| Sl. No. | Item Description |
| 1 | EARTH WORK |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 3 | All kinds of soil. |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lif. |
| 5 | CEMENT CONCRETE (CAST IN SITU) |
| 6 | Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth |
| 7 | 1:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 8 | REINFORCED CEMENT CONCRETE |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 10 | 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 13 | Foundations, footings, bases of columns, etc. for mass concrete |
| 14 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 15 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 16 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 17 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 18 | MASONRY WORK |
| 19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 20 | Cement mortar 1:6(1 cement :6 coarse sand) |
| 21 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 22 | Cement mortar 1:6(1 cement : 6 coarse sand) |
| 23 | CLADDING WORK |
| 24 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
| 25 | Granite stone slab of colour black, Cherry/Ruby red |
| 26 | Area of slab upto 0.50 sqnn |
| 27 | Area of slab over 0.50 sqm |
| 28 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 29 | Granite work |
| 30 | WOOD AND P. V. C. WORK |
| 31 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer- in-charge |
| 32 | Extruded section profile size 48x40 mm |
| 33 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds |
| 34 | Casement door single panel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides. |
| 35 | Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above) x (85 mm & above) (Height upto 2.5 metre). |
| 36 | STEEL WORK |
| 37 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 38 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 39 | Hot finished welded type tubes |
| 40 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 41 | FLOORING |
| 42 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm |
| 43 | Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.30 kg / sqm including grouting the joints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only. Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. Size of tile 800x2400 mm of all colours and shades. |
| 44 | FINISHING |
| 45 | 12 mm cement plaster of mix: |
| 46 | 1:6 (1 cement: 6 coarse sand) |
| 47 | 15 mm cement plaster on rough side of single or half brick wall of mix: |
| 48 | 1:6(1 cement: 6 coarse sand) |
| 49 | Finishing walls with textured exterior paint of required shade: |
| 50 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 51 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 52 | On steel work |
| 53 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 54 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 55 | Dismantling and Demolishing |
| 56 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 57 | Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) |
| 58 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 59 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 60 | In cement mortar |
| 61 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 62 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 63 | For thickness of tiles 10 mm to 25 mm |
| 64 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 65 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 66 | G.S. Sheet |
| 67 | ROAD WORK |
| 68 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in- charge. |
| 69 | Made of G.I. wire of dia 4 mm |
| 70 | SANITARY INSTALLATIONS |
| 71 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 72 | W.C. pan with ISI marked white solid plastic seat and lid |
| 73 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : |
| 74 | Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 75 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 76 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 77 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 78 | Internal work - Exposed on wall20 mm nominal dia Pipes |
| 79 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 80 | 20 mm nominal dia Pipes |
| 81 | NEW TECHNOLOGIES AND MATERIALS |
| 82 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 gram per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 83 | With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles. |
| 84 | Add correction factor 0.973 (i.e. 2.70%) on DSR items @ total of DSR rates x 2.70% i.e. 16442593.59.28X2.70%= -443950.26 |
| 85 | Add Cost index on DSR 2023 @ 4.03%on 15998643.56= 644745.34 |
| 86 | Non Schedule Items |
| 87 | Providing, fabricating, assembling and erection of Tensile Fabric Roof along with fabric of approved make having minimum weight of 900 gm/sqm with flame retardancy Bs2,d0 - EN 13501-1/ B1 - DIN 4102-1. High concentration PVDF lacquer on both sides. Colour of the fabric should be white and fabric welding should be done with high frequency welding machine. The whole tensile fabric roofing work shall be done over steel frames with all fittings and fixtures such as Galvanised MS Membrane/ End Plate, Shackles, Rigging Screws, Turnbuckles, swedge, fork, keder rods & galvanized MS strands/ cables with stainless steel end terminals complete as per Drawing/ Detail & as per specifications and as per the instructions of Engineer-in-charge. (Rate includes shop drawings for foundation, structural steel, canopy, cost of fabric including forming, cutting, fabrication, hot weld stich of fabric, transport to the site, assembling and installation with GI cables, hardware, Aluminium flat, EPDM gasket and required accessories wherever required complete including lifts up to all heights, tools and plants, and necessary scaffolding etc. required for all operations in all respect). Supporting structural steel frame and RCC foundation shall be paid separately. The minimum technical requirements/s pecifications are as below: Membrane shall be PVC/ PVDF coated with following Characteristics: Yarn : High Tenacity Polyester 1100 Dtex Surface Treatment : High Concentration PVDF coating on both sides Coated fabric Weight: 900 g/m² - EN ISO 2286-2Width : 2.5m-3.0m.) Minimum Tensile Strength Warp/ Weft:4200/ 4000N/ 5cm - EN ISO 1421 Minimum Tear Strength Warp/ Weft: 500/ 500N - DIN 53.363 Adhesion : 120 N/5cm - EN ISO 2411 Thickness : 0.72 mmElongation 24H - 100N/ 5cm (Warp/ Weft) : <1.2%/ <1.2% - EN 15977Residual Elongation : <0.5%/ <0.5% - EN 15977 Flame Retardancy: Bs2,d0 - EN 13501-1/ B1 - DIN 4102-1 SOLAR OPTICAL VALUESVisible Light Transmission (TV) : 5% - EN 410/ 9% - NFP 38511Visible Light Reflection (RV) : 87% - EN 410 Solar Transmission (TS) : 7% - EN 410 Solar Reflection (RS) : 79% - EN 410 Solar Factor (g) : 12.5% - EN 410 Micro Organism Resistance : Method A, Degree 0 Excellent – EN ISO 846-A Heat Transfer Coefficient [vertical/Horizontal] : U= 5.6/6.4 W/m2.KAcoustic Weakening Index : 13 dBA - ISO140-3 & ISO 717-1Solar Reflectance Index (SRI) : 90.5% - ASTME 1980-01 (Approach II)UV transmission (T uv) : 0% - EN 410 Quality Management: ISO 9001 Environmental Management : ISO 14001 |
| 88 | Note 1: Vetting of structural design and drawings for Tensioned Membrane Structure from IIT/NIT/Any Government Engineering College etc. to make \\"Good for Construction\\" drawings including MS pipe/structure and RCC foundation for the Tensile Canopy including submission of 06 sets of drawings, design and Technical Specifications etc., inclusive of all payment to IIT/NIT/Any Government Engineering College etc. for vetting all complete as direction and satisfaction of Engineer-in-Charge.Note 2: Actual curved area of canopy shall only be measured for payment.Note 3: Warranty of minimum 15 years on the fabric shall be given by agency.Note 4: This item shall be executed by associating the specialized agency approved by Engineer-in-Charge based on the qualification under eligibility criteria for specialized agency mention in NIT. |
| 89 | Providing and fixing premimum quality GRC cobbles of size not less than150x150x22 mm of approved design and shape laid in required colour and pattern in footpath & courtyard etc jointed with neat cement slurry mixed withpigment to match the shade of tiles, including cleaning etc, complete on 20 mm thick bed of cement mortar 1:4 (1cement:4coarse sand) |
| 90 | Providing and fixing of Premium Auditorium Chair with Smooth push-back reclining mechanism for effortless relaxation Ergonomically designed high backrest with superior lumbar and neck support Soft headrest filled with high-density PU for enhanced comfort Integrated cup holders on armrests for added convenience Premium upholstery using fabric of required colour for long-lasting finish and elegant appearance.Strong and durable internal structure suitable for heavy-duty commercial useModern and space-efficient design ideal for auditorium layouts1. Upholstery Material: Fabric / Auditorium Fabric Type: Woven fabric (breathable) GSM: 250 – 350 GSM. Double seam stitching Finish: Anti-fade, dust resistant2. Cushioning Foam Type: High Density PU Foam Seat Foam Density: 40 kg/m³ Back Foam Density: 32 – 40 kg/m³Foam Thickness: Seat: 60 – 90 mm Back: 40 – 70 mm3. Armrest & Side Panel Material: Heavy Duty ABS / PP Plastic Color: Matte Black Armrest Type: Fixed straight armrest with cup holderSide Cover: Upholstered panel with black frameaterial Specifications4. Frame & Structure Main Frame: Mild Steel (MS) Steel Thickness: 1.2 mm – 2 mm Finish: Powder coated black5. Base & Fixing Base Type: Pedestal leg fixed on base plate, Fixing: Floor anchor bolts, Base Plate. : MS plate 6 mm thick6. Cup Holder Diameter: 85 – 95 mm (3.3\\" – 3.7\\") Cup Holder Depth: 70 – 90 mm (2.7\\" – 3.5\\")Internal Ply:- 12 mm Thick Commercial PlyDimensions MeasurementSize:- Overall Height:- 42 – 44 Inches; Seat Width:- 22 – 24 Inches; Overall Width:- 34 – 36 Inches; Seat Depth:- 20 – 22 Inches; Armrest Height:- 24 – 26 InchesWarranty:- 3 years after installation on Mechanism, foam and Fabric against manufacturing defect. |
| 91 | Providing and fixing of Premium Auditorium Chair with Smooth push-back reclining mechanism for effortless relaxation Ergonomically designed high backrest with superior lumbar and neck support Soft headrest filled with high-density PU for enhanced comfort Integrated cup holders on armrests for added convenience Premium upholstery using fabric of required colour for long-lasting finish and elegant appearance.Strong and durable internal structure suitable for heavy-duty commercial useModern and space-efficient design ideal for auditorium layouts1. Upholstery Material: Fabric / Auditorium Fabric Type: Woven fabric (breathable) GSM: 250 – 350 GSM Double seam stitching Finish: Anti-fade, dust resistant2. Cushioning Foam Type: High Density PU Foam Seat Foam Density: 40 kg/m³ Back Foam Density: 32 – 40 kg/m³Foam Thickness: Seat: 60 – 90 mm Back: 40 – 70 mm3. Armrest & Side Panel Material: Heavy Duty ABS / PP Plastic Color: Matte Black Armrest Type: Fixed straight armrest with cup holderSide Cover: Upholstered panel with black frame4. Seat Mechanism (Foldable Seat) Mechanism Type: Gravity return / spring assisted Seat Base: MS frame + plastic coverSeat Folding Angle: approx 85° – 95°5. Frame & Structure Main Frame: Mild Steel (MS) Steel Thickness: 1.2 mm – 2 mm Finish: Powder coated black6. Base & Fixing Base Type: Pedestal leg fixed on base plate, Fixing: Floor anchor bolts, Base Plate: MS plate of 6 mm thcknesInternal Ply:- 12 mm Thick Commercial PlySIZE DETAILSOverall Chair Size ParameterOverall Height 37- 41 inch; Overall seat Width 22 – 24 inch; Overall width 34 – 36 inch; seat Depth (Seat Folded Up) 16 – 20 inch; Armrest height 24-26 inches. Warranty:- 3 years after installation on Mechanism, foam and Fabric against manufacturing defect |
| 92 | Providing & fixing of 06mm thick both side High pressure Exterior Grade laminate of approved quality & make . These are EN 438-Part 6 complying panels, which are manufactured by high pressure and temperature in a hot press. The core of the panel consists of desired numbers of imported, long fibre virgin kraft papers, impregnated with specially formulated double hardened Phenolic resin and another top layer of imported virgin Blue wool scale passed, decorative paper layer impregnated with melamine resin. The panels are flame retardant type class 1 as per BS:476 Part 7, ASTM E84 and EN 438-Part 6. Poly-methyle methacrylate UV protecting films are provided at the top of the Deco layer for optimum UV protection (passes 1500Hrs). HPL panels have a tested Flexural Modulus of ≥ 11,000 MPa and Flexural strength of ≥ 100 MPa which makes the product enormously sturdy from inside. This product shows no distortion in extreme climatic changes such as from -20°C to +80°C or from dry climate to a relative humidity in excess of 85% - 90%. HPL panels are equipped with a maximum possible weather resistance at extreme oceanic climates as it has duly passed the salt spray test conducted for 500 Hours. HPL panels pass a 3000 hours artificial weathering and are rated with a 5 for Grey scale rating & 7/8 for Blue wool rating. Density is 1.45gm/cm3 with 10 years warranty the cladding system will be installed on aluminium frame work on wall or other surface for making grid of maximum size of 600x600mm(c/c) as frame work wall lining work using rectangular section of size 38.10x25.40x1.44mm or other equivalent sections of approved make conforming to IS:1285 i/c providing & fixing with SS Anchor/dash/wedge fasterners or required dia nd size, scaffolding etc. Aluminium sections shall be smooth , rust free, straight, mitres or unshared and jointed mechanically wherever required including cleat angle,etc. all complete as per architectural drawing and as per direction of engineer-in-charg.Installation will be done via rivets/adhesive and 3M tape. |
| 93 | Providing & fixing 2mm Luxury Vinyl Roll, in desired tone, colour and pattern, Glue Down by SR 998, Termite and Bugs proof, Superior Stain and Scratch Resistance, Fire Resistance, Chemical Resistance, Zero Maintenance, Easy Soap & Water Cleaning, PUR Polyurethane reinforcement, Phthalate free all complete as per direction of Engineer - in-charge. |
| 94 | Electrical |
| 95 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 96 | Group A |
| 97 | Group C |
| 98 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 99 | Group A |
| 100 | Group C |
| 101 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 102 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 103 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 104 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 105 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 106 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 107 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 108 | 3 X 1.5 Sq.mm |
| 109 | 3 x4 Sq.mm |
| 110 | 6 x4 Sq.mm |
| 111 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 112 | 20 MM |
| 113 | 25 MM |
| 114 | 32 mm |
| 115 | Supplying and fixing of following sizes of PVC trunking with cover on surface(Wall,/Ceiling) having degree of protection as IP40, Rated current 500V, and making good the same as original complete etc. as required. |
| 116 | 100 x 50 |
| 117 | 32 X12.5 |
| 118 | Supplying and fixing following size of module frame on existing trunking including arranging the cover making good same as original complete etc as required. Make Legrand / Honewell/OBO betterman |
| 119 | 1-3 module frame |
| 120 | 4-5 module frame |
| 121 | 8 module frame |
| 122 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray with perforation, in convenient sections, joined with cover on cable tray to protect from seasoning including G.I. bolts & nuts, etc. as required. |
| 123 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 124 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" with perforation , in convenient sections, joined withcover on cable tray to protect from seasoning including G.I. bolts & nuts, etc. as required. |
| 125 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 126 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" with perforation , in convenient sections, joined with cover on cable tray to protect from seasoning including G.I. bolts & nuts, etc. as required. |
| 127 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 128 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 129 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 130 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 131 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 132 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 133 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 134 | Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 135 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 136 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 137 | Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 138 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 139 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 140 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 141 | 1 or 2 Module (75mmX75mm) |
| 142 | 4 Module (125mmX75mm) |
| 143 | 6 Module (200mmX75mm) |
| 144 | 8 Module (125mmX125mm) |
| 145 | 12 Module (200mmX150mm) |
| 146 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 147 | 5/6 Amp Switch |
| 148 | 3 pin 5 Amp Socket outlet |
| 149 | 15/16 amp switch(Geyser Control) |
| 150 | 6 pin 15/16 A socket outlet |
| 151 | Telephone Socket Outlet |
| 152 | Supplying and fixing two module stepped type electronic modular fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 153 | Supply & Fixing suitable size GI Box with modular plate and cover in front on surface or in reccess including provising and fixing 6 pin 5/6 and 15/16 amps moduler socket outlet and 15/16 amps moduler switch connection ect. as required. |
| 154 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 155 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 156 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.( For Geyser) |
| 157 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 158 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required |
| 159 | 1 Pair |
| 160 | 2 Pair |
| 161 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 162 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required. |
| 163 | Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 164 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 165 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 166 | Upto 450 mm sweep |
| 167 | Extra for fixing the louvers/ shutters complete with frame for an exhaust fan of all sizes. |
| 168 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL erification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should bein the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius :< 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required. |
| 169 | 1 run of cable |
| 170 | Supply, installation, testing, and commissioning of outdoor type 3-watt IP 65 LED foot light/ step light in Die cast aluminium housing and Polycarbonate diffuser, complete with connection, etc., as required. (Jaquar LFTL01S003XW or similar in Philips / Wipro /LT/ Havells) |
| 171 | Supply and fixing of 8 mm thick BWP/marine grade plywood wood board having a circular /rectangular hole to suit the sie of exhaust fan upto 450 mm on wall /window for etc as required including the cost of making hole, nuts and bolts, etc. as required. |
| 172 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.(BLDC Ceiling fan with minimum 2 year Warranty of Atomberg/ Usha/ Orient / Havells /Crompton make) |
| 173 | 1400mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 245 CM/Min (Minimum) |
| 174 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 175 | 36 watt |
| 176 | Supplying, installation, testing, and commissioning of minimum 10-12 Watt, 0.6 - 0.7 mtr (nominal size) LED Bollard Light fitting complete with LED module, electronic driver, diffuser, and all other accessories, minimum system luminous efficacy of 60 lm/W, IK 10, IP 65, CRI >= 7, CCT- 6500, Power Factor 0.95, Operating Voltage Range - 140- 270 Volt the bollard housing should be made up of metallic pipe duly powder coated with the mounting flange at the bottom, including providing 3 nos M10 foundation bolts, two numbers 32 mm. dia PVC pipe for cable entry (from the bottom of the foundation to the top of the foundation for cable entry), and providing the foundation of Cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size ) of size 0.3-metre dia and 750 mm height (250mm above ground and 500 mm below ground) including excavation as required and complete with connections, lugs, terminals, connectors for the connection of cable and wires in the fitting etc., complete as required. (Make:- Philips Mount LED Bollard 14 W or similar in Jaquar, Havells, and Wipro as per the sample approved by the Engineer in Charge.)Make : Twinkle Luxmax of Philips similar in Havells/ Wipro/ Bajaj |
| 177 | Supply, installation, testing and commissioning of 8.5 watts LED-based Vertical Wall mount External Light, 55 lm/W, IK 10, IP 65, CRI >= 7, CCT- 6500, Power Factor 0.95, Operating Voltage Range - 140- 270 with Die-cast aluminium spigot housing and complete with diffuser, LED module, electronic driver and all other accessories and clamping on wall with fastener as required including connection etc. as required. Make :BWS400 LED05 V CW PSU GR S1 of Philips similar in Havells/ Wipro/ Bajaj |
| 178 | Supply, installation, testing, and commissioning of 10-watt IP 66 LED UP-down wall Luminaire with driver in aluminium housing, dust proof and water resistant , elegant powder coating finish IP rating , IP-65 , CCT- Wrm White complete with connection, etc Lucent 2 way wall washer , as required.Make :Philips/ Wipro/ Bajaj/ Regent/ LT |
| 179 | Supply, installation, testing, and commissioning of 6-watt IP 67 GROUND BURIAL luminaire in diecast aluminium housing and stainless steel trim, driver, complete with connection, etc., as required. (Philips / Jaquar /Wipro /LT/ Havells) |
| 180 | Supply, installation, testing and commissioning of 45 watts LED-based post top luminaires, Warm White IP 65, with Die-cast aluminium spigot housing and complete with diffuser, LED module, electronic driver and all other accessories, having minimum system luminous efficacy of 95 lm/W, on existing street light pole/gate including connection etc. as required. Make :RUBYNEXTPT45WLED757PSYMTOPC of Havells similar in Philips / Havells/ Wipro/ Bajaj |
| 181 | Supply, installation, testing and commissioning of 45 watts LED-based Circular post top luminaires, IP 65, with Die-cast aluminium spigot housing and complete with diffuser, LED module, electronic driver and all other accessories, having minimum system luminous efficacy of 95 lm/W, on existing street light pole/gate including connection etc. as required. Warm white with CCT of 3000 k Required.Make : RINKPT45WLED757PSYMTOPC of Havells similar in Philips / Havells/ Wipro/ Bajaj |
| 182 | Supply, installation, testing, and commissioning of 15w/m LED strip lights with IP 65 ratings in different colours, including the Outdoor Power Supply (IP 65 rated), with surface mounted IP 65 aluminium profile with diffuser, complete with connection, etc., as required. |
| 183 | Supply, installation, testing and commissioning of aesthetically designed decorative banner double arm , on existing street light pole/gate including connection etc. as required. |
| 184 | Supply, installation, testing and commissioning of Track Mounted Warm White LED light, IP >43, with Pressure Die-cast aluminium housing and complete with PC diffuser, LED module, electronic driver and all other accessories, having PF> 0.9, THD<15%, CRI>80 minimum system luminous efficacy of 90 lm/W, on existing street light pole/gate including connection etc. as required. |
| 185 | Surface / Pendant of Industrial type 80W LED Linear lowbay Luminaire, Housing madeup Extruded Aluminium Alloy with PDC End Cap with inbuilt PIR sensor, UV Stablized Injection moulded PC Diffuser, Nano technology Powder coated in corrosion resistant, high efficiecy long life LED package, Life of 50K @ L70, System Efficasy >120 LPW (Total Lumens->9800), CRI>80 long life High Efficiency Driver with protections like mis wiring, short circuit, voltage range of 90-240V, THD <10%, PF > 0.95, IP66, IK08, Operating temperature of 0 deg C to 40deg C, 50Hz Frequency, Surge of 5Kv with additional SPD of 10Kv, complying to LM79 from NABL Accredited lab, LM80 for LED Source, Driver Safety Requirment STD (IS 15885-2-13), Photobiologial Safety Norms (IS 16108). (L- 924mm, W-121mm H-89mm) |
| 186 | Supplying installation testing and commissioning of 400mm sweep wall fan with thermal overload motor protection, delivery rate 85 CMM at 1330 rpm (or better) suitable for operation on 220-240V and 50Hz Ac supply etc required. Make: Crompton- Hiflo Wave plus/Havells/Orient/Usha/Almonard) |
| 187 | Supplying , installation testing and commissioning of emergency light LED surface mounted polycarbonate housing 20 watt and emergency mode 6 watt with system eficacy of >=105, emergency lumen 600 lumen IP 66 colour temperature of 5500 K average life 50000 hrs , THD <-10% suitable for operation on 140-270 volt 1 phase 50 Hz AC supply system , compelete with all accessories electronic driver , diffuser , directly on ceiling i/c connection earthing etc as required. |
| 188 | Providing and fixing 40 watt LED light column of 3.0 mtr height i/c 950 mm height light pillar, pole dia 100mm with high pressure die cast aluminium pipe , housing with cylindrical OPAL polycarbonate diffuser designed for rugged outdoor usage & IP 65 protection , colour Graphite gray , high bright discreet LED 3000*C +/- 500*C >= 70 , driver efficiency >= surge protection 4 KVA , power factor >= 90 % , THD <= 20% , Operating input voltage 150-270 Volt , Power consumption 30/40 watt , nominal voltage 220-240 volt , ambient temperature range -10*C to +40*C i/c fixing on CC foundation column with base plate 250mmx250mmx8mm weled at the bottom, including providing 04 Nos M10 foundation bolts, two numbers 32 mm. dia PVC pipe for cable entry (from the bottom of the foundation to the top of the foundation for cable entry), and providing the foundation of Cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size ) of size 510mm X 210mm including excavation as required and complete with connections, lugs, terminals, connectors for the connection of cable and wires in the fitting etc., complete as required. (Make:- Tinkle Luxmex /Bajaj /Philips/ Havells/Wipro) |
| 189 | Providing and fixing 2x45watt watt LED light column of 2.0 mtr height i/c light pillar, pole dia 100mm with high pressure die cast aluminium pipe , housing with cylindrical OPAL polycarbonate diffuser designed for rugged outdoor usage & IP 65 protection , colour Graphite gray , high bright discreet LED 3000*C +/- 500*C >= 70 , driver efficiency >= surge protection 4 KVA , power factor >= 90 % , THD <= 20% , Operating input voltage 150-270 Volt , Power consumption 30/40 watt , nominal voltage 220-240 volt , ambient temperature range -10*C to +40*C i/c fixing on CC foundation column with base plate 250mmx250mmx8mm weled at the bottom, including providing 04 Nos M10 foundation bolts, two numbers 32 mm. dia PVC pipe for cable entry (from the bottom of the foundation to the top of the foundation for cable entry), and providing the foundation of Cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size ) of size 300mm X 300mm and 1000 mm height (250mm above ground and 750 mm below ground) including excavation as required and complete with connections, lugs, terminals, connectors for the connection of cable and wires in the fitting etc., complete as required. (Make:- Tinkle Luxmex TDUL Elegant 02 /Bajaj /Philips/ Havells/Wipro) |
| 190 | Supplying, installation, testing, commissioning & erection of 3 metres long decorative Casted Iron Poles with base plate with a base plate of size not less than 200 x 200 x 12 mm, including 4 Nos, 16 mm dia, 450 mm long G.I. foundation bolts with the nuts, with supply and embedding 2 Nos. 50 mm dia DWC HDPE pipe sleeve for cable entry, with inbuilt cable end box, supplying fixing 1 nos 'C' series 6 amp, 10 KA, SP MCB, including providing fixing DIN rail, 60 amps connectors for termination of 2x 25 sq mm incoming and outgoing cables mounted on bakelite sheet, including providing foundation of cement concrete 1:1.5:3 (1cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) pedestal of size 400 mm x 400 mm x 1200 mm (200mm above ground and 1200 mm below ground) with steel reinforcement of (Thermo-Mechanically Treated bars of grade Fe-500D or more) horizontal tor bar stirrup 8mm dia @150c/c, verticle bars 4 nos, 12 mm dia including excavation as required, including all necessary lugs, earthing terminal etc., complete as required. (Without street light bracket) Make : Twinkle, K-Lite, Dwarka wala |
| 191 | Supplying and fixing following Decorative ornamantle wall mount brackets with Light Hanger with E27 Holder Base sutable for drop down mounting fixing & hanging with decorative Casted Iron pole complete with i/c wiring connection etc. as required. Make : Twinkle, Luxmex Model No BKT 210 / K-Lite,/ Dwarka wala |
| 192 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 193 | Single pole |
| 194 | Single pole and neutral |
| 195 | Triple pole |
| 196 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 197 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(Note : DB should be suitable for RCCB/RCBO as incomer.) |
| 198 | 6 way , Double door |
| 199 | 12 way , Double door |
| 200 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required |
| 201 | For 6 way, Double door SPN MCBDB |
| 202 | For 10 way/ 12 way, Double door SPN MCBDB |
| 203 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 204 | 8 way (4 + 24), Double door |
| 205 | Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. |
| 206 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 207 | 100 Amp, 30KA, FPMCCB |
| 208 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 209 | 40 A Double pole |
| 210 | 63 A Double pole |
| 211 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 212 | 63 A Triple pole and neutral |
| 213 | Supplying and laying of one number PVC/XLPE insulated and PVC sheathed/XLPE aluminium conductor power cable 1.1 KV grade of following size in the existing RCC/ HUME/ STONEWARE/ METAL/ DWC pipe as required. |
| 214 | 2 X 16 Sq.mm |
| 215 | 4 X 25 Sq.mm |
| 216 | 3.5 X 150 Sq.mm |
| 217 | Supplying and laying of one number PVC/XLPE insulated and PVC sheathed/XLPE aluminium conductor power cable 1.1 KV grade of following size in Masonry Open Duct Loose/loop/in panel etc. complete etc as required. |
| 218 | 2 X 16 Sq.mm |
| 219 | 4 X 25 Sq.mm |
| 220 | 3.5 X 150 Sq.mm |
| 221 | Supplying and laying of one number PVC/XLPE insulated and PVC sheathed/XLPE aluminium armored conductor power cable 1.1 KV grade of following size on surface as required. |
| 222 | 2 x 16 sq mm (clamped with 1mm thick saddle) |
| 223 | 4 X 25 Sq.mm (clamped with 1mm thick saddle) |
| 224 | 3.5 X 150 Sq.mm (clamped with 40 x 3 mm MS flat iron clamp) |
| 225 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 226 | 2 X 16 sq. mm (22mm) |
| 227 | 3½ X 150 sq. mm (50mm) |
| 228 | 4 X 25 sq. mm (28mm) |
| 229 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching(75 cm deep) and refilling etc. as required. |
| 230 | 50 mm dia nominal bore |
| 231 | 100 mm dia nominal bore |
| 232 | Supply and drawing of 3 x 2.5 sq mm PVC insulated, FRLS PVC sheathed copper conductor multi core flexible cable into the existing street light pole, making connections at one end with the street light fitting fixed to the top of the pole and the other end with the control gearbox, including drawing out the burnt-out wires from the pole if required, etc. as required. |
| 233 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 234 | 40 mm dia (OD-40 mm & ID-32 mm nominal) |
| 235 | 63 mm dia ( OD-63 mm & ID-51 mm Nominal) |
| 236 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 237 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 238 | Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. |
| 239 | 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 240 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 241 | Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 242 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required. |
| 243 | Bituminous portion |
| 244 | The road crossings of power cable through trenchless boring. Trenchless horizontal boring using Manual/ Machine Moling technique at 0.75 metre below the ground level for following size pipes, including survey of under ground utilities, excavation of pits, moling with the hole size not exceeding 20% of the pipe dia, backfilling, compaction and restoration of the pits to original condition etc. as required. The rates for moling, as indicated are inclusive of excavation of pits, backfilling, compaction and restoration of the pits to original condition. Any damages occurred to other utilities during the Moling operation shall be immediately notified and rectified by the contractor without any cost implication to the Department.The length of the Hole (excluding the sizes of the pits on both ends) shall be considered for the measurement of Moling length. However, intermediate pits will consider in the moling length.i) Upto 200 mm dia DWC HDPE / G.I. /PVC |
| 245 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 246 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 247 | Providing & Fixing 25mmx5mm GI strip on surface or in reccess for connections etc. as required. |
| 248 | Providing and fixing 6 SWG dia GI Wire on surface or in reccess for loop earthing alongwith existing surface/ reccess conduit / sub main wiring / cable as reqired. |
| 249 | Supplying, Installation, testing and commissioning of Factory built ceiling suspended chilled water double skin type horizontal/vertical air handling units of following capacity, made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with Polyurethane Foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 4 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with Totally Enclosed Fan Cooled TEFC) drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for Variable Frequency Drive (VFD)applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.)and industrial type thermometres (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration Isolation arrangement, noise level shall not exceed 70 dB. AHU shall be AHRI/Eurovent certified, fan shall be AMCA certified etc. Complete as per CPWD specification/drawings and as directed byEngineer-in-Charge. (Total static pressure considered is 50 mm WG). |
| 250 | 12000CFM |
| 251 | Supplying, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers,supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation to IS : 655 and approved drawings and specifications of following sheet thickness complete asrequired. |
| 252 | Thickness 0.63 mm sheet |
| 253 | Thickness 0.80 mm sheet |
| 254 | Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. |
| 255 | 25 MM |
| 256 | Supplying, Fixing, installation, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required. |
| 257 | Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. |
| 258 | Fire Damper |
| 259 | Actuator |
| 260 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclo sure with cover plate having locking arrangement and wa tering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 261 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 262 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 263 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run) |
| 264 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run) |
| 265 | Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
| 266 | Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
| 267 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 268 | Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 269 | Dismantling of the existing switch accessories like switches, sockets, and MCBs, etc., as required. |
| 270 | Dismantling of the existing ceiling rose, holder, and wall bracket and depositing the same with the listing of materials in the store. |
| 271 | Dismantling of existing fluorescent fitting from ceiling/ wall including making good the damage to match the adjacent surface, etc., as required. |
| 272 | Dismantling of the existing ceiling fan/ exhaust fan of any size installed in the building and depositing it in the MMC store. |
| 273 | Dismantling of the existing recessed vertical type or horizontal type TPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required. |
| 274 | Dismantling of the existing recessed SPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required. |
| 275 | Dismantling of the existing recessed switch board of light points/power points, power/light plug points/socket outlet metal boxes of any size, along with phenolic laminated sheet, switches, sockets, etc., making good the damage to match the adjacent surface, etc., as required. |
| 276 | Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it. |
| 277 | Above 25 mm conduits. |
| 278 | Up to 25 mm conduit. |
| 279 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. |
| 280 | Less credit for the unserviciable items dismantled items during execution of the work. |
| 281 | Assorted MCB TP AND TP&N & OTHER SWITCHGEAR |
| 282 | Assorted PIANO Type Switches |
| 283 | Assorted PIANO Type Sockets |
| 284 | Assorted Bell push/PIANO Type |
| 285 | Assorted Call bell buzzer single phase |
| 286 | Assorted Brass batten/ angle holder/Brass Bracket |
| 287 | Assorted Fan regulator/resistance type |
| 288 | Assorted Telephone Socket outlet |
| 289 | Assorted T.V. Socket outlet |
| 290 | Assorted Capacitor, 3.15/2.50/2.25 mfd |
| 291 | Assorted 1200/1400 mm sweep ceiling Fan with blades |
| 292 | Assorted Fresh Air FAN 200/250 |
| 293 | Assorted Exhaust fan 300/380/450 |
| 294 | Assorted Wall Bracket Fittings |
| 295 | Assorted fluorescent Light Fittings |
| 296 | Assorted Bulk Head Fittings |
| 297 | less credit for the dismantled Copper wire wires from light points/ circuit/ submain/power circuit wiring,. |
| 298 | less credit for the dismantled aluminium wire wires from light points/ circuit/ submain/power circuit wiring,. |
| 299 | Assorted metal switch box. |
| 300 | Assorted MCB DB SPN with out MCBs |
| 301 | Assorted MCB DB TPN with out MCBs |
| 302 | Assorted MCB SP |
| 303 | Assorted MCB DP |
| 304 | Assorted MCB TP AND TP&N |
| 305 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only |
| 306 | 2.0 TR with 5 Star BEE Rating |
| 307 | Providing extra copper tubing / piping for refrigerant, insulation and 3 core x 2.5 Sq. copper condutor cable for 1.5/2TR Split AC as per manufacturers specification , clamps, etc. complete as reqd. (two copper pipes one suction and one discharge line with wire and foam insulation tubing will be measured as one unit) . |
| 308 | Supply, Installation, testing and commissioning of wall mounted type voltage stabilizer suitable for 2.0 Ton Split Air conditioner with High / Low voltage cut off, thermal overload relay and Time Delay Relay, WORKING VOLTAGE RANGE : 150-285 Volts including connection etc. as required. (V-Guard make-Model VND 400 plus500 or similar of Totaline / Logicstat / Microtek/Luminous / Bluebird with minimum 2 year warranty.) |
| 309 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 310 | 40 mm |
| 311 | Providing and fixing CO 2 High Pressure Portable 4.5 kg Fire Extinguisher, filled with CO 2 Gas as per IS 15222, Gross Weight 16.4, empty weight 11.9 Kg, Control discharge mechanism fitted with 1 Meter Wire Braided Hose & Flat Horn with Diffuser Nozzle for dispersed discharge of CO2, Discharge Time 12 Sec, Average Discharge is 95%, Applicable on Class B, C and electrically started Fire, Fire Rating 55B, Internal coating is not applicable & Externalcoating is of enamel spray painting, Powder Coated Handle, Valve Confirm to IS 3224 ISI Marked, CO2 Cylinder construction: hot spinning by seamless pipes & bearing ISI mark, Body confirms to IS 7285 and PESO APPROVED,Extinguishers confirmed to IS 15683:2018 and ISImarked. [Make-Kanex/Ceasefire/Omex] ( 1 year warantee on fire extinguiser ) |
| 312 | Providing and Fixing ABC Type Fire Extinguisher Cap. 4 kg Filled with Mono Ammonium Phosphate Powder 90% confirms to IS 4308, Stored Pressure Type, UGTS Pressure Gauge, Gross Weight 6.7 Kg, Empty Weight 2.7 Kg, Can Height 490mm, Diameter 140 ± 10mm, Discharge Time 18 Sec, ntrollable discharge mechanism, Jet Range 3 Meters, Average Discharge is 92%, applicable on Class A,B & C and electrically started Fire, Fire Rating 4A:144B, Can Construction : Deep drawn & MIG welded, EPDM Rubber Hose with both end Aluminum crimped, Internal & External – Pure Polyester Powder coating (UV Resistant), Brass forged valves with safety Pin is of SS material, Made up from 1.6mm thick heet, ISI Approved IS 15683:2018.[Make-Kanex/Ceasefire/Omex] ( 1 year warantee on fire extinguiser) |
| 313 | Supply,installation,testing and commissioning of professional 3-way high-output full-range loudspeaker cabinet with 15\\" horn-loaded LF driver, 6-10\\" MF driver and 1-1.75\\" HF compression driver on rotatable constant directivity horn (70°-90°H x 40°V). Frequency response 85 Hz - 20 kHz (-10 dB), sensitivity ≥105 dB (1W/1m), min SPL ≥129 dB peak. Power handling: 750W RMS / 1500W program, bi/tri-amp ready. 18 mm birch plywood enclosure with rigging points, integrated handles, weather-resistant finish (IP55 equivalent).it should come with 5 years warranty with CE or FCC or UL certifications. make Audac FX3.15 / QSC KW153 / Martin Audio FH3 / Bose LT6403 |
| 314 | Supply,installation,testing and commissioning of 10\\"or more, high power, high sensitivity, 2-way loudspeaker. The speaker cabinet must have frequency response (-3dB) of 85 Hz-17 kHz or better, sensitivity (1W/1m) 95 dB SPL or more, delivering Max SPL of 120 dB or more with power handling pk 1000W or more. The speaker should have a nominal impedance of 8 ohm. OEM brackets should be supplied along with the product. it should come with 5 years warranty with CE or FCC or UL certifications. make AUDAC VEXO110/B / QSC AD-S12 / BOSE AMM112 / MARTIN Q 10 |
| 315 | Supply,installation,testing and commissioning of Subwoofer shall be a passive, high-performance, single 15\\" bass-reflex loudspeaker employing a long-excursion low-frequency driver with minimum 3\\" voice coil, delivering ≥500W AES continuous power handling, ≥2800W peak, 8Ω nominal impedance, ≥95 dB sensitivity (1W/1m), ≥123 dB maximum continuous SPL, and low-frequency extension to 41 Hz or below (-3 dB). Enclosure shall be plywood construction with durable protective coating and steel grille. Professional-grade connectors with link-through/parallel output shall be provided. it should come with 5 years warranty with CE or FCC or UL certifications. make AUDAC BASSO115/B / Bose AMS115 / QSC PL-SUB15 / Martin Audio SX115 |
| 316 | Supply,installation,testing and commissioning of amplifier shall be a 4-channel Class-D design delivering minimum 600W continuous per channel into 4Ω with bridging or power-sharing capability, frequency response should be min. 20 Hz – 20 kHz (±3 dB), THD+N ≤0.05/or ≤0.1 % at rated power, SNR ≥95 dB, and damping factor ≥200. Integrated DSP shall provide minimum 5-band parametric EQ per channel, selectable crossover filters, output limiter, and alignment delay with loudspeaker preset library. Dante or Equivalent version of respective brand should be available. it should come with 5 years warranty with CE or FCC or UL certifications. make AUDAC SMQ750 / BOSE PSX2404D / QSC CXD4.3 / Martin Audio iKON iK41 |
| 317 | Supply,installation,testing and commissioning of Class D Quad channel Dante compatible DSP power amplifier with specification as below or better to suit the power equirement of proposed speakers; Maximum Output Power, Quad Channel: 1200W @ 4 ohms Stereo, 2400W @ 8 ohms bridged, Frequency Response:20 Hz to 20 kHz (±1 dB) ,THD at 1 kHz < 0.05%, Input Level/Sensitivity: +21dBu/ 20dB or better, Signal to Noise Ratio >95 dB or better, DSP Features : Filters, PEQ, audio limiters, delay or more with built in protection such as Audio limiters, high temperature, DC, power limiting etc. complete as required. it should come with 5 years warranty with CE or FCC or UL certifications. make QSC CXQ-4K4 / BOSE PSX4804D / Martin IK41 / Audac SMQ1250 |
| 318 | Supply Installation Testing & Comissioning of loudspeaker that shall be a compact, high-performance, passive minimum 2-way system employing dual 8\\" drivers in a coaxial-plus-dedicated-LF configuration with 1.4\\" voice coil compression driver, delivering minimum 300W AES continuous / 1200W peak power handling, 8Ω impedance, ≥93 dB sensitivity (1W/1m), ≥119 dB maximum SPL, and frequency response of 80 Hz – 16 kHz (±3 dB). Dispersion shall be symmetrical and min ≥90° × 60° and it should come with 5 years warranty with CE or FCC or UL certifications. make AUDAC VEXO208I B / BOSE AMU 208 / QSC AD-S282H / Martin Audio CDD12 |
| 319 | Supply Installation Testing & Comissioning of loudspeaker shall be a compact, high-performance, passive minimum 2-way system employing dual 6.5\\" low-frequency drivers with 1.5\\" voice coils and a dedicated compression driver, delivering minimum 200W AES continuous / 800W peak power handling, 8Ω impedance, minimum ≥90.5 dB sensitivity (1W/1m), Min. ≥114 dB maximum continuous SPL, and frequency response of 80 Hz – 16 kHz (±3 dB). it should come with 5 years warranty with CE or FCC or UL certifications. make AUDAC VEXO206 / Bose AMU206 / QSC AD-S82H / Martin Audio CDD8 |
| 320 | Supply of professional digital cinema audio processor supporting Dolby Surround 7.1 / 5.1 formats with upgrade path to Dolby Atmos. 16-channel processing with internal crossovers (up to 3-way), high-resolution multi-rate EQ (1/12 octave), built-in booth monitor.Inputs: 8x AES3 (16ch), HDMI In/Out, Mic/RTA (XLR), 2x Non-Sync (RCA), 2x AES BNC. Outputs: 16ch Analog (DB25), AES67 / BLU-Link, HI/VI analog. Sample rates: 44.1/48/96 kHz, 16-24 bit. Touchscreen UI, web interface, RS-232/Ethernet control. 19\\" rack mount, 3.5HU, ~5.5 kg. it should come with 5 years warranty with CE or FCC or UL certifications. make DOLBY CP 950 |
| 321 | Supply,installation,testing and commissioning of audio DSP system shall comprise open-architecture, networked digital signal processor(s) operating at minimum 48kHz sampling rate with 24-bit or higher A/D-D/A conversion and floating-point processing. The system shall provide a combined minimum of 8 electronically-balanced analog mic/line inputs with switchable +48VDC phantom power and 32 electronically-balanced analog line outputs. Minimum 64×64 bi-directional Dante™/AES67 networked audio channels over standard CatX cabling shall be supported. DSP functions shall include parametric/graphic EQ, matrix mixing, automatic mic mixing, compressor/limiter, noise gate, delay, AGC, and source selection. Multiple networked units within the same product family are acceptable. Standard 19\\" rack-mountable. it should come with 5 years warranty with CE or FCC or UL certifications make XILICA FR1D / Q-SYS Core 510i /Bose ControlSpace EX-1280. |
| 322 | Supply,installation,testing and commissioning of professional-grade analog mixer with minimum 12 input channels comprising minimum 4 mono mic/line inputs and minimum 2 stereo line input channels, with minimum 2 group buses and 1 stereo main bus. Each mono channel shall feature balanced mic/line input with switchable +48V phantom power, 3-band EQ (LF/MF/HF) with minimum ±12dB range, and dedicated AUX send. The console shall include built-in digital effects processor with minimum 20 presets, balanced XLR stereo main outputs with maximum output level of +22dBu minimum, headphone output, and integrated USB audio interface for recording/playback. Frequency response shall be 20Hz–20kHz minimum. THD shall not exceed 0.05% at 1kHz.it should come with 5 years warranty with CE or FCC or UL certifications. make BEN Audio DAM-12BT/ Yamaha MG12XU/ Behringer QX1222USB |
| 323 | Supply & Installation of 2.5 sq mm professional speaker cable, 2-core stranded oxygen-free copper conductors, rated for 70V/100V distributed audio lines, flexible PVC/LSZH jacket, low-resistance for long speaker runs in permanent installations. Make PROCAB / RAMCRO / EXTRON / BELDEN / COMMSCOPE / NUETRIK |
| 324 | Supply and installation of audio connectors and termination hardware including: (a) Neutrik NL4 Speakon connectors (male and panel-mount) for all speaker cable terminations, (b) Neutrik NC3 XLR connectors (male/female) for all balanced audio connections, (c) Neutrik EtherCon RJ45 connectors for all Dante/network cable terminations, (d) Neutrik NJ3 6.3mm TRS jacks where required, (e) Amphenol/Neutrik DB25 connectors for multi-channel connections. All terminations shall be soldered (not crimped) for permanent installations and tested for continuity, polarity and shield integrity. make PROCAB / RAMCRO / EXTRON / BELDEN / COMMSCOPE / NUETRIK |
| 325 | Supply & installation of 32U floor-standing server rack, 600mm×1000mm, perforated front/rear doors, adjustable 19\\" mounting rails, integrated cable management, lockable side panels, heavy-duty castors with levelling feet, 3kW fan tray, PDU-ready, powder-coated steel construction. Valrack / CAYMON / R-TECH |
| 326 | Hanging arrangements for speakers — Supply and installation of professional speaker mounting hardware including OEM wall/ceiling brackets, U-brackets, yoke mounts or fly-frames as recommended by respective loudspeaker manufacturer for all installed speakers. All mounting hardware shall be rated for minimum 10× the weight of the speaker. Fasteners shall be stainless steel grade 304 with appropriate wall anchors (chemical/mechanical as per substrate). Safety cables (steel, 3mm, with carabiner) shall be provided for every suspended speaker. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail