| Sl. No. | Item Description |
| 1 | CIVIL PORTION OF THE WORK:- Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. |
| 2 | Double Under ream 300 mm Dia Pile of 7 M Depth in foundation with RCC M25 using 12mm size black hard granite chips including cost of boring but excluding the cost of MS/Tor steel and labour charges for cutting, bending, binding of steel. |
| 3 | Earth work in hard soil or gravelly soil within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge. |
| 4 | Filling fnd & plinth with excavated materials well watered & rammed including the cost of labour ,T&P etc. complete as directed by the Engineer in Charge. as per direction of the Engineer-in-charge |
| 5 | Dismantling of Prestressed / Reinforced cement concrete grade M-20 & above including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres. |
| 6 | Supplying, filling in foundation & plinth with sand in layers including watering and ramming with cost conveyance, royalities, taxes of all materials and labour with T&P required for the work etc. complete |
| 7 | Cement concrete of proportion (1:3:6) in foundation and floors using 4cm size black broken granite stone aggregates of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15cm(6\\") thick to the required level ramming, watering, curing etc. complete including cost and conveyance royality taxes of all materials and labour with T&P required for the work etc. complete i as per direction of the Engineer-in-charge. |
| 8 | Providing & applying Post constrution of Antitermite treatment by drilling 12 mm dia holes at a distance of 30cm@ junction of wall and floor about 300mm apart deep enough to each the soil below and chemical emulsion(PREMISE,IMIDACHLOPRIED 30.5SC OF BAYER MAKE mixed with475 ltr water) pumped these holes to soak the soil @1Ltr solution of each holea as per manufactures specification and the holes should be pluged with filling materials including cost of all materials,labour charges,conveyance and all taxes and hiring charges of machinaries as per direction of Engineer in charges. |
| 9 | Cement concrete (1:2:4) with 12mm hard granite chips(Crusher broken) per 1 cum. |
| 10 | Ground floor |
| 11 | First floor |
| 12 | Terrace floor |
| 13 | First class Fly ash Brick masonry using bricks of size 23cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. |
| 14 | Fly Ash. brick masonry of size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge |
| 15 | Ground floor |
| 16 | First floor |
| 17 | Terrace floor |
| 18 | First class Fly ash Brick masonry using bricks of size 23cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:4) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. |
| 19 | Ground floor |
| 20 | First floor |
| 21 | RCC work of M-25 grade with 20mm & down-grade size black hard granite(crusher broken) chips including hoisting&laying. |
| 22 | Pile cap |
| 23 | Grade Beam |
| 24 | Column & Beam |
| 25 | Ground floor |
| 26 | First floor |
| 27 | Terrace floor |
| 28 | Lintel |
| 29 | Ground floor |
| 30 | First floor |
| 31 | Chajja |
| 32 | Ground floor |
| 33 | First floor |
| 34 | Terrace floor |
| 35 | Roof Slab |
| 36 | Ground floor |
| 37 | First floor |
| 38 | Terrace floor |
| 39 | Staircase |
| 40 | Ground floor |
| 41 | First floor |
| 42 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge. |
| 43 | Ground floor |
| 44 | First floor |
| 45 | Terrace floor |
| 46 | :20mm thick grading plaster(1:4) on Roof slab as graded plaster on new works |
| 47 | Ground Floor Slab |
| 48 | First floor |
| 49 | Terrace floor |
| 50 | Providing 12 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 51 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 52 | Ground floor |
| 53 | First floor |
| 54 | Terrace floor |
| 55 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 56 | Ground floor |
| 57 | First floor |
| 58 | Terrace floor |
| 59 | Fixing of Industrial vetrified tiles in floors of Size 600x600mm of approved make coformaing to I.S:13755 laid on on 25mm thick bed of Cement mortar 1:4 ( 1 Cement : 4 sand ) and filling joint with white Cement of approved quality in slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of t |
| 60 | Supplying, fitting and fixing Granites Tiles of Above 0.10 Sqm & up to 0.4 Sqm (10mm.thick) . floor tiles of premium grade having thickness 7 mm to 8 mm confirming to IS-13755 of approved make conforming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 coarse sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-in-charge. |
| 61 | Ground floor |
| 62 | First floor |
| 63 | Supplying, fitting and fixing vitrified tile in floor of size 600 mm x 600 mm of approved make conforming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 coarse sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-in-charge. |
| 64 | Ground floor |
| 65 | First floor |
| 66 | Providing & Fixing Vitrified Tiles in Dados skirting and risers of steps on 12 mm thick cement plaster (1:3) Jointed with Neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete as per the direction of Engineer-In-Charge. |
| 67 | Ground floor |
| 68 | First floor |
| 69 | Supplying, fitting & fixing of well dressed and seasoned sal wood choukath of approved size wrought and put up in door frame including two coat of coaltaring to wall and lintel side faces, in all floors including cost, conveyance, taxes of all materials, cost of all labour, labour cess, T&P etc. complete as directed by Engineer-In-Charge. |
| 70 | Ground floor |
| 71 | First floor |
| 72 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design including cost of all door fittings and fixtures etc. completeand quality including cost of all door fittings and fixings and features etc. complete |
| 73 | Ground floor |
| 74 | First floor |
| 75 | Supplying, fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 76 | Ground floor |
| 77 | First floor |
| 78 | Supplying and fixing W.I. clamps 33cm to 38cm long of 35mm x 5mm size for doors and windows and ventilators including fixing in cement concrete (1:3:6) with 12 mm. to 20mm hard stone chips or in cement mortar (1:3) including cost of all materials. |
| 79 | Providing and fixing of Fixed Glazing with part Top hung of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6 mm thick “D” quality, galvanized as per IS-277 with zinc of 120 Gm/Sq.mtr) with paint specification being with primer of 5-7 microns and finished paint with polyster paint (Black /Pearl white/ Chocolate Brown) of 12-16 microns alongwith the alkyd backer at the back of 5-7 microns and the sizes of outer frame being of 46x52 mm and with all vertical and horizontal mullions are of 46x70 mm and fixed beadings are of 18x25 mm. Top hung shutter should be of 46 x 46 mm. Accessories / gaskets are to be used as per the manufacturer’s supply and specification like handle being made of high grade aluminium powder coated and with nylon receiver and gasket will be made of EPDM. All corner brackets are to be made of CRCA with zinc phosphating. The mullion caps and louvere d-clips should be of glass filled nylon. The sections are to be cut to length ,mitre joined with corner bracket and frames are fixed to the concrete/masonry walls by means of self expanding screws and glass to be used of 5 mm reflective with all taxes complete. |
| 80 | Supplying & fixing G.I Door with G.I pipe made out of G.I sheet including the cost of materials , labour etc all complete as per the direction Engineer-in-Charge. |
| 81 | Ground floor |
| 82 | First floor |
| 83 | Terrace floor |
| 84 | Painting two coats over iron work with approved Enamel paint over a coat of primming, including cost and conveyance of all materials to site, and all labour charges complete as per direction of E.I.C. |
| 85 | Ground floor |
| 86 | First floor |
| 87 | Terrace floor |
| 88 | Painting two coats over wood work with approved Enamel paint over a coat of primming, including cost and conveyance of all materials to site, and all labour charges complete as per direction of E.I.C. |
| 89 | Ground floor |
| 90 | First floor |
| 91 | Finishing wall surfaces with Acrylic wall putty (Water based) of approved make and finished smooth and even surfaces to receive painting including cost of all materials taxes, labour T&P etc. |
| 92 | Ground floor |
| 93 | First floor |
| 94 | Terrace floor |
| 95 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) weather seal coat exterior grade of approved make & shade manufactured by reputed manufacturer like NEROLAC / ASIAN / BERGER / DULOX or equivalent to make an even finished surface over a coat of primer with water bond cement primer in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. |
| 96 | Ground floor |
| 97 | First floor |
| 98 | Terrace floor |
| 99 | Wall painting 2-coats with plastic emulsion paint of approved shade on over one coat of primer new work 1coats to give an even shade excluding cost of paint. |
| 100 | Ground floor |
| 101 | First floor |
| 102 | Terrace floor |
| 103 | Supplying fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia. Of 2mm thick circular pipe with balustrade of size 32mmx32mmx2mm @ 0.90mtr C/C and stainless square pipe of size 32mmx32mmx2mm in 3 rows in staircase as per approved design and specification etc all completed. |
| 104 | Ground floor |
| 105 | First floor |
| 106 | Providing fitting and fixing of false ceilling with Aluminum anodised T section No 3215 with 2'-0\\" center to centre, L section No 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and P.V.C plug and the Aluminium grid 2'-0\\" x 2'-0\\" using 12.5 mm thick gypsum board of size 6'x4'suspended from ceilling etc complete as directed by the Engineer-in-charge |
| 107 | Ground floor |
| 108 | First floor |
| 109 | Construction of GSB by providing close graded GSB grading-VI materials as per Table 400-1, spreading in uniform layers with mortar grader on prepared surface mixing by mix in place method with rotavator at OMC and compacting with V.R.R to achieve the desired density complete as epr clause No.401 of MORT&H specification for road & Bridge work (4th revision) |
| 110 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction as per Technical Specifications and as per Clause - 305.3.4 of MoRT&H Specifications for Road & Bridge works (5th Revision). |
| 111 | Earth work in all kinds of soil frombarrow pit for filling and carriage of earth by mechanical means with average lead of 5km including loading and unloading at road alignment including dressing and levelling & approved profile complete as per direction of the Engineer-in-charge |
| 112 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make,design,colour and size made by Block making machine with proper compaction laid in required pattern etc.complete |
| 113 | Supplying and fixing of Pre-Cast Kerb Stone of size 300x300x150 mm of M-30 Grade of approved make,design,colour and size made by Block making machine with proper compaction laid in required pattern etc.complete |
| 114 | P.H PORTION of Work:- Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor C-PVC pipes conforming to pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge (Ashirbad/Supreme/Oripalst)GF Floor -20mm dia C-PVC pipe (Ashirbad/Supreme/Oripalst) |
| 115 | 25mm dia C-PVC pipe |
| 116 | 1st Floor- 20mm dia C-PVC pipe |
| 117 | 25mm dia C-PVC pipe |
| 118 | Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/04 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast) Ground Floor 25mm UPVC ASTM Pipe |
| 119 | 32mm UPVC ASTM Pipe |
| 120 | 1st Floor 25mm UPVC ASTM Pipe |
| 121 | 32mm UPVC ASTM Pipe |
| 122 | 40mm UPVC ASTM Pipe |
| 123 | 50mm UPVC ASTM Pipe |
| 124 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar ( 1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.G. Floor |
| 125 | 1st Floor |
| 126 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per the direction of the Engineer in chargeG. Floor |
| 127 | 1st Floor |
| 128 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge250mm to 375mm thick wall G. Floor |
| 129 | 1st Floor |
| 130 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. |
| 131 | 15mm dia long body Bib Cock cock (Jaquar)-CON-CHR-107KN |
| 132 | 15mm dia CP S.B Bib cock (CON-CHR-037KN) |
| 133 | 20mm dia CP concealed stop cock(Jaquar)CON-CHR-087KN |
| 134 | 15mm dia CP angle stop cock (FLR-ACR-5053N) |
| 135 | 15mm dia CP Pillar cock (Jaquar)CON-CHR-021KN |
| 136 | HAND SHOWER (HEALTH FAUCET) WITH 1 METER (Jaquar- ALD-CHR-565 |
| 137 | 15mm dia Two way Bib Cock (Jaquar)-CON-CHR-041KN |
| 138 | Shower Arm (SHA-CHR-477) |
| 139 | Over head shower 100mm dia round (OHS-CHR-1999) |
| 140 | 25mm dia brass or gun metal full way valve(shakti make) |
| 141 | 32mm dia brass or gun metal full way valve(shakti make) |
| 142 | 40mm dia brass or gun metal full way valve(shakti make) |
| 143 | 50mm dia brass or gun metal full way valve(shakti make) |
| 144 | 15mm dia CP Flange |
| 145 | 15mm dia CP Extention Nipple |
| 146 | 125mm CP grating |
| 147 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 1000 Ltr Roto-moulded water storage tank (Syntax Make) 3 layer on the roof of Second floor |
| 148 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In (Ashirbad /Oriplas/Oriplast)Ground floor |
| 149 | 110mm dia U-PVC SWR pipe |
| 150 | 75 mm dia UPVC SWR Pipe |
| 151 | 110mm U-PVC door tee |
| 152 | 110mm U-PVC Plain tee |
| 153 | 110mm U-PVC door bend |
| 154 | 110mm U-PVC plain bend |
| 155 | 110mm dia U-PVC 'P' trap |
| 156 | 110mm dia U-PVC Plain Shoe Bend |
| 157 | 110mm dia U-PVC offset with out ear |
| 158 | 110mm dia U-PVC cowl |
| 159 | 75 mm dia UPVC plain bend (supreme/ashirvad) |
| 160 | PVC clamp suitable for 75 mm to 110mm dia pipe |
| 161 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. One piece commod(Hindware)ELEMENT Cat No.92084. |
| 162 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge. 550mmx440 mm size wash hand basin With porcelain pedestal (Parryware/Hindware/Cera/Somany/Kerovit) |
| 163 | Supplying all materials,labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mmx600mm long CP towel rail |
| 164 | CP Towel ring |
| 165 | Supplying all materials ,labour ,T&P and fixing CP Soap Holder complete with CP brass brackets fixed to wooden plugs with chromium plated brass screws etc.all complete as per specification and direction of Engineer-in-charge. CP soap holder |
| 166 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge.600mmx125mm glass shelf with CP/NP guard rails |
| 167 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in chargeDesign mirror(Parryware) |
| 168 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etcall complete as per direction of the Engineer in charge. |
| 169 | Ground Floor;- |
| 170 | Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 171 | Ground Floor;- |
| 172 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc all complete as aper specification and direction of the E.I.C. |
| 173 | Ground Floor;- |
| 174 | FIrst Floor |
| 175 | Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1\\"-6\\" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge. |
| 176 | In , First floor |
| 177 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge . |
| 178 | Ground Floor;- |
| 179 | FIrst Floor |
| 180 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany / Johnson to be pre-approved 600 x 600mm of size In Ground Floor |
| 181 | Ground Floor;- |
| 182 | FIrst Floor |
| 183 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany 300mm x 600 mm size of |
| 184 | Ground Floor;- |
| 185 | FIrst Floor |
| 186 | Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 3.00mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter with FRP frame of size 45x90mm. (Darwaja /Exon Door make) 5x0.75x2.10= |
| 187 | 1x0.90x2.10= |
| 188 | Louvers 6x0.60x0.60= |
| 189 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm |
| 190 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm |
| 191 | R.C.P.C Cover |
| 192 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm |
| 193 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit |
| 194 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. |
| 195 | 110mm dia U-PVC Alround Concrete |
| 196 | 160mm dia U-PVC Alround Concrete |
| 197 | Construction 1 nos 20 users RCC Septic tank |
| 198 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 199 | 1x3.00mx1.80x1.50m= |
| 200 | - do - with addl. Depth of 1.5 m |
| 201 | 1x3.00mx1.80x0.0.30m= |
| 202 | Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department. |
| 203 | 1x3.00x1.80x0.70= |
| 204 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge |
| 205 | In ground floor |
| 206 | 1x3.00mx1.80x0.15m= |
| 207 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 208 | In ground floor |
| 209 | 1x3.00mx1.80x0.15m= |
| 210 | Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 211 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 212 | Roof Slab |
| 213 | Out Side |
| 214 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 215 | In ground floor |
| 216 | Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 217 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 218 | Supplying all materials, labour, T&P and fitting and fixing S.W.Tee of size 160mx160mx160m as per P.H.D.specification and direction of the E.I.C. |
| 219 | Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete. |
| 220 | Supplying all materials, labour, T&P and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. |
| 221 | 110mm diameter U-PVC SWR pipe |
| 222 | 110mm dia U-PVC Plain shoe bend |
| 223 | 110mm dia U-PVC Cowl |
| 224 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 225 | Sinking of 150mm size tube well through hand boring(water jet)method (1 nos.) |
| 226 | Supplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge |
| 227 | Supplying all labour, T&P and transporting the boring pipes, top casing , grouting pipes, P.V.C pipes and fittings, P.V.C well screens, cement, bentonite and gravels etc to the worksite including loading and unloading etc all complete as per direction of Engineer in charge |
| 228 | Supplying all labour, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kinds of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets (whenever required) etc and withdrawing the boring pipes, washing and keeping the bore clear for logging if required all complete as per direction of Engineer in charge |
| 229 | Drilling pilot bore from 0 to 360 metres |
| 230 | Supplying all labour, T&P and reaming the pilot bore to the following sizes and depths without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction of Engineer in charge |
| 231 | Reaming 100mm to 150mm dia |
| 232 | from 0 to 360 metres |
| 233 | Reaming 150mm to 200mm dia |
| 234 | from 0 to 360 metres |
| 235 | Reaming 200mm to 250mm dia |
| 236 | from 0 to 360 metres |
| 237 | Supplying all labour, T&P and jointing materials and lowering the 300mm dia top casing pipes into the position and removing the same after use all complete as per direction of Engineer in charge |
| 238 | from 0 to 360 metres |
| 239 | Supplying all labour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge |
| 240 | 150 mm dia PVC casing pipe |
| 241 | from 0 to 360 metres |
| 242 | Cost of 150 mm dia PVC ASTM pipe (sch-80) |
| 243 | Cost of 150mm dia PVC slott cutting |
| 244 | Cost of 150mm dia C.I. cutter plug |
| 245 | Cost of bentonite powder |
| 246 | Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction of the Engineer in charge |
| 247 | Supplying all materials, labour, T&P and packing the bore with river sand over the gravel pack etc all complete as per the direction of the Engineer in charge |
| 248 | Supplying all labour T&P and grouting with cement slurry for sanitary sealing in the bore around the upper most 3 metres of 125/100mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge. |
| 249 | Cost of Cement |
| 250 | Supplying all labour, T&P and developing the tube well by 8 hours continuous pumping per day for a minimum of 7 cosecutive days or till clear sand free water is obtained as per the direction of the Engineer in charge |
| 251 | Fixing of submerssible pump set |
| 252 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge |
| 253 | 1.50 H.P single phase (vertcal submersible pump motor) 3 stage head range 20 to 35 metres, discharge 145 to 110 L.M.P with outlet dia of 25mm |
| 254 | DOL Control panel |
| 255 | 2.50sqmm flat cable |
| 256 | 20mm dia rigid UPVC pipes |
| 257 | Steel rope with cover |
| 258 | Well cap |
| 259 | 50mm size CI bracket |
| 260 | 32mm dia steel short piece |
| 261 | Labour charges for lowering including transportation |
| 262 | Supplying all materials, labour, T&P and constructing Bore well protection chamber of the inside size 650x650x1000hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4) inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. |
| 263 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge |
| 264 | 32mm HDPE pipes |
| 265 | EI PORTION OF THE WORK:- Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (anti bactorial & flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 266 | GROUP-A |
| 267 | GROUP-B |
| 268 | GROUP-C |
| 269 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 270 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 271 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 272 | Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 273 | Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius-NEXT GEN)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 274 | Supplying,fixing of 3x6A Plug on the separate board with complete fitting by 3 nos 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius-NEXT GEN)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 275 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 276 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 277 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 278 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 279 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4) |
| 280 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 281 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 1 nos single core 1.5 sq. mm copper wire for phase in existing conduit (invertor point) |
| 282 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 283 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 284 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 285 | Sub-Head II (Light fitting Fixture & Fan) |
| 286 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 287 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 288 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator) |
| 289 | Supplying an fixing of recess/surface mounted 2'x2' 36 W(595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5years. |
| 290 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 291 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 292 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 293 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 294 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) |
| 295 | Supplying an fixing of wall up/down column LED 24W pressure die cast iron aluminium high transmitive PMMA defuser having exterior wall glazing with power consuption max. up to 24w ,system lumens output 3000 lumens LED chip life 50000 burning hours at L70 maximut tested for 10k hours for complayance of TM21 Projection.The LED used shall be CTC of 5700K.Luminair should be isolated & mulitstage constant current APFC type. The driver should BIS Registed with input voltage range of 150v to 270v(normal rated voltage-240v)with max. 2 kv surge protection PF>0.95,THD <15%,IP 20.Manufacture should have in house NABL accredited LAB Manufacturer need to submit 1)LM79 Test report in house NABL accredited LAB,2) LM80 Text certificate for the LED Chip manufacturer,3)Photobiological safety test report as per IS 16108. 2012/EN62471 from LED chip manufracturer . . (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5years. |
| 296 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 297 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years |
| 298 | 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR LIGHT,ComputerDB) |
| 299 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 300 | 8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR POWER & INDOOR AC DB)Warranty on DB is 3 years |
| 301 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 . the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years. |
| 302 | Supplying and fixing 40Amps 4P 415 volts, MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years |
| 303 | Supplying and fixing 40 Amps rating,4P 440V, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 304 | Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 305 | Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years. |
| 306 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year. |
| 307 | (Earthing) INSTALLATION |
| 308 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 309 | Supplying,installation,testing & commissioning of materials and installation ofcopper earth plate 600mmx600mmx3.18mm thick ISI marked with copper nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 310 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 311 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 312 | CABLING AND END TERMINATION MAIN AREA |
| 313 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 314 | 4core x 16 sq mm |
| 315 | 4 core x 6 sq mm (for small power) |
| 316 | 3.5core x 35 sq mm |
| 317 | 3.5core x 50 sq mm |
| 318 | LAYING OF CABLE |
| 319 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 320 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 321 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 322 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 323 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge. |
| 324 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 325 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 326 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 327 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 328 | 4 core x16sq mm |
| 329 | 3.5 core x35 sq mm |
| 330 | 3.5 core x50 sq mm |
| 331 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 332 | 50 mm dia |
| 333 | PANELS |
| 334 | MAIN CONTROL PANEL AT GF |
| 335 | S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 3 year & compelete test certificate must be submitted along with panel board including component list.80X10MM Separate Aluminium Earth bus bar should be installed. |
| 336 | In commer-1- 1 no space for 3PH KWH METER with 01 number of 125A(100-125) 4P Icu=100%Ics,25Ka LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS/ ABB Formula(FROM EX KVA TRANSFORMER) |
| 337 | In commer-2-01 number of 100A 4P Icu=100%Ics,36kA LSIG MCCB with TMR ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS/ ABB Formula) (DG 160 KVA INCOMMER) |
| 338 | In commer-2- 01 no of 100A 4P onload changeover switch (125 KVA DG 01 NO)(Make-ABB/Siemens/Schneider) |
| 339 | Busbar-1&2 04 numbers of 200Amps copper busbar with 1.6A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) |
| 340 | Out going- 4 numbers of 32A rating,10 KA breaking capacity,C series, 4P MCB(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200) |
| 341 | Out going- 4 numbers of 63A rating,10 KA breaking capacity,C series, 4P MCB (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200) |
| 342 | Out going- 6 numbers of 32A rating,10 KA breaking capacity,C series, 2P MCB (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200) |
| 343 | Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 344 | (ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data. |
| 345 | 2 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB(Make-LEGRAND/ Siemens/ Schneider/ABB/OBO/DEHN) |
| 346 | UPS SYSTEM(For COMMON AREA) |
| 347 | Supply ,installation ,testing & commissioning of 5KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sicuency corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 8 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric / APC/ VERTIV) LOAD OF EM) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD. |
| 348 | CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER |
| 349 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 350 | Supplying,fixing of FLOOR RACE WAY WITH JUNCTION box GALVANIZED(GC) type AS PER EN-ISO-1461 , with internal dimensions of size 38mm(H) x 225mm(W), of MAKE- Profab/OBO/Neidax .(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of Engg.-in-Charge. |
| 351 | ELV Subhead- 1 (Lan System) |
| 352 | SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit |
| 353 | SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit |
| 354 | SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit |
| 355 | FIRE FIGHTING |
| 356 | FIRE EXTINGUISHERS |
| 357 | Providing and Fixing ISI marked ABC stored pressure type Fire extinguisher of 6 Kgs. Capacity confirming to IS: 15683 with discharge hose, nozzle, Mono Amonium Phosphate base & ABC powder pressurised with nitrogen gas carrying handle and wall mounting bracket etc as required.Make-Safex/Fireshield/Ceasefire |
| 358 | Providing and Fixing of 4.5 Kgs. Capacity CO2 gas type ISI marked fire extinguisher (IS: 15683) fitted with high pressure 1 mtr. Long discharge hose & horn complete with refill gas, carrying handle and wall mounting bracket etc as required.Make-Safex/Fireshield/Ceasefire |
| 359 | Providing and Fixing of of 2 kG capacity Eco Friendly, Stored pressure type filled with HFC 134 A ( clean agent fire extinguishant having Zero Ozone depletion potential ) Clean Agent Fire Extinguishers with safety seal, pressure guage, controllable discharge mechanism, helium leak detection tested and conforming to IS 15683 complete with initial charge as required.Make-Safex/Fireshield/Ceasefire |
| 360 | Providing and Fixing of Mechanical Foam type fire extinguisher 9Lts. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket etc. complete, confirming to IS: 15683.Make-Safex/Fireshield/Ceasefire |
| 361 | Fire buckets round bottom type enamel painted, white inside & Red out side and Letter \\"FIRE\\" in black out side and handle with mounting bracket. |
| 362 | Fire bucket stand fabricated by MS angles to install 2 Nos. of buckets. |
| 363 | SIGNAGES |
| 364 | SIGNAGES:-Providing and installing in position the following type of sign boards made out of 3mm thick flexyle photoluminescent based glow in dark sheeting with luminous properties enclosed in a weather proof Uvstabilized film with UV screen printing by imported links pasted over3 mm thick cast acrylic from front side with 6 mm thick acrylic, -20 to+80 deg C, Suitablefor indoor use, greenish yellow, glow visible upto 4-6 hr in total darkness.Make-Prolite/Bajaj |
| 365 | Illumination Glow light for Exit Indication with Battery Back-up. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail