| 1 | Demolition of brick work or stone masonry, built in CM including all quoins, arches, pillars etc. but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and directed. |
| 2 | Brick work with sub class B (old size) brick straight or curved on plan exc 6 m mean radius in CM 1:4 complete all as specified and directed. |
| 3 | All as per Ser item no 2 above but except bricks complete all as specified and directed. |
| 4 | Cleaning /clearing of sewage line (Including manhole except 1st manhole) 100mm to 350mm bore of any description under ground any depth, removing any type of blockage including desilting and de-chocking from drain with combined high pressure water jetting cum suction (vacuum) type machine mounted on LMV/HMV having facility of high pressure vacuum including provision of hydraulic application through high pressure thermoplastic fiber based water jetting hose and through conical round shaped nozzle pipe and flushing after cleaning including clearing of manhole, sludge water shall be disposed of directed including taking of manhole cover and re-fixing the same after cleaniing complete all as specified and directed. |
| 5 | Dewatering/Desludging & cleaning of manhole of any depth, any size, taking out water mixed with sludge and solid sludge including any foreign materials such as stones, tree hedges etc, removing and depositing sludge at a distance not less than 20 meter in a ditch including necessary excavation of pits and covering with earth & spraying unslaked lime on the covered ditch as well as around the manholes to make hygienic including necessary flushing of manholes with water after desludging complete all as specified and directed. |
| 6 | Taking out/Pumping out contaminated sewage water from septic tank/soakage well including inlet/outlet chamber after plugging incoming sewage line through combined high pressure water jetting cum suction (vaccum) type machine mounted on HCV Honey succer vehicle of capacity not less than 6000 ltrs each and facility of high pressure vaccum and removing off the same in the pit to a placet complete all as specified and directed.Note: (i) One lorry unit will be considered for full load of 6000ltrs irrespective of taking out.(ii) The details of HCV Honey succer vehicle eg. registration number, owner name & driver name will be maintain in register to be kept on charge of JE and the number of trips each day made by the vehicle will be entered in register duly signed by contractor, JE & Engr-in-Charge. This register will be checked by JE (QS&C) during the tech check of RAR/Final bill. |
| 7 | Desludging the solid sludge from septic tank, soakage well including inlet/outlet chamber, removing out all scum, silt reduce sludge (both organic/inorganic nature) after plugging the incoming sewage line through combined high pressure water jetting cum suction (vacuum) type machine mounted on LMV/HMV and facility of high pressure vacuum and removing and dumping off the same in the tank to a place out side cantonment at the place marked for the purpose by local municipality or area controlling authority complete all as specified and directed.Note: (i) One lorry unit will be considered for full load of 6000ltrs irrespective of taking out.(ii) The details of HCV Honey succer vehicle eg. registration number, owner name & driver name will be maintain in register to be kept on charge of JE and the number of trips each day made by the vehicle will be entered in register duly signed by contractor, JE & Engr-in-Charge. This register will be checked by JE (QS&C) during the tech check of RAR/Final bill. |
| 8 | Cleaning of soil waste pipe (cast iron/PVC/SGSW/DWCP )150/200mm bore laid in ground any slope or gradient and depth 3 mtr by roding taking out all residue from the lines/manholes including water and depositing at a distance not less than 20 mtr in ditch finally covering the ditch with earth and spraying unslacked lime on the covered ditch as well as around the manholes to make hygienic including excavation of ditch testing of line by flushing water after cleaning etc complete all as specified and directed. |
| 9 | Cleaning/clearing of IWC/ EWC, gully trap /floor trap including CI pipe / PVC pipe upto first manhole by roding, taking out all residue including waste and testing by pouring water after cleaning etc complete all as specified and directed by Engr-in-Charge. (Note: Cleaning of PVC/CI pipe from first floor / ground floor embedded in floor or fixed to wall included in this item) complete all as specified and directed. |
| 10 | Cast iron oval access covers / inspection cover with bolts rubber gasket to make it water tight for 75mm/100mm bore CI fittings including taking out broken/ unserviceable cover with bolts etc and removing from site complete all as specified and directed. |
| 11 | Excavation in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5m wide for foundation etc or for shaft, wells, cesspits, manhole, pair house etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth and getting out in any type of soil complete all as specified and directed. |
| 12 | Returning filling in including, spreading, leveling watering and well ramming in layer not exceeding 25cm in each layer complete all as specified and directed. |
| 13 | Removing excavated material not exceeding 50 M and depositing where directed at level not exceeding 1.5m above the starting pointing complete all as specified and directed. |
| 14 | M & L for Plain cement concrete 1:4:8 as in foundation type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling or mass concrete complete all as specified and directed. |
| 15 | M & L for Plain cement concrete 1:2:4 type B-1( using 20mm graded crushed stone aggregate) as in benching, coping including watering slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 16 | M & L for TMT mild steel bars 10MM dia and over cut to length bent to shape required including cranking bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire annealed 0.9 mm dia or securing with clips complete all as specified and directed. |
| 17 | M & L for Mild Steel TMT bars 6 to 8 mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed. |
| 18 | M & L for RCC 1:1.5:3 for septic tanks slabs complete all as specified and directed. |
| 19 | M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick complete all as specified and directed. |
| 20 | M & L for Precast cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in manhole/drain slab cover all as specified and set in CM 1:4 complete all as specified and directed. |
| 21 | Rendering 15mm thick cement plaster in CM 1:4 on faces of brick work with or concrete WPC finished even and smooth without using extra cement complete all as specified and directed. (Note: WPC shall be measured and paid separately. ) |
| 22 | Demolition and breaking up 150mm dia drain pipes (Salt glazed ware, AC or reinforced concrete ) and set in cement mortar complete all as specified and directed. |
| 23 | Demolition and breaking up 200 mm dia drain pipes (Salt glazed ware, AC or reinforced concrete ) and set in cement mortar complete all as specified and directed. |
| 24 | Concrete bed to drain pipes laid in trenches including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate for 150mm bore pipe, complete all as specified and directed. |
| 25 | Concrete bed to drain pipes laid in trenches including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate for 200mm bore pipe, complete all as specified and directed. |
| 26 | M & L for Salt -Glazed stoneware drain pipes 150 mm dia laind in trenches and jointed complete all as specified and directed. |
| 27 | M&L for 200mm bore dia reinforced cement concrete pipes, class NP-2, laid and jointed complete with collars, complete all as specified and directed. |
| 28 | M & L for 200mm Bore / inner dia double wall, corrugated HDPE Pipe (SNB) (ISI Marked) with integral socket & necessary fitting jointing as directed & laid in trenches complete all as specified and directed |
| 29 | M & L for 150mm Bore / inner dia double wall, corrugated HDPE Pipe (SNB) (ISI Marked) with integral socket & necessary fitting jointing as directed & laid in trenches complete all as specified and directed |
| 30 | Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 150mm dia of pipe complete all as specified and directed. |
| 31 | Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 225mm dia of pipe complete all as specified and directed. |
| 32 | M & L 75mm thick PCC 1:3:6 Type B2 ( 40 mm graded crushed stone aggregate) as in sub base, hardstanding and pavings etc complete all as specified and directed. |
| 33 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 34 | M & L for Glazed ceramic colored tiles 600mmx300mmx 6 to 7mm thick/450mm x300 mm x 7mm, as in patches in vertical surfaces such as dado, skirting, wall etc set & jointed in neat cement slurry and pointed with coloured cement to match with tiles in over and including 10mm thick cement plaster in cement mortar 1:4. complete all as specified and directed. |
| 35 | S&F Non-skid ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.11sqm but n exc 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or beddding layer of CM 1:6 including complete all as specified and directed. |
| 36 | M & L for 100mm dia Cast iron pipes with flanged ends, centrifugally cast, class A, in any length laid in trenches complete all as specified and directed. |
| 37 | M & L for 80mm dia Cast iron pipes with flanged ends, centrifugally cast, class A, in any length laid in trenches complete all as specified and directed. |
| 38 | M & L for upto 150mm bore Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed. |
| 39 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 110mm bore complete all as specified and directed. |
| 40 | S&F PVC (SWR) Branch Piece double equal or unequal of 110mm bore complete all as specified and directed. |
| 41 | S&F PVC (SWR) Branch Piece double equal or unequal of 75 mm bore complete all as specified and directed. |
| 42 | S&F in repair stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays incl bolt and nuts securing ends of stays to wall or roof of 75mm bore complete all as specified and directed. |
| 43 | S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 44 | Provided M & L for cleaning of all types of blockage of Nahni traps/floor traps/bottle traps, blockages of WC's, rain water pipes and similar works complete all as specified and directed.Note :- 1. Labour shall be provided by the contractor on daily basis from 9:00 AM to 5:00 PM incl all Tools and Plants. Each labour shall intertain complaints everyday in working hours.2. The supervisor of Contactor shall take all complaints from the Complaint Cell and attend to all on the same day.3. Futher more, the feedback shall be given by the contractor/supervisor to concened JE from all aspect.4. Details of all the compliants attended shall be maintained in a register by contractor which will be signed by JE, Engr-in-Charge and contractor and the same will be produced alongwith RAR/FB. |
| 45 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion from cement concrete and making good disturbed ground complete all as specified and directed. |
| 46 | Excavation for post holes in any type of soil (or in similar hole ) each n.exc 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm including dismantling PCC including disposal of surplus n.exc 50m complete all as specified and directed. |
| 47 | M&L for PCC 1:3:6 type C-2 (40mm graded crushed stone aggregate) in foundation filling and mass concrete complete all as specified and directed. |
| 48 | M&L for posts and struts in fencing of angle, tee including cutting tops to shape as directed, drilling holes, notching for wire, Y angles wall for fencing, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified and directed. |
| 49 | Fixing chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed. |
| 50 | Supply only PVC coated MS Chain link fencing with line wires,any type and mesh size and any type of standards and dia of wire ( as directed by Engineer-in-charge) fixed with rails, staining bolts etc including provision of binding wire including dismantling existing unserviceable fencing complete all as specified and directed.(Note: rails, staining bolts will be measured in seperate Item) |
| 51 | Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and 5 to 10mm dia of shank complete all as specified and directed. |
| 52 | Preparation new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed. |
| 53 | Dismantling of barbed wire fencing of any description and any positions complete all as specified and directed. |
| 54 | Demolition of cement concrete (Reinforced) of any description and any position not other wise specifically provided reinforcement cut as required to facilitate demoltion complete all as specified and directed. |
| 55 | Demolition of cement concrete in ground floor and paving n.exc 15cm thickness (below & above GL) unreinforced complete all as specified and directed. |
| 56 | S&F Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and directed. |
| 57 | Fixing only galvanised 2 strand, steel barbed wire of any description (obtained from dismantling) and straining and fixing to any type of standard rails straining bolts, including aluminium paint and securing or tying at crossing with and provn of galvanised MS wire complete all as specified and directed. |
| 58 | Fixing, Restraining, resecuring incl making good staples etc of existing barbed wire fencing complete all as specified and directed. |
| 59 | S&F in Repair Punched Tape Concertina Coil (including spike and handle) with 56 loops and dia 600mm, Max covered length 10 RM, having a core wire of high carbon spring steel of high tensile strength conforming to IS 4454/Part-I/Grade-SM, duly hot dipped galvanized with heavy zinc coating with minimum 230 gms per Sqm. The punched tape and core wire (2.5 + 0.35mm dia) shall be heavy galvanized (IS-1730) (Wire-275GSM & strip-200 GSM) conforming to IS-513 to provide protection against outdoor exposure. The punched tape shall mechanically crimped over the core wire and then formed into a coil at various parts of the periphery of the coil. The width of strip as 19mm and spacing of blades 24.00 + 0.5 mm C/C. The weight of each coil shall be 8.50 + 5% Kgs without packing material and coil length 10 Mtr (maximum) when opened up, (Each coil should packed with bituminized hessian cloth for providing protective packing) as in fencing including fixing with special galvanised fasteners such as J clips, C clips, U clips fixed at any height on compound wall including dismantling old concertina coil wire including necessary scaffolding as required complete all as specified and directed.[Note: After stretching the coil the length of the compound wall on which it has been stretched shall be measured as straight length for payment] |
| 60 | Preparation of old decorated plastered or unplastered surface including cleaning by brooming down with steel wire brushing, scraping down smoke soot, moulded, moss, efflorscent salt, trading oil and greasy spots and applying one coat of cement base paint on walls of external surfaces complete all as specified and directed.Note: The painting is to be done using smart painting tools and technique as mentioned in Particular specification. Tenderer shall take this aspect in consideration before quoting his rates and no claim on account of misunderstanding or any thing else shall be admissible/acceptable at any later stage. |
| 61 | All as per ser item no 60 above here-in-before but applying two coat of cement base paint on walls of external surfaces complete all as specified and directed.Note: The painting is to be done using smart painting tools and technique as mentioned in Particular specification. Tenderer shall take this aspect in consideration before quoting his rates and no claim on account of misunderstanding or any thing else shall be admissible/acceptable at any later stage. |
| 62 | M&L for providing precast cement concrete (type B0 1:2:4 12.5mm graded aggregate) louvres and jallies, 25mm thick (measured solid), including all mouldings and form work including demlation of old louvres and jallies complete all as specified and directed. |
| 63 | M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 64 | M&L for 75 mm thick PCC1:4:8 type D-2 using 40mm graded as in sub base of floor, hard standing (40 mm graded crushed stone aggregate), to received tiles including necessary form work etc complete all as specified and directed. |
| 65 | M&L in repair 60mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-35 Gde of approved shape, size and colour conferming to IS 15658-2006 and laid over and including 25mm thick grid cushion complete all as specified and directed. |
| 66 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.50 sqm each and removing from site complete all as specified and directed. |
| 67 | S&F Factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube with wooden grain printed PVC sheet used inserted of plain colour PVC sheet & edges will be painted to match with printed sheet complete all as specified and directed. |
| 68 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified and directed. |
| 69 | S&F 100 mm long mild steel butt hinges, cold rolled, medium weight complete all as specified and directed. |
| 70 | S&F for 125mm long anodised aluminium barrel tower bolt of extruded section complete all as specified and directed. |
| 71 | S&F 150mm long anodised aluminium handles, cast type complete all as specified and directed. |
| 72 | 300mm long aluminium alloy, anodized sliding door bolt with hasp stapple ( bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed. |
| 73 | Excavation in trenches not exceeding 1.5M width and not exceeding 1.5M depth and getting out for laying of pipe etc in soft/loose soil complete all as specified and directed. |
| 74 | Supply & Laying in trenches galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, flanges, gaskets, nipples, short pieces etc as required at site for the following sizes including dismantling and taking out old unserviceable pipe line alongwith fittings from existing connections complete all as specified and directed.Note :- (i) Excavation and earth work shall be measured and paid seperately under relevant item of Sch A (ii) The rates quoted inclusive of cutting, jointing with flange/welding and testing of the pipe all as specified and directed. |
| 75 | Bore of tube 150 mm dia. |
| 76 | Bore of tube 100 mm dia. |
| 77 | Bore of tube 80 mm dia. |
| 78 | Bore of tube 50 mm dia. |
| 79 | Bore of tube 40mm dia. |
| 80 | Bore of tube 25mm dia. |
| 81 | Bore of tube 20mm dia. |
| 82 | Bore of tube 15mm dia. |
| 83 | Supply and laying in replacement of spigot and socket ductile iron water tubing 150 mm,class K-9, cement mortar lining on inner surface and one coat of bituminous paint over exposed surface ISI marked, IS No. 8329: 2000, including rubber joint of suitable size laid on roof/floor/trenches with proper alignment as per site requirement and carryout testing against leakage before filling the trenches etc complete all as specified and directed. |
| 84 | M & L in repairs for CI or DI specials conforming to IS - 1538 or 9523, spigot /socket or flanged fitting I.e. bend, tee, collar, flanged/ socket /spigot, Tappers, flanges and tail pieces etc suitable for 100/150/200 mm bore CI/DI pipes (joints and joining material shall be measured and paid seperately) complete all as specified and directed. |
| 85 | Supply & Fixing galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, nipples, flanges, gaskets, short pieces etc and fixed complete to walls and ceilings or laid in floors including dismantling existing steel tubing and connections fixed at any location complete all as specified and directed for the following sizes:- Note:- (i) The rates quoted inclusive of cutting, jointing and testing of the pipe. |
| 86 | Bore of tube 40mm dia. |
| 87 | Bore of tube 25mm dia. |
| 88 | Bore of tube 20mm dia. |
| 89 | Bore of tube 15mm dia. |
| 90 | S&F gun metal gate valves with iron wheel head screwed at both ends for iron pipes complete including dismantling of old unserviceable gate valve fixed at any location complete all as specified and directed for the all as directed for the following sizes:- |
| 91 | 50 mm dia. |
| 92 | 40 mm dia. |
| 93 | 25 mm dia. |
| 94 | 20 mm dia. |
| 95 | S&F stop valves of cast copper alloy screwed down high pressure with crutch or butterfly handles screwed both ends for iron pipe or for unions and fixed complete all as specified and directed for the following sizes:- |
| 96 | Bore dia of pipe 25mm. |
| 97 | Bore dia of pipe 20mm. |
| 98 | Bore dia of pipe 15mm. |
| 99 | Supply and fix cast iron sluice valve PN-1.6 conforming to IS 14846/2000, ISI Mark with MS spindle and iron wheel head with both ends flanged with new rubber gasket, bolts and nuts including dismantling of old unserviceable sluice valve fixed at any location complete all as specified and directed for the following sizes:- |
| 100 | 150mm dia. |
| 101 | 100mm dia. |
| 102 | 80mm dia. |
| 103 | Material & Labour for CI non return valve (NRV) conforming to IS 5312, ISI marked with GM flap of size 100 mm and connected with necessary bolts, nuts & washers, gaskets etc complete including dismantling of old unserviceable non return valve complete all as specified and directed. |
| 104 | Material & Labour for CI non return valve (NRV) conforming to IS 5312, ISI marked with GM flap of size 150 mm and connected with necessary bolts, nuts & washers, gaskets etc complete including dismantling of old unserviceable non return valve all complete all as specified and directed. |
| 105 | Construction of valve chambers with 150 mm thick PCCfoundation 1:4:8 type D2 using 40 mm graded trap stone aggregate, 230 mm thick brick masonary wall with sub class 'B' bricks builts in cement mortar 1:4 10 mm thick plastering to brick masonary in cement mortar internally and externally upto 15 cm below ground level, 50 mm thick coping with PCC 1:2:4 type B1 using 20 mm graded crushed trap stone aggregate valve chamber frame cover made of mild steel angles of size 40mm x 40mm x 6mm and cover made of 2.5 mm thick mild steel sheet fixed with mild steel hinges - 02 Nos, locking arrangements with provision of locks and painting the steel surfaces with two coats of synthetic enameled paint over a coat of zinc chromate primer including neccessary earth work, excavation, dismantling of existing valve chmber of any size and pattern and at any position complete all as specified and directed for the following:- |
| 106 | 1000CM x 1000CM X 1000CM (Internal Size) |
| 107 | 900CM x 900CM X 900CM (Internal Size) |
| 108 | Servicing , painting and greasing & minor repairs of sluice valves of different sizes at any location including replacement of glands complete all as specified and directed. Please Enable Macros to View BoQ information |