| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. for All kinds of soil.As per DSR:Vol.1:2023 item 2.8.1 |
| 2 | Providing and Laying cement concrete of specified grade of concrete 1:4:8. |
| 3 | P/L R.C.C. upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR code no. 5.1.2 (9045.75x0.735) |
| 4 | centering and shurtiing includinh proping etc and removal of form for base of column etc for mass concrete as per DSR codeno. 5.9.1 @392.15 |
| 5 | centering and shurtiing includinh proping etc and removal of form for base of plinth band etc for mass concrete as per DSR codeno. 5.9.2 @842.50 |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and above plinth level of Thermo-Mechanically Treated bars of grade Fe-500D or more as per DSR:(Vol.-1):2023 Item 5.22.6 & 5.22A.6 |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : in 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu- ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) as per DSR:(Vol.-1):2023 Item 5.2.2 |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers as per DSR:(Vol.-1):2023 Item 5.9.5 |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and above plinth level of Thermo-Mechanically Treated bars of grade Fe-500D or more as per DSR:(Vol.-1):2023 Item 5.22.6 & 5.22A.6 |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).as per DSR:(Vol.-1):2023 Item 5.3 |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers as per DSR:(Vol.-1):2023 Item 5.9.5 |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and above plinth level of Thermo-Mechanically Treated bars of grade Fe-500D or more as per DSR:(Vol.-1):2023 Item 5.22.6 & 5.22A.6 |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) as per DSR:(Vol.-1):2023 Item 6.1.2 |
| 14 | Brick work 1:6 |
| 15 | Half brick masonary with common burnt clay F.P.S (non modular ) bricks of class designation 7.5 in foundation and plinth in cement mortar 1:4 as per DSR code no.6.12.2 @905.05 |
| 16 | 12 mm cement plaster of mix 1:6, 1 cement:6coarse sand |
| 17 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) |
| 18 | providing and applying plaster of paris putty of2mm thickness over plaster surface to prepare the surface even and smooth complete as per DSR code no. 13.26@ 262.70 |
| 19 | finishing walls with premium acrylic smooth exterior paint of requied shade new Work (two or more coats applied @1.43kg/10sqm and including priming coat of exterior priming applied @0.90 liter /10sqm) as per DSR code no.13.46 .1 @ 160.60 |
| 20 | Distemper with 1st quality acrylic distemper (ready to mixed) having VOC cotents less than 50 gram /liter of approved manufactured and of required Shade and colour all complete to achieve even shade and colour new work (two or more coats) over including water thinnaable priming coat with cement primer having VOC content less than 50 gram /liter as per DSR code no. 13.41.1 @185.65 |
| 21 | painting with synthetic paint of approved brand manufacture of required colour to give an even shade two or more coat on new work over an under coat of suitable shade with ordinary paint of approved brand and manufactuer DSR code no. 13.62.1 @226.25 |
| 22 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacture), of 1st quality conforming to IS 15622, of aooroved make in all colours laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand ), including grouting the joints with whitw cement and matching pigment etc., complete as per DSR code no. 11.40 @ 1439.40 |
| 23 | 1:4:8 derived from natural source 8 graded stone aggregate 40mm nominal size derived from natural sources as per DSR code no. 4.1.8 @6812 |
| 24 | Providing and laying Virtified floor tiles Kjaria / I.S.I Brand in difrent ( thickness specified by manufacturer ) with water absorption less than 0.8 % and confirming to I.S 15623 of approved make in all colours and shade laid on 20 mm thick cement morter 1:4 (1cement 4 coarsesand ) including grouting the joints with white cement and matching pigments etc. complite ( Size of tils 600x600 mm ) as per DSR code no.11.41.A.1.1 @1453.65 |
| 25 | steel Work welded in buit up section /framed work ,including cutting ,hosting ,fixing in position and applying a priming coat of approved steel primer using structural steel etc as required , in grating ,frame ,guard bar,railing brackets ,gates and similar works as per DSR code no. 10.25.2 @172.60 |
| 26 | Providing and fixing fatory made ISI market steel glazed doors windows and ventilators, side/top/centre hung witth bending and all member i/c providing and fixing of hinges pivots primer coat I/CS/O all materials labour and T&P etc. completie of work DSR.2023 Code no 10.11 i/c all complite work. Fixing with 15 x 3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C 1:3:6 |
| 27 | Filling available excavated earth (excluding rock) in trenches, plinth, side of foundations etc. in layers not exceeding 20cm in depth, consolidation each deposited layer by ramming and watering, lead up to 50m and lift up to 1.5m as per DSR codeno.2.25 @196 |
| 28 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge Extruded section profile size 42x50 mm as per DSR codeno.9.117 @331.35 |
| 29 | 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along thehinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25 mmX 11 mm. Door shutter shall be reinforced with specialpolymeric reinforcements as per manufacturer’s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places As per DSR codeno. 9.118.3 @3068.85 |
| 30 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :as per DSR 9.96.2 @260.60 |
| 31 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ::as per DSR 9.97.3 @99.70 |
| 32 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :as per DSR [email protected] |
| 33 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, as per DSR code no.12.41.2 @136.15 |
| 34 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
| 35 | For pipes 250 to 300 mm diameter |
| 36 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes with ISI marked MS pressed butt hinges bright finished of required size with necessary screws 35 mm thick @3524.85 |
| 37 | Float glass panes 4 mm thick glass pane (weight not less than 10 kg per sqm) @2241.80 |
| 38 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. (110MM) as per DSR code no.12.43.2 @371.30 |
| 39 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. |
| 40 | SIGN BOARD |
| 41 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/ Hindware/ Seabrid /Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : |
| 42 | W.C. pan with ISI marked black solid plastic seat and lid |
| 43 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. |
| 44 | White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 45 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 46 | 32 mm dia |
| 47 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 48 | Providing and fixing unplasticised PVC connection pipe with brass unions |
| 49 | 15 mm nominal bore |
| 50 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 |
| 51 | a) 15 mm nominal bore |
| 52 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 53 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 54 | 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 55 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
| 56 | a) 100mm inlet & 100mm outlet. |
| 57 | Concealed work including cutting chases and making good the walls etc. |
| 58 | 20mm dia nominal outer dia pipes |
| 59 | 25mm dia nominal outer dia pipes |
| 60 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 61 | Capcity in Per Liters |
| 62 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A |
| 63 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC Conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 64 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 65 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 66 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 67 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 68 | 1 or 2 Module (75mmX75mm) |
| 69 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 70 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 71 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 72 | Upto 450 mm sweep |
| 73 | Extra for fixing the louvers/ shutters complete with frame for aexhaust fan of all sizes. |
| 74 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 75 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 76 | 12 way , Double door |
| 77 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 78 | 6 way (4 + 18), Double door |
| 79 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 80 | Single pole |
| 81 | Double pole |
| 82 | Triple Pole & Neutral |
| 83 | Supply and fixing of recess/surface/pendent mounting round 6 watt to 8 watt LED down lighter having powder coeted die cost alluminium housing with heat sink, defuser/Reflector and driver set complete in all respect CAT-AAA |
| 84 | Supply and fixing of LED Tuve light with metal heavy duty Box type batten light fitting 2X22 watt suitable for upto 2X22 watt LED Polycarbonaate tube light complete Including tube suitable for both surface & suspended complete in all respect CAT-AAA |
| 85 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 86 | Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. Please Enable Macros to View BoQ information |