| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (DSR 2.8) All kinds of soil. (DSR 2.8.1) |
| 2 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 5 km, also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc., complete. (DSR No. 2.25A) |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR No. 4.1.) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR No. 4.1.2) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR No. 4.1.) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). (DSR No. 4.1.8) |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). (DSR No. 5.3) |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above. (DSR 5.22) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6/ 5.22.6.A) |
| 7 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1) |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) |
| 9 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR No. 8.31) |
| 10 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR No. 9.9) 30 mm thick (DSR No. 9.9.3.2) |
| 11 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.2) |
| 12 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR No. 9.48) Fixed to steel windows by welding (DSR No. 9.48.1) |
| 13 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR No. 9.70)125x64x1.90 mm (DSR No. 9.70.1) |
| 14 | Providing and fixing chromium plated brass handles with necessary screws etc. complete: (DSR 9.92) 125 mm (DSR 9.92.1) |
| 15 | Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete. (DSR No. 9.108)152x42x18 mm weighing not less than 60 gms (DSR No. 9.108.1) |
| 16 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR ) (DSR 10.2) |
| 17 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15 x 3 mm and nuts & bolts complete. (DSR No. 10.29)Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. (DSR No. 10.29.2) |
| 18 | Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with sand, with common burnt clay non modular bricks. (DSR No. 11.2) |
| 19 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR No. 11.3)40 mm thick with 20 mm nominal size stone aggregate (DSR No. 11.3.1) |
| 20 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (DSR 11.26) 25 mm thick (DSR 11.26.1) |
| 21 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete. (DSR No. 11.37) |
| 22 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. (DSR 11.46) Size of Tile 600x600 mm (DSR 11.46.2) |
| 23 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : (DSR No. 12.21)In 75x75 mm deep chase (DSR No. 12.21.1) |
| 24 | Providing and fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 fine sand). (DSR 12.37) Stone ware spout (DSR 12.37.1) |
| 25 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (DSR No. 12.41) 110 mm diameter (DSR No. 12.41.2) |
| 26 | 12 mm cement plaster of mix : (DSR No. 13.4) 1:4 (1 cement: 4 coarse sand) (DSR No. 13.4.1) |
| 27 | 12 mm cement plaster of mix : (DSR No. 13.4) 1:6 (1 cement: 6 coarse sand) (DSR No. 13.4.2) |
| 28 | 12 mm cement plaster finished with a floating coat of neat cement of mix : (DSR 13.7) 1:4 (1 cement: 4 fine sand) (DSR 13.7.2) |
| 29 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR No. 13.80) |
| 30 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : (DSR No. 13.41)New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre (DSR No. 13.41.1) |
| 31 | Finishing walls with Acrylic Smooth exterior paint of required shade: (DSR No. 13.46) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR No. 13.46.1) |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. (DSR No. 13.62.1) |
| 33 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour (DSR 13.81) Old work (one or more coats) (DSR 13.81.1) |
| 34 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DSR ) (DSR 13.91) |
| 35 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (DSR 13.99) One or more coats on old work (DSR 13.99.1) |
| 36 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.5.1) |
| 37 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. (DSR ) (DSR 14.85) |
| 38 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (DSR No. 15.3) |
| 39 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR 15.60) |
| 40 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. (DSR No. 15.7) In cement mortar (DSR No. 15.7.4) |
| 41 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (DSR No. 15.12)Of area 3 sq. metres and below (DSR No. 15.12.1) |
| 42 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. (DSR 15.23) For thickness of tiles 10 mm to 25 mm (DSR 15.23.1) |
| 43 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (DSR 15.56) |
| 44 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. (DSR 16.91.2) |
| 45 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (DSR No. 17.1) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (DSR No. 17.1.1) |
| 46 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (DSR No. 17.7A) (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. (DSR No. 17.7A) |
| 47 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. (DSR No. 17.23) |
| 48 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Flexible pipe 17.28.2 32 mm dia (DSR 17.28.2.1) |
| 49 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR No. 17.31) |
| 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work (DSR No. 18.9)20 mm nominal outer dia. Pipes. (DSR No. 18.9.2) |
| 51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work (DSR No. 18.9)25 mm nominal outer dia. Pipes. (DSR No. 18.9.3) |
| 52 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work (DSR No. 18.12)25 mm dia. nominal bore (DSR No. 18.12.3) |
| 53 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work (DSR No. 18.12) 32 mm dia. nominal bore (DSR No. 18.12.4) |
| 54 | Providing and fixing brass bib cock of approved quality : (DSR No. 18.15) 15 mm nominal bore (DSR No. 18.15.1) |
| 55 | Providing and fixing brass stop cock of approved quality : (DSR No. 18.16) 15 mm nominal bore (DSR No. 18.16.1) |
| 56 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore (DSR No. 18.17.1) |
| 57 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore (DSR No. 18.17.2) |
| 58 | Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 15 mm nominal bore (DSR 18.21.1.1) |
| 59 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) (DSR No. 18.46)25 mm nominal bore (DSR No. 18.46.3) |
| 60 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) (DSR No. 18.46) 32 mm nominal bore (DSR No. 18.46.4) |
| 61 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR No. 18.48) |
| 62 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : (DSR No. 18.53) 15mm nominal bore (DSR No. 18.53.1) |
| 63 | Providing and fixing 15 mm thick Industrial tiles size 600 x 600 mm to of Johnson Endura Meteor or approved make and colour using in different sizes (thickness to be specified by the manufacturer) conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete(NSI) |
| 64 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. (NSI) |
| 65 | Water proofing treatment over Roof, wall, Chajjas, Balcony etc. with Engineer Plus 7 layer waterproofing system at leakage, seepage area consisting of Surface preparation roughening of surface, opening of cracks in V groove in size of 5 mm to 10 mm width, Back filling of cracks with SBR Latex, 2 layer Spraying Mixture of Aquasil-99 and Aquaprime-99 (Take 20 liter clean water+ 1 liter Engineer Plus Aquasil-99 + 2 liter. Engineer Plus Aquaprime-99 in proportion 20:1:2 This solution should not sprayed over more than 40 sqm area, 3rd Laying 90GSM fiber glass mesh with proper overlap, 4th coat of brushable mortar prepared with Engineer Plus Aquaprime-99, water & cement (Aquaprime -99 @ 0.45 kg per sqm, water @0.45 kg per sqm & cement @0.68 kg per sqm.) in the proportion of 1:1:1.5 by weight, After 4th coat allow the coating to air cure for minimum four hours, after 4 hours interval apply, 2 coat of Flexicoat-99 mixed with Water (Flexicoat-99 @0.33 kg/sqm, water @0.66 Kg per Sqm) in the proportion of 1:2 by weight in 4 hours interval. After 6th coat allow the coating to air cure for minimum 4 hours. After 4 hours interval apply, 7th coat of Engineer Plus smartcoat-99 (Smartcoat-99 @ 0.45 Ltr/sqm & water @ 1.35Ltr/sqm in the proportion of 1:3). The surface will dry within 2 hours and surface would be fully water proof and usable after a period of 24 hours and the final appearance of the coating will be gray/milky white. The rates are included the cost of all chemicals, labours, and Required T&P for Proper completion of Work. |
| 66 | S/F welded wire mesh size 75x25mm and rectangular made out of 10 SWG over M.S. angle frame with M.S. flat welded as required including cost of drilling holes, washer welding etc as required including cost of all material, labour and T&P etc. required for proper completion of work . exept cost of M.S angle and flat. (CSI No. 9.22) |
| 67 | Precast Cement Concrete Septick tank 0.900 m dia pipe with cover with accessories & cover (NSI) |
| 68 | Providing and Fixing in postion wall paneling at all height with PVC wall panel/sheet (5-9mm thickness) of approved texture, design and pattern, having NRC (Noise Reduction coefficient) of 0.50 (Minimum), Light reflectance of 85% (minimum) Noncombustible, fire performance as per BS:476 (part 6&7), Humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, Proper Alignment and plumb with requaired at Edge Screws, cutting, wasteage, including transportation upto site with all material, labour and T/P For Proper Completion of the work as per direction of E/I (NSI) |
| 69 | Supply and fixing of 450mm size Exhaust fan of approved quality ISI mark (Bajaj/Havells/Usha/Crompton or equivalent make) complete with all respect as per sample approved by Engineer in charge including supply of all materials, labour and T&P etc requried for proper completion of the work as direction of E/I complete. (NSI ) |
| 70 | Supply and fixing of vertical blinds with hanging/sliding rod of aluminium (vista or equivalent make), vertical cord for operation of blinds, L-type hooks, screws, gullies etc. including all T&P, labour etc required for proper completion of the work in all respect. (NSI) Please Enable Macros to View BoQ information |