| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. for All kinds of soil.As per DSR:Vol.1:2023 item 2.8.1 |
| 2 | Providing and Laying cement concrete of specified grade of concrete 1:4:8. |
| 3 | P/L R.C.C. upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR code no. 5.1.2 (9045.75x0.735) |
| 4 | centering and shurtiing includinh proping etc and removal of form for base of column etc for mass concrete as per DSR codeno. 5.9.1 @392.15 |
| 5 | centering and shurtiing includinh proping etc and removal of form for base of plinth band etc for mass concrete as per DSR codeno. 5.9.2 @842.50 |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and above plinth level of Thermo-Mechanically Treated bars of grade Fe-500D or more as per DSR:(Vol.-1):2023 Item 5.22.6 & 5.22A.6 |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : in 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu- ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) as per DSR:(Vol.-1):2023 Item 5.2.2 |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers as per DSR:(Vol.-1):2023 Item 5.9.5 |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and above plinth level of Thermo-Mechanically Treated bars of grade Fe-500D or more as per DSR:(Vol.-1):2023 Item 5.22.6 & 5.22A.6 |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).as per DSR:(Vol.-1):2023 Item 5.3 |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers as per DSR:(Vol.-1):2023 Item 5.9.5 |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and above plinth level of Thermo-Mechanically Treated bars of grade Fe-500D or more as per DSR:(Vol.-1):2023 Item 5.22.6 & 5.22A.6 |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) as per DSR:(Vol.-1):2023 Item 6.1.2 |
| 14 | Brick work 1:6 |
| 15 | Half brick masonary with common burnt clay F.P.S (non modular ) bricks of class designation 7.5 in foundation and plinth in cement mortar 1:4 as per DSR code no.6.12.2 @905.05 |
| 16 | 12 mm cement plaster of mix 1:6, 1 cement:6coarse sand |
| 17 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand |
| 18 | providing and applying plaster of paris putty of2mm thickness over plaster surface to prepare the surface even and smooth complete as per DSR code no. 13.26@ 262.70 |
| 19 | finishing walls with premium acrylic smooth exterior paint of requied shade new Work (two or more coats applied @1.43kg/10sqm and including priming coat of exterior priming applied @0.90 liter /10sqm) as per DSR code no.13.46 .1 @ 160.60 |
| 20 | Distemper with 1st quality acrylic distemper (ready to mixed) having VOC cotents less than 50 gram /liter of approved manufactured and of required Shade and colour all complete to achieve even shade and colour new work (two or more coats) over including water thinnaable priming coat with cement primer having VOC content less than 50 gram /liter as per DSR code no. 13.41.1 @185.65 |
| 21 | painting with synthetic paint of approved brand manufacture of required colour to give an even shade two or more coat on new work over an under coat of suitable shade with ordinary paint of approved brand and manufactuer DSR code no. 13.62.1 @226.25 |
| 22 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacture), of 1st quality conforming to IS 15622, of aooroved make in all colours laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand ), including grouting the joints with whitw cement and matching pigment etc., complete as per DSR code no. 11.40 @ 1439.40 |
| 23 | 1:4:8 derived from natural source 8 graded stone aggregate 40mm nominal size derived from natural sources as per DSR code no. 4.1.8 @6812 |
| 24 | Providing and laying Virtified floor tiles Kjaria / I.S.I Brand in difrent ( thickness specified by manufacturer ) with water absorption less than 0.8 % and confirming to I.S 15623 of approved make in all colours and shade laid on 20 mm thick cement morter 1:4 (1cement 4 coarsesand ) including grouting the joints with white cement and matching pigments etc. complite ( Size of tils 600x600 mm ) as per DSR code no.11.41.2 @1453.65 |
| 25 | steel Work welded in buit up section /framed work ,including cutting ,hosting ,fixing in position and applying a priming coat of approved steel primer using structural steel etc as required , in grating ,frame ,guard bar,railing brackets ,gates and similar works as per DSR code no. 10.25.2 @172.60 |
| 26 | Providing and fixing fatory made ISI market steel glazed doors windows and ventilators, side/top/centre hung witth bending and all member i/c providing and fixing of hinges pivots primer coat I/CS/O all materials labour and T&P etc. completie of work DSR.2023 Code no 10.11 i/c all complite work. Fixing with 15 x 3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C 1:3:6 |
| 27 | Filling available excavated earth (excluding rock) in trenches, plinth, side of foundations etc. in layers not exceeding 20cm in depth, consolidation each deposited layer by ramming and watering, lead up to 50m and lift up to 1.5m as per DSR codeno.2.25 @196 |
| 28 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections .DSR codeno.9.117 @331.35 |
| 29 | 25 mm thick PVC flush door shutters made out of a one piece Multi chamber ,As per DSR codeno. 9.118.3 @3068.85 |
| 30 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :as per DSR 9.96.2 @260.60 |
| 31 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ::as per DSR 9.97.3 @99.70 |
| 32 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :as per DSR [email protected] |
| 33 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, as per DSR code no.12.41.2 @136.15 |
| 34 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
| 35 | For pipes 250 to 300 mm diameter |
| 36 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes with ISI marked MS pressed butt hinges bright finished of required size with necessary screws 35 mm thick @3524.85 |
| 37 | Float glass panes 4 mm thick glass pane (weight not less than 10 kg per sqm) @2241.80 |
| 38 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. (110MM) as per DSR code no.12.43.2 @371.30 |
| 39 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. |
| 40 | SIGN BOARD |
| 41 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/ Hindware/ Seabrid /Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : |
| 42 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. |
| 43 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 44 | Semi rigid pipe |
| 45 | 32 mm dia |
| 46 | Providing and fixing unplasticised PVC connection pipe with brass unions |
| 47 | 45 cm length |
| 48 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 |
| 49 | a) 15 mm nominal bore |
| 50 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 51 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 52 | 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 53 | Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
| 54 | a) 100mm dia centrifugally cast iron S & S pipe. |
| 55 | b) 75mm dia centrifugally cast iron S & S pipe. |
| 56 | Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. ( for wash basin waste ) |
| 57 | 32mm dia nominal bore |
| 58 | Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe. |
| 59 | a) 100mm |
| 60 | SS 304 grade coupling with EPDM rubber gasket |
| 61 | b)75mm |
| 62 | size). Including cost of cutting holes & making good the walls etc. |
| 63 | a) for 100mm dia pipe. |
| 64 | b) for 75mm dia pipe. |
| 65 | Providing & fixing cast iron coller. |
| 66 | a) 100mm dia. |
| 67 | b) 75mm dia. |
| 68 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
| 69 | a) 100mm inlet & 100mm outlet. |
| 70 | Concealed work including cutting chases and making good the walls etc. |
| 71 | 20mm dia nominal outer dia pipes |
| 72 | 25mm dia nominal outer dia pipes |
| 73 | Capcity in Per Liters |
| 74 | Construction of chamber for 100mm sluice plates |
| 75 | Construction of chamber for 100mm sluices valve |
| 76 | Supplying, Conveying and fixing spls. Including ea |
| 77 | Supplying, Conveying and fixing spls. Including eart |
| 78 | Construction of chamber for 100mm sluice plates |
| 79 | Construction of chamber for 100mm sluices valve |
| 80 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using |
| 81 | Brick work in C.M 1:5 mix using 2nd class ground moulded chamber burnt bricks with including cost |
| 82 | Brick work in C.M 1:5 mix using 2nd class ground moulded chamber burnt bricks with including cost and conveyance of all materials and including all labour charges etc complete |
| 83 | Plastering in C.M 1:5-12 mm thick with including cost and conveyance of all materials and including all labour charges etc complete |
| 84 | Plastering in C.M 1:5-12 mm thick with including cost and conveyance of all materials and in |
| 85 | b) CI bend 22.5° (250mm dia) |
| 86 | Construction of chamber for 100mm sluice plates |
| 87 | Construction of chamber for 100mm sluices valve |
| 88 | Supplying, Conveying and fixing spls. Including ea |
| 89 | Supplying, Conveying and fixing spls. Including eart |
| 90 | Construction of chamber for 100mm sluice plates |
| 91 | Construction of chamber for 100mm sluices valve |
| 92 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using |
| 93 | Brick work in C.M 1:5 mix using 2nd class ground moulded chamber burnt bricks with including cost |
| 94 | Construction of chamber for 100mm sluices valve |
| 95 | Brick work in C.M 1:5 mix using 2nd class ground moulded chamber burnt bricks with including cost and conveyance of all materials and including all labour charges etc complete |
| 96 | Plastering in C.M 1:5-12 mm thick with including cost and conveyance of all materials and including all labour charges etc complete |
| 97 | Plastering in C.M 1:5-12 mm thick with including cost and conveyance of all materials and in |
| 98 | b) CI bend 22.5° (250mm dia) |
| 99 | Construction of chamber for 100mm sluice plates |
| 100 | Brick work in C.M 1:5 mix using 2nd class ground moulded chamber burnt bricks with including cost and conveyance of all materials and including all labour charges etc complete |
| 101 | Plastering in C.M 1:5-12 mm thick with including cost and conveyance of all materials and including all labour charges etc complete |
| 102 | Plastering in C.M 1:5-12 mm thick with including cost and conveyance of all materials and in |
| 103 | b) CI bend 22.5° (250mm dia) |
| 104 | Construction of chamber for 100mm sluice plates |
| 105 | Construction of chamber for 100mm sluices valve |
| 106 | Supplying, Conveying and fixing spls. Including ea |
| 107 | Supplying, Conveying and fixing spls. Including eart |
| 108 | Construction of chamber for 100mm sluice plates |
| 109 | Construction of chamber for 100mm sluices valve |
| 110 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using |
| 111 | Brick work in C.M 1:5 mix using 2nd class ground moulded chamber burnt bricks with including cost |
| 112 | Construction of chamber for 100mm sluices valve |
| 113 | Brick work in C.M 1:5 mix using 2nd class ground moulded chamber burnt bricks with including cost and conveyance of all materials and including all labour charges etc complete |
| 114 | Plastering in C.M 1:5-12 mm thick with including cost and conveyance of all materials and including all labour charges etc complete |
| 115 | Plastering in C.M 1:5-12 mm thick with including cost and conveyance of all materials and in |
| 116 | b) CI bend 22.5° (250mm dia) |
| 117 | Construction of chamber for 100mm sluice plates |
| 118 | Construction of chamber for 100mm sluices valve |
| 119 | Supplying, Conveying and fixing spls. Including ea |
| 120 | Supplying, Conveying and fixing spls. Including eart |
| 121 | Construction of chamber for 100mm sluice plates |
| 122 | Construction of chamber for 100mm sluices valve |
| 123 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using |
| 124 | Brick work in C.M 1:5 mix using 2nd class ground moulded chamber burnt bricks with including cost |
| 125 | Brick work in C.M 1:5 mix using 2nd class ground moulded chamber burnt bricks with including cost and conveyance of all materials and including all labour charges etc complete |
| 126 | Plastering in C.M 1:5-12 mm thick with including cost and conveyance of all materials and including all labour charges etc complete |
| 127 | Plastering in C.M 1:5-12 mm thick with including cost and conveyance of all materials and in |
| 128 | b) CI bend 22.5° (250mm dia) |
| 129 | Construction of chamber for 100mm sluice plates |
| 130 | Construction of chamber for 100mm sluices valve |
| 131 | Supplying, Conveying and fixing spls. Including ea |
| 132 | Supplying, Conveying and fixing spls. Including eart |
| 133 | Construction of chamber for 100mm sluice plates |
| 134 | Construction of chamber for 100mm sluices valve |
| 135 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using |
| 136 | Brick work in C.M 1:5 mix using 2nd class ground moulded chamber burnt bricks with including cost |
| 137 | Construction of chamber for 100mm sluices valve |
| 138 | Brick work in C.M 1:5 mix using 2nd class ground moulded chamber burnt bricks with including cost and conveyance of all materials and including all labour charges etc complete |
| 139 | Plastering in C.M 1:5-12 mm thick with including cost and conveyance of all materials and including all labour charges etc complete |
| 140 | Plastering in C.M 1:5-12 mm thick with including cost and conveyance of all materials and in |
| 141 | b) CI bend 22.5° (250mm dia) |
| 142 | Construction of chamber for 100mm sluice plates |
| 143 | Construction of chamber for 100mm sluices valve |
| 144 | Supplying, Conveying and fixing spls. Including ea |
| 145 | Supplying, Conveying and fixing spls. Including eart |
| 146 | Construction of chamber for 100mm sluice plates |
| 147 | Construction of chamber for 100mm sluices valve |
| 148 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using |
| 149 | Brick work in C.M 1:5 mix using 2nd class ground moulded chamber burnt bricks with including cost |
| 150 | Construction of chamber for 100mm sluices valve |
| 151 | The Total value of Schedule1 |
| 152 | The Total value of Schedule4 Please Enable Macros to View BoQ information |