| 1 | Brick Work with common burnt clay F.P.S(non-modular) Bricks of class designation 75 in super structure above plinth level upto floor V level in all shapes and sizes in:cement mortar of 1:6 (1 cement and 6 course sand) With all leads lifts and carriage upto site of work. (Including making good/replacement of any damage caused to existing finished works such as floor/wall tiles, skirting, dado etc. complete job) |
| 2 | 15mm Cement plaster on the rough side of single or half brick wall ofmix: 1 : 6 ( 1 cement : 6 fine sand) |
| 3 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 4 | Providing and fixing of U-PVC sliding/casement/fix window in white colour,frame 60mm thick (min) x 90mm (min) with 1.5 mm GI reinforcement sash 39mm (min) 58mm (min) with 1.25mm GI U section reinforcement with rubber gasket of grey / black colour 10 years warranty against weathering of profile with complete hardware fittings and with 5mm thick toughened glass and fiber jalli option pre- febricated on german fabrication system( mosquito sash 18mm(min) x 43mm(min)(with welled cornes) complete at site (for shutters) Make: Fenesta, Prominance or Lesso |
| 5 | Providing & fixing U-PVC system in walls in white colour,frame 60mm (min)x45 mm (min) with 1.5 mm GI reinforcement,sash 39 mm (min)x58 mm(min) with 1.25 mm GI- U section reinforcement with rubber gasket of grey/black colour, 10 years warranty against weathering of profile with complete hard ware fittings and with 5mm clear toughned glass or 12mm thick high pressure laminated board panels as per design wherever required (with welded corners ) complete at site. (For partition Walls ) Make: Fenesta, Prominance or Lesso |
| 6 | Providing and fixing of U-PVC sliding/casement/fix doors in white colour,frame 60mm thick (min) x 45mm (min) with 1.5 mm GI reinforcement sash 39mm (min) 58mm (min) with 1.25mm GI U section reinforcement with rubber gasket of grey / black colour 10 years warranty against weathering of profile with complete hardware fittings fixed with 12mm thick high pressure laminated board panels as per design or with 5mm toughened glass if required (with welled cornes) complete at site including all fixtures Make: Fenesta, Prominance or Lesso |
| 7 | Providing and fixing wood work in frames of doors, windows and other frames, wrought framed and fixed in position including SS expansion fastners for brick / concrete work in (including cost of all material, leads, lifts and carriages etc upto site of work complete Kiln seasoned and chemically treated hollock wood as per the directions of engineer in charge/as per the drawings |
| 8 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 9 | Providing and laying in position specified grade of cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 11 | Suspended floors, slabs, roofs, landings, balconies and access platforms. |
| 12 | Foundations, footings, drains etc. |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 14 | Providing and fixing 35 mm thick panelled door shutters (Kiln seasoned & chemically treated hollock wood). with ornamentals Wood pannels including necesary stainlless Steel Butt hinges /screws etc. Design of shutter and pannels as per the instructions of Engineer incharge complete in all respects.((Kiln seasoned & chemically treated hollock wood) |
| 15 | Providing and fixing 4mm thick panels of plain glass for fixed glazing panels/ shutters (only panel area to be measured) including cost of teak wood beadings of required size complete |
| 16 | Providing and fixing hardware fittings of approved brand and of required type as approved by Engineer incharge. complete as per the specifications . (Brass) |
| 17 | Modular door lock ss finish handle 10\\" with duaal locking system inside & outside (godrej) |
| 18 | Tower bolts 150mm (doors) |
| 19 | Handle 125mm (door) |
| 20 | Providing and applying Polyurethane (PU) polish on wooden doors of approved make and shade, including surface preparation by thorough sanding with emery paper, filling of joints and grains with wood filler, application of sealer coat, rubbing down, and applying minimum two or more coats of PU polish (base + top coat) to achieve uniform smooth finish of required shade and gloss level, complete as per manufacturer’s specifications and as directed by Engineer-in-Charge, including cost of all materials, labour, tools, tackles, scaffolding, leads and lifts etc. complete. specifications and as directed by the engineer Incharge.(doors) |
| 21 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 13753 of miniumum thickness 6 mm of approved make like NITCO, ORIENT, SOMANY KAJARIA or equivalent make in all colours, shades except begundy, bottle green, black of any size as approved by the Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of Cement Mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. sample to be approved by Engineer-in-charge. Size if Tile 600 x 1200 mm. (including cost of all material, leads, lifts and carriages etc upto site of work complete). |
| 22 | Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members, self aligning /centering arrangement and support plates as per ASTM B221-02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063.) |
| 23 | Providing and applying cement based wall putty of required thickness over plastered surface to prepare the surface even and smooth complete in specified areas as per specified patter. (Birla make) (including cost of all material, leads, lifts and carriages etc upto site of work complete). |
| 24 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. |
| 25 | Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 26 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink with waste pipe as perI.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink without drain board 470x420mm bowl depth 178mm |
| 27 | Providing and fixing CP brass Sink mixer of approved make and manufacture, make: Hindware/Jaguar/Cera. 15mm dia nominal bore |
| 28 | Providing and fixing C.P. brass angle valve for basin mixer and geyser/cisterns points. Makes:- Hindware/Jaquar/Cera 15mm dia nominal bore |
| 29 | Providing and fixing unplasticised PVC connection pipe with brass unions: 45 cm length, 15mm nominal bore |
| 30 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 31 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. |
| 32 | Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. PN-16 pipe , 25mm OD(SDR-7.4) |
| 33 | Exposed on wall with clamps at 1.00 meter spacing PN-16 pipe , 40mm OD(SDR-7.4) |
| 34 | Earth work in Excavation in all kinds of soil by mechanical means in foundation trenches including dressing of sides and ramming of bottom with all leads and lifts including disposal of surplus soil within a lead of 50m from cutting edge as per direction of Engineer incharge |
| 35 | Providing and laying in position of stone soling including levelling, watering, ramming with all leads, lifts and carriage up to the site of work. |
| 36 | Providing and laying in position cement concrete in 1:4:8 (1 cement : 4 coarse sand : 8 graded crushed stone aggregate,40mm nominal size) excluding the cost of centering and shuttering but including carriage of all materials from approved sources up to site of work complete. All Work up to plinth level |
| 37 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 38 | Painting with synthetic enamel paint with of approved brand and manufacture to give an even shade, two or more coats on new work |
| 39 | Demolishing brick work manually/by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar |
| 40 | Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 41 | Cutting of reinforcement bars manually/by mechanical means inR.C.C. or R.B. work |
| 42 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc.,by applying cemnet slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement@ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement compound @ 0.126 kg/sqm. This layer will be allowed t air cure for 4 hours followed with water curing of 48 hours. The rate includes preparation of surface, treatment and sealingof all joints ,ciorners, juntions of pipes and masonry with polymer mixed slurry. |
| 43 | Making soak pit 2.5 m diameter 3.0 metre deep with 45x45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8 long complete as per standard design. |
| 44 | Constructing septic tank of size 5.00 m × 2.50 m × 1.40 m (approx.) or as per site requirement (height to be fixed below invert level of last manhole to maintain minimum 1.5 m water depth), in brick masonry with class designation 75 bricks in cement mortar 1:4 with minimum wall thickness of 350/230 mm as required, including excavation in all kinds of soil, dressing, ramming, dewatering if required and disposal of surplus excavated earth within lead, providing and laying stone soling at base followed by PCC 1:4:8, finished smooth, including construction of internal partition/baffle wall, providing and fixing 100 mm dia SW/PVC inlet and outlet pipes, plastering inside walls and floor with 12 mm thick cement plaster in CM 1:3 finished smooth with neat cement finish mixed with waterproofing compound, including providing and casting RCC top slab of required thickness with reinforcement including providing and fixing CI/FRP manhole cover with frame and vent pipe with mosquito proof cowl, including refilling, compaction, all leads and lifts, cost of materials, labour, tools & plants and all incidental works complete as per standard design, drawings and as directed by Engineer-in-Charge |
| 45 | Designing, fabricating, testing, installing and fixing in position withAluminium Composite Panel Cladding, with open grooves for linear as well as curvilinearportions of the building, for all heights and all levels etc. including: Providing and fixing Aluminium Composite Panel (ACP) duct covering of approved make, colour and shade, made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). (as approved by Engineer-in-Charge) consisting of ACP sheets (aluminium sheets bonded with polyethylene core) fixed over a suitable aluminium framework made out of aluminium sections (minimum 25mm × 25mm × 1.2mm thick or as required), rigidly anchored to wall with dash fasteners, screws, brackets, cleats etc. complete, including fabrication of framework to proper line, level and alignment, cutting, bending, grooving and routing of ACP sheets to required shape, forming box-type duct enclosures, fixing with stainless steel screws/rivets, providing necessary stiffeners, supports and access openings wherever required, sealing of all joints with weather-proof silicone sealant including EPDM tape to make the duct covering water-tight and dust-proof, complete with all materials, labour, scaffolding/staging at all heights, tools and plants, carriage, loading/unloading, wastage, finishing and all incidental charges as per approved drawings and directions of Engineer-in-Charge, complete in all respects, measured in square metres (sqm) of finished surface area. |
| 46 | Granite Work: Providing and fixing ( gang saw cut mirror polished (flamed , pre-moulded and pre-polished), machine cut for flooring, steps ,risers of stairs etc.( flamed instaircase) of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding (of edges wherever required ) and polishing to edge to give high gloss finish etc. complete at all levels. Granite of any colour and shape 18mm thick. and slab area over 0.50 sq m. (Note: The Granite stone slab shall be cut to required size and laid to the required pattern including rounding, chamfering, bull nosing of the edges as directed. Actual area of slab, as laid shall be measured) Sample to be approved by Engineer-in-charge. (including cost of all material, leads, lifts and carriages etc. upto site of work complete |
| 47 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : |
| 48 | Extra for pre finished nosing of kota stone slab. |
| 49 | Providing and fixing approved quality stone wall tiles / stone cladding (machine cut / natural finish / honed finish as approved), of size as approved, random ashlar pattern, or equivalent modular sizes, in grey / beige / slate / quartzite, 12–14mm thick, fixed over prepared plastered surface with polymer modified adhesive (or 12 mm thick bed of 1:3 cement sand mortar backing where required), including surface preparation, backing coat, edge cutting, dressing, alignment, proper bond, jointing with matching pigment mortar / epoxy grout, and all leads & lifts complete as per approved sample and direction of Engineer-in-Charge |
| 50 | Providing, dressing, moulding, and fixing approved quality granite stone beading (drip course/cornice) 20–25 mm thick at top of plinth wall cladding, machine cut or hand dressed to required profile, proper outward slope, necessary projection/overhang, bedding in cement mortar 1:3, jointing, pointing with matching pigment, curing, scaffolding, cutting, wastage, and all complete as per design and direction of Engineer-in-charge |
| 51 | Carriage and disposal of available excavated earth (excluding rock) to approved dumping/filling site near proposed Lawyers Chamber or at any other location near site as directed by engineer in charge, including all lifts and leads, loading, unloading, and filling in layers not exceeding 20 cm thickness, watering and compaction by ramming, complete job. |
| 52 | Provision for inaugration stone: Providing and fixing inauguration stone comprising of polished black granite/marble plaque of minimum size 2.5 ft × 4.0 ft and approved thickness with engraving of inscription matter and filling with approved paint, including edge polishing and fixing in position with cement mortar/adhesive, also including providing and fixing decorative/engraved wooden cornice/frame around the plaque wherever required as per approved design, including providing and fixing curtain arrangement with suitable cloth, rods, pulleys, ropes and fittings for unveiling and decorative top/canopy arrangement with supporting framework and covering, and including arrangements for inauguration ceremony such as providing and erecting shamiana/tent (pandal) for guests with chairs, basic stage setup, and other incidental arrangements as required complete with all materials, labour, carriage, loading, unloading, scaffolding, tools and tackles and all incidental charges, complete as per direction of Engineer-in-Charge. Please Enable Macros to View BoQ information |