| 1 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings sheets in roof coverings complete. |
| 2 | Dismantling structural steel work including doors, gates but excluding framed truss etc. |
| 3 | Demolition of wall and ceiling boards, fibre pulp insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets,all as specified. |
| 4 | Taking down chowkats or frame with shutter (without taking off shutter from the frame) n.exc 1.5sqm each |
| 5 | Taking down chowkat or frames with shutters (without taking off shutters from the frames)exceeding 1.5 Sqm and not exceeding 4 Sqm each complete all as specified. |
| 6 | Demolition of stone slabs and tiles of any description or thickness in floors & wall, laid bedded & pointed in any mortar. |
| 7 | M&L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws incl ridge all as specified and directed . |
| 8 | M&L for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in ridge of roof covering/ cladding to wall, fixed with self tapping screws incl ridge all as specified and directed . |
| 9 | S&F structural steel work as in roof trusses, purlins, rafter, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-290-W (Gde-E-165) quality B complete all as specified. |
| 10 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles with semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles of size 595x595 mm of approved texture , design and patterns having moisture content less than 2% , humidity resistance of 99%, NRCO 0.50 to 0.75 as per IS 8225;1987 , Noncombustible as per BS 476 (part4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 grams per Sqm including both sides) comprising of main T-runners of size15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per Sqm) i.e 50 mm long , 8mm outer dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm, galvanized iron perimeter wall angle of 24x24x0.40 mm length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. the work shall be carried out as per specifications, drawing and as per complete all as specified & directed. |
| 11 | M & L for 25 mm thick cement concrete in flooring type Bo, 1:2:4 (12.5mm graded aggregate) with liquid water proofing compound as per manufacturers instructions for laying floor tiles. Note (WPC will be measured and paid separately). |
| 12 | M&L for 20-25 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20mm thick screed bed in cement and sand mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 13 | M&L for 20-25 mm thick machine cut kota stone slab as in skirting or certical surface jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 10mm thick back coat in cement and sand mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 14 | M&L for Virified Ceramic tiles 9 to 10 mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm,as in floors etc set over and including high performence adhesive manufactured by somani ezifix tile adhesive or equivalent mixed in cement as per manufacturer instruction and jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile color including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with CM 1:4 (Tile pattern and decoration may be as suggested by Engineer-in-charge). |
| 15 | M&L for Virified Ceramic tiles 9 to 10 mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including backing coat 10 mm thick in CM 1:3 compelte all as specified and directed. |
| 16 | M&L mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or othercovering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steelsheeting or other covering, running rails and guides) and hanging; also fastening and fixing completet complete all as specified and directed. |
| 17 | M & L Cement concrete type B1, 1:2:4 (20 mm graded stone aggregate) as in coping, bed plate for hold fast etc. |
| 18 | M&L for 35mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, comercial type 1.0mm thick (veneered on both side) with decorative choice laminated type 1 (factory laminated), or surface finish, 6mm thick or external teak wood lipping fixed with nails, color and pattern as approved by EIC/GE. |
| 19 | S & F 35mm thick 2nd class Hard wood Glazed and Skelton shutters, open rebated and prepared to receive glass, gauze etc(without sash bars) edges of framing plain, chamfered or rounded, fitted with cut ,mitered and moulded beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. |
| 20 | S&F of Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 21 | S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket and including necessary locks/handels etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per the directions of Engineer-in-charge. |
| 22 | S&F 4.00mm thick sheet glass, selected quality with solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers and glazing with rubber beading or with glazing clips, all as specified and directed. |
| 23 | M&L for preparation of new steel surfaces of any description exc 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. |
| 24 | S&F mild steel cold rolled butt hinges medium weight 100 mm long complete all as specified. |
| 25 | S&F 200mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and as directed by Engineer-in-Charge. |
| 26 | S&F aluminium handles cast type anodised of size 200mm long ISI marked complete all as specified and as directed by Engineer-in-Charge. |
| 27 | S & F 250 mm aluminium alloy anodised sliding door bolts, with hasp and staple (bolt type) not less than 12mm dia with and and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolt of extruded section or cast aluminium and fixed to wooden door shutters |
| 28 | M & L in repair for mild steel Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework (caging) of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 29 | Demolition of brick work or stone masonry built in cement mortar including all quoines arches,pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles, all as specified . |
| 30 | M & L for Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in CM 1:6, complete all as specified and directed complete all as specified and directed. |
| 31 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified. |
| 32 | M & L for rendering in two layer on fair faces of brick work or concrete surfaces of wall 5 mm thick in CM 1:4 mixed with WPC as per manufacturer's instructions of cement for fair finished over 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 33 | M&L for rendering 10 mm thick cement plaster on brick/concrete surfaces etc in cement mortar 1:4 and finished even and smooth without using extra cement all as specified and directed. |
| 34 | Supply Only integeral water proofing compound. |
| 35 | Supplying and fixing galvanized iron chicken wire mesh of approved quality, 20 gauge (approx. 0.9 mm), with mesh size not exceeding 25 mm x 25 mm, securely fixed with nails, screws, or staples over the existing cracks and extending a minimum of 75 mm on either side of the crack all as specified and directed. |
| 36 | M&L for complete removal of existing treatment and applying one coats of alkali resitant primer and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty on wall complete all as specified and as directed. |
| 37 | M & L preparation of newly plastered surfaces of walls and applying two coat of oil bound distemper over one coat of primer ove a coat of 1 mm thick water proof wall care putty, complete, all as speicfied and directed. |
| 38 | M&L for complete removal of all existing treatment and preparing surfaces of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engineer - in – Charge |
| 39 | M&L for preparation of new plastered surfaces of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engineer - in – Charge |
| 40 | M&L for anti-termite treatment by treating the soil under plinth protection at the rate of 5 liters of emulsion per square metre of surface area complete all as specified and directed by the Engr-in-Charge. |
| 41 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for fair finished surface complete all as specified and directed by Eng-In-Charge |
| 42 | M&L for Reinforced cement concrete (nominal mix) Type B1 (1:2:4) with 20mm graded stone aggregate as in beams all as specified and directed by Eng-In-Charge |
| 43 | Supply and fix TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge. |
| 44 | Supply and fix TMT bars 6 to 8 mm dia, as in stirrups cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge. |
| 45 | M & L for 16 to 18 mm thick machine cut green marble stone as in floor, steps (in single piece), cooking platform, cills of window etc laid over 15 mm thick cement screed and jointed with base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including15mm thick plaster in cement mortar 1 : 4 complete all as specified and as directed. |
| 46 | Demolition of cement concrete (unreinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level) complete all as specified. |
| 47 | M&L for providing 75mm thick PCC 1:3 :6 type C-2 using 40mm graded crushed stone aggragate as in plinth protection all as specified. |
| 48 | M & L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, over cement screed base 20 mm thick in cement morter 1:6, set, jointed and pointed in neat cement slurry in floors etc complete as directed. |
| 49 | Taking down carefully copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs, & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor etc. |
| 50 | Taking down main switch, DB/change over/VTPN, MCCB AC box of any capacity. |
| 51 | M&L for concealed point wiring with 1.5 Sqmm PVC-FRLS insulated, sheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, including modular metal flush boxes & modular white cover plate with frame as per site requirement all fittings such as tees, bends, elbows, etc. of External diameter 20mm all as per site requirements PVC insulated & sheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete incl cutting and chasing in stone/brick masonry all as specified and directed by Engr-in-charge . |
| 52 | For one light point controlled by one switch |
| 53 | For one fan point controlled by one switch |
| 54 | For one 5 Amp independent socket point controlled by one switch |
| 55 | For one 3 pin ,5 Amp socket point with other switch on the same board |
| 56 | All as per item No 51 here in before but for power point wiring using with 2.5 sqmm PVC-FR LS insulated ,sheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,sheathed, copper conductor stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed by engir in charge. |
| 57 | S&F Modular switch, one way, 6 Amp 230, 1 module all as specified and directed by Engr in charge. |
| 58 | S&F socket Modular 6 Amp-2/3 pin combined 2 module all as specified and directed by Engr in charge. |
| 59 | S&F switch Modular, single pole, one way,16 Amp ,1 module 230 Volt all as specified and directed by Engr in charge. |
| 60 | S&F socket modular 6/16 Amp, 2/3 pin combined ,2 module 230 Volt . all as specified and directed by Engr in charge. |
| 61 | S&F ceiling rose, surface backlit,three terminal. all as specified and directed by Engr in charge. |
| 62 | S & F of BLDC White colour ceiling fan complete with blades electronic regulator , down rod and accesories from existing roof / trus to fall ceiling, and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE,Winding material 100 % copper ,350RPM air velocity 215m3/min,anti rust blades five star rated with brushless direct current motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV ceiling fan complete all as specified and directed.Note : 1) Old ceiling fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc.2). 02 years guarantee to be provided by the contractor. |
| 63 | Supply and fixing LED batten lights fitting made of Aluminium extrusion 1x 20W (4 feet) , input voltage 140-270 V AC,CCT 6500K, Lumin efficency 100 lm/watt ,surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 , connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr -in -charge. Including Taking down old Tublight fittingsNote :-Warrenty on light should be of minimum 02 Years provided by the contractor. |
| 64 | Taking down and Supplied & fixed MCBs DB TPN 4 way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240/430V complete all as directed by Engr-incharge. |
| 65 | S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 8 way 240 V with 200 amps rated bus bar fixed on wall complete with all acessories including taking down old unserviceable MCB DB with MCBs complete all as specified and directed |
| 66 | S & F MCB single pole, having rupturing 10KA, 6 amps to 32 amps as ordered 240 Volts |
| 67 | S & F MCB Single pole and neutral (SPN), having rupturing 10KA, 240 V 63 amps as ordered. |
| 68 | S & F MCB Triple pole and neutral (TPN), having rupturing 10KA, 240/415 V 63 amps as ordered. |
| 69 | M&L concealed sub main wiring with two single core PVC FRLS insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 4 sqmm (for main current) drawn in & incl PVC conduit not less than 25mm dia ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 4 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as directed by Engineer-in-Charge Note : One length of PVC Conduit and 3 run of cable shall be measured and paid as one length. |
| 70 | S & F of Inverter LED street light fitting 35 Watt 230 V AC CCT 5700K Lumens ≥100 lm/watt outdoor type with high pressure die cast Aluminium housing high power led as lighting source and lens embedded pc cover having top opening seperate driver compantment and impact resistance of IK 07 WITH 10KV,OEM driver,PF 0.9, built in surge protection device heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection . including bracket made out of GI pipe light grade 32mm bore not less than 1.20m long bent to shape required fixed to pole with suitable size 2 Nos clamps made out of 25X3mm flat iron with nut, bolts and washers complete complete all as specified and directed.Note :- The warranty on light should be minnimum of 2 Years provided by the contractor. |
| 71 | Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.5 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron medium grade pipe 40mm bore in wall/floor/and GI Pipe 20 mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009 ( Part-I).Notes :-(a) The unit rate shall include for GI protection pipe, GI watering pipe, wire mesh, funnel and excavation, RCC pit cover, test point, galvanised iron strip from top of earth plate upto 7.5 metres above ground level and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made.(b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate.(c) If the testing result of earthing work is not found satisfactory then the contractor shall do another earthing work at his own cost and nothing shall be permissible on this account.(d) Earthing work will be carried out in presence of MES representative. |
| 72 | Taking down old existing fitting any type and S & F of recess / surface mounting LED flat panel 2'X2' made of sheet steel housing duly powder coated with high efficient LEDs & glare free full opal diffiuser, IP20 of capacity 36 watt ,input voltage 140 -270 V AC , CCT 5700 K,lumin efficency 120lm/watt, surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 ,complete all as specified and directed. Note Warrenty on light should be of minimum 02 Years provided by the contractor. Please Enable Macros to View BoQ information |