| 1 | Demolition of plain cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 2 | M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in sub base/plinth protection complete all as specified and directed. |
| 3 | M & L for 25mm thick PCC 1:2:4, type B0 using (12.5 mm graded crushed stone aggregate) as in floors to receive tiles complete all as specified and as directed. |
| 4 | Demolition of brick or stone masonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. |
| 5 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 6 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed. |
| 7 | Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 8 | M&L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 9 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound @ 200Ml per bag(50Kg) of cement or as per manufacture's instructions, finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as \\"Supply only\\". |
| 10 | M&L for rendering 5 mm thick in cement mortar (1:3) as in ceiling surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 11 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 12 | Complete removal of existing treatment & levelling of wall surface using MECHANICAL / ELECTRICALLY OPERATED SANDING / SCRAPING MACHINE WITH INBUILT VACCUM SUCTION system to suck the existing treatment as retrieved by scrapping/sanding etc. complete all as specified and as directed. |
| 13 | M & L for applying 1mm (Average) thick wall care putty on newly plastered or old prepared surfaces of wall complete all as specified and as directed. |
| 14 | M&L for preparation of new plastered surfaces of wall and ceiling and applying two or more coats of acrylic distemper 1st quality (ready mixed) having VOC content less than 50 gms/ltrs of required shade and colour complete as per manufacturer's specification complete all as specified and directed. |
| 15 | M & L for preparation of old plastered surfaces of wall and applying two coat of white wash complete all as specified and as directed. |
| 16 | M&L for preparation of old plastered surfaces of wall and ceiling and applying one coat of acrylic distemper 1st quality (ready mixed) having VOC content less than 50 gms/ltrs of required shade and colour complete as per manufacturer's specification complete all as specified and directed. |
| 17 | M & L for preparation of old plastered surfaces of ceiling and applying one coat of white wash complete all as specified and as directed. |
| 18 | M&L for preparation of old painted surfaces of wood or wood based materials of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 19 | M&L for preparation of old painted surfaces of steel and iron work of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 20 | M&L for preparation of old steel or iron surfaces of any description n exc 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed. |
| 21 | M & L for preparation of newly plastered surfaces of walls and applying Two or more coats of 100% Premium exterior acrylic emulsion paint of required shade, having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all specified and as directed. |
| 22 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing complete all as specified and directed. |
| 23 | M&L for coloured joint free non skid ceramic tiles (Matt finish) 7 to 8mm thick (square / rectangular) area of each tile exc 0.18 sqm but not exceeding 0.38 Sqm on vertical surfaces as skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 24 | M&L for coloured joint free non skid ceramic tiles (Matt finish) 7 to 8mm thick (square / rectangular) area of each tile exc 0.18 sqm but not exceeding 0.38 Sqm on vertical surfaces as skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 25 | M&L for glazed light coloured/printed ceramic tiles 350x250x7mm /450x350x7mm thick in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 26 | Demolition of stone slab and tiles of any description or thickness in floor, apron etc laid, bedded and pointed in cement mortar complete all as specified and as directed. |
| 27 | M & L for 18-20mm thick Mirror polished, high gloss finish Granite (absolute Jet Black) work in steps, jambs & soffits of chowkhat (including necessary pasting), pillars, window-cills, basin platforms, urinal partitions and like overb 15 mm thick screed bed in cement mortar 1:6, pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including necessary cutting for sunk basin/sink, making holes for fixing hinges, door bolts etc complete all as specified and as directed. |
| 28 | Providing edge moulding to 18-20mm thick granite stone slab including machine polishing to edge to give high gloss finish etc. complete all as specified and as directed. |
| 29 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm complete all as specified and as directed.Note : Rate shall be deemed to be include for cutting holes/demolition of masonry walls etc for taking down chowkhats and making good the damaged surfaces |
| 30 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4 sqm each complete all as specified and as directed. Note: Rate shall be deemed to be include for cutting holes/demolition of masonry walls etc for taking down chowkhats and making good the damaged surfaces. |
| 31 | Taking down shutter of any description area exc 1 sqm but n exc 2 Sqm each including builders hardware complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 32 | Taking down shutter of any description area exc 1 sqm but n exc 2 Sqm each including builders hardware complete all as specified and as directed. Please Enable Macros to View BoQ information |