required all complete as per the direction of Engineer-in charge. |
| 28 | Providing and fixing Rimless Wall Hung WC With PP Soft Close Slim Seat Cover, Hinges, Accessories Set, Size: 355x555x370 mm with Single Piece Slim Concealed Cistern with wall mounting frame, installation kit \\"S-Type\\" Drain Pipe Connection Set & Metropole Flush Valves Regular of Duravit/Jaquar/Roca/Kohler make or equivalent make with all fittings and fixtures complete including cutting and making good the wall and floors wherever required in require colour & design etc. complete as per direction and entire satisfaction of Engineer -in - charge. |
| 29 | Providing and fixing Wall Hung Basin with Fixing Accessories of Size: 560x415x200mm including Full Pedestal of approved quality & make of Duravit/Jaquar/Roca/Kohler or equivalent make etc. complete as per direction and entire satisfaction of Engineer-in-charge. |
| 30 | Providing and fixing C.P. Brass Soap Dispenser with Glass Bottle of Duravit/Jaquar/Roca/Kohler make or equivalent make etc. complete as per direction and entire satisfaction of Engineer-in-charge. |
| 31 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1800 x 450 mm |
| 32 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 33 | Providing and fixing C.P. Brass Soap Dish Holder Duravit/Jaquar/Roca/Kohler make or equivalent make etc. complete as per direction and entire satisfaction of Engineer-in-charge. |
| 34 | Providing and fixing C.P. Brass Toilet Paper Holder Duravit/Jaquar/Roca/Kohler make or equivalent make etc. complete as per direction and entire satisfaction of Engineer-in-charge. |
| 35 | Providing and fixing Towel Ring Square with Round Flange Duravit/Jaquar/Roca/Kohler make or equivalent make etc. complete as per direction and entire satisfaction of Engineer-in-charge. |
| 36 | Providing and fixing C.P. Brass Angle valve with wall flange of Duravit/Jaquar/Roca/Kohler make or equivalent make etc. complete as per direction and entire satisfaction of Engineer-in-charge. |
| 37 | Providing and fixing C.P. Brass 2 Way Bib Cock with Wall Flange Duravit/Jaquar/Roca/Kohler make or equivalent make etc. complete as per direction and entire satisfaction of Engineer-in-charge. |
| 38 | Providing and fixing C.P. Brass Health faucet with 8 mm dia. 1 mtr long flexible tube & wall hook of Duravit/Jaquar/Roca/Kohler make or equivalent make etc. complete as per direction and entire satisfaction of Engineer-in-charge. |
| 39 | Providing and fixing stainless steel waste zalli / grating of approved quality and colour. Circular Type |
| 40 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia |
| 41 | Providing and fixing C.P. Brass Single Lever Basin Mixer without Popup Waste System with 450mm Long Braided Hoses Duravit/Jaquar/Roca/Kohler make or equivalent make etc. complete as per direction and entire satisfaction of Engineer-in-charge. |
| 42 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes |
| 43 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 44 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) 110 mm bend |
| 45 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee with door 110x110x110 mm |
| 46 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee without door 110x110x110 mm |
| 47 | Providing & fixing signage plate of different sizes made from 1.2mm thick stainless stell 304 grade sheet in glossy/matt finished,bend where ever required,photo etching informatory matter/logo including the cost of filling the matter with PU colour in required shape (Full area of plate & bend shall be measured for payment. |
| 48 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 49 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole :With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 50 | Providing and fixing at all height wall panelling with WPC material of required Size ,colour, pattern, thickness(Min thickness 18mm) and colour as per direction and entire satisfaction of Engineer-in-charge including providing and fixing to frame work hardwood plugs/fastners including cutting brick work and fixing in cement mortar and making good the wall etc. and selaing the junctions with or without beading (non exposed) with iron screws or any other means all complete as per direction of Engineer-in-Charge. |
| 51 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-chargeGI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. |
| 52 | Disposal of building rubbish/malba or similar unserviceable, dismantled, or waste materials by mechanical means, including loading, transportation, and unloading at any authorized C&D (Construction and Demolition) waste management site within a 25 km lead (e.g., Shastri Park, Burari, Mundka), including weighing at the plant, etc., complete as per the directions of the Engineer-in-Charge. Weighing and unloading at the plant shall be carried out as per the procedures/rules of the respective C&D waste management facility. The processing fee for C&D waste disposal, as per the prescribed rates, shall be deposited by the agency and will be reimbursed by the department upon submission of original cash receipts only. |
| 53 | Credit to dismantle items(i) Old Wooden Door |
| 54 | (ii) Old DoorFrame MS Angle Please Enable Macros to View BoQ information |