Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead |
| 2 | Doors |
| 3 | Windows |
| 4 | Demolishing of brick work manually/mechanical means including stacking of serviceable material and disposal of unserviceable material 50mtr lead. |
| 5 | Demolishing RCC work manually/mechanical means including stacking steel bars and disposal of unserviceable material within 50 mtr lead. |
| 6 | Dismantling/Demolishing Cement concrete manually or mechanical means including disposal of material within 50 mtr as per direction (1:3:6) or richer mix |
| 7 | Dismatling tile work in floor and roof laid in cement mortat including stacking of materia for thickness 25mm to 40mm |
| 8 | Demolishing mud phoska in terracing and disposal of material within 50 mtr |
| 9 | Providing and fixing double scaffolding system ( cup lock type ) on the exterior side of building/ structure, upto 25 mtrs height above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 mtr.c/c, horizontal and vertical tubes joint with cup and lock system with M.s tube, M.S tubes Challis M.S clamps. The elevation area of the scafolding shall be measured for payment purpose. |
| 10 | Shifting of dismantled mulba from site to disposal site/outside city area by mechanical transport avg. lead upto 10km. |
| 11 | Dismantling of Plumbing work, electric work and other unseen items and disposal of material upto 150 mtr lead. |
| 12 | Plumber |
| 13 | Electrician |
| 14 | Labour |
| 15 | \\"PROPOSED SCHOOL\\" at Chaitanya Aashram, Jammu |
| 16 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be leveled and neatly dressed. (All kinds of soil)All kinds of Soils |
| 17 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 18 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated orstacked materials.All kinds of soil below 1.5 up to Bottom of PCC Bed-up to 3.0 M |
| 19 | Diluting and injecting chemical emulsion for PRE- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
| 20 | Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in- charge.Note : (1) Excess/less cement used than specified in this item is payable/recoverable separately. (2) Fly ash conforming to grade I of IS 3812 (Part-1) only be used as part replacement of OPC as per IS : 456. Uniform blending with cement is to be ensured in accordance with clauses 5.2 and 5.2.1 of IS: 456 -2000 in the items of BMC and RMC. |
| 21 | All works up to plinth level:M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for all heights: |
| 23 | Foundations, footings, bases of columns, etc. for mass concrete |
| 24 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.- OH Tanks |
| 25 | Suspended floors, roofs, landings, balconies and access platform, shelves cast in situ |
| 26 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 27 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 28 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500 D or more. |
| 29 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 30 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 31 | All works up to plinth level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 32 | All works above plinth level upto floor V level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 33 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 34 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1 : 4 (1 cement : 4 coarse sand |
| 35 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, color and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levelsGranite of any color and shade-Kitchen/Toilet Counters/sill/CopingArea of slab over 0.50 sqm |
| 36 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-ChargeGranite work-Kitchen Counter |
| 37 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 38 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia. & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood -100 x 50 mm |
| 39 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 40 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick |
| 41 | Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moistureproof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall bepaid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra paymenton this account shall be made.( Toilet Door )Frame size 50 x 100 mm |
| 42 | Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)35mm thick |
| 43 | Providing and fixing carbon steel galvanized ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.10 x 120mm |
| 44 | Providing and fixing bright /matt finished Stainless Steel Grade-316 handles of approvedquality & make with necessary screws etc. all complete.125mm |
| 45 | Providing and fixing ISI marked S.S. sliding door bolts of approved make with nuts and screws etc. complete :250x16 mm |
| 46 | Providing and fixing bright finished S.S. Grade-316 Matt/Polish finish of approved makes tower bolts (barrel type) with necessary screws etc. complete : |
| 47 | 300 x10 mm |
| 48 | 200 x10 mm |
| 49 | Providing and fixing Matt finished SS Grade 304 hanging type floor door stopper withnecessary screws, etc. complete.-Flush Doors |
| 50 | Providing and fixing Rubber buffer with necessary screws, etc. complete. |
| 51 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood50x12mm |
| 52 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works--MS Ladder at terrace |
| 53 | P/F stainless steel ( Grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 54 | Cut Out Railing |
| 55 | Main Staircase Railing |
| 56 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.10 x 80 mm-For Fixing S.S.Railings |
| 57 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 58 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 59 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) |
| 60 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) Above 50mtr |
| 61 | Providing and laying Polished Granite stone pattern flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer- in-Charge. ( CORRIDOR & ENTRANCE)Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 62 | Granite stone 18mm thick machine cut mirror polished granite (Sample of granite shall be approved by Engineer in Charge) in risers of steps, skirting, dado, walls and pillars laid on 12 mm thick (average) cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with white cement matched with pigment to match the shade of stone. (Entrance lobby skirting) |
| 63 | Making & Finishing Full Round Nosing as per Drawing & Details in Granite tread |
| 64 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colors, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.(size of tile 300 mm X 600 mm) (Toilet & Kitchen) |
| 65 | Providing and laying (Anti-skid) vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colors and shades, laid with approved make adhesive including providing 3mm X 3mm spacers on all sides of tile joints etc. complete. including grouting the joints with epoxy grout. (Epoxy grout to be paid separately) Size of Tile 600x600 mm (Toilet) |
| 66 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelingsystem and rubber mallet for placing the tiles gently and easily. Size of Tile 600x600 |
| 67 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600--Skirting |
| 68 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. Toilet |
| 69 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in white colors, of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.(size of tile 200/300 mm X 200/300 mm) (OVER HEAD TANK) |
| 70 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm center to center, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm center to center, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm center to center, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm center, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 71 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I (Entrance lobby) |
| 72 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 73 | GI Metal Ceiling Lay in plain Tegular edge Global white/colored Linear tiles of size 150/200 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.(Common area & Corridor) |
| 74 | GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 600x600 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. (TOILETS) |
| 75 | Providing and fixing multicell Polycarbonate sheet of Panel width 1040mm and 16 mm thick with 5 cells - 6 walls having wall flange thickness 1.8 mm & supporting wall flange thickness 0.50 mm. Extruded translucent panels with vertical standing seam at both sides of panels over structural steel / MS purlins shall be fixed at all levels including transportation, lift, scaffolding etc. conforming to specifications and directions of Engineer-in-Charge. (Rate of Steel Structure to be paid separately)Shaft covring at Roof Terrace level |
| 76 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600 mm to formgrid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6 mm thick with precut hole on both 25 mm flange to pierce into 12x50 mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directionsof the Engineer-in-Charge.With 15 mm thick Tegular edged light weight calcium sliciate false ceilingtiles |
| 77 | 12mm Cement plaster finished with a floating coat of neat cement of mix: 1 : 3 ( 1 cement : 3 fine sand) |
| 78 | External Plaster15 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 79 | Ceiling Plaster6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 80 | Finishing walls with textured exterior paint of required shade : New work (Two or morecoats applied @ 3.28 liter/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 81 | Distempering with 1st quality acrylic Washable distemper (ready mixed) having VOC content less than 50 gms/liter, of approved manufacturer, of required shade and color complete, as per manufacturer’s specificationTwo or more coats on new workLow VOC Washable Acrylic Distemper |
| 82 | Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm) |
| 83 | Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture . |
| 84 | French Spirit PolishingTwo or more coats on new works including a coat of wood fillerDoor Frames |
| 85 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. (Toilet + Balcony + Kitchen) |
| 86 | Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial remittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner.Terrace Water-Proofing |
| 87 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cementmortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:With average thickness of 120 mm and minimum thicknessat khurra as 65 mm. |
| 88 | Internal side-Cleaning the internal surface areas thoroughly so that they are free of all contaminants like dirt and laitance & to remove all the loose materials by various mechanical means. Removal of all surface imperfections, protrusions, loose concrete & filling of cracks using SBR latex modified Mortar in the ratio Cement: Sand (1:4) and 5% by weight of cement. Providing & grouting at construction joints with cementitious grout into each nozzles (1 mtr c/c) at regular intervals as per the requirements. Applying 3 coats of two component polymer modified cementitious coating of tensile strength of 1.0 N/Sq.mm as per ASTM D 412, elongation of 120% as per ASTM D 412, crack bridging of 2mm as per EN 1062- 7:2004, resisting 5 bars hydrostatic pressure as per DIN 1048 applied@ 3 kg/sq.mtr all over the slab including the angular fillets and extendable over the vertical walls .Finally sprinkling sand over the second coat for better adhesion with plaster. The interval between each coat of coating application is 6-8 hrs. A fibre mesh has to be placed in between the second and third coat of the polymer modified cementitious coating.The waterproofing system should be applied directly by the manufacturer with 10 years of complete system guarantee against leakages.Providing and applying 15-20 mm thick CM 1:4 for plastering admixed with integral waterproofing compound admixed @ 0.2litre/bag of cement as per manufacturer's specifications including curing etc.Additional for potable water tanks-Over the plaster providing & applying two coats of antibacterial antifungal food grade epoxy coating at a consumption of @250/Gms/sq.mtr as per CFTRI 21 CFR 175 - 300 of US - FDA, Water absorption nil as per ASTMC 870:90, adhesion strength of 2.5 N/mm2 as per ASTM D4541:02 applied with an interval of 6-8 hrs between each coat over the cured plastered surface as per manufacturer’s instruction.-UGT Tank |
| 89 | Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 90 | Carriage of material by mechanical transport from source to site of work. |
| 91 | Sand avg lead 25km |
| 92 | Aggregate avg. lead 25km |
| 93 | Bricks avg lead 15km |
| 94 | Construction of School for Divyang Children at Chaitanya Aashram, Jammu. (ELECTRICAL WORK) |
| 95 | Point wiring in PVC conduit, with modular type switch :- |
| 96 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core wire in surface / recessed PVC conduit, with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core wire etc. as required.(Wire Make : Finolex / RR / Polycab / KEI), (Conduit Make : AKG / BEC / Finolex / Polycab / Precision),Switches Make : Legrand / ABB / Clipsal/ Opale / RR / Polycab / Indo Asian-Elvira)Group-C |
| 97 | Wiring for group controlled light point/fan point/exhaust fan point/call bell point (without independent switch etc.) with 1.5 sqmm FRLS PVC insulated copper conductor single core wire in surface / recessed PVC conduit, with modular switch and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core wire etc. as required.Group C |
| 98 | Wiring for twin control light point with 1.5 sqmm FRLS PVC insulated copper conductor single core wire in surface/recessed PVC conduit, 2 way modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core wire etc. as required. |
| 99 | Power plug wiring in PVC conduit (2 x 4 sqmm.) :- |
| 100 | Wiring for light/power plug with 2 x 4 sqmm. FRLS PVC insulated, copper conductor single core wire in surface / recessed PVC conduit along with 1 x 4 sqmm FRLS PVC insulated copper conductor single core wire for loop earthing as required. |
| 101 | Wiring for light/power plug with 4 x 4 sqmm. FRLS PVC insulated, copper conductor single core wire in surface / recessed PVC conduit along with 1 x 4 sqmm FRLS PVC insulated copper conductor single core wire for loop earthing as required. |
| 102 | Circuit / Sub main wiring in PVC conduit :-Wiring for circuit / submain wiring alongwith earth wire with the following sizes of PVC insulated, copperconductor single core wire in surface/ recessed PVC conduit as required. |
| 103 | 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. Earth wire |
| 104 | 2 x 4 sq.mm. + 1 x 4 sq.mm. Earth wire |
| 105 | 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 106 | 2 x 10 sq.mm. + 1 x 10 sq.mm. Earth wire |
| 107 | 2 x 16 sq.mm. + 1 x 16 sq.mm. Earth wire |
| 108 | 4 x 10 sq.mm. + 2 x 6 sq.mm. Earth wire |
| 109 | 4 x 16 sq.mm. + 2 x 16 sq.mm. Earth wire |
| 110 | Supply and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required: |
| 111 | 20 mm. |
| 112 | 25 mm. |
| 113 | 32 mm. |
| 114 | 40 mm. |
| 115 | Supplying and fixing following size/ modules, GI Box alongwith modular base & cover plate for modular switches in reccess etc as required. |
| 116 | 75 mm x 75 mm (1 Module or 2 Module) |
| 117 | 100 mm x 75 mm (3 Module) |
| 118 | 125 mm x 75 mm (4 Module) |
| 119 | 200 mm x 75 mm (6 Module) |
| 120 | 125 mm x 125 mm (8 Module) |
| 121 | 200 mm x 150 mm (12 Module) |
| 122 | Supplying and fixing following Modular Base & cover plate on existing modular metal box etc as required. |
| 123 | 1 Module or 2 Module |
| 124 | 3 Module |
| 125 | 4 Module |
| 126 | 6 Module |
| 127 | 8 Module |
| 128 | 12 Module |
| 129 | Supplying and fixing suitable size GI Box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A Modular Socket outlet and 5/6 A Modular Switch,Connections etc as required. |
| 130 | Supplying and fixing suitable size GI Box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 & 15/16 A Modular Socket outlet and 15/16 A Modular Switch, Connections etc as required. |
| 131 | Supplying and fixing 3 pin, 5A Ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 132 | Supplying and fixing Call bell/ Buzzer suitable for Single phase, 230V complete. as required. |
| 133 | Installation, testing & Commissioning of Ceiling Fan, Including wiring the down rods of standard length (upto 30cm) with 1.5 sqmm FRLS PVC insulated, copper conductor, single core cable etc. |
| 134 | Installation of Exhaust fan in the existing opening, includingmaking good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 135 | Supplying and fixing following modular switch/ socket on the existingmodular plate & Switch Box including connection but excluding modular plate etc. as required. |
| 136 | 5/6 A Switch |
| 137 | 2-Way 5/6 A Switch |
| 138 | 15/16 A Switch |
| 139 | 3 pin 5/6 A Socket outlet |
| 140 | 6 pin 15/16 A Socket outlet |
| 141 | Telephone socket outlet (RJ-11) |
| 142 | TV antenna socket outlet |
| 143 | Bell Push |
| 144 | Supplying and fixing Two Module stepped type electronic fan regulator on the existing modular plate switch box including conncetions but excluding modular plate etc. as required. |
| 145 | Supplying and fixing modular Blanking on the existing modular plate & switch box excluding modular plate as required. |
| 146 | Supplying and drawing of UTP 4 pair Cat-6 LAN cable in the existing surface/ recessed Steel/PVC conduit as required.1 Run of Cable |
| 147 | Supplying and fixing suitable size GI Box with modular plate and cover plate on surface or in recess, including providing and fixing 2Nos. 3 pin 5/6 A modular socket outlet and 2Nos. 5/6 A Switch connections etc. as required. |
| 148 | Wiring including termination for the first light points controlled by MCB in distribution board (Cost of MCB taken seperately) with 2x2.5 sq.mm. PVC insulated copper conductor FRLS wires of 1100 Volts grade in concealed/exposed PVC conduits and 1.5 sqmm. earth wire. |
| 149 | Same as above but LOOP POINT i.e. wiring of point looped from first point with 2x1.5 sq.mm. PVC insulated copper conductor FRLS wire of 1100 volt grade in concealed/exposed PVC conduits and 1.0 sqmm earth wire |
| 150 | Providing 20 amp control switch and 6 pin 20 amp socket at different locations including connecting conduit and circuit by 2x4 + 2.5 sq mm copper wires. (For Geyser) |
| 151 | Providing & Fixing of modular plate type white RJ 45 CAT 6 Data outlet / information outlets on 1.0 mm tk G.I. Switch control boxes, with cover plate, grid plate, screws, etc with connections as required.1 nos. RJ 45 Data Outlet |
| 152 | Supply and drawing following pair, 0.5 sq.mm. FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface / recessed conduit as required.4 Pair |
| 153 | Supply and drawing of co-axial TV cable RG-6 grade, 0.7 mm. Solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed conduit asrequired. |
| 154 | Distribuiton Boards and Circuit BreakersSupplying and fixing following way, single pole and neutral, sheet steel, SP MCB distribution board consumer unit , 240 volts, on surface / recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections and powder painted including earthing etc. asrequired. (But without MCB / RCCB / Isolator) |
| 155 | 8-Way (2 + 8) Double door |
| 156 | 12-Way (2 +12) Double door |
| 157 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, TPN MCB distribution board, 415 volts,on surface /recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators).8 way (8 + 6 + 24), Double door |
| 158 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB)suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 159 | Supplying & fixing single pole, blanking plate in the existing MCB DB complete etc. as required. |
| 160 | Supplying and fixing following rating, double pole, (single phase and neutral) 240 volts, residual currentcircuit breaker (RCCB), having a sensivity current upto 300 miliampere in the existing MCB DB complete with connections, testing and commissioning etc. as required :40 amps. |
| 161 | Miscellaneous |
| 162 | S/F of hexagonal fan box with hexagonal side of approx. 80 mm.in length fabricated from 14 SWG G I. sheet incorporating with 12 mm. dia. G.I. round bar duly bent for supporting fan hanger and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour, T&P etc. for proper completion of work. |
| 163 | SUPPLY OF LIGHTING FIXTURESSupply of recess / surface, round / square, ceiling mounting LED Light fixture having Powder coated die cast aluminium housing with heat sink, glare free diffuser with uniform light distribution, PF above 0.9, efficacy above 90 lm/watt, pre wired with constant current LED driver set, suitable for 1 phase, 240 V, 50Hz, IP 20 complete in all respects. (colour temerature 3000oK / 4000oK / 6500oK - to be confirmed before supply)Make : Philips, Wipro, Bajaj, Legaro, RR Kabel) |
| 164 | 10 watt LED MIRROR LIGHT |
| 165 | 15 watt LED DOWN LIGHT |
| 166 | 12 watt LED DOWN LIGHT |
| 167 | 10 watt LED DOWN LIGHT |
| 168 | Supply of surface, wall / ceiling mounting LED T5 / T8 Tube Light fixture having Powder coated die cast aluminium housing with heat sink, PF above 0.9, efficacy above 90 lm/watt, pre wired with constant current LED driver set, suitable for 1 phase, 240 V, 50 Hz, IP 20 complete in all respects. (colour temerature 3000o/ 4000oK / 6500oK - to be confirmed before supply)Make : Philips, Wipro, Bajaj, Legaro, RR Kabel, Crompton)20 watt LED T5 / T8 Tube Light fixture (1200 mm long) |
| 169 | ERECTION OF LIGHTING FIXTURESThe Fixing and testing of lighting fixture shall include connection with wire of required length complete with all accessories including screws, nuts, wooden cleats, making hole in wall or ceiling and making good the same as required. |
| 170 | Recess / surface, round / square, ceiling mounting LED Light fixture |
| 171 | Surface, wall / ceiling mounting LED T5 / T8 Tube Light fixture |
| 172 | SUPPLY OF FANS AND EXHAUST FANS |
| 173 | Supply of AC 230/250 volts, 50 HZ energy efficient ceiling fan with standard down rod, blades, 2 nos. caps etc. complete(Make : Bajaj / Crompton / Havells / Ploycab / RR)1200 mm sweep (BEE 5 Star) |
| 174 | Supply of AC 230/250 volts, 50 HZ exhaust fans including providing nuts, bolts, mounting frame and other accessories etc. complete (Make : Bajaj / Crompton / Havells)300 mm sweep 900 rpm (BEE 5 Star) |
| 175 | Supply of 400 mm sweep AC 230/250 volts, 50 HZ wall mounting revolving fan with brackets etc. complete (Make : Bajaj / crompton / havells) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail