| 1 | Dismantling plain or corrugated steel sheets any gauge thickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed. |
| 2 | S&F Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed. |
| 3 | S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 4 | M&L for Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 5 | S&F Aluminium anodised snap grid frame (Powder Coated) work of size of size 605 mm X 605 mm as in false ceiling, flat or sloping (pattern as per manufacturer's catalogue/ instructions), cutting holes for electrical fittings fixed on and including aluminium tee of size 24mmX38mmX1.50 mm as main runner, aluminium tee of size 24mmX28mmX1.50 mm as cross runner and aluminium angle of size 24mmX24mmX1.50mm at the perimeter suspended from soffit at approx 900 mm centre to centre with hangers 6 mm dia galvanised (length as per site requirement) adjusting level fixed to roof by means of ceiling cleats made out of galvanised iron flat 40 mm X 3 mm size, 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long including perforated particle board/tile 12mm thick for insulation and acoustic purpose as in ceiling flat or sloping 60cmx60cm in size including necessary scaffolding all as specified and directed. |
| 6 | M&L for Demolition of cement concrete (un-reinforced) in ground floor and paving n.exc 15 cm thick above or below ground level complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. |
| 7 | M&L for Plain cement concrete 1:3:6, nominal mix, type C-2, using 40 mm graded mechanically crushed stone aggregate, 75mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved). |
| 8 | M&L for 40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates) as in levelling course, surface finished even and rough to receive top finish complete all as specified and directed. |
| 9 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubish off the premises. complete all as specified and as directed. |
| 10 | M&L for Mat finish, premium quality, joint free (edge cut), coloured/ printed Non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge. |
| 11 | M&L for Vitrified ceramic tiles 8-10 mm thick (Square or Rectangular) Polished ,double charged area of each tile not exceeding 0.36 sqm as directed by EIC, as in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 12 | M&L for Vitrified ceramic tiles 8-10 mm thick (Square or Rectangular) Polished ,double charged area of each tile not exceeding 0.36 sqm as directed by EIC , as in skirting/vertical surfaces etc , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick rendering in cement mortar 1:6 complete all as specified and directed. |
| 13 | M&L for Glazed ceramic coloured tiles of size 350x 250x 7 mm/ 450X 350X 7mm mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:3 complete all as specified and directed by Engr-in-Charge. |
| 14 | M&L Machine cut kota stone flooring 18 to 20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing incl screeding bed 20 mm thick in CM 1:4 compete all as spcd and directed. |
| 15 | M&L for Machine cut kota stone slab flooring 18-20 mm thick over but in riser, skirting, dado and pillar laid over 10 mm thick rendering in cement mortar 1:4 laid and jointed with grey cement slurry including rubbing and polishing complete all as specified. |
| 16 | M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 17 | M&L for Rounding to edges and mirror polishing,of granite/marble/kota stone complete all as specified. |
| 18 | M&L for Demolition of brick work or stonework built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings ,dressed stonework and precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. |
| 19 | M&L for Brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in built in cement mortar 1:6 all as specified & directed. |
| 20 | M&L for Brickwork with old size, straight or curved on plan exc 6m mean radius, built in built in cement mortar 1:6 Except Brick all as specified & directed. |
| 21 | M&L for Plain cement concrete 1:2:4 ( nominal mix ) type B-1 (using 20 mm graded crushed stone aggregates) as in padding over roof, lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, copings, kneelers, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork where required complete all as specified and directed. |
| 22 | M&L for Taking down cement plaster including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed |
| 23 | M&L for Rendering cement plaster 15mm thick in cement mortar 1:6 on fair faces of brick wall or on concrete surfaces, surface finished even and fair without using extra cement, all as specified. |
| 24 | M&L for Rendering cement plaster 15mm thick in cement mortar 1:4 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. |
| 25 | Supply only intergal water proofing compound, complte all as specified. |
| 26 | M&L for Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whiting complete, all as specified and as directed by Engr-in-Charge. |
| 27 | M&L for Preperation of new plastered surfaces of walls and applying two coats of 100% acrylic smooth emulsion exterior grade with silicon additives and anti-algal properties Exterior over one coat of smartcare water proof primer on walls and chajjas with 10% dilution of water including smoothing the surface with wall putty @ 2kg/ Sqm of average thickness 2mm with silicon additives and sanding these surface for removal of loose particles , complete all as specified.Note: Tint and shed of the building as directed by Engr-in-Charge. |
| 28 | M&L for Preparation of old surfaces of walls and applying one coats of oil bound distemper complete, all as specified and as directed by Engr-in-Charge. |
| 29 | M&L for Preperation of old surfaces of walls and applying two coats of 100% acrylic smooth emulsion exterior grade with silicon additives and anti-algal properties Exterior over one coat of water proof primer on walls and chajjas with 10% dilution of water including smoothing the surface with wall putty @ 2kg/ Sqm of average thickness 2mm with silicon additives and sanding these surface for removal of loose particles , complete all as specifie |
| 30 | S&F in repair Harrison rail (Curtain rail), mild steel, chromium plated with and including fixing brackets, stops, rollers etc. complete all as specified |
| 31 | S&F in repair Sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified. |
| 32 | S&F in repair Vitreous Chinaware squatting pan, ‘Orrisa pattern’ size 580 mm x 440 mm, crystal white, with cast iron ‘P’ or ‘S’ trap, front or back inlet, integral foot rest ( excl flushing cistern and flush pipe) but including provision of plain cement concrete M-15, type B-I using 20 mm graded crushed stone aggregate complete all as specified, incl making connections to trap and to flush pipe, etc and making good to floors to match existing, all as specified. |
| 33 | S&F in repair PVC valve less, crystal white, syphonic action type flushing cistern 10 litre capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long and 32 mm dia 45 cm long PVC connection with CP brass coupling nuts and PVC washers at both ends fixed, complete all as specified. |
| 34 | S&F in repair Brass Chromium Plated, wall mixer for mixing hot & cold water screwed down for iron pipe and fixed 15 mm bore, (Suitable for sink/bathroom) complete all as specified and directed. |
| 35 | S&F in repairs Stop valve/Angle Valve cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 15mm bore iron pipe or for unions complete, all as specified. |
| 36 | S&F in repairs Bib tap, cast copper alloy ,chromium plated, fancy type , screwed for iron pipe or for brass ferrule of 15 mm bore,complete all as specified and directed. |
| 37 | S&F in repairs Brass chromium plated tubular towel rail 20 mm dia, \\"D\\" type, 60 cms long between flanges with and including chromium plated brass brackets, brass screws complete all as specified |
| 38 | S&F in repairs 600x450 mm bevelled edge mirror 5 mm thick of slected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screwed and cup washers.complete all as specified. |
| 39 | S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450mm fixed in repair complete all as specified and directed. |
| 40 | S&F in repairs Brass chromium plated shower rose 125mm size with or without swivel joints, including fixing to steel pipe or union. complete all as specified. |
| 41 | S&F G I tubing medium grade of 15 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor/trenches, including taking down old GI tubing complete all as specified and directed. |
| 42 | S&F G I tubing medium grade of 20 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor/trenches, including taking down old GI tubing complete all as specified and directed. |
| 43 | M&L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as specified. |
| 44 | S&F Rotational moulded high Density polyethylene water storage tank 500 Ltrs and conforming to IS, hoisted and fixed in position including dismantling of old water tanks capacity exc 250 ltrs but n.exc 500 ltrs in any position and removing from the site or to store complete all as specified. |
| 45 | S&F in repair Ball brass valves, 20mm bore high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified. |
| 46 | S&F in repair CP Stop valves cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 20mm bore iron pipe complete, all as specified. |
| 47 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 48 | S&F Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe 410 -W (Gde-E- 250) quality-B, complete all as specified and as directed. |
| 49 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. |
| 50 | Box type Steel windows comprised of tubular frame and shutters made out of 1.25 mm thick M.S sheet tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire cloth and glass panes only shall be measured and paid separately) with side hung shutters with steel handle and steel peg stay dovetailed or welded incl 2 Nos. tower bolts 150 mm long for each leaf and 10 mm square bar grills at spacing as shown on drg welded to F.I frame work, including other fittings; hinges, handles, tarred hold fasts, PCC blocks etc all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 51 | S&F Stainless steel wire cloth 0.40 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 52 | Sheet glass,3 mm thick glass ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed. |
| 53 | M&L for Preparation of steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 54 | M&L for Taking down and removing chowkats with shutters (without taking off shutters from chowkat) not exceeding 1.50 Sqm each complete all as specified and directed. |
| 55 | M&L for Taking down and removing chowkats with shutters (without taking off shutters from chowkat) exc 1.50 Sqm but not exc 4.00 Sqm each complete all as specified and directed. |
| 56 | S&F Pressed steel frame using 1.25 mm thick PBI sheet (size of frame 105 x 60 mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock/ strike plate etc and filling with PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in back of chowkats complete all as specified. |
| 57 | S&F Pressed steel frame using 1.25 mm thick PBI sheet (size of frame 125 x 60 mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock/ strike plate etc and filling with PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in back of chowkats complete all as specified. |
| 58 | S&F 2nd class hardwood (Sal) plain solid straight chowkats and frames wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 59 | S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.(Make: Swastik, ply wood, Century Plywood or equivelent as approved) |
| 60 | S&F 35 mm thick 2nd class hard wood (Sal/Hollock) glazed & skeleton factory made shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass, etc, sizes of members of door shutters as specified in SSR- 2009 Part-I Section 8.24(a) complete all as specified and directed. |
| 61 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as shown on page No 176 to 183 of MES SSR 2020 Part-II compete all as specified and directed. (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) |
| 62 | S&F Factory Made Solid PVC Moulded Door Shutter, with wood free EPS particle board core,28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawinge,as shown on page No 176 to 183 of MES SSR 2020 Part-II compete all as specified and directed. |
| 63 | S&F Aluminium anodized barrel tower bolt of extruded section of size 200 mm and fixed complete all as specified and directed. |
| 64 | M&L Aluminium handles, cast type, anodised of size 150 mm complete all as specified and directed. |
| 65 | S&F 250mm long aluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. |
| 66 | S&F for 300mm, Mild Steel, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 67 | M&L for Preparation of new wooden surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 68 | S&F 18/19mm thick Block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work, complete all as specified. |
| 69 | S&F 100mm size, Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed. |
| 70 | Demolition and breaking up 75mm/110 bore drain pipe (Salt glazed ware, AC or Reinforced concrete, PVC) set in cement mortar complete all as specified and directed. |
| 71 | S&F of 110mm dia PVC(SWR) pipe single socketed with rubber ring joints, laid/fixed to trenches or in floor or walls, fixed in repair complete all as specified and directed. |
| 72 | S&F of 75mm dia PVC(SWR) pipe single socketed with rubber ring joints, laid/fixed to trenches or in floor or walls, fixed in repair complete all as specified and directed. |
| 73 | S&F PVC (SWR) 110mm bore (dia), Bends any type, with disminishing pieces or tapers and Jointing with Solvent Cement, complete all as specified and as directed. |
| 74 | S&F PVC (SWR) 75mm bore (dia), Bends any type, with disminishing pieces or tapers and Jointing with Solvent Cement, complete all as specified and as directed. |
| 75 | S&F 75 mm dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 76 | M&L for 75mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) as in sub base complete all as specified and directed. . |
| 77 | M&L for Chequered cement concrete coloured tiles, homogenious texture glossy finished , chemically coated machine pressed 20 cm x 20cm x 25mm thick set, jointed and pointed in near cement slurry in floor with grey cement and pigment and including 15 mm thick cement screed in cement mortar 1:4 complete all as specified and directed. |
| 78 | Taking down point wiring with aluminium/ copper conductor for light point, socket point/ power point etc. in PVC casing and caping, surface pvc/ steel conduits, wood batten with clips including taking down board any type and size complete with any type of switches, sockets, holders, (batten or pendent type), ceiling rose etc. The light fittings (any type), main switches, distribution board with MCB’s of any capacity and make are to be removed/ replaced if required and all as specified and directed. NOTE: - Existing fan regulator any type (Where required) and electric meters are to be refixed and connected properly where required. |
| 79 | M&L for Point wiring with 1.5 Sqmm copper conductor FRLS (Multistrand) PVC insulated ISI Marked unsheathed cable in and including PVC concealed (concealed wiring) conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marking, medium grade, ISI marked with all fittings/ accessories as specified in preamble 1 (a) to (q) of Section 19 of SSR Part-II, under heading point wiring, cutting chases, making good in cement mortar in CM (1:3), finishing surfaces to match with existing and also including PVC insulated ISI marked unsheathed 1.5 Sqmm copper multistranded conductor FLRS as earth wire (green colour) connected to common earth dolly for modular fitting, modular box sunk for mounting of switches, sockets, fan regulators, light fittings etc. for one light point or one fan point through regulator or one bell point, controlled by one way switch/ push button complete all as specified and directed. |
| 80 | All as per serial item No '79' above, but for one 3 pin 5 Amps socket outlet on the same board all as specified and directed. |
| 81 | All as per serial item No '79' above, but for one 3 pin 5 Amps socket outlet, independent all as specified and directed. |
| 82 | All as per serial item No '79' above, but for one light point controlled by two way switch all as specified and directed. |
| 83 | All as per serial item No. '79' above but for 3 pin 16 Amps socket out let independent with 4 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 4 Sqmm stranded copper conductor cable as continuous earth wire, all as specified. |
| 84 | Supply and fix Modular switch 1 way 6A, 1 module, all as specified. |
| 85 | Supply and fix Modular switch 2 way 6A, 1 module, all as specified. |
| 86 | Supply and fix Modular switch 1 way 16A, 1 module, all as specified. |
| 87 | Supply and fix Modular Socket, 5/6 A - 2/3 pin combined 2 module, complete all as specified. |
| 88 | Supply and fix Modular Socket 6A/16A - 2/3 pin combined 2 module, all as specified. |
| 89 | Supply and fix Modular Bell push 6A 1 module, all as specified. |
| 90 | Supply and fix electrical Bell ding dong type, AC, 230 volts, single pole all as specified. |
| 91 | Supply and fix Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified. |
| 92 | S & F LED light fitting inverter type 1X20 watt Wall mounted, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge. |
| 93 | S & F LED light fitting mirror inverter type with high out put diffuser 2 feet, 10 watt 220 V. AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge. |
| 94 | Supply & Fixing 35Watt New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. connecting with PVC insulated three core flexible copper conductor of suitable size to fitting including bracket made up of 32mm dia GI pipe light grade 1.5 metre long and bent to shape required, complete all as specified. |
| 95 | Supply & Fixing Replacement of Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar with fixing arrangements including taking down ICDP/DB's any type including taking down of kitkat fuse/MCB SPN/SP as directed by Engineer-in-charge. |
| 96 | Supply & Fixing Replacement of Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 4 way, double door, 240 volts with 200 Amp rated bus bar with fixing arrangements including taking down ICDP/DB's any type including taking down of kitkat fuse/MCB SPN/SP as directed by Engineer-in-charge. |
| 97 | Supply & Fixing MCB SPN 32 Amp, 240 Volts, B Curve , 10 KA all as specified. |
| 98 | Supply & Fixing MCB SP 6 to 32 Amp, 240 Volts, B Curve , 10 KA all as specified. |
| 99 | M&L for Sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded RLS conductor of size 6.00 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 6 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes 1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly including taking down old unservicable submain wiring, complete and as directed. Note :-(i) Two run (each run of 1 RM) of 6 sqmm copper conductor and one RM of earth wire of 6 Sqmm, shall be measured as one RM). (ii) The rate for concealed type point wiring shall deemed to include the cost of cutting, chasing in wall by using electric cutter and making good the disturbed surface of wall by providing cement plaster and matching the surface by white wash /colour wash all as per existing finishes complete. |
| 100 | M&L for Sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded RLS conductor of size 2.5 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 2.5 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes 1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly complete and as directed. Note :- Two run (each run of 1 RM) of 2.5 sqmm copper conductor and one RM of earth wire of 2.5 Sqmm, shall be measured as one RM).(ii) The rate for concealed type point wiring shall deemed to include the cost of cutting, chasing in wall by using electric cutter and making good the disturbed surface of wall by providing cement plaster and matching the surface by white wash /colour wash all as per existing finishes complete. |
| 101 | M&L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. |
| 102 | M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25X4 mm size (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. |
| 103 | S&F in Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexognal .head screw all as specified. |
| 104 | S&F in replacement Aluminum strip 25x3.15mm fixed with porcelain/PVC saddles and fixing screws etc minimum two number saddles with screws on and including PVC gutties in each one metre length , for roof conductors and down conductors above ground, fixed in reapair , complete all as specified. |
| 105 | S&F in replacement Air termination single pointed aluminum rod 12mm dia and 300mm long and fixed including taking out old air termination rod, complete all as specified and directed. |
| 106 | S&F Sheet metal enclosure with 3 pin plug and socket with SP20 Amp all as specified and directed. Please Enable Macros to View BoQ information |
| 107 | S&F Sheet metal enclosure with 3 pin plug and socket with SP20 Amp all as specified and directed. Please Enable Macros to View BoQ information |