| 1 | Demolition of brick work built in cement mortor including all quoins,arches,pillars etc complete all as specified and directed. |
| 2 | Taking up or down existing 15mm bore steel water tubing and connections,including clreaning for refixing or removal, fixed/laid in any situation, complete all as specified and directed. |
| 3 | Taking up or down existing 20mm bore steel water tubing and connections,including clreaning for refixing or removal, fixed/laid in any situation, complete all as specified and directed. |
| 4 | Dismantling brick tiles or terracing tiles, single layer on roofs jointed and pointed in cement mortar including removal of grass vegitation including roots near out let of RWP and OHT staging area or specifically ordered in writing complete all as specified and directed. |
| 5 | Demolition of mud phuska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part hereof ) and removing from site to adistance exceeding 250m but not exceeding 500m complete all as specified. Note :- Demolition of Mud puska to be cut in average thickness from top surface of roof for creating the slope as directed |
| 6 | Demoletion and breaking up drain pipes 110 mm dia (Salt glazed ware,AC, PVC or reinforced concrete) set in cement mortar complete all as specified and directed |
| 7 | Taking down cement plaster of any description on brick walls or concrete or stone and ceilings including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 8 | Removing & refixing of existing water tank of capacity exc 200 ltr and n exc 500 ltr, setting aside (or lowering if required) for repair, cleaning etc and hoisting, reconnecting & refixing in position complete all as specified and as directed. |
| 9 | Removing & refixing of existing water tank of capacity exc 500 ltr and n exc 1000 ltr, setting aside (or lowering if required) for repair, cleaning etc and hoisting, reconnecting & refixing in position complete all as specified and as directed. |
| 10 | M&L for brick work built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 11 | M&L for brick work (EXCEPT BRICKS) built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 12 | M&L for Plain Cement Concrete (1:3:6) type C-1 using 20 mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 13 | M&L for 50mm thick Plain Cement Concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in roof padding and all other similar works complete all as specified and directed. |
| 14 | M&L for 10 mm thick screed bed or bedding layer in cement mortar (1:4) with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed. |
| 15 | M&L for 15mm thick rendering cement plaster in cement mortar (1:4) on external fair faces of brick/concrete surfaces with water proofing compound as per manufacturer instructions , finished even and smooth without using extra cement complete all as specified and directed. |
| 16 | M&L for 15mm thick rendering cement plaster in cement mortar (1:4) on external fair faces of brick/concrete surfaces with water proofing compound as per manufacturer instructions , finished even and smooth with using extra cement complete all as specified and directed. |
| 17 | M&L for 5 mm thick rendering cement plaster in cement mortar (1:3) in ceiling on fair faces of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 18 | M&L for raking out joints and flush pointing in cement mortar (1:3) to brick work or brick tiles,laid flat, in floors,surface channels, roofs etc complete all as specified and as directed |
| 19 | Supply only Integral water proofing compound complete all as specified and directed. |
| 20 | M&L for applying one coat of cold applied polymeric modified bituminous primer @ 0.30 kg per sqm including preparation of roof surfaces complete all as specified and as directed. |
| 21 | M&L for One layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surfaceby forced application complete all as specified. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing.Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer's instructions.(ii) A minimum overlap shall be 75mm length wise and 100 mm width wise of polymeric membranes respectively and sealed all overlaps and joints as manufacturer's instructions. |
| 22 | M&L for preparation of surfaces of platered, brick, concrete, polymeric etc, of any description, over10cm in width or girth,not otherwise describedone and applying two coats of Solar Reflective Bituminous Aluminium paint @0.1 Kg/ Sqm over APP Membrane complete all as specified and directed. |
| 23 | M&L for 40mm thick brick tiles laid on mud mortar or mud phuska and joints grouted flush and pointed flush as the work proceeds in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed. |
| 24 | M&L for 40mm thick brick tiles (EXCEPT TILES) laid on mud mortar or mud phuska and joints grouted flush and pointed flush as the work proceeds in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed. Note:- Old seviceable tiles shall be re-used retrieved after dismantling brick tiles on roofs/terrace. |
| 25 | M&L for applying bond coat of epoxy bonding agent & cement in 1:1 ratio for bonding old and new concrete on damaged surfaces applying polymer modified mortar in cement mortar 1:3 including mixing of polymer latex additives 60 mm average thickness (Chajja, fins,borders etc) complete all as specified and as directed.Notes :- (i) Quantity of polymer to be used @ 15 % by weight of cement(ii) Use the electrical mixer to get homogeneous dough on bond coat surfaces.(iii) To achieve required thickness repeat this step after 24 Hrs to as required.(iv) Keep the surfaces moist using water fog for 5 to 7 days.(v) Rate shall be inclusive of all necessary scaffolding for building hieght upto 24 mtr. |
| 26 | M&L for preparing new plastered surfaces of ceiling and applying three coats of lime white wash complete all as specified and directed. |
| 27 | S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floor complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 28 | S&F 110mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 29 | S&F 15 mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete to walls and celling or laid in floor, complete all as specified and directed. |
| 30 | S&F 20 mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete to walls and celling or laid in floor, complete all as specified and directed. |
| 31 | S&F in repair 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and directed. |
| 32 | S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and directed. |
| 33 | S&F in replacement 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), three layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule hoisted and fixed including dismentling and taking down old unserviceable water tank capacity 500 litres complete as specified in SSR Part-I. complete all as specified and directed. |
| 34 | S&F in replacement 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), three layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule hoisted and fixed including dismentling and taking down old unserviceable water tank capacity 1000 litres complete as specified in SSR Part-I. complete all as specified and directed. |
| 35 | S&F in repair 15 mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic float ball screwed for iron pipe complete all as specified and directed. |
| 36 | S&F in repair 20 mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic float ball screwed for iron pipe complete all as specified and directed. Please Enable Macros to View BoQ information |