| 1 | Civil work |
| 2 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)DSR2023/15.2.1 |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar DSR 2023/15.7.4 |
| 4 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.DSR 2023/15.60 |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soilDSR 2023/2.6.1 |
| 6 | Construction of granular sub-base by providing close graded Material, spreading in uniform layers with motor grader on prepared surface,mixing by mix in place method with front end loder at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.SR |
| 7 | Proving and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to planth leve: 1:4:8 (1 cement:4 coarse sand (zone-II) derivedfrom natural source : 8 graded stone aggregate 40 mm nominal size derivedd from natural sources) DSR 2023/4.1.8 |
| 8 | Providing and laying factory made cobble shape paver block 80 mm thick, compressive strength >= M 30 steel mould compressive technology.SR |
| 9 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).DSR 2023/16.69 |
| 10 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth Complete.DSR 2023/13.80 |
| 11 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)DSR 2023/13.47.1 |
| 12 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameterDSR 2023/12.41.2 |
| 13 | Providing and fixing of Sandstone Garden Bench (3 Seater, without armrest & backrest), in rectangular shape sitting platform of size 1500mm (Length) x 400mm (Width) with two legs of size 350mm (height) x 450mm (width) x150mm thickness with sitting height of 450mm, fabricated from natural sandstone, machine cut with smoothened edges, fine dressed finish, suitable for outdoor use in gardens/parks/government premises, bench is to be treated with special epoxy resign for waterproof coating so as to make surface glossy and whether proof, complete in all respects as per direction of Engineer-in-Charge.MR |
| 14 | Electrical Work |
| 15 | Supply and fixing of 12 mtr High mast Pole of approved make with rising system, hot dip Galvanized inside & outside , having pole sheet thickness 4mm, top dia minimum150mm, bottom dia minimum 360mm, base plate 32mm thick, suitable for wind velocity as per IS 875 part 3 &.having no circumferential weld, with accessories for high mast such as head frame suitable for 6 luminaries & its control gear boxes,1 HP Power tool motor, 3 point suspension system with steel wire rope 6mm dia , double drum winch. Including making suitable Foundation as per manufacture drawing & site requirement along with foundation bolts, nuts, washers, anchor plates etc. Complete in all respect as per direction and satisfaction to the Engineer-in-charge. SOR2022/651 |
| 16 | Supply and fixing of factory wired integral LED flood lightluminaires with die cast aluminium housing built with dirver setsuitable for 170 to 180 Watt. Confirming to IP 66 protectioncomplete in all respect.CAT-AAASOR2022/1455 |
| 17 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. CertifiedSOR2018/725B |
| 18 | Supply and Fixing Following capacity of automatic street light cubical control panel painted with anticorrosive alkali and acid proof paint consisting of time switch Tso 100 series with contactors, HRC fuses, isolating switch metering instrument & intrument box with CTs etc. in case of TPN, complete in all respect. SOR-2022 SI. No. 807 (f) (I) 40 A TPNSOR2022/807 |
| 19 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed 4x16 sqmm cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.SOR2022/501(i) |
| 20 | Supply, installation, testing and commissioning of factory-wired integral LED street light luminaire suitable for 30W to 36W, with-die-cast-aluminium housing, IP65 protection, controlled by solar system.-Backup: Minimum 12 hours autonomy per day. Warranty: 3 years comprehensive warranty on complete system including LED, battery, solar panel and controller.Components included: 3 meter MS pole with base plate & foundation bolts, solar PV panel of suitable rating, LiFePO4/Lithium battery with weatherproof enclosure, MPPT/PWM charge controller, interconnecting cables, junction box, earthing, and all accessories required for complete installation for Solar System. (excluding Foundation)MR |
| 21 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge.16 sq. mm 4 coreSOR2022/503(i) |
| 22 | Supply and fixing of plain or pin type copper/Alluminium tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer16 sqmmSOR2022/504(D) Please Enable Macros to View BoQ information |