| 1 | Demolition of cement concrete of any description and in any position not otherwise specified provided complete all as specified and directed |
| 2 | M&L for 25 mm thick PCC B-0 1:2:4 (12.5 mm graded) as in PCC under layer complete all as specified and directed. |
| 3 | M&L for water proofing treatment to flat roof and edges applying 3 mm thick APP based polymeric membrane of approved manufacturer with weight not less than 3.00 kg / sqm reinforced with non woven polyster fabric weight not less than 150 gm per sqm on primed surface by force application over the APP membrane @ 0.11 kg/ sqm over applying evenly a priming coat with bituminous primer @ 10 kg kg/sqm after necessary cleaning the surface and applying one coat of aluminium paint over APP membrane including removal of existing membrane complete all specified and as directed. |
| 4 | M&L prime the surface with BTD with water @ 1:1 ratio (200gm BTD 200gm water) and use as primer @400 gm/m2 allow the primer coat to touch dry condition apply 1st coat of ShaliUrethene® BTD @ 0.8 kg/m2 by brush/roller/airless spray while the primed surface is tacky. For faster and smoother application, apply with airless gun.Allow 1st coat to dry for 10-12 hr Apply 2nd coat of ShaliUrethene BTD @ 0.8 kg/m2 by brush/roller/airless spray for final DFT of 1200 micron in two coats including taking down old APP membrane and prepration of surface complete all as specified and directed. |
| 5 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 6 | Supply and fixing Mild steel framed work of angle or other section as in gusset plates, rails braces, wind ties, cleat, hold fasts etc, complete as required conforming to Fe-290 Gde E-165 complete as specified and directed |
| 7 | S&F Mild steel framed work in tubular trusses and tubular posts using ERW or induction butt welded tubes conforming to I.S 1161-1979 Grade St-240 including necessary welding, bolting, special shaped washer, clamps, cleats etc. with and including one shop coat of zinc chromate primer paint complete all as specified & as directed. |
| 8 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as directed. |
| 9 | S&F Pre-painted galvalume aluminium zink coating GI based corrugated/semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 10 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 11 | S&F 0.63mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 etc complete all as specified & as directed. |
| 12 | S&F Mild steel framed work such as grills, gratings etc.with ends of bars shouldered and/or riveted,or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290 Gde-E-165 complete all as specified and as directed. |
| 13 | S&F hard drawn steel wire fabric, weight not exc 4 Kg per sqm, cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcement complete all as specified & as directed. |
| 14 | M&L for preparation of new steel surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all specified and as directed. |
| 15 | Dismantling of ceiling boards (fiber, pulp, insulation etc) or insulation boards /slabs/blankets any thickness including cover fillets as specified. |
| 16 | Supply and fixing powder coated anodised aluminium interlocking snap grid frame work size (600 mm x 600 mm) consists of main tee runners of size 38mm x 25mm x1.5mm and cross wall angle of size 25 mm x 25 mm x 1.5 mm spaced between the main Tee at 600 mm centre to centre to form a grid of 600 mm x 600 mm etc complete including GI wire hanger at 1200mm intervals necessary notching preparing holes and supporting hanger comprising of J hooks soffit cleat holding clip, level clip etc as per manufacturer instructions complete all as specified and directed. |
| 17 | M&L for 4mm thick, Non asbestos fibre cement building boards of make 'E' board classic designer board (cascade or Occenic) of M/S Everest industried ltd or equivalent MES approved make fixed in ceiling or laid/ inserted to timber/GI/Aluminium frame work with screws, etc complete as specified and as directed. |
| 18 | M&L for Gl frame work for seamless ceiling size of grid 605x605mm, comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and providing and fixing gypsum board of 12mm thick in ceiling complete all as specified and directed |
| 19 | S&F PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium /G.I./M.S. as per specification and drawing alongwith Supply and fixing anodized aluminium snap grid frame work for false ceiling as per manufacturer instructions complete all as specified & as directed. |
| 20 | Taking up or down steel tubing and connections of 15mm bore, fixed in walls, ceiling, floors, trenches etc complete all as specified and as directed. |
| 21 | Taking up or down steel tubing and connections of 20mm bore, fixed in walls, ceiling, floors, trenches etc complete all as specified and as directed. |
| 22 | S&F for 15 mm bore “medium grade” mild steel galvanised iron (GI) tubing with all fittings fixed to wall, ceiling or floors, complete all as specified and as directed. |
| 23 | S&F for 20 mm bore “medium grade” mild steel galvanised iron (GI) tubing with all fittings fixed to wall, ceiling or floors, complete all as specified and as directed. |
| 24 | Dismantling 500 ltr water tank and removing to store complete all as specified and as directed. |
| 25 | Supply and fixing 500 liters rotational moulded polyethylene water storage tank, multi layered (cylindrical vertical with closed top cover) as per IS-12701-1996, hoisted and fixed in position including necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I complete all as specified and as directed. |
| 26 | Dismantling 1000 ltr water tank and removing to store complete all as specified and as directed. |
| 27 | Supply and fixing 1000 liters rotational moulded polyethylene water storage tank, triple layered (cylindrical vertical with closed top cover) as per IS-12701-1996, hoisted and fixed in position including necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I complete all as specified and as directed. |
| 28 | S&F 25mm Gun-metal. globe or gate valves, with iron wheel headt screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 29 | S&F 25mm Ball brass valves. high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed. |
| 30 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc. including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fitting and accessories) complete all as specified and as directed. |
| 31 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 110 mm bore of pipe complete all as specified and as directed. |
| 32 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or fixed to floor for 110 mm bore of pipe complete all as specified and directed. |
| 33 | S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 34 | S&F PVC (SWR) 75mm bore pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 35 | S&F 75 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 36 | Supply & Fixing Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof suitable for 75 mm dia including drilling holes & fixed to wall with nails etc complete all as specified and as directed. Please Enable Macros to View BoQ information |