| 1 | SCHEDULE 'A' PART-I : BOQ OF WORKS FOR B/R WORKS. |
| 2 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and as directed. |
| 3 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and as directed. |
| 4 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc., complete all as specified and as directed. |
| 5 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each, complete all as specified and as directed. |
| 6 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each, complete all as specified and as directed. |
| 7 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), ncluding cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed. |
| 8 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition), including cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed. |
| 9 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed. |
| 10 | Dismantaling of brickwork or stone/ boulder/ block masonry, including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles built in cement mortar or cement lime mortar of any description, complete all as specified and as directed. |
| 11 | Taking down PVC pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories, complete all as specified and as directed. |
| 12 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed. |
| 13 | Pre-painted galvalume aluminium zinc coating galvanised iron based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specifed and directed. |
| 14 | Pre-painted galvalume aluminium zinc coating galvanised iron based plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specifed and directed. |
| 15 | Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation filling, complete all as specified and as directed. |
| 16 | Autoclaved aerated concrete (AAC) block masonry as in walls thickness exceeding 10cm in width and incluing setting in cement mortar 1:6, complete all as specified and as directed. |
| 17 | Pre-cast cement concrete block masonry M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate) with solid blocks, not exceeding 10cm in width and incluing setting in cement mortar 1:6, complete all as specified and as directed. |
| 18 | Rendering 15mm thick on fair faces of on brick work or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed. |
| 19 | Preparation of new plastered surfaces of walls and applying two coats of cement paint over one coat of priming plastered and other surfaces with alkali resistant priming paint, complete all as specified and as directed. |
| 20 | Rendering 15mm thick on fair faces of on brick work or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed. |
| 21 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth before applying any paint or oil emulsion, complete all as specified and as directed. |
| 22 | Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whiting, preparatory to distempering, complete all as specified and as directed. |
| 23 | Vitrified Ceramic tiles of light shade, 10mm thick (square/ rectangular) polished, non-skid, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed. |
| 24 | Vitrified Ceramic tiles of light shade, 10mm thick (square/ rectangular) polished, non skid area of each tile not exceeding 0.36 Per Square Metre, in skirting or in vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including fixed over screed bed or bedding layer of mortar 10mm thick in cement mortar 1:4, complete all as specified and as directed. |
| 25 | Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed bed 15mm thick on cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed. |
| 26 | Harrison rails, anodised aluminium alloy with fixing brackets, stops, rollers etc, suitable for curtains, complete all as specified and as directed. |
| 27 | Pressed steel frames for doors of size 125x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed. |
| 28 | Flush shutters, 30mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete al as specified and as directed. |
| 29 | Glazed and skeleton shutters in second class hardwood, 35mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats, complete all as specified and as directed. |
| 30 | Mild steel, 300mm, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed. |
| 31 | Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, having 140mm overall length of cover plate, fixed in floor, complete all as specified and as directed. |
| 32 | Butt hinges, size 100mm, medium weight, cold rolled mild steel, and fixed, complete all as specified and as directed. |
| 33 | Aluminium anodised, barrel tower bolts of extruded Section, size 150mm long and fixed, complete all as specified and as directed. |
| 34 | Extruded aluminium alloy handles, fabricated type, anodised, size 150mm, complete all as specified and as directed. |
| 35 | Anodised aluminium snap grid frame work for false ceiling, powder coated, comprising of aluminium Tee (weight of section not less than 280 gms/mtr) and aluminium angle (weight of section not less than 280 gms/mtr), grid size 605x605mm, including Hangers 6.0mm dia, galvanised iron (upto1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of galvanised iron flat 40x3 mm size 60mm long and expansion hold fasteners 12.50mm dia, 40mm long, complete all as specified and as directed. |
| 36 | Providing and fixing everest board 4mm thick, designer, in ceiling fixed as per manufacturer’s instructions, grid size 595x595mm, for false ceiling all as specified, complete all as specified and as directed. |
| 37 | PVC sheet fillet 5mm thick of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing, complete all as specified and as directed. |
| 38 | Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing, complete all as specified and as directed. |
| 39 | Preparation of new or previously untreated wood or wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed. |
| 40 | PVC (SWR) pipes, 110mm bore, single socketed, capacity not, less then 4.50 Kgf/Sqcm, in any length fixing with adhesive/ solvent cement, laid in trenches or in floors, complete all as specified and as directed. |
| 41 | Rolled mild steel in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.confirming to Fe 410-W (Gde- E- 250) quality- A, complete all as specified and as directed. |
| 42 | PVC (SWR) bends of 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, any radius, fixing with adhesive, complete all as specified and as directed. |
| 43 | Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed. |
| 44 | Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed. |
| 45 | Granite (of any type) work (table rubbed and polished), 20mm thick, as in steps, jambs, pillars, window cills, cooking plat forms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, and including laid over screed bed or bedding layer 20mm thick in cement mortar 1:6, complete all as specified and as directed. |
| 46 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations, complete all as specified and as directed. |
| 47 | Plain cement concrete M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate), 75mm thick, as in plinth protection, finish even and smooth without using extra cement, complete all as specified and as directed. |
| 48 | Powder coated (minimum thickness of powder coating 50 micron), anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and as directed. |
| 49 | Anodised aluminium powder coating of any colour (Thickness or powder coating not less than 50 micron) window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified. |
| 50 | Sheet glass, 4.80mm thick, tinted, ordinary quality and glazing with oil putty in square exceeding 0.50 Sqm in each pane, in square or any size, complete all as specified and as directed. |
| 51 | Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed. |
| 52 | Reinforced cement concrete, nominal mix, M-20 (1:2:4), type B-0 (using 12.50mm graded crushed stone aggregates) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed. |
| 53 | Formwork, use and waste type, to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, to get fair finish surfaces of concrete, complete all as specified and as directed. |
| 54 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 55 | Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, including binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed. |
| 56 | Reinforced cement concrete, nominal mix, M-20 (1:2:4), type B-0 (using 12.50mm graded crushed stone aggregates) as in beams, cantilevers, bressummers, lintels over 1.5mtrs span, complete all as specified and as directed. |
| 57 | Formwork, use and waste type, as in sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc., to get fair finish surfaces of concrete, complete all as specified and as directed. |
| 58 | Reinforced cement concrete, nominal mix, M-20 (1:2:4), type B-0 (using 12.50mm graded crushed stone aggregates) as in beams, chajjas, projections, complete all as specified and as directed. |
| 59 | Formwork, use and waste type, to to chullah hoods, chajjas, troughs and similar items including edges, to get fair finish surfaces of concrete, complete all as specified and as directed. |
| 60 | Dismantling timber scantlings unframed work in fillets, rails, posts, rafters, purlins, etc. under 40 Sqcm in section, in any position, complete all as specified and as directed. |
| 61 | Prelaminated particle board, 12mm thick, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work, complete all as specified and as directed. |
| 62 | Prelaminated particle board, 25mm thick, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work, complete all as specified and as directed. |
| 63 | Continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (when open) 30mm, complete all as specified and as directed. |
| 64 | Aluminium handles, cast type, anodised, size 75mm, complete all as specified and as directed. |
| 65 | French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats of French polish, complete all as specified and as directed. |
| 66 | Toughened glass, 10mm thick, as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required, complete all as specified and as directed. |
| 67 | SCHEDULE 'A' PART-II : BOQ OF WORKS FOR E/M WORKS. |
| 68 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 69 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and as directed. Please Enable Macros to View BoQ information |