| 1 | Supply, Retrofitting, testing & commissioning of secured Numerical Transformer high impedance REF Relay for 220/132 KV, 160MVA T/F-II (Only Alstom/ABB/Siemens Make) at 220 KV S/S Gokul with 6 no. digital input, 6 no. digital output, communication on IEC 61850 , Event logger disturbance recorder, time synchronization including retrofit material like wiring, cable ,TB, Channels, Feruls patch code and all consumable items etc for retrofitting. | Supply, Retrofitting, testing & commissioning of secured Numerical Transformer high impedance REF Relay for 220/132 KV, 160MVA T/F-II (Only Alstom/ABB/Siemens Make) at 220 KV S/S Gokul with 6 no. digital input, 6 no. digital output, communication on IEC 61850 , Event logger disturbance recorder, time synchronization including retrofit material like wiring, cable ,TB, Channels, Feruls patch code and all consumable items etc for retrofitting. |
| 2 | Supply, Retrofitting, testing & commissioning cyber secured Numerical Line Distance protection relay for 220 KV Agra-Gokul Line (Only Alstom/GE/Siemens Make) at 220 KV S/S Gokul with following along with retrofit material including retrofit material like wiring, cable , TB, Channels, Feruls patch code and all consumable items etc for retrofitting. Functions: 21G, 21P (5 zone-Quad, 1 phase trip), 68, SOTF, VT fuse fail, BRC, load encroachment 50. 51/67, 50N, 51N/67N, 50BF, 52PD, 46, 32 27, 59, 59N, 81U, 81O, 25, 79, 85, fault locator, communication on IEC61850, Event logger, disturbance recorder, Time synchronization of SNTP or IRIG-B, 5 CT I/P, 5 PT I/P, 20Nos digital input, 25Nos. digital output. | Supply, Retrofitting, testing & commissioning cyber secured Numerical Line Distance protection relay for 220 KV Agra-Gokul Line (Only Alstom/GE/Siemens Make) at 220 KV S/S Gokul with following along with retrofit material including retrofit material like wiring, cable , TB, Channels, Feruls patch code and all consumable items etc for retrofitting. Functions: 21G, 21P (5 zone-Quad, 1 phase trip), 68, SOTF, VT fuse fail, BRC, load encroachment 50. 51/67, 50N, 51N/67N, 50BF, 52PD, 46, 32 27, 59, 59N, 81U, 81O, 25, 79, 85, fault locator, communication on IEC61850, Event logger, disturbance recorder, Time synchronization of SNTP or IRIG-B, 5 CT I/P, 5 PT I/P, 20Nos digital input, 25Nos. digital output. |
| 3 | Supply, Retrofitting, testing & commissioning cyber secured Numerical Line Distance protection relay for 220 KV Gokul-Mant (Only Alstom/ ABB make) at 220 KV S/S Gokul with following along with retrofit material including retrofit material like wiring, cable , TB, Channels, Feruls patch code and all consumable items etc for retrofitting.Functions: 21G, 21P (5 zone-Quad, 1 phase trip), 68, SOTF, VT fuse fail, BRC, load encroachment 50. 51/67, 50N, 51N/67N, 50BF, 52PD, 46, 32 27, 59, 59N, 81U, 81O, 25, 79, 85, fault locator, communication on IEC61850, Event logger, disturbance recorder, Time synchronization of SNTP or IRIG-B, 5 CT I/P, 5 PT I/P, 20Nos digital input, 25Nos. digital output. | Supply, Retrofitting, testing & commissioning cyber secured Numerical Line Distance protection relay for 220 KV Gokul-Mant (Only Alstom/ ABB make) at 220 KV S/S Gokul with following along with retrofit material including retrofit material like wiring, cable , TB, Channels, Feruls patch code and all consumable items etc for retrofitting.Functions: 21G, 21P (5 zone-Quad, 1 phase trip), 68, SOTF, VT fuse fail, BRC, load encroachment 50. 51/67, 50N, 51N/67N, 50BF, 52PD, 46, 32 27, 59, 59N, 81U, 81O, 25, 79, 85, fault locator, communication on IEC61850, Event logger, disturbance recorder, Time synchronization of SNTP or IRIG-B, 5 CT I/P, 5 PT I/P, 20Nos digital input, 25Nos. digital output. |
| 4 | Supply, Retrofitting, testing & commissioning cyber secured Numerical Line Distance protection relay for 220 KV Feeders at 220kV S/S Chhata (Only Alstom/ ABB make) with following along with retrofit material including retrofit material like wiring, cable , TB, Channels, Feruls patch code and all consumable items etc for retrofitting.Functions: 21G, 21P (5 zone-Quad, 1 phase trip), 68, SOTF, VT fuse fail, BRC, load encroachment 50. 51/67, 50N, 51N/67N, 50BF, 52PD, 46, 32 27, 59, 59N, 81U, 81O, 25, 79, 85, fault locator, communication on IEC61850, Event logger, disturbance recorder, Time synchronization of SNTP or IRIG-B, 5 CT I/P, 5 PT I/P, 20Nos digital input, 25Nos. digital output. | Supply, Retrofitting, testing & commissioning cyber secured Numerical Line Distance protection relay for 220 KV Feeders at 220kV S/S Chhata (Only Alstom/ ABB make) with following along with retrofit material including retrofit material like wiring, cable , TB, Channels, Feruls patch code and all consumable items etc for retrofitting.Functions: 21G, 21P (5 zone-Quad, 1 phase trip), 68, SOTF, VT fuse fail, BRC, load encroachment 50. 51/67, 50N, 51N/67N, 50BF, 52PD, 46, 32 27, 59, 59N, 81U, 81O, 25, 79, 85, fault locator, communication on IEC61850, Event logger, disturbance recorder, Time synchronization of SNTP or IRIG-B, 5 CT I/P, 5 PT I/P, 20Nos digital input, 25Nos. digital output. |
| 5 | Supply, Retrofitting, testing & commissioning cyber secured Numerical Line Distance protection relay for 132kV Vrindavan- Chhata Line at 132kV S/S Vrindavan (Only Alstom/ ABB/ Siemens make) with following along with retrofit material including retrofit material like wiring, cable , TB, Channels, Feruls patch code and all consumable items etc for retrofitting.Functions: 21G, 21P (5 zone-Quad, 1 phase trip), 68, SOTF, VT fuse fail, BRC, load encroachment 50. 51/67, 50N, 51N/67N, 50BF, 52PD, 46, 32 27, 59, 59N, 81U, 81O, 25, 79, 85, fault locator, communication on IEC61850, Event logger, disturbance recorder, Time synchronization of SNTP or IRIG-B, 5 CT I/P, 5 PT I/P, 20Nos digital input, 25Nos. digital output. | Supply, Retrofitting, testing & commissioning cyber secured Numerical Line Distance protection relay for 132kV Vrindavan- Chhata Line at 132kV S/S Vrindavan (Only Alstom/ ABB/ Siemens make) with following along with retrofit material including retrofit material like wiring, cable , TB, Channels, Feruls patch code and all consumable items etc for retrofitting.Functions: 21G, 21P (5 zone-Quad, 1 phase trip), 68, SOTF, VT fuse fail, BRC, load encroachment 50. 51/67, 50N, 51N/67N, 50BF, 52PD, 46, 32 27, 59, 59N, 81U, 81O, 25, 79, 85, fault locator, communication on IEC61850, Event logger, disturbance recorder, Time synchronization of SNTP or IRIG-B, 5 CT I/P, 5 PT I/P, 20Nos digital input, 25Nos. digital output. |
| 6 | Supply, Retrofitting, testing and commissioning of directional Over Current & Earth Fault Relay at 220 KV S/S Chhata (Only Alstom/ABB/ Siemens make) with 6 no. digital input, 6 no. digital output, 4 Current, 4 Voltage Output communication on IEC , Event logger disturbance recorder time synchronization including retrofit material like wiring, cable ,TB, Channels, Feruls etc for retrofitting 04 current & 04 voltage input digital input -6 No Digital output-6 nos. | Supply, Retrofitting, testing and commissioning of directional Over Current & Earth Fault Relay at 220 KV S/S Chhata (Only Alstom/ABB/ Siemens make) with 6 no. digital input, 6 no. digital output, 4 Current, 4 Voltage Output communication on IEC , Event logger disturbance recorder time synchronization including retrofit material like wiring, cable ,TB, Channels, Feruls etc for retrofitting 04 current & 04 voltage input digital input -6 No Digital output-6 nos. |