| 1 | दर अनुबंध पर महिला व शिशु चिकित्सालय के अंर्तगत सिविल संबंधित मरम्मत कार्य। |
| 2 | Providing and fixing 1st quality standard white, grey, ivory,fume red brown, light green, light blue and other light shadesglazed tiles confirming to code IS : 15622 of size 200mm x300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 3 | Providing and fixing 1st quality MAT finished ceremic tilesize 300x300mm confirming to code IS : 15622 colour suchas white, grey, ivory, fume red brown, light green, light blueand other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). |
| 4 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) |
| 5 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.M15 grade Nominal Mix1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 6 | Construction of chamber in all type of soil with 300 mm thickmasonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation,20mm thick insider plaster in Cm 1:6, finished with floatingneat cement, 50mm thick M-15 grade C.C. flooring ,earthwork etc. complete as per design including disposal ofsurplus earth within a lead of 50 mtr. -do- size 450 x 450mm depth upto 0.5 M Cement cover withframe |
| 7 | Half brick masonry in Superstructure , above plinth level uptofloor V level using bricks of designation 75 |
| 8 | Brick work with F.P.S. bricks of class designation 75 insuperstructure above plinth level upto floor V level in allshapes and sizes in |
| 9 | Supplying and fixing Rollor Blinds of good quality andapproved make made out of Imported fabric including RollerMechanism and lock with chain system with all necessaryhooks etc. complete as per direction and sample approved byengineer-in-charge |
| 10 | Repair of existing steel glazed doors, windows and ventilator,MS sheet door, garge doors, compound wall gates etc. bywelding drilling complete include. Cost of welding rods andhire charge of welding meachine and TP etc complete |
| 11 | Renewing glass panes,with putty and nails wherever necessary Float glass panes of thickness 4 mm |
| 12 | Repair of door, window shutters including cost of material and labour for change of damaged : Shuttering Ply - 9mm thick (Commercial) Sqm. 598.00 |
| 13 | Repair of door, window shutters including cost of material and labour for change of damaged : Wire Gauge 14 mesh x 24 gauge Sqm. |
| 14 | Repair of door, window shutters including cost of material and labour for change of damaged : Aldrop of mild Steel 12\\" long x12mm dia |
| 15 | Repair of door, window shutters including cost of material and labour for change of damaged : Stopper of Aluminium with Single Rubber Gutka Each 33.00 |
| 16 | Repair of door, window shutters including cost of material and labour for change of damaged : Stopper of Aluminium with Double Rubber Gutka |
| 17 | Repair of door, window shutters including cost of material and labour for change of damaged : Steel Hinges For Stone Chowkhat ,4\\"size |
| 18 | Repair of door, window shutters including cost of material and labour for change of damaged : Mild Steel Tower Bolt 6\\" long |
| 19 | Repair of door, window shutters including cost of material and labour for change of damaged : Steel Handle 6\\" size |
| 20 | Labour charges for repair to door / window without using any material such as applying randha (finishing) tightening of bolts & screw etc. |
| 21 | Repair of door, window shutters including cost ofmaterial and labour for change of damaged : Style / rail of teak wood 30mm thick/ Aluminium Section 6\\" wide |
| 22 | Providing and fixing in cement sand mortar 1 : 4 single paitam (rebated) stone doors windows and ventilator frames of approved quarry :Size 100x 75mm |
| 23 | Providing and fixing fully panelled/partly panelled/ double leaf shutter frames for doors as per approved design and drawings with approved ordinary C.P./ oxidised steel fittings as per Annexure - 'A' and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete :35 mm thick Ivory coast woodgrade I |
| 24 | SS wire gauge 14 mesh x 24 gauge |
| 25 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' :35 mm thick .Decorative teak veneer both side |
| 26 | Providing and fixing 12 mm thick prelaminated three layermedium density (exterior grade ) particle board Grade I, TypeII conforming to IS : 12823 bonded formaldehyde syntheticresin ,of approved brand and manufacture in paneling fixed inaluminium doors ,windows shutters and partition frames withC.P. brass / stainless steel screws etc. complete as perarchitectural drawings and direction of engineer-in-charge. Prelaminated particle board with decorative lamination onboth sides. |
| 27 | Providing and fixing IS : 3564 marked aluminium extrudedsection body tubular type universal hydraulic door closer withdouble speed adjustment with necessary accessories andscrews etc. complete. |
| 28 | Structural steel work riveted, bolted or welded in built upsections, trusses and framed work, including cutting, hoisting(height upto 10 m) , fixing in position and applying a primingcoat of approved steel primer all complete: |
| 29 | Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred welded and grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C C block 15 x10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x10mm square bars welded to frame for paitam fixing float glass 4mm thick panes with glazing clips and metal sash putty and fixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coatedsuperior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge |
| 30 | Providing and applying white cement based putty overplastered surface to prepare the surface even and smoothcomplete Old Plastered Surface (two or more coats) |
| 31 | Providing and fixing S.S. Rod 30mm dia (304 grade ,16SWG) including brackets fixed withC.P. brass screws and rawl plugs, etc.,wherever necessary complete two side central all fittings |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 33 | Wall painting with plastic emulsion paint of approved brandand manufacture to give an even shade including allscaffolding: Old work (One or more coats ) |
| 34 | Providing & fixing UV stabilised fiberglass reinforced plasticsheet roofing upto any pitch including fixing with polymercoated „J? or „L? hooks, bolts & nuts 8mm dia. G.Iplain/bitumen washers complete but excluding the cost ofpurlins, rafters, trusses etc. The sheets shall be manufacturedout of 2400 TEX panel rovigs incorporating minimum 0.3%Ultra-voilet stabiliser in resin system under approximately2400 psi and hot cured. They shall be of uniformpigmentation and thickness without air pockets and shallconfoim to IS 10192 and IS 12866.The sheets shall beopaque or translucent, clear or pigmented, textured or smoothas specified 3.0mm thick (Wt. 5.0 Kg./Mtr. Sq.) |
| 35 | Providing & Fixing of ward robe shutters made out of 19mm thick BWP block board ISI of superior quality make with following details:Front side finishing with 1mm thick superior quality mica approved make and 0.8mm thick approved shade mica in the inner side. Covering with teak wood beading 25x12mm all the sides of shutter &35x12mm on outer frame for making good the wall joint including heavy brass S.S.fittings Handle200mm 2 Nos., Tower Bolt 150mm 2 Nos., Brass Lock 1 Nos.,Magnetic Catcher 2 Nos., Brass Hinges 75x40x2.5 mm 6 Nos.,SS Hanger Rod 20mm dia) complete as per drawing and design approved by Engineer in Charge. |
| 36 | Providing and fixing curtain rods of 1.25 mm thick chromiumplated brass plate, with two chromium plated brass bracketsfixed with C.P. brass screws and wooden plugs, etc., wherevernecessary complete 12 mm Please Enable Macros to View BoQ information |