Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work excavation of foundation in hard soil within initial lead of 50m and initial lift of 1.5m including dressing the sides, leveling the bed and depositing the excavated materials away from the work site, shoring etc if required, complete the item of work in all respect as per direction of the Engineer-in-charge. |
| 2 | Extra for every additional lift of 1.5 m or part there of in excavacation / banking excavated or stacked materialsOrdinary Soil |
| 3 | Filling foundation and plinth with filling sand laying in layers including ramming, watering, compacting including cost, conveyance and royalty of sand from approved quarry and other taxes if any with all leads, lifts, T&P etc complete the items of work in all respect as per specification and direction of Engineer in charge. |
| 4 | Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m. |
| 5 | Supplying,diluting and preparing chemical emulsion like CHLOPYRIPHOS or other chemicals approved by Central insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as pre-constructional anti termite treatment and creating a chemical barrier under and around wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building. Surrounding the pipes and condults etc. complete at the rate of 7.5 litres ( or as directed by the manufacturer) per sqm on vertical and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150 mm center to center etc. complete as per IS:6313/1981 ( Part-II) and as per the direction of Engineer-in-Charge including all cost of materials labour, taxes, etc. all complete. |
| 6 | CC (1:3:6) using 40 mm size and down graded crusher broken HG stone metal free from weathered surface of approved quality from approved quarry in foundation and plinth including laying concrete in layers with due compaction, watering and curing including cost, conveyance, royalty and taxes of all materials with all lead, lifts and delifts, T&P etc required for completion of the work in all respect as per direction of the Engineer-in-charge. |
| 7 | Brick work with Flyash bricks of size 23 cm X 11 cm X 8 cm having crushing strength between 100 kg/cm2 to 149 kg/cm2 in cement mortar (1:6) in foundation & plinth including cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge. |
| 8 | Brick work with Flyash bricks of size 23 cm X 11 cm X 8 cm having crushing strength between 100 Kg/cm2 to 149 kg/cm2 in cement mortar (1:6) in superstructure including cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge.Ground Floor |
| 9 | 1st Floor |
| 10 | 2nd Floor |
| 11 | Terrace Floor |
| 12 | Brick work with Flyash bricks of size 23 cm X 11 cm X 8 cm having crushing strength between 100 Kg/cm2 to 149 kg/cm2 in cement mortar (1:4) in Foundation & Plinth including cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge.Ground Floor |
| 13 | 1st Floor |
| 14 | 2nd Floor |
| 15 | RCC work of M-25 grade with 20 mm and down grade black hard granite chips including cost, conveyance, royalty and all taxes of all materials with all leads, lifts, T&P etc. including rigid and smooth centering, shuttering and dismantling the same after the curing of RCC work for 28 days complete the item of work in all respect as per specification and direction of Engineer-in-charge.Column base & Footing |
| 16 | Plinth Bend |
| 17 | Column & BeamGround Floor |
| 18 | 1st Floor |
| 19 | 2nd Floor |
| 20 | Terrace Floor |
| 21 | Lintel BendGround Floor |
| 22 | 1st Floor |
| 23 | 2nd Floor |
| 24 | Terrace Floor |
| 25 | Chajja & loftGround Floor |
| 26 | 1st Floor |
| 27 | 2nd Floor |
| 28 | Roof SlabGround Floor |
| 29 | 1st Floor |
| 30 | 2nd Floor |
| 31 | Terrace Floor |
| 32 | Staircase excluding landing but including railingGround Floor |
| 33 | 1st Floor |
| 34 | 1st Floor |
| 35 | Staircase excluding landing but including railingGround Floor |
| 36 | 1st Floor |
| 37 | 1st Floor |
| 38 | Labour charges for straightening coiled or bent up MS rods including cutting, bending and welding if required and tying the grills, laying and placing in proper position as per design including cost, conveyance, taxes etc of tested MS/TS rod with testing data of required specification & cost of binding wires of 18 to 20 gauge, labour, T&P required for the work complete and as per the specification and direction of the Engineer-in-charge.Foundation |
| 39 | Ground Floor |
| 40 | 1st Floor |
| 41 | 2nd Floor |
| 42 | Terrace Floor |
| 43 | Supplying of M.S Doors, Window with grills, Grills,Collapsible gates made out of M.S Angle frame, M.s Flat Sheet etc. of approved section and design, electrically welded properly with all necessary locking arrangement and one coat redoxide primer including cost of all materials, labour, T&P, carriage of materials to site etc. complete as per the direction of the Engineer-in-charge.Collapsible Gate / Window Grill ( Ground Floor / 1st Floor / 2nd Floor) |
| 44 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mmx32mmx2mm @ 0.90m C/C and stainless square pipe bracing of size 32mmx32mmx2mm in 3 rows in staircase as per approved design and specification, buffing, polishing etc. with cost, conveyance, taxes of all materials, labour, T&P etc. required for completion of work in all respect as per direction of Engineer-in-charge. Ground Floor / First Floor / Second Floor |
| 45 | Supplying, fitting and fixing of window (sliding type) made up Aluminium section 9778 as window frame, section no. 4095,4096 and 9777,3994 as shutter frame with 5mm thick glasss as panel fitted with rubber beading including locking arrangement including all fitting including cost of all material, taxes labour T&P including cost of glass etc. complete as per direction of Engineer-in-charge. |
| 46 | Supplying fitting fixing of factory made single leaf rigid F.R.P composite door shutter of 32 mm thick laminated with G.P.P skin with wood grain finished etc. as per directio nof Engineer-in-charge. |
| 47 | Providing and fixing of WPC Door Frames with Rebate cuts and Finished cross section size 75mm x 45mm or 90mm x 50mm including cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, staging, watering and curing, T&P etc. complete as per the direction of the Engineer-in-charge. |
| 48 | Providing and fixing of 30mm thick WPC door shutter with hinges, tower bolt, handle, stainless steel screws etc. including the cost of all materials, hardware fittings, cost of all labour, conveyance, taxes, loading, unloading, T&P etc. complete as per the direction of Engineer-in-charge. |
| 49 | 12mm thick cement plaster (1:6) in cement mortar finished smooth surface on brick wall after racking out joints including watering curing to required period including cost conveyance, royalty of all materials, T&P complete etc. as per specification and direction of Engineer in charge.Ground Floor |
| 50 | 1st Floor |
| 51 | 2nd Floor |
| 52 | Terrace Floor |
| 53 | 16mm thick cement plaster (1:6) in cement mortar finished smooth surface on brick wall after racking out joints including watering curing to required period including cost conveyance, royalty of all materials, T&P complete etc. as per specification and direction of Engineer in charge.Ground Floor |
| 54 | 1st Floor |
| 55 | 2nd Floor |
| 56 | Terrace Floor |
| 57 | Finishing suface of walls with cement based wall putty (Water based ) of approved make and finished smooth and even surface to receive painting with cost, conveyance, royalty taxes of all materials labour T&P and scaffolding as required for the work and as per specification and direction of Engineer-in-charge.Ground Floor |
| 58 | 1st Floor |
| 59 | 2nd Floor |
| 60 | Terrace Floor |
| 61 | Painting two coats of synthetic enamel paint over a coat of primer of approved quality, brand and shade including smoothening the surface by sand paper and filler etc complete with cost, conveyance, royalty, taxes of all materials, labours T&P required as per specification and direction of Engineer-in-charge.Ground Floor |
| 62 | 1st Floor |
| 63 | 2nd Floor |
| 64 | Finishing to walls with two coats plastic emulsion paint over one coat primer and plastic emulsion paint of approved brand and approved colour including cleaning the surface with cost, conveyance, royalty taxes of all materials labour T&P and scaffolding as required for the work and as per specification and direction of Engineer-in-charge.Ground Floor |
| 65 | 1st Floor |
| 66 | 2nd Floor |
| 67 | Terrace Floor |
| 68 | Finishing to walls with two coats weather coat over one coat primer and weather coat paint of approved brand and approved colour including cleaning the surface with cost, conveyance, royalty taxes of all materials labour T&P and scaffolding as required for the work and as per specification and direction of Engineer-in-charge.Ground Floor |
| 69 | 1st Floor |
| 70 | 2nd Floor |
| 71 | Terrace Floor |
| 72 | Supplying, fitting and fixing vitrified tiles in floors of size 600mm x 600mm of approved make confirming to IS: 13755 laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) and filling joined with white cement of approved quality including cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge.Ground Floor |
| 73 | 1st Floor |
| 74 | 2nd Floor |
| 75 | Supplying, fitting and fixing vitrified tiles in dado, skirting and risers of steps on 12mm thick cement plaster (1:3) joint with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing, cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge.Ground Floor |
| 76 | 1st Floor |
| 77 | 2nd Floor |
| 78 | Supplying, fitting and fixing granite tiles in floors, treads on steps and landing on 25mm thick bed of cement mortar 1:1 (1 cement: 1 sand) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing, cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge.Ground Floor |
| 79 | 1st Floor |
| 80 | 2nd Floor |
| 81 | 20 mm thick grading plaster in cement mortar (1:4) over roof slab including cost, conveyance, royalty, taxes of all materials & complete work as per specification and direction of Engineer in charge.2nd Floor |
| 82 | Terrace Floor |
| 83 | PH & SANITARY WORKSINTERNAL PHSupplying all materials, labour and T&P for fitting and fixing white glazed vitreous china porcelain Indian Pan water closet of size 23\\" of approved make confirming to IS-2556 and top inlet for sinking into floor with 100mm PVC 'P' trap etc. including supply of necessary cement concrete for fitting the closet etc. complete in all respect in all floors including cost, conveyance and taxes of all materials etc. complete and as per PH specification and direction of Engineer-in-charge. |
| 84 | Supplying all materials, labour and T&P for fitting and fixing white glazed vitreous china porcelain flat back urinal pan of approved make confirming to IS-2556 and top inlet for sinking into floor with 100mm PVC 'P' trap etc. including supply of necessary cement concrete for fitting the closet etc. complete in all respect in all floors including cost, conveyance and taxes of all materials etc. complete and as per PH specification and direction of Engineer-in-charge including marble partition in between urinals. |
| 85 | Supplying all materials, labour, T&P and fixing standard sized shower (bath shower) of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in- charge. |
| 86 | Supplying all materials, labour and T&P for fitting and fixing white glazed vitreous china porcelain wash basin of size 450mm x 300mm of approved make confirming to IS-2556 and top inlet for sinking into floor with 100mm PVC 'P' trap etc. including supply of necessary cement concrete for fitting the closet etc. complete in all respect in all floors including cost, conveyance and taxes of all materials etc. complete and as per PH specification and direction of Engineer-in- charge. |
| 87 | Supplying all materials, labour, T&P and fixing standard sized CP Bib cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 88 | Supplying all materials, labour, T&P and fixing standard sized 15mm dia Angular Stop cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in- charge. |
| 89 | Supplying all materials, labour, T&P and fixing standard 15mm sized pillar cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 90 | Supplying all materials, labour, T&P and fixing standard sized Long body 15mm dia CP Bib cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in- charge. |
| 91 | Supplying all materials, labour, T&P and fixing standard sized two way CP Bib cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in- charge. |
| 92 | Supplying all materials, labour, T&P and fixing standard sized shower (Health Faucet) of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in- charge. |
| 93 | Supplying all materials, labour, T&P and fixing standard sized CP soap Dish holder of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 94 | Supplying all materials, labour, T&P and fixing standard sized Chromium Plated brass towel rail complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge |
| 95 | Supplying all material, labour, T&P and fixtures for providing and fixing of stainless steel sink of size 600 x 450 x225mm of approved make with its components like 40mm CP waste of cat no ALD 709, 40 mm waste pipe etc. including all requisite fixing materials complete as per the PH specification and direction of Engineer-in-Charge. |
| 96 | Supplying all materials, labour, T&P and fixing standard sized sink cock of florentine single lever quatertum of approved make complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of the Engineer-in-charge. |
| 97 | Providing and fixing circular type stainless steel jalli (grating) with hole for floor /nahani trap etc complete as per PH specification and direction of the engineer in charge |
| 98 | Fixing 600x450mm bevelled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with Chromium Plated brass screws and washers complete as per specification and direction of the Engineer in charge |
| 99 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge |
| 100 | Supplying all materials, labour, T&P and fittings and fixing of Poly Propelene white double layer water storage Tank of approved make confirming to IS 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc including hoisting upto terrace level and placing the tank to the required position etc all complete as per PH specification and direction of Engineer-in-charge. (To provided with brick masonary guard walls which will be paid separately)2000 Ltr. |
| 101 | Supplying all materials, labours, T&P and fitting and fixing of the following size of CPVC pipe confirming to IS 15778 certification mark with socket and screw joints in walls and floors including supplying of required number of fittings of approved make including cutting threads to pipes and pipes to length, including wastage,etc for fitting to the walls with supply of holder ats, clamps, fixing wooden plugs in walls, including testing of pipe line for water tightness complete as per IS specification including cost, conveyance and taxes of all materials all complete as per PH specification and direction of Engineer-in-charge.a) 15 mm dia |
| 102 | b) 20 mm dia |
| 103 | c) 25 mm dia |
| 104 | d) 32mm dia |
| 105 | e) 40 mm dia |
| 106 | f) 50 mm dia |
| 107 | Providing all materials, labour, Fitting & fixing of CPVC Ball Valve with CTS socket. Make : Prince)b) 25 mm dia |
| 108 | d) 32mm dia |
| 109 | e) 40 mm dia |
| 110 | e) 50 mm dia |
| 111 | Supplying all materials,labours,T&P for cutting holes through existing brickwork including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/PVC pipes and fittings etc all complete as per PH specification and direction of Engineer-in-charge. |
| 112 | Supplying all materials,labours,T&P for cutting holes through existing RCC floors & roofs including making good the damages for taking GI pipes and fittings/PVC pipes and fittings etc all complete as per PH specification and direction of Engineer-in-charge. |
| 113 | Supplyng all materials, labour, T&P for construction of brick masonary Gulley trap chamber of size300mm x 300mm with CI gulley trap, by Fly ash brick masonry in CM (1:4), CP (1:6) with 150mm x 150mm CI grating including labour and materials for fitting and fixing 100mm dia square mouth CI gully trap with supply of all jointing materials and encasing the gully trap with a block of CC (1:4:8) with 25mm size hard stone metal all complete with providing and fixing of 250mm x 250mm precast RCC cover slab including cost, conveyance, taxes of all materials to site complete as per the PH specification and direction of Engineer-in-charge. |
| 114 | Providing all materials labour, T&P for making grooves in bricks/stone masonary walls vertically or horizontally up to required depth and width in all floor for laying of pipes and fittings up to 50mm dia, testing the joints with required water pressure and making good the damages with cement concrete 1:2:4 with 12mm size h.g.c.b.chips and finished smooth with cement morter (1:4) to original shape including cost of all materials, curing, conveyance of all materials etc. all complete excluding GST as per specification & direction of Engineer-in-charge. |
| 115 | EXTERNAL PHSupplying all materials labour, T&P, fitting & fixing of 50 mm dia brass/ GM full way valve of approved make including supply of all necessary jointing materials such as red lead paint, yarns etc. including cost, conveyance & taxes of all materials, T&P etc. all complete as P.H specification and as per the direction of the EIC. |
| 116 | Supplying all materials, labours, T&P and fitting and fixing of the following size of CPVC pipe confirming to IS 15778 certification mark with socket and screw joints in walls and floors including supplying of required number of fittings of approved make including cutting threads to pipes and pipes to length, including wastage,etc for fitting to the walls with supply of holder ats, clamps, fixing wooden plugs in walls, including testing of pipe line for water tightness complete as per IS specification including cost, conveyance and taxes of all materials all complete as per PH specification and direction of Engineer-in-charge. |
| 117 | Supplying all materials & labour, T&P and constructing brick masonary chamber for water sluice valve, single air valve & non return valve with Fly ash brick masonary in cement mortar (1:4) as per approved drawing and specification CC (1:4:8) with 4cm size hard granite metal on the bed, 12mm cement plaster (1:6) to inside and cement flush pointing (1:6) to outside surface with 100mm thick RCC M20 cover slab with 20mm hg chips using required quantity of tor steel, centring and shuttering to the slab and dismantling it after 31 days of casting, filling the outside cavity with excavated materials, watering, curing including cost, conveyance, taxes of all materials, labour charges for cutting, bending, binding and tying the grills in proper position etc all complete as per drawing, design and direction of Engineer-in- charge.Chamber (0.75x0.75x0.7mtr) |
| 118 | Supplying all materials, labour, T&P and fitting and fixing of double air valve of 50mm Dia confirming to the relevant IS specification and dimension including fixing it in position along the pipeline with supply of all required materials such as rubber insertion, nuts & bolts including cost of all materials, taxes, and duties, transportation charges from store to site etc all complete as per the direction of Engineer-in-charge. |
| 119 | Supply, installation, testing and commisioning of automatic star delta control panel suitable for 2HP pumpset including MS box fitted with main switch ,contactor, single phasing preventer, timer, selector switch, voltmetre, ammeter etc and connection with motor inside the sump with suitable cable etc complete as per the Direction of Engineer-in-charge. (Excluding power supply)(MR) |
| 120 | SEPTIC TANKEarth work in excavation in Hard rock by mechanical means (Hydraullic excavator)/ manual means overareas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) inculding disposal of excavated earth up to 50 m and lift upto 1.5m with all lead and lift including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, T & P required for the work complete as directed by the Engineer- in- charge. |
| 121 | Earth work excavation beyond 1.50mtr depth |
| 122 | Supplying and filling the Foundation & Plinth with clean coarse river sand of approved quality from approved quarry, laying in layers not exceeding 150mm thick, watering and ramming including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge. |
| 123 | Providing and laying P.C.C (1:3:6) using 4 cm size metal etc. in foundation and floors uding cementn 40 mm size crusher broken H.G Metal and screened and washied sharp river sand for mortar of approved quality and from approved quarry including hoisting, lowering and laying concrete to the required level. ramming, watering and curing, etc. complete in all respect as per direction of the Engineer-in-charge. |
| 124 | Providing and laying in position ready mixed M25 grade concrete having compressive strength at 28 days test not lessthan 250kg/sq.cm for reinforced cement concrete work using cement content as per approved design mix etcFoundation |
| 125 | RCC Wall |
| 126 | Cutting,straightening coiled or bent up HYSD/TMT Reinfocement Bars welding or jointing if necessary ,bending, binding,tying the grills as etc |
| 127 | Providing 12mm. thick cement plaster with cement mortar of mix (1:6) in all floors cement and with screened and washed sharp sand for mortar with neat cement punning finished smooth to brick/RCC walls after racking out the joints including watering and curing complete with cost, etc |
| 128 | Providing & applying cement punning over cement plaster |
| 129 | Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m. |
| 130 | Soak PitSupplying and filling the Foundation & Plinth with clean coarse river sand of approved quality from approved quarry, laying in layers not exceeding 150mm thick, watering and ramming including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge. |
| 131 | Providing & laying cement concrete of prop. (1:4:8) in foundation bed and floors using 40mm nominal size down graded, screened, washed hard black crusher broken granite metal of approved quality & from approved quarry including laying in the layers not exceeding 100 mm thick, etc |
| 132 | Providing and laying in position ready mixed M25 grade concrete having compressive strength at 28 days test not lessthan 250kg/sq.cm for reinforced cement concrete work using cement content as per approved design mix etcFoundation |
| 133 | Providing 12mm. thick cement plaster with cement mortar of mix (1:4) in all floors cement and with screened and washed sharp sand for mortar with neat cement punning finished smooth to brick/RCC walls after racking out the joints including watering and curing complete with cost, etc |
| 134 | Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Foundation & Plinth having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 135 | Supplying all materials, labours, T&P & fitting & fixing U-PVC SWR soil waste ventilating pipes & fittings of the following outside diameter confirming to IS: 4985/2000 to wall with nail, bobbins and woden plug or laying in trenches including jointing with supply of approved rubber lubricant by non heat appplication method as per manufacturer's specification, testing etc. complete as per specification and direction of the Engineer-in-charge. (Eath work in excavation in all kinds of soil and refilling of trenches to be measured and paid separately) Pipe 110 mm dia |
| 136 | 110mm x 110mm 'P' trap ( Make - Astral) |
| 137 | 110mm x 87.5\\" Plain Bend |
| 138 | 110 mm x 87.5 Door Bend |
| 139 | 110 mm x 45\\" Plain bend |
| 140 | 110 mm dia single Y withoutdoor |
| 141 | 110 mm WC connector / Bend with lip ring |
| 142 | 110 mm socket plug |
| 143 | 100 mm Pushfit Coupler |
| 144 | UPVC Tee ( 150 x 150 x 150) mm |
| 145 | UPVC Elbow |
| 146 | Supplying, fitting and fixing of Antiskid Ceramic Floor Tiles in flooring using special plain / printed series Ceramic Floor Tile of premium grade ( having minimum thickness 7 mm to 8 mm & size 300 mm x 300 mm OR 600 mm x600 mm, confirming toI.S 13755 of approved quality and shade in floors, treads on steps and landings on 25 m.m thick bed of cement mortar of mix (1:1) laid in proper slope and gradient with screened & washed sharp etc.Ground Floor |
| 147 | 1st Floor |
| 148 | 2nd Floor |
| 149 | Supplying, fitting and fixing of ceramic glazed wall Tiles in skirting dado,risers of step and wall using special plain / printed series Ceramic wall Tile of premium grade ( having minimum thickness 6.5 mm to 6.7 mm & size 300 mm x 300 mm OR 600mm x300 mm, Ground Floor |
| 150 | 1st Floor |
| 151 | 2nd Floor |
| 152 | INTERNAL ELECTRIFICATIONRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZH PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/ HAVELLS/RR KABLE/KEI with 20 mm dia PVC non metallic heavy duty conduit FRLS type ISI marked Make-AKG/BEC/Precision/Norpack 6A modular type ( flame retradant type) switch ISI marked Make-Schneider (Zencelo) /legrand( Myrius) /Panasonic (vision)/Eq. and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type) Make-Schneider (Zencelo) / legrand( Myrius) / Panasonic (vision)/Eq. of suitable size, modular box with 1.5 sq. Mm FRLSH PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. Group-A. |
| 153 | Group-B. |
| 154 | Group-C. |
| 155 | Group-C. |
| 156 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider (Zencelo) / legrand( Myrius) /Panasonic (vision)/Eq. (Maximum 02 nos point in one circuit). |
| 157 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) /Eq. (Maximum 02 nos point in one circuit). |
| 158 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)( flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider ( Zencelo ) / legrand ( Myrius) / Panasonic (vision)/Eq. (For equipment power). |
| 159 | Wiring for twin control light point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in recess PVC conduit with 2 way modular switch with ISI marked, modular base of suitable size ISI marked with metal box(18 SWG) and earthing point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor for loop earthing etc as required. |
| 160 | Recess wiring for circuit/submain wiring with the following mentioned size PVC FRLSH / LSZH insulated, copper conductor, single core cable Make- Finolex / Anchor / Polycab / HAVELLS / RR KABLE / KEI in recessed PVC conduit Heavy duty FRLS of mentioned size Make-AKG / BEC / Precision/Norpak as required as per direction of Engg.-in-Charge. a) 2 x 2.5mm2 for inverter wiring |
| 161 | b) 2 x 1.5mm2 + 1 x 1.5mm2 |
| 162 | c) 2 x 2.5mm2 + 1 x 1.5mm2 |
| 163 | d) 2 x 4mm 2 + 1 x 1.5mm2 |
| 164 | e) 4 x 6mm2 + 2 x 2.5mm2 |
| 165 | f) 4 x 10mm2 + 2 x 4 mm2 |
| 166 | MAIN PANELS/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens gray powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. In commer- 01 number of 100 Amps 4P MCCB,25KA with 100A 4P changeover switch (Icu=100%Ics) with shunt trip.with auxuliary Busbar- 04 numbers of 100Amps Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator Out going- .(i)63A FP MCCB 16KA- 07 Nos. (ii) 63A 4P MCB-03 Nos. (iii) 40A 2P MCB- 03 Nos.Instrument- (i) 06 (03 main +03 DG) numbers phase indicating lamp with HRC fuse.(ii) 01 set of digital type multifunction meter with CT for voltage, current, frequency, PF, THD indication (iii) 01 set of 40KA TYPE2+1 4P SPD along with 63A 4P MCB.Make of switchgear-Legrand/Schneider/ Siemens/ ABB/ Havells/ C&S/ Hagar/L&T |
| 167 | DBsSupplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FRLSHPVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(but with out MCB/ RCCB/ Isolator)(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD) |
| 168 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND/ Siemens/ Schneider /Equievalant model of Havells/C& S/ ABB/Hagar/L&T in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. |
| 169 | Supplying and fixing 6-32Amps DP 240 volts, MCB Make-LEGRAND/ Siemens/ Schneider /Equievalant model of Havells/C& S/ ABB/Hagar/L&T in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. |
| 170 | Supplying and fixing 40Amps 4P 415 volts MCB Make-LEGRAND/ Siemens/ Schneider /Equievalant model of Havells/C& S/ ABB/Hagar/L&T in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. |
| 171 | Supplying and fixing 40Amps 4P 415 volts RCCB 30 mA Make-LEGRAND/ Siemens/ Schneider /Equievalant model of Havells/C& S/ ABB/Hagar/L&T in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.Fitting & Fixtures |
| 172 | Fitting & FixturesS/F. of Superior type Call bell with push & flexible cord as per direction of Engg.-in-Charge. |
| 173 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge. |
| 174 | S/F of BLDC Fan regulator.Make:Legrand / L&T / Havells / Anchor / Eq as per direction of Engg.-in-Charge. |
| 175 | S/F. of 250mm Sweep Exhaust fans of ISI marked.(Make:-Havells Thrill Air DX / Usha / Crompton / Orient / Bajaj / Halonix/equivalent) as per direction of Engg.-in-Charge. |
| 176 | S/F. of 90Wt. With efficacy of 120lm/W Light emitting diode Street light fittings of Havells/ Crompton/ Bajaj/Philips/Halonix /Panasonic/ Wipro/LT as per direction of Engg.-in-Charge. |
| 177 | S/F. of 120Wt. With efficacy of 120lm/W Light emitting diode Street light fittings of Havells/ Crompton/ Bajaj/Philips/Halonix /Panasonic/ Wipro/LT |
| 178 | S/F. of 20Wt.,100lumens/watt efficacacy, aluminium batten Light emitting diode Tube light fittings of Havells/ Crompton/ Bajaj/Philips/ Halonix /Panasonic/Wipro/LT as per direction of Engg.-in-Charge. |
| 179 | S/F. of 18 Wt.Surface/Recess Mounting LED Down Light of Bajaj/ Havells / Crompton/ Philips/ Panasonic/Wipro/Halonix make as per direction of Engg.-in-Charge. |
| 180 | S/F. of 15 Wt.Surface/Recess Mounting LED Down Light of Bajaj/ Havells / Crompton/ Philips/Panasonic/Wipro/Halonix make as per direction of Engg.-in-Charge. |
| 181 | S/F. of 12 Wt.Surface/Recess Mounting LED Down Light of Bajaj / Havells / Crompton / Philips / Panasonic/ Wipro / Halonix make as per direction of Engg.-in-Charge. |
| 182 | S/F of 3 Modular Skirting LED light fitting.Make:Legrand / Bajaj / Havells / Crompton / Philips / Panasonic / Wipro / Halonix as per direction of Engg.-in-Charge. |
| 183 | Supplying and fixing of 3 Pin , 5A ceiling rose on the existing junction box / wooden block including connection etc. as required. |
| 184 | Lightning ProtectionSupply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/Cape as per direction of Engg.-in-Charge. |
| 185 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/Cape as per direction of Engg.-in-Charge. |
| 186 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/Cape as per direction of Engg.-in-Charge. |
| 187 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561 ( 2nos / expansion piece ).Make - OBO / Dehn / Cape as per direction of Engg.-in-Charge. |
| 188 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO / Dehn / Cape as per direction of Engg.-in-Charge. |
| 189 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/Cape as per direction of Engg.-in-Charge. |
| 190 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp testedupto 100KA lightning current . Make-OBO/Dehn/Cape as per direction of Engg.-in-Charge. |
| 191 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/Cape as per direction of Engg.-in-Charge. |
| 192 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO / Dehn / Cape as per direction of Engg.-in-Charge. |
| 193 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/Cape as per direction of Engg.-in-Charge. |
| 194 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/Cape as per direction of Engg.-in-Charge. |
| 195 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/Cape as per direction of Engg.-in-Charge. |
| 196 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO / Dehn / Cape as per direction of Engg.-in-Charge. |
| 197 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/Cape as per direction of Engg.-in-Charge. |
| 198 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO / Dehn / Cape as per direction of Engg.-in-Charge. |
| 199 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/Cape as per direction of Engg.-in-Charge. |
| 200 | Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO / Dehn / Cape as per direction of Engg.-in-Charge. |
| 201 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/Cape as per direction of Engg.-in-Charge. |
| 202 | Installation of the above arrangements including all accessories as per Direction of Engg. In charge. |
| 203 | CABLESProviding,fixing and laying of 50 mm dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching (75 mm depth) and refilling as per direction of Engg.-in-Charge. |
| 204 | Supply of 35 sq.mm 3 & 1/2 core XLPE Al.Armoured Cable of ISI marked.(Make -Polycab / Havells / KEI / RR Kable / Finolex / Gloster) as per direction of Engg.-in-Charge. |
| 205 | Laying and fixing of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required as per direction of Engg.-in-Charge. |
| 206 | Laying and fixing of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on surface as required as per direction of Engg.-in-Charge. |
| 207 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. (3.5C x 35 sq.mm) as per direction of Engg.-in-Charge. |
| 208 | S/F of special earthing complete with 3mtr long 40 m dia G.I pipe , 600x600x3.15mm thick copper plate , charcoal , salt including excavation of earth and filling of loose soil upto ground level including all connection and masonary work as per direction of Engg.-in-Charge. |
| 209 | Supplying and laying 25 mm x 5 mm CU earth strip ISI marked on surface or in recess for connection etc as required.as per direction of Engg.-in-Charge. |
| 210 | Supply and installation of Rubber Mats 8 mm thick as per direction of Engg.-in-Charge. |
| 211 | FIRE EXTINGUISHER Supplying installation testing and commissioning of ABC type fire extinguishers of 6 kg capacity confirming to IS:14609 & ABC powder confirming IS:13849 presurized with Nitrozen Gas marked.including cost of all material & labour for all floors & service building etc. all complete. Make-KANEX/FIRE SHILD /SAFEX or equivalent |
| 212 | Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket for all floors & service building etc. as per direction of Engineer-in-charge.Make-KANEX/FIRE SHILD /SAFEX or equivalentor equivalent |
| 213 | Supplying, installation, testing and commissioning of Mechanical Foam type 9 litre capacity Fire Extinguisher, ISI marked, IS: 10204, containing 540 ml AFFF liquid ISI marked, IS: 4989 Part II and a polyurethane coated CO2 Gas Cartridge, ISI marked, IS: 4947 complete with gunmetal union cap, nylon hose with plastic foam making branch and wall mounting bracket as per direction of Engineer-in-charge. |
| 214 | MISCELLANEOUS WORKSand Buket as per IS Specicification |
| 215 | Buket Stand to Store 10 nos of Buket also having Aluminium sheet above the to prevent the stand from rain/sunst. |
| 216 | BorewellLabour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the holde hammer drilling righs or combination drilling rigs ( 1200cfm/300 pxl) as required to suit the site condition as per the direction of E.I.C including use of own rigs with its accessories and plant and consumable etc. for lowering of 200mm dia PVC pipes for housing fitted with socket and with or without well screen as per technically for soft, medium , hard and boulder formation (PVC casing pipes if required to prevent collapse overburden is to be provided by the contracor including lowering and with drawing after completion of the tubewell ( including both labour for drilling 200 mm dia up to 30 Mtr. and labour for drilling 150 mm dia form 30 Mtr. to 150 Mtr. Depth. |
| 217 | 10000560Cost of PVC (ASTM Schedule-80) Pipe 200 mm dia (ASTM D-1785) Make Oriplast/ Supreme/ Finolex ( ASTM SCH-80 200 mm dia Pipe. |
| 218 | 10000564Lowering 200 mm dia. PVC pipes with or without slotted pipes as per the necessity from ground level with fitting and fixing the same in a perfectly vertical positon. This includes cutting, threading pipes/ slotted pipes with providing and fixing of required jointing materials, tools and plant etc. complete and keeping the top of the casing pipe threaded including plugging tube wells so as to prevent entry of foreign materials from above. ( For Hammer Drilling Rig/ Combination Drilling Rig ) |
| 219 | 10000570Cleaning and developing 200 mm dia. Tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour ( For Hammer drilling Rig/ combination Drilling Rig )Ground Floor |
| 220 | 10000583Supplying and fixing of control panel board with all accessories ( Up to 3 HP Single phase ) Make- KSB |
| 221 | 10000588Supplying and fixing of HDPE Pipes 32/40 ( High Density Polyethylene Pipes having inner dia. 32mm and outer dia. 40 mm) 6 Kg. / Sq. Cm with IS specification ( 32mm Nominal Bore Size) Make Finolex/ Oriplast / Supreme |
| 222 | 10000594Supplying and fixing of PVC coated steel rope including cost of material, labour, etc. complete. Make _ Mahadev/ Aerolex |
| 223 | 10000596Supplying and fixing of Finolex/ L&T/Cable 4 Sq.mm (3 core copper wire flat cable with PVC insulation) |
| 224 | 100005600Supplying and fixing of acceessories like Nipple, Bore cover, MS Champ, Nut Bolt, Stainless Steel nipple, Short piece, GI bend, Socket, etc. complete |
| 225 | 10000602Installation charges pump set with all accessories including transportation etc. |
| 226 | 10001192Supplying submersible Pump set with the cost Motor of following model including cost of transportation charges, 1.5 HP, Single Phase, 32D, 21 Stage ( Head 33-167M) Make KSB (2C/25) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy