| 1 | Taking down cement plaster including racking out joints, hacking for key & scrubbing down with water etc as specified and directed by Engineer - in - Charge. |
| 2 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises as specified and directed by Engineer - in - Charge |
| 3 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons Laid, bedded and pointed in any mortar etc as specified and directed by Engineer - in - Charge. |
| 4 | Demolition of Concrete is ground floors and pavings n exc 15 cm thickness (below or above ground level) as specified and directed by Engineer-in-Charge. |
| 5 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed by Engineer-in-Charge. |
| 6 | Demolition of Reinforcement cement concrete of any description and in any position not otherwise specifically provided for, as specified and directed by Engineer - in - Charge |
| 7 | M&L for cement concrete type D2,1:4:8 (using 40 mm graded stone aggregate) as in mass concrete complete all as specified and directed |
| 8 | Taking down chowkats or frames not exceeding 1.5 Sqm each with shutter (without taking off shutter from the frame) removing from site complete all as specified and directed by Engineer-in-Charge. |
| 9 | Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking off shutter from the frame) removing from site complete all as specified and directed by Engineer-in-Charge. |
| 10 | Taking down shutter including frame of cupboard of any description exc. 1 sqm but n.exc 2 sqm each and removing from site complete all as specified and directed by Engineer-in-Charge. |
| 11 | Taking up or down 15 mm steel tubing and connections including cleaning for refixing or removal complete all as specified and directed by Engr-in-Charge |
| 12 | Taking up or down 20 mm steel tubing and connections including cleaning for refixing or removal complete all as specified and directed by Engr-in-Charge |
| 13 | Dismantling water tanks 500 & n exc 1000 and removing to store of all retrieved material |
| 14 | Dismantling timber scantlings 40 Sqcm and over in section, in any position , framed work complete all as specified and directed. |
| 15 | Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings complete all as specified and directed. |
| 16 | M & L for Steel work in tubular hollow rectangular trusses, purlins, rail including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade inluding one coat of zinc chromate primer before fabrication distance pieces, cleats etc GDE Fe 410-S. complete all as specified and directed. |
| 17 | S & F Pre-painted galvalume aluminium zinc coating GI based semi corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 18 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 19 | M&L for Providing & fixing false ceiling at all heights with GRG (Glass FibreReinforced Gypsum) false ceiling tiles of Size 595mm x 595 mm of approved texture,design and patterns having moisture content less than 2%, humidity resistanceof 99%, NRC0.50 to 0.75 as per IS8225:1987, Noncombustible as per BS 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15mm x 32 mm of length 3000mm,cross-T of size 15mmx 32mm of length 1200mm and secondary intermediate cross-T of size 15mm x 32 mm of length 600mm to form grid module of size 600mmx 600mm ,suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1OOOmm length and Lshape level adjuster of size 85mmx25mmx2mm. Galvanised iron perimeter wall angle of size 24mmx 24mmx0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-inCharge. including dismantling of old false ceiling complete all as specified. |
| 20 | M&L for vrtrified Ceramic tiles light shade (8 to10) mm thick (square) polished, area of each tiles not exceeding 0.36 sqm( 600mm x 600mm ) in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement over and including screeding M&L for 15mm thick in CM 1:6, complete all as specified and directed |
| 21 | All as per item no 20 but on verticle surfaces over and including M&L for 10 mm thick plaster in CM 1:4 all as specified and directed. |
| 22 | M&L for glazed coloured ceramic tiles 300mm x 600mm x 7mm thick in vertical wall complete or in patches surfaces set and jointed in neat cement slurry and pointed in white cement using pigment to match the shade of tiles over and inclding plastering M&L for 10mm thick in CM 1:4, complete all as specified and directed. |
| 23 | M&L Non- skid coloured ceramic tiles 7mm to 8mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tile laying over and including M&L for 15 mm thick cement mortar 1:6 including dismantling of floor tiles and hearting complete all as specified and directed. |
| 24 | M&L 18mm-20 mm thick Granite of any colour (table rubbed and polished) as in windows cill & cooking platforms and like in cement mortar (1:4) including form work , pointing in white cment (1:2) using marble dust with admixture of pigment to match with shade of granite with full round bull nosing edging complete all as spd as directed |
| 25 | M & L for 75mm thick PCC 1:3:6 , type C-2 using 40 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 3 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed . |
| 26 | M&L for reinforced cement concrete 1:1.5:3 type A-1 (using 20mm graded stone aggregate) (nominal mix) as in slabs supported on wall,landing, balconies, shelves and like including bonding agent , complete all as specified (reinforcement to be measured & paid under respective items). |
| 27 | M&L for reinforced cement concrete 1:1.5:3 type A-1 (using 20mm graded stone aggregate) (nominal mix) as in Lintel/Roof beam and chajja including bonding agent , complete all as specified (reinforcement to be measured & paid under respective items). |
| 28 | S&F Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) completed all as specified and directed. |
| 29 | S&F Form work to sides and soffits of floor or roof beam, beam hings, girders bressume, lintles, contilevers, shelves,Chajjas including support over lungs etc also splays between floor and beams etc. completed all as specified and directed. |
| 30 | M&L form work to edges of concrete flats, treads, breaks in floors window cill, concrete railing opening in conc wall , floor and roof n.exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n.exc 20cm wide for rough finished surfaces of concrete, complete all as specified. |
| 31 | Supply and fix TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) but not less than 0.9 mm dia conforming to Fe-410 - 0, complete all as specified. |
| 32 | S&F Mild steel TMT bars 5mm dia and over upto and including 10 mm dia in stirrups,spaces and binders and all as specified and directed. |
| 33 | M&L for brick work with fly ash bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as spd as directed |
| 34 | M&L rendering 15 mm thick in CM 1:6 on brick masonary wall surfaces or on other than fair faces of brick masonry finished even and smooth witout using extra cement complete all as specified and directed. |
| 35 | M&L 15mm thick rendering in cement mortar 1:4 to on brick masonary wall surfaces or on other than fair faces of brick masonary fair finished without using extra cement with using water proofing liquid complete all as specified and directed |
| 36 | S&F for 105mmx60 mmx 1.25mm thick pressed steel, frames for door with one or more rebates including filing and inner surface of the frame shall be treated with a coat of bituminous paint & compaction with PCC 1:3:6 Type C1 necessary fixing lugs, SS hinges,lock strike plate, 02 x MS bar/flat at bottom of the frame etc, including wooden texture finished paint on the frame surface complete all as spd and directed. |
| 37 | S&F for 125mmx60mmx1.25mm thick pressed steel, frames for door with one or more rebates including filing and inner surface of the frame shall be treated with a coat of bituminous paint & compaction with PCC 1:3:6 Type C1, necessary fixing lugs, SS hinges, lock strike plate, 02 x MS bar/flat at bottom of the frame etc, complete including wooden texture finished paint on the frame surface all as specified and directed. |
| 38 | S&F for 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed . |
| 39 | S&F 35mm thick factory Glazed and skeleton shutters, open rebated of saal wood second class hard wood rail and stles and prepared to receive glass, gauze, etc. (without sash bars), divided into squared, with plain, cham-fered or rounded, mitred and rebated sash bars, any numbers sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats complete all as specified and directed by Engineer-in-Charge.(Note :- S & F Glass/gauge shall be measured and paid for separately) |
| 40 | S&F stainless steel wire cloth, 0.56 mm nominal dia of wire and average with of aperture 1.18 mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge. |
| 41 | S & F 140 mm long floor door stopper of aluminium alloy body and tongue, brass body and tongue with hard drawn steel spring as specified and directed by Engineer-in-Charge. |
| 42 | S & F Solid Prelam PVC Door Frame of size 50mm x 47mm made out of 5mm thick single side prelam PVC sheet used instead of Plain colour PVC sheet , suppling & fixing in opening as per specification & drawing |
| 43 | S&F 30 mm thick factory made one side Prelam PVC sheet other side decorative (door shutter) used instead of Plain colour PVC sheet. Stile and rails feathered at edges consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C' channel heaving a Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 44 | S&F mild steel window grills box type framed work as in window guard bars, grills or forged into spikes, framed balusters, walkway railing and similar work including welding complete FE-290 grade E-165 all as specified and directed. Please Enable Macros to View BoQ information |
| 45 | S&F mild steel window grills box type framed work as in window guard bars, grills or forged into spikes, framed balusters, walkway railing and similar work including welding complete FE-290 grade E-165 all as specified and directed. Please Enable Macros to View BoQ information |