| 1 | Dismantling the existing damaged ceramic tiles including clearing materials away from the site and all labour charges etc complete. |
| 2 | Dismantling the existing damaged Plain cement concrete surface Up to 3M height including clearing away from the site and all labour charges etc complete . |
| 3 | Dismantling the existing damaged brick/stone masonry wall in cement mortor Up to 3M height including clearing away from the site and all labour charges etc complete . |
| 4 | Earth work excavation and depositing on the bank with initial lead and lift of 10 metres and initial lift of 2 metres in hard stiff clay stiff block cotton hard red earth murram, gravel stoney earth and earth mixed with small size boulders and hard gravelly soils (SS 20 B) etc., complete as per standard specification . |
| 5 | Cement Concrete 1:5:10 (One cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken jelly for flooring including laying,nsolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete multiplying with standard specification and as directed by the departmental officers. The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers -Mixing by Manual means |
| 6 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation |
| 7 | Without strutting |
| 8 | Coloumn |
| 9 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards. (No separate payment will be made by the Department for the excess usage of materials) |
| 10 | Upto Basement |
| 11 | Manufacturing, supplying and fixing of 75mm Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed. |
| 12 | Supplying and fabrication placing in position of M.S. (or) RTS rods for required size and length as directed by the departmental officers approved design including bending cutting tying and cost of binding wire cost and conveyance of all materials to site etc., complete as per standard specification - 1 Qtl |
| 13 | Brick work in Cement Mortar 1:5 mix using best quality Burnt Clay Brick of size 9” x 4 3/8” x 2 3/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. |
| 14 | Upto Basement |
| 15 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 16 | Flooring with Self Designed Colour Ceramic Tiles of size 305 x 305 x 6mm size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 17 | Dadooing with printed design colour glazed tiles of size 300 x 200 x 6mm best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 18 | Supply and fixing of SS Heavy duty long body tap 15mm dia of approved quality including cost and conveyance of all materials to site and all labour charges etc complete |
| 19 | Supply and fixing of 30W LED street light fitting with LED (Higher end) with 25 mm dia. GI pipe (class B) with 1 no. 25 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting .(SD-454) |
| 20 | Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. |
| 21 | Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for making good for PVC Open light point / Fan point (For Electronic regulator) etc, complete as per standard specifications. SD 21 |
| 22 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVCrigid pipe on wall and ceiling with PVC accessories with 150mm x 100mm x 113mm TW switch box in flush with wallwith 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch with painting ofsuitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC plug point (SD-37) |
| 23 | Wiring with 2 x 4sqmm (56 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for 15A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire for Open PVC power plug point.SD 41 |
| 24 | Supply and fixing of 4Feet LED 18W Fitting with LED 18W tube (LowerEnd) complete with TW roundblocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting(SD-440) |
| 25 | Supply and fixing of 1400mm sweep (56\\") AC ceiling fan complete with stepped electronic 300W regulator with 1metre down rod including fan clamp with side plates and cross arm of size 450mm(SD-108) |
| 26 | Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with Two coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 27 | Painting Old Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 28 | Painting New Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 29 | Solid PVC Door Shutters using 19 Gauge 19mm MSsquare tubes for styles and outer frames. 15mm MSsquare tubes for top, lock and bottom rails. The steeltubes shall be covered with 5mm thick solid PVCSheets. Shutter using 5mm thick solid PVC Sheets forpanelling shall rigidly fixed in position includingnecessary furniture and fittings. The over all size ofstyles shall be 50mm x 30mm. The over all size of toprail, lock rail and bottom rail shall be 75mm x 30mm.The over all size of frames shall be 50mm x 45mm withsuitable rabate for housing the shutter |
| 30 | Supply and fixing of 450mm (18\\") sweep (light duty) AC exhaust fan complete with necessary wall opening andmaking good of the wall(SD-118) |
| 31 | Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.- Mixing by manual means |
| 32 | Fabricating supplying and fixing of Poly carbonate sheet of 6mm thick, The sheet to be fixed with the required size and making ornamental designs as per the site condition and as directed by the departmental officers. |
| 33 | Providing and erecting of Direction and Place Identification Retro-reflectorised Signs made out of Cube Corner Micro Prismatic Grade Sheeting confirming to Type-XI standards of IRC-67: 2022 and ASTM D 4956 –09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mmx25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2022 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer-in-charge. Micro Prismatic grade Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.9 of IRC 67-2022. The retro -reflective sheeting shall be covered under 10 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2022. ( as per MoRT&H Specification No.801) (For location of blackspot, curve, sharp bend, junction, ghat roads and criticalzone applications) |
| 34 | Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion (SD-348) |
| 35 | Supply and delivery of PVC Pipe and G.I Pipes Specials approuved quality of departmental officers loading, unloading Cost and conveyance of all materials to Site etc., Complete. |
| 36 | 4\\" PVC pipe |
| 37 | 2 1/2\\" PVC Elbow |
| 38 | 2 1/2\\"PVC Tee |
| 39 | 4\\" PVC Elbow |
| 40 | 4\\" PVC Tee |
| 41 | 4\\" PVC Aircowl |
| 42 | 4\\" PVC Nahini Trap |
| 43 | 1\\" PVC pipe |
| 44 | 1\\" PVC Elbow |
| 45 | 1\\" PVC Tee |
| 46 | 1\\"X3/4\\" PVC Reducer elbow |
| 47 | PVC Water tank |
| 48 | Laying and Jointing the following PVC Pipes and GI pipes and Specials with proper gradient and test for all labour charges etc., Complete. |
| 49 | 4\\" PVC pipe |
| 50 | 1\\" PVC pipe Please Enable Macros to View BoQ information |