Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation in hard soil within 50 m linital lead and 1.50m initial lift including rough dressing breaking clods to maxikum 5cm to 7cm and laying in layers not exceeding 0.3M depth and as per OPWD Specification and direction of the Engineer-In-Charge. |
| 2 | Filling in foundation and plinth with excavated earth including watering and ramming as per OPWD Specification and direction of the Engineer-In-Charge. |
| 3 | Carriage of excavated earth by mechanial means awary from site within 5km lead including loading and unloading cost of all materials labour with T&P etc complete as per OPWD Specification and direction of the Engineer-In-Charge |
| 4 | Filling in foundation and plinth with sand including watering and ramming with cost, conveyance, royalty, taxes of all materials with all labour, T&P etc., complete as per the OPWD Specification and direction of the Engineer-in-charge. |
| 5 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the OPWD Specification and direction of the Engineer-in-charge. |
| 6 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 %) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge.. But excluding cost and conveyance of HYSD bar and binding wires and labour charges for straightening, cutting, bending etc. of HYSD Bar tying the grills and placing in proper position. - Column Base |
| 7 | Plinth Beam |
| 8 | RCC Wall for Lift - Ground Floor |
| 9 | First Floor |
| 10 | Second Floor |
| 11 | Third Floor |
| 12 | Column S/s & Roof Beam - Ground Floor |
| 13 | First Floor |
| 14 | Second Floor |
| 15 | Third Floor |
| 16 | Head Room |
| 17 | Lintel - Ground Floor |
| 18 | First Floor |
| 19 | Second Floor |
| 20 | Third Floor |
| 21 | Head Room |
| 22 | Chajja - Ground Floor |
| 23 | First Floor |
| 24 | Second Floor |
| 25 | Third Floor |
| 26 | Head Room |
| 27 | Staircase - Ground Floor |
| 28 | First floor |
| 29 | Second Floor |
| 30 | Third Floor |
| 31 | Roof Slab - Ground Floor |
| 32 | First Floor |
| 33 | Second Floor |
| 34 | Third Floor |
| 35 | Head Room |
| 36 | Supplying cutting, bending, binding & straightening coiled or bent up HYSD Bar of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of HYSD Bar and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for HYSD Bar only) etc. complete as per OPWD specification & direction of Engineer-in-charge.. Ground Floor |
| 37 | First Floor |
| 38 | Second Floor |
| 39 | Third Floor |
| 40 | Head Room |
| 41 | Cement concrete of proportion (1:2:4) in F&F using 12mm size cb/hb chips of approved quality including cost, conveyance, taxes & royalty of all materials and labour with T&P etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 42 | Fly Ash Brick masonry in C.M. (1:6) using of 23cmx11cmx8cm size brick having a crushing strength of not less than 75 kg per Sq.cm including splays, cuttings, circular moldings, watering & curing for 7 days, cost, conveyance, royalties of all materials, labour with T&P etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. - Foundation & Plinth |
| 43 | Super Structure - Ground Floor |
| 44 | First Floor |
| 45 | Second Floor |
| 46 | Third Floor |
| 47 | Head Room |
| 48 | Fly Ash Brick masonry in C.M. (1:4) Superstructure using of 23cmx11cmx8cm size brick having a crushing strength of not less than 75 kg per Sq.cm including splays, cuttings, circular moldings, watering & curing for 7 days, cost, conveyance, royalties of all materials, labour with T&P etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. - First Floor |
| 49 | Second Floor |
| 50 | Third Floor |
| 51 | 2.5cm thick grading concrete of proportion (1:2:2) over roof slab using 12mm to 6mm size cb chips of approved quality including cost, conveyance, taxes & royalty of all materials and labour with T&P etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge.Second Floor |
| 52 | Third Floor |
| 53 | Head Room |
| 54 | Providing 12 mm thick C.P. with C.M. (1:4) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. - First Floor |
| 55 | Second Floor |
| 56 | Third Floor |
| 57 | Providing 12 mm thick C.P. with C.M. (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 58 | First floor |
| 59 | Second Floor |
| 60 | Third Floor |
| 61 | Head Room |
| 62 | Providing 16 mm thick C.P. with C.M. (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 63 | First floor |
| 64 | Second Floor |
| 65 | Third Floor |
| 66 | Head Room |
| 67 | Providing 6 mm thick C.P. with C.M. (1:4) with screened and washed sharp sand for mortar and finished smooth over RCC surface in all heights including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 68 | First floor |
| 69 | Second Floor |
| 70 | Third Floor |
| 71 | Supplying, fitting and fixing of M.S. grills, grill gates, M.S. gates, garage door, Steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar of 10mm as per approved drawing and design with cost of all labour, materials & T&P, sundries etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. |
| 72 | Synthetic Enamel painting two coats over a coat of primer to Iron work including cost of all materials and labour with T&P etc complete in all respect as per OPWD specification & direction of Engineer-in-charge- Ground Floor |
| 73 | First floor |
| 74 | Second Floor |
| 75 | Third Floor |
| 76 | Head Room |
| 77 | Supplying, fitting, fixing of polished Vitrified floor tiles in Floor of premium grade having thickness (8mm to 10 mm) confirming to IS 15622:2006 (Group-B la) of 600mmx600mm plain (ivory) laid on 20mm thick bed of cement mortar (1:4) and filling jointed with white cement of approved quality including cost, conveyance of all materials, cost of all labour, T&P etc. complete as per OPWD specicication & the direction of the Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.) Make:Somany/ Jhonson/ Kajaria) - Ground Floor |
| 78 | First floor |
| 79 | Second Floor |
| 80 | Third Floor |
| 81 | Supplying, fitting, fixing of Industrial Vitrified floor tiles in Floor of premium grade having thickness 8mm to 10 mm confirming to IS 4457 of 300mmx300mm laid on 20mm thick bed of cement mortar (1:4) and filling jointed with white cement of approved quality including cost, conveyance of all materials, cost of all labour, T&P etc. complete as per OPWD specification & direction of the Engineer-in-charge (Note- Sample of tiles shall be approved before procurement and use.)- Ground Floor |
| 82 | Supplying, fitting, fixing of polished Vitrified floor tiles of premium grade having thickness 8mm to 10mm confirming to IS 15622:2006 (Group-B la) of 600mmx600mm plain (ivory) in Dados on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of tiles including cost, conveyance of all materials, cost of all labour, T&P etc. complete as OPWD specificaion per the direction of the Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.) Make:Somany/ Jhonson/ Kajaria)Ground Floor |
| 83 | First floor |
| 84 | Second Floor |
| 85 | Third Floor |
| 86 | Supplying, fitting, fixing of Granite tile of size above 0.10 Sqm and upto 0.4 sqm (20mm thick) laid on 25 mm thick Cement mortar (1:4) in floors with jointed with neat cement slury mixed with pigment to match the shades of tiles including rubbing and polishing etc complete including cost, conveyance of all materials, cost of all labour, T&P etc. complete as per OPWD specification and direction of the Engineer-in-charge. (Note : Sample of granite tiles shall be approved before procurement and use)Ground Floor |
| 87 | First floor |
| 88 | Second Floor |
| 89 | Third Floor |
| 90 | Supplying,fitting and fixing of Stainless Steel of 304 grade in Hand Railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mmx32mmx2mm @ 0.90 mtr. C/C and sainless square pipe bracing of size 32mmx32mmx2mm in 3 rows in stair case as per approved design and specification,buffing, polishing etc. with cost,conveyance,taxes of all materials,Labour,T&P etc. required for the complete in all respect as per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 91 | First floor |
| 92 | Second Floor |
| 93 | Third Floor |
| 94 | Supply and fitting, fixing of un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA Ltd) Three Track - Three Panel sliding window - 60 Series duly manufactured using UPVC reinforced profiles of 108mmx45mmx2.5 mm for outer frames, 38mmx58mmx2.5mm capable of mounting single glazing system, structurally reinforced with hot dip galvanished upto 50 microns of minimum thickness of 1.5mm prefebricated and welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT - GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminum 1 No per set or sashed and the system is to be installed at the site using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc, including cost and consveyance of all materials accessories labour charges, materialsn and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards as per OPWD specification & direction of Engineer-in-charge.All floor |
| 95 | Supply and fitting, fixing of un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA Ltd) Ventilator /TopHung - 60 Series duly manufactured using UPVC reinforced profiles of 60mmx55mmx2.5 mm for outer frames, 75mmx60mmx2.25mm for cashment window sash profile capable of mounting single glazing system, structurally reinforced with hot dip galvanished upto 50 microns of minimum thickness of 1.5mm prefebricated and welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT - GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminum 1 No per set or sashed and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc, including cost and consveyance of all materials accessories labour charges, materialsn and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards as per OPWD specification & direction of Engineer-in-charge. |
| 96 | Finishing to exterior wall surface with 2 (two) coats of weather seal coat of approved shade and approved make to give an even shade including cost of all material of all materials and labour with T&P etc. completeas per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 97 | First floor |
| 98 | Second Floor |
| 99 | Third Floor |
| 100 | Head Room |
| 101 | Finishing to interior wall surface with 2 (two) coats of Plastic Emulsion (P.E) Paint including cost of all material and labour with T&P etc. complete as per OPWD specification & direction of Engineer-in-charge - Ground Floor |
| 102 | First Floor |
| 103 | Second Floor |
| 104 | Third Floor |
| 105 | Head Room |
| 106 | Priming one coat to the wall surface including cost of all materials and labour with T&P etc. complete as per OPWD specification & direction of Engineer-in-charge - Ground Floor |
| 107 | First floor |
| 108 | Second Floor |
| 109 | Third Floor |
| 110 | Head Room |
| 111 | Providing & Fixinng factory made 100% Solid WPC (Wood Polymer Composite) - Door Frame 125 mm x 65 mm Single Rebated, made from Wood Polymer Composite (Single Extruded Process) material comparising of virgin PVC polymer of K Value 57-60 (Suspension Grade), Calcium Carbonate and Natural Fibers (Wood Powder/Rice Husk/ Wheat Husk) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full bdy treaded star headed screws having minimum frame density of 780 kg/cbm & an ISO 9001-2015 Certified Company, having good screw holding capacity (Screw Withdrawal strength of (Min. 990 N), Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners / Hold Fast of reuired dia and lenght, all as per specifications drawings as directed by the Engineer-in-Charge. - Ground Floor & First Floor |
| 112 | Providing and fixing of 30 mm thick factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with SS 304 Grade Matt Finished 3 Nos butt hinges of Size 100mm X 60mm X 2.5mm, 1 No 250mm X 16mm Aldrop,1 No 150mm x16mm tower bolt,2 No 150mm length Door handle with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Make: WPC: Century / Black Cobra / Rajshri Plastiwood, Hardware Fittings: Godrej / Dorset / Link / Dorma, Colour:Coffee Brown) |
| 113 | Providing and laying 80 mm thick factory made cement concrete interlocking paver block of M-40 grade made by block making machine with storng vibratory compaction of approved size, design & shape, laid in required colour and pattern as per drawing including all labour, transporting, T&P etc complete as per OPWD specification & direction of Engineer-in-charge. |
| 114 | Providing Antitermite treatments as per ISI specification including makig hols 3'0\\" C/C both ways injecting cemical with water in properation (1:20) or any approved propertion by the Engineer-in-Charge and treatment to choukath sides and wall juction cost and conveyance of all materials, labours, R&P etc completion as per OPWD Specification and direction of Engineer-in-Charge. |
| 115 | Construction of Granular Sub-Base by providing Grading-VI material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge. |
| 116 | Finishing surface of walls with Cement base wall putty (water based) of approved make and finishing the surface smooth and even by sand papering to receive paint in walls, at all heights with staging for all floors wherever necessary with cost, conveyance, of all materials, cost of all labour, all T&P etc. required for the work complete in all respect as per OPWD specification & direction of Engineer-in-charge. - Ground Floor |
| 117 | First floor |
| 118 | Second Floor |
| 119 | Third Floor |
| 120 | Head Room |
| 121 | EI Works : Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materialsGROUP-A |
| 122 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materialsGROUP-B |
| 123 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materialsGROUP-C |
| 124 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 125 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 126 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 127 | Supplying,fixing of 2x6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 128 | Supplying,fixing of 3x6A+1X16A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 129 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (2X1.5+1X1.5) |
| 130 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit. (2X2.5+1X1.5) |
| 131 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit (2X4+1X1.5) |
| 132 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (4X6+2X4) |
| 133 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit . (4X10+2X6) |
| 134 | Supplying and fixing 32 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed plug top along with 32 amps. C-series, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.. . Make-Legrand/Schneider/Siemens ISI marked as approved,All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.(for equipement only at required area) |
| 135 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 136 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 137 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 138 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 139 | (Light fitting Fixture & Fan)Supply, Installation, Testing and Commissioning of Duct mounted Single skinned Circular Inline Centrifugal Fan for Toilet Ventilation with direct driven Backward-curved impellers.The Fan has external rotor motor suitable for 1~, 230V, 50 Hz power supply. MAKE - SYSTEMAIR/ GREENHECK/ ELTA/Airflow2500 CFM @ 15mm MMWG static pressure |
| 140 | Supply & Fixing of Air Distribution Duting fabricated with Class VI GI Sheet(180 GSM) Complete With Supports, dampers, guiding vanes, access doors, MS Angle, Fire inhibiting gaskets, Nuts, bolts and all oyher accessories in accordance with approved drawing and the Specification. (Make:- Jindal/ Sail/ Tata)22 gauge (0.80 mm thickness) |
| 141 | 24 gauge (0.63 mm thickness) |
| 142 | Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire |
| 143 | Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery Greater than or equal to\\"215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years. |
| 144 | SITC of energy efficient LED tube light fittings with aluminium batten having provsion for 2 nos. 18-22W replacable LED Tube and lumen output not less than 4000 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /(TMC 502 2XT-LED 22W) Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . To be used for class room and parking area. |
| 145 | SITC of energy efficient LED tube light fittings with alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .To be used for corridor |
| 146 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 147 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 148 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door. |
| 149 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9./ABB SB 200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 150 | Supplying and fixing 40 Amps rating, 4P RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 151 | Supplying and fixing 63 Amps rating, 4P RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 152 | Supplying and fixing 40Amps 4P 415 volts, MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 3 years |
| 153 | Supplying and fixing 63Amps rating,C series,10KA breaking capacity, 4P 415 volts MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 1 year. |
| 154 | EARTHINGSupplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 155 | Providing and fixing SWG 6 GI wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. (to be used for Street Light) |
| 156 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 157 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 158 | Cable Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade (make-Polycab/ RR/ Finolex/ Havells/ KEI/ Gloster ) of following size cables as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials3.5core x 70 sq mm |
| 159 | Cable Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade (make-Polycab/ RR/ Finolex/ Havells/ KEI/ Gloster ) of following size cables as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials4core x 16 sq mm |
| 160 | Cable Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade (make-Polycab/ RR/ Finolex/ Havells/ KEI/ Gloster ) of following size cables as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials3.5core x 35 sq mm |
| 161 | LAYING OF CABLELaying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 162 | LAYING OF CABLELaying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 163 | LAYING OF CABLELaying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 164 | LAYING OF CABLELaying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 165 | TERMINATION OF CABLESSupplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 4 core x16sq mm |
| 166 | TERMINATION OF CABLESSupplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x35 sq mm |
| 167 | TERMINATION OF CABLESSupplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x70 sq mm |
| 168 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.50 mm dia |
| 169 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.200 mm dia |
| 170 | MAIN CONTROL PANEL AT GFS/I/T&Commissioning of CPRI tested LT indoor floor mounted double door with provision of padlock Metering main cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.20X10MM Separate Aluminium Earth bus bar should be installed.. 2 nos of 3P+N Type 1+2 SPD65kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer.Provision of OFF/ON/TRIP indication for all the feeders. Mandatory provision of cable alley is to be given.Make of SPD- Legrand/Siemens/Schneider/ABB/OBO/DEHNIn commer-1-01 number of 125A 4P Icu=100%Ics,36Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formulla/ Schneider- CVSIn commer-2-01 number of 125A 4P Icu=100%Ics,36kA MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formulla/ Schneider- CVSIn commer-2- 01 no of 125A 4P onload changeover switch (Make-LEGRAND/ Siemens/ Schneider/ABB )Busbar-1&2 04 numbers of 150Amps AL busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 01 numbers of 100A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ic( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formulla/ Schneider- CVSOut going- 06 numbers of 63A 4P MCB, c series,10 ka( Make-LEGRAND-DX3 / Siemens-Betaguard/ABB SB200/ Schneider- ACTI 9Out going- 06 numbers of 40 4P MCB,c series,10 ka( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formulla/ Schneider- ACTI 9 |
| 171 | LIFT PANELSITC of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder coated paint is designed as G.A drawing. (FOR LIFT)as per direction of Engg.-in-Charge. Warranty period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD(3P+N) 40ka with 63A 4P MCB,10kA, C series shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. 63amp panel board having 63A Amp 16KA 4P MCCB TMR based release with adjustable overload ,Icu=100%Ics as incommer, 100 amp electrolyte cu bus ba-1 Set, 63A Amp 4P RCCB 30mA- 1 No,25A Amp DP RCCB 30mA- 2 No,6-32A DP MCB 10ka, c series -2 No as Outgoing with ampere meter, voltmeter, toggler switch,three nos led indicator,Drum insulator,transparent isolation glass,danger Board and Rubber Mat as per the direction of site engineer in charge (make of mccb :-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULA) Make of MCB-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200(Lift Panel) |
| 172 | CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWERSupplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 173 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 174 | 8 PASSENGER LIFT WITHSupply,Installation, Testing & Commissioning of of 8 Passenger lift gearless with Machine room Capacity,Elevator S+3 (4 Stop) Floors with ACVVVF drive/Control for constant load of 544 kg ARD 1.25 MPS, SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc .SS material shall be of grade SS-304 and thickness not less than 1.2mm. Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons (v) flat cat6 cable for CCTV with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room,scaffolding ,floor cutting including Fireman's switch complete in all respect as per the instruction of Engg. in charge.The Elevator should be suitable for physically handicapped person. make:OTIS/Schindler/Mitsubishi/Johnson |
| 175 | Lightning Protection Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 176 | Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8Screw to connect the conductor holder.Weather andtemperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 177 | Supply of Polyamide roof cable holder for flat roof:DIN 48829 Form B1. Closed form with bottom. Filling weight1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 178 | Supply of Connector: For T cross and parallel connectors. Quickinstallation using hexagonal bolt M10X30 high-grade hot dipgalvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB |
| 179 | Supply of 1 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 180 | Supply of Vertical air terminal with accessories:Providing of Air terminalsas per IS-IEC -62305 part-3Nominal size Ø10/16 mm aluminium rod:2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 181 | Supply for Providing of Stand for Fang Fix system 16 kg with base andclamp ,made up of frost resistant concrete and clamp testedupto 100KA lightning current . Make-OBO/Dehn/ABB |
| 182 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete. Make-OBO/Dehn/ABB |
| 183 | Supply of Test Joint (Folding Clamp) suitable to connect 8mmround conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 184 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 185 | Supply of Galvanised Steel Flat 30X3 mm thickness from earthelectrode directly in ground as required. Flat conductor HotDipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 186 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 187 | Supply of flat conductor holder- Fit: FL 30, With mounting hole6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece fromhot-dip galvanised steel, Bottom section from polyamide, black.Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 188 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 189 | Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as perIEC 62561-2 Make-OBO/Dehn/ABB |
| 190 | Supply of universal clamp made of SS to connect rod with flatconductor Make-OBO/Dehn/ABB |
| 191 | Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB |
| 192 | Supply of The above arrangements shall be provided with Heavy dutyearth champer of 5000kg load bearing capacity to ensure thesafety of earthing system Make-OBO/Dehn/ABB |
| 193 | Lightning counter- To count no. of lightning strike and it can record the date and time of the lightning incident also tested as per IEC 62561-6. Make-OBO/Dehn/ABB |
| 194 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 195 | EXTERNAL ILLUMINATIONLight SystemS/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic coverPanasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj (5Years Warranty) |
| 196 | Supply of 6 mtr long hot dip Galvanized PU Painted Octagonal pole manufactured from HT steel(single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 197 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 198 | Supplying, Erection, Fixing, connection & testing of Panasonic 40 LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. Warrantied for a period of 5 years |
| 199 | S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 200 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Make- POLYCAB/KEI/HAVELLS /GLOSTER/FINOLEX/RR KABEL |
| 201 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 202 | CABLINGSupplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.4core x 16 sq mm |
| 203 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 204 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 4core x 16 sq mm |
| 205 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials32mm |
| 206 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 207 | LAN SYSTEMSITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance Less than or equal to 9.38 ohms/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 ohms @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit |
| 208 | SITC of Cat6 I/O with Single Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 micrometre. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit |
| 209 | SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit |
| 210 | SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50microns Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length) |
| 211 | SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50microns Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(2 mtr length) |
| 212 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit |
| 213 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19 inches ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit |
| 214 | SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear |
| 215 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP,Netgear |
| 216 | SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand |
| 217 | SITC of 24U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make:Valrack, Rittal, Legrand |
| 218 | Supplying and fixing of following sizes of HEAVY class PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak 20 MM |
| 219 | Supplying and fixing of following sizes of HEAVY class PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak 25 MM |
| 220 | CCTV SYSTEMSupply, Installation, Testing & Commissioning of 5MP IP Network TDN Low Light IR Fixed Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H:96.5°, V:73.8°(dome)/ Field of View FoV H:94.1°, V:71°(bullet), BLC, HLC, WDR, 2D/3DNR, White Balance Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES 128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : minus 30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130 4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make Honeywell Value series/Pelco/Axis/Bosch |
| 221 | Supply and installation of project series Network Video Recorder, support 32 Channel, Should support Resolution:- greater than equal to 12 MP IP Camera, Network Bandwidth incoming 320 Mbps and outgoing 320 Mbps for access, support for H.265+/H.265/H.264 encoding format streaming access and decoding output, Recording play back quality: 16 ch play back simultaneously, Recording resolution up to 12MP, Recording mode: support manual, Auto, Motion detection, Alarm, trigger record mode, Operation way: Mouse, local Login: Username and password, Recording storage: Local HDD, network, Video output: HDMI/VGA/TV, , Support min. 4 SATA HDDs , Each port supports min. 12TB HDD,Support dual Gigabit Ethernet ports,Supports 2 HDMI outputs with a maximum of 4K HD output,Alarm Input/out:16 in /1 out ,Audio:1 in / 1 out ,Raid: Raid 0 & Raid 1,Supports intelligent analytics such as Licence plate detection,Face Recognition,Human&Vehicle Detection,Perimeter Intrusion Detection,Line Crossing Detection, Cross Counting,Stationary Object Detection,Heat Map,Crowd Density Detection,Queue Length Detection, Rare Sound Detection, product must comply with NDAA complaince, Certification: BIS,CE,FCC,ROHS |
| 222 | Supply & Installation 10 TB Surveillence Hardisk.Make: Seagate/WD/Toshiba |
| 223 | SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony |
| 224 | FIRE FIGHTINGSupplying, installation, testing and commissioning of Electric Motor Driven Pressurization Terrace Pump having discharge of 450 LPM at 35 Mtr head complete with Pump Set, Electric Motor suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base Frame.(Make:PUMP:KBL/ Grundfos / KSB/ Wilo) |
| 225 | Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of One (1)- 63 Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable for 7.5 HP motor. ON/OFF indication lamps, Auto manual switch and ON/OFF push button.as per direction of engineer in charge Control panel for fire pumps for auto action.make-Legrand/schneider/Siemens/ABB |
| 226 | PIPE & VALVESSupplying, installation testing and commissioning of the following-: C class MS Pipe as per IS1239 for underground/over ground pipes with welded / flanged connection with saddles, supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches. The work includes excavation in all types of soils and back filling, dewatering, etc., making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the client and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overheads pipes and providing and fixing pyp kote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping for underground piping (wrapping should have overlap of 15 to 20 mm) etc.Complete as per ASTM standards/IS: 10221 for corrosion protection of pipes for the underground installation.Note: The piping installation has to be put to hydraulic test to1.5 times the working pressure & as per latest applicable codes & standard before applying paint or pipe coating or wrapping etc. complete. Make-TATA/JINDAL/SAIL100mm NB |
| 227 | Supplying, installation testing and commissioning of the following-: C class MS Pipe as per IS1239 for underground/over ground pipes with welded / flanged connection with saddles, supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches. The work includes excavation in all types of soils and back filling, dewatering, etc., making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the client and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overheads pipes and providing and fixing pyp kote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping for underground piping (wrapping should have overlap of 15 to 20 mm) etc.Complete as per ASTM standards/IS: 10221 for corrosion protection of pipes for the underground installation.Note: The piping installation has to be put to hydraulic test to1.5 times the working pressure & as per latest applicable codes & standard before applying paint or pipe coating or wrapping etc. complete. Make-TATA/JINDAL/SAIL80mm NB |
| 228 | Supplying, installation testing and commissioning of the following-: C class MS Pipe as per IS1239 for underground/over ground pipes with welded / flanged connection with saddles, supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches. The work includes excavation in all types of soils and back filling, dewatering, etc., making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the client and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overheads pipes and providing and fixing pyp kote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping for underground piping (wrapping should have overlap of 15 to 20 mm) etc.Complete as per ASTM standards/IS: 10221 for corrosion protection of pipes for the underground installation.Note: The piping installation has to be put to hydraulic test to1.5 times the working pressure & as per latest applicable codes & standard before applying paint or pipe coating or wrapping etc. complete. Make-TATA/JINDAL/SAIL25mm NB |
| 229 | Providing, fixing, testing and commissioning of following size manually operated hand lever type cast iron double flanged slim seal wafer type Butterfly valves with EPDM iron disc as per IS-13095 having pressure ratting PN -1.60 including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of E.I.C. Make-Zoloto/Leader/Audco100mm NB |
| 230 | Providing, fitting & fixing of following size cast iron double flanged type dual plate Non return Valve as per IS- 5312 (Part 1): 2004 with ISI mark of pressure ratting PN-1.60 including fixing the same with supply of required jointing materials like flanges, rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of Engineer-in-charge. Make-Zoloto/Leader/Audco100mm NB |
| 231 | Supply,Installation,Testing & Commissioning of Pressure gauge of 0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable size with all accessories as per direction of Engineer-in-charge.Make-H.Guru/G.Guru |
| 232 | Supply,Installation,Testing & Commissioning of Pressure Switch with cut-off bronze ball valves with integral strainer & flare nut (mixed ends) of suitable size with all accessories as per direction of Engineer-in-charge.Make-Danfoss/Indfoss/Grundfoss |
| 233 | Supply,Installation,Testing & Commissioning of stainless steel strainer fabricated out of 1.6 mm thick stainless steel sheet Y Stainer with 3 mm dia hloes with stainless steel flange as required. Make-Zoloto/Leader/Audco100mm NB |
| 234 | DOWN COMER SYSTEMSupply,Installation,Testing & Commissioning of Stainless steel Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique type, as per IS :5290/93 and as per direction of Engineer-in-charge.Make-Newage/Minimax/Fireshield |
| 235 | Supply,Installation,Testing & Commissioning of SS short branch pipe with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 and as per direction of Engineer-in-charge. Make-Newage/Minimax/Fireshield |
| 236 | Supply,Installation,Testing & Commissioning of 63 mm NB and 15meter long RRL Fire Hose fitted with 63mm intstantaneous stainless steel male & female SS coupling, complete by GI wire binding for Internal Hydrant as per direction of Engineer-in-charge. Make-Newage/Minimax/Fireshield |
| 237 | Providing supply & fixing of MS Hose Box for of suitable size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30 mtr long fire hose and a branch pipe, wall mounted type as per direction of Engineer-in-charge. Make-Newage/Minimax/Fireshield |
| 238 | Supply,Installation,Testing & Commissioning of Swinging pattern wall fixing first aid hose reel made from MS sheet and waterways and moving parts with rubber hose of 20 mm dia. and 30 mtrs. long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585 Type-I., complete with all accessories as per direction of Engineer-in-charge. Make-Newage/Minimax/Fireshield |
| 239 | Providing, fitting and fixing of C.I. 25 MM single air relief valve with stop cock confirming to IS:14845/2000 with ISI mark for water works purpose including fixing the same with hydrant riser including testing & commissioning the system etc. all complete as per approved specification & direction of Engineer-in-charge. |
| 240 | Providing, fitting & fixing of 2-Way GM fire brigade connection consisting of 63 mm dia instantaneous type male couplings with built-in check valves, 150mm dia flanged outlet complete with bolts, nuts and rubber insertions confirming to IS:904 with ISI mark including testing & commissioning the system etc. all complete as per apporoved specification & direction of EIC. Make-Zoloto/Kirloskar |
| 241 | EXTINGUISHER SYSTEMPortable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge. Make-Safex/Fireshield/Ceasefire/FLAMEKLOG |
| 242 | Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete. Make-Safex/Fireshield/Ceasefire/FLAMEKLOG |
| 243 | Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter \\"FIRE\\" in black out side and handle with mounting bracket. |
| 244 | SIGNAGESSITC flexyl of Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages |
| 245 | ON GRID SOLAR SOLAR PV SYSTEMSupply Installation Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono PERC HALF CUT bifacial Crystalline silicon solar cells, net metering facility ,necessary protections, earthing, mounted on hot dip GI structure( solar panel bottom height from roof level shall not be less than 300mm, accordingly GI structure to be designed) of suitable strength with following components a complete as arequired: a) Solar Photovoltaic Module of capacity 545Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 22%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc.g) SITC of outdoor(IP65) 63A 4P MCCB with bidrectional meter with 2mm CRCA hot dip galvanised panel asrequired. with all required accessories as required as per the direction of Engg-in-charge.Make-Tata/waree/luminous/adani/panasonic. The entire SOLAR system should be Replacement Warranty will be 5 years |
| 246 | GPH Works : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes and PVC ASTM conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge(Supsreme/Ashirvad/Oriplast/Shaakya) In Ground Floor floor25mm dia UPVC ASTM-D Pipes |
| 247 | 32mm dia UPVC ASTM-D Pipes |
| 248 | In 1st Floor floor20mm dia C-PVC Pipes |
| 249 | 25mm dia C-PVC Pipes |
| 250 | 32mm dia UPVC ASTM-D Pipes |
| 251 | 50mm dia UPVC ASTM-D Pipes |
| 252 | In Second floor20mm dia C-PVC Pipes |
| 253 | 25mm dia C-PVC Pipes |
| 254 | 32mm dia UPVC ASTM-D Pipes |
| 255 | 50mm dia UPVC ASTM-D Pipes |
| 256 | In 3rd floor20mm dia C-PVC Pipes |
| 257 | 25mm dia C-PVC Pipes |
| 258 | 32mm dia UPVC ASTM-D Pipes |
| 259 | 50mm dia UPVC ASTM-D Pipes |
| 260 | In 4th floor32mm dia C-PVC Pipes |
| 261 | 50mm dia UPVC ASTM-D Pipes |
| 262 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm thick wall In 1st floor |
| 263 | 250mm thick wall In 2nd floor |
| 264 | 250mm thick wall In 3rd floor |
| 265 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.In 1st floor |
| 266 | In 2nd Floor |
| 267 | In 3rd floor |
| 268 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge.15mm dia CP two way bib cock(CON-CHR-041KN) |
| 269 | 15mm dia CP hand shower with reebit cleaning system (ABC chrome plated-Jaquar make-HSH-CHR-85537) |
| 270 | 20mm dia CP Con. stop cock (CON-CHR-089KN) |
| 271 | 15mm dia CP angle stop cock(CON-CHR-053KN) |
| 272 | 15mm dia C.P Pillar cock(CON-CHR-021KN) |
| 273 | CP towel rail (25 mm)(ACN-CHR-1111N) |
| 274 | CP Soap dish Holder (ACN-CHR-1131N) |
| 275 | 125mmdia C.P.grating |
| 276 | 15mm dia CP flange |
| 277 | 15mm Cp extention piece |
| 278 | 32mm brass full way valve |
| 279 | 50mm brass full way valve |
| 280 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge.10 litres capacity pvc low level cistern (Slimline-white) |
| 281 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge. |
| 282 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 3.18m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge2000litre capacity water storage tanks(3 layers)(Sintex make) (4th Floor) |
| 283 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge(Supsreme/Ashirvad/Oriplast/Shaakya) 110mm dia U-PVC SWR pipes |
| 284 | 110mm U-PVC door Tee |
| 285 | 110mm U-PVC door bend |
| 286 | 110mm U-PVC Y Tee |
| 287 | 110mm U-PVC plain bend |
| 288 | 110mm dia U-PVC off set |
| 289 | 110mm U-PVC plain Shoe bend |
| 290 | 110mm U-PVC plain Tee |
| 291 | 110mm dia U-PVC cowl |
| 292 | 110mm dia U-PVC clamp |
| 293 | 75mm dia U-PVC SWR pipe(Supreeme/Ashirvad make) |
| 294 | 75mm dia U-PVC plain Tee |
| 295 | 75mm dia U-PVC plain bend |
| 296 | 110mm x 75mm dia U-PVC Reducing Socket |
| 297 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI/PVC SWR pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge250mm to 375mm thick wall |
| 298 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI P or S trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge580mm size Orissa pan (Parryware/Cera/ Nycer Make) |
| 299 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral P or S trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in chargeE.W.C. with S trap plain with seat cover(Parryware/Cera/ Nycer Make) |
| 300 | Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge600mmx450mmx250mm size porcelain Sink |
| 301 | Supplying all materials, labour, T&P and fixing glazed earthenware squatting plate with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:5:10) using 40mm hard granite metal all complete as per specification and direction of the Engineer in chargeSquatting urinal (Parryware make) |
| 302 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge Counter top basin 560x455 (Parryware make) white |
| 303 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in chargeBig size mirror |
| 304 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn First floor |
| 305 | In Second Floor |
| 306 | In Third Floor |
| 307 | Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In FF |
| 308 | In Second Floor |
| 309 | In Third Floor |
| 310 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge1st Floor |
| 311 | 2nd floor |
| 312 | 3rd floor |
| 313 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. IN FF ,C. basin slab 1x3.00x0.6x0.10 |
| 314 | IN SF ,C. basin slab 1x3.00x0.6x0.10 |
| 315 | IN TF ,C. basin slab 1x3.00x0.6x0.10 |
| 316 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. 0.80 qntl/ cumIn First Floor |
| 317 | In Second Floor |
| 318 | In Third Floor |
| 319 | Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1\\"-6\\" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge.First Floor |
| 320 | Second Floor |
| 321 | 3rd Floor |
| 322 | Supplying all materials, labour, T&P and fixing Granite tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge In First floor |
| 323 | IN SF, C.Basin |
| 324 | IN TF, |
| 325 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge12mm thick CP (1:4) on bw- In FF |
| 326 | In Second Floor |
| 327 | In Third Floor |
| 328 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles etc. complete as per direction of the Engineer in charge.Ceramic floor tiles of premium grade Kajaria / Somany make of size 60cm x 60cm to be pre-approved by the Engineer in chargeIn First Floor |
| 329 | In Second Floor |
| 330 | In Third Floor |
| 331 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles etc.complete as per direction of the Engineer in charge. (Ceramic wall tiles of premium grade Kajaria / Somany make size 60 x 30 special plain / printed series to be pre-approved by the Engineer in charge)In First floor |
| 332 | In Second Floor |
| 333 | In Third Floor |
| 334 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 335 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 336 | Supplying all materials,labour T&P and providing window sliding (Alluminium Louvers) type made alumunium section 9778 in window section 4095 & 4096 & 3994 in shutter frame 5mm thick glass panel fitting with rubber bending inding socket arrangement etc.all complete as per the direction of the Engineer-in-charge |
| 337 | Supplying all materials, labour, T&P and distempering two coats to walls with distemper of approved shade on new work to give an even shade etc all complete as per specification and direction of the Engineer in chargeIn First Floor |
| 338 | In , S floor |
| 339 | In , T floor |
| 340 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:1.5:3) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, fly ash bricks in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI/P-trap gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in chargeInside size 250mmx250mm |
| 341 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeInside size 760mmx760mmx460mm |
| 342 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeInside size 910mmx910mmx910mm |
| 343 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeBrick masonry soakway pit 1.80m dia x 2.60m deep |
| 344 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit |
| 345 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class 3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturers specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C 1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm dia u-pvc pipe alround concrete |
| 346 | 160mm dia u-pvc pipe alround concrete |
| 347 | Construction 1 nos 100 users RCC Septic tankEarth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 348 | - do - with addl. Depth of 1.5 m |
| 349 | Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department. |
| 350 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge |
| 351 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 352 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 353 | Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 354 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeFor Roof Slab |
| 355 | For RCC wall |
| 356 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 357 | Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 358 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 359 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 360 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
| 361 | Dewatering with 5 H.P diesel engine pump during excavation |
| 362 | Supplying all materials, labour, T&P and providing, fitting and fixing U-PVC SWR Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge160mm U-PVC plain Tee |
| 363 | Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete. |
| 364 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. 110mm diameter U-PVC SWR pipes(Supreme/Ashirvad) |
| 365 | 110mm U-PVC cowl |
| 366 | Construction of RCC UG Water Storage Tank (I/s: 5.00 x 3.00 x 2.00m )Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 367 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 368 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
| 369 | Supplying all materials, labour, T&P and providing dewatering water from pit using 5 HP disel pump set etc.all complete as per specification and direction of the Engineer in charge |
| 370 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 371 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 372 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeR.C.C floor and roof slabs, landings, balconies, projecting sunshades and chajjas up to 4.30m height |
| 373 | R.C.C beams, columns, girder and bressmer etc--In G.F |
| 374 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 375 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor |
| 376 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor (inside) |
| 377 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor (inside) |
| 378 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 379 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 380 | Supplying all materials, labour, T&P and providing 450mm dia x 50mm thick RCPC man hole cover in cement concrete (1:2:4) using 12mm size h.g chips, placing the cover on the man hole/ inspection chamber and finishing smooth all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in chargeR.C.P.C. Cover(20\\"/22\\" round Man hole cover) |
| 381 | Supplying all materials, labour, T&P and providing, fitting and fixing of 5HP Three Phase Drainage Pump motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trail running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge2HP Horizontal Submerssible Pump |
| 382 | DOL Control panel |
| 383 | 2.50 sqmm flat cable |
| 384 | Supplying all materials, labour, T&P and providing & electrification to submerssible pump sets and service connection including fitting fixing of electric board & Switch etc all complete as per direction of the Engineer in charge. |
| 385 | Supplying all materials , labour, T&P and providing & fixing to wall or ceiling and floor pvc pipes confirming to ASTM-D & pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction.40mm dia UPVC ASTM-D Pipes |
| 386 | 50mm dia UPVC ASTM-D Pipes |
| 387 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge.40mm dia brass fullway valve(Shakti Make) IS:778 - 1984 class-I |
| 388 | 40mm brass ball cock with ball |
| 389 | Supplying all materials ,labour for removing of sludge from septic tank and disposing them at a suitable distance by engaging sweeper using cess pool truck through biring at a safe distance etc.all complete as per direction of the Engineer-in-charge |
| 390 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.Making MS step iron in 20mm diameter MS steel bars |
| 391 | Sinking of 200mmx150mm dia Tube well.Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore onlyDrilling of 200mm dia bore 00 mtr.to 30 mtr. |
| 392 | 30 mtr.to 60 mtr. |
| 393 | 150 mm dia bore 60 mtr.to 120 mtr |
| 394 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.Lowering of 200mm dia PVC casing pipes 00 mtr.to 30 mtr. |
| 395 | 30 mtr.to 45 mtr. |
| 396 | Cost of 200mm dia P.V.C schedule-80 pipe |
| 397 | Supplying all materials and labour,tools and plant and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5 mtrs below ground level(as per drawing)to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock the bottom to ensure sanitary sealing(excluding cost of cement which willbe supplied by the Department).Sanitary sealing upto 5mtrs below ground level. |
| 398 | C.C(1:2:4) |
| 399 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in chargeBy DTH/Rotary Rig |
| 400 | Supplying all materials and labour,tools and plant and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5 mtrs below ground level(as per drawing)to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock the bottom to ensure sanitary sealing(excluding cost of cement which willbe supplied by the Department). Submerssible Pump Set 1.50 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 6110 L.M.P with outlet dia of 32 mm. |
| 401 | DOL control panel |
| 402 | 2.50 sqmm cable |
| 403 | 32mm dia steel short piece |
| 404 | 32mm HDPE pipe |
| 405 | Steel rope with cover |
| 406 | Well cap |
| 407 | C.I.Bracket |
| 408 | Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site. |
| 409 | Supplying all materials, labour, T&P and constructing Bore well protection chamber of the inside size 650x650x1000hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4) inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy