| 1 | CIVIL Cement concrete of proportion (1:3:6) in foundation and floors using 4cm size black broken granite stone aggregates of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15cm(6\\") thick to the required level ramming, watering, curing etc. complete including cost and conveyance royality taxes of all materials and labour with T&P required for the work etc. complete i as per direction of the Engineer-in-charge. |
| 2 | Fly Ash. brick masonry of size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge |
| 3 | RCC work of M-20 grade with 20mm & down-grade size black hard granite(crusher broken) chips including hoisting&laying.(Data for 15 cum. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge |
| 4 | Cutting straightening coiled bent up HYSD bars bending , binding , welding and jointing if necessary and tying the grills and placing in position as required for R.C.C work and for providing fan hooks hoisting lowering and tying including cost , conveyance and taxes of HYSD bars and binding wires 18 to 20 gauge required for the work and bending binding and tying the grills(payment will be made tow wards the weight of binding ware) . complete as per direction of the Engineer-in-charge. |
| 5 | 12mm thick Cement plaster (1:6) for brickwork including curing etc. complete including curing etc. complete. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. Ground Floor |
| 6 | First floor |
| 7 | Second Floor |
| 8 | Third Floor |
| 9 | Fourth Floor |
| 10 | Fifth Floor |
| 11 | Sixth Floor |
| 12 | 16mm thick Cement plaster (1:6) over brickwork including curing etc. complete including curing etc. complete. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. Ground Floor |
| 13 | First floor |
| 14 | Second Floor |
| 15 | Third Floor |
| 16 | 6mm thick Cement plaster (1:4) finished smooth per 1 Sqm. including curing etc. complete including curing etc. complete. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. Ground Floor |
| 17 | First floor |
| 18 | Second Floor |
| 19 | Third Floor |
| 20 | Supplying, fixing & Fixing of Two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. including cost of weather coat all cost of all labours and T&P etc. complete as per the direction of Engineer-in-charge. |
| 21 | Dressed seasoned salwood work framed and fixed in trusses,purlins, door, window, ventilaters and beams.. |
| 22 | W.I Clamp 33x38cm long |
| 23 | Fixing of 20 mm thick Granite in floors treads or stepps and landing on 25mm thick bed of Cement mortar 1:1 ( 1 Cement : 1 sand ) jointed with neat Cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete excluding cost of tiles or stones. |
| 24 | Fixing of Vetrified tiles in floors of Size 600x600mm of approved make coformaing to I.S:13755 laid on on 25mm thick bed of Cement mortar 1:1 (1 Cement : 1 Sand) and filling joint with white Cement of approved quality in slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of tiles or stones. ( For new work) |
| 25 | 2.5 cm thick grading concrete (1:2:2) on Roof slab with 6 mm size hard broken granite chips on new works etc all complete as per direction of Engineer-in-Charge. |
| 26 | Supplying fitting and fixing of Chequerred tiles in floors in cement mortar (1:4) etc all complete as per Direction of Engineer-in-Charge. |
| 27 | Supplying fitting fixing of Wardrobe made out up 19mm & 12mm BWR Ply & covered with 1mm Laminated (Sunmica) including Cromium coated handle 75mm with 125 x 25mm / 100mm with 150x25mm including all fitting including cost of material all taxes, T&P etc complete as per direction of Engineer -in-charge. |
| 28 | Providing & fixing of wall paneling made out of WPC of Crystal thermotech limited (Crystal Hybrido) frame 18mm thick strip of 50mm width @ 300mm C/C vertically and fixing of 12mm thick WPC as pannel fixed with screw and top face including cost, conveyance of all materials and labour, T&P etc. complete as per direction of Engineer-in-Charge. |
| 29 | Supplying and fixing of Roller blinds by fixing powder coated top channel, bottom channel with bottom end cap, control unit and good quality of 0.60 mm thick fabric of approved design and quality etc. complete. |
| 30 | Providing fitting and fixing of false ceilling with Aluminum anodised T section No 3215 with 2'-0\\" center to centre, L section No 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and P.V.C plug and the Aluminium grid 2'-0\\" x 2'-0\\" using 12.5 mm thick gypsum board of size 6'x4'suspended from ceilling etc complete as directed by the Engineer-in-charge |
| 31 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete |
| 32 | Providing and fixing M.S. Grill & Gate of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 33 | Painting two coats over wood and iron work with approved Enamel paint over a coat of primming, including cost and conveyance of all materials to site, and all labour charges complete as per direction of E.I.C. |
| 34 | Removing old lime or cement plaster from walls including raking out joints 12 mm deep and removing the debris within 50m lead. |
| 35 | Scraping old paint with scrapers, sand papering andwashing with soap water or soda including scaffolding charges upto 5M height. |
| 36 | Finishing wall surfaces with Acrylic wall putty (Water based) of approved make and finished smooth and even surfaces to receive painting including cost of all materials taxes, labour T&P etc. |
| 37 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) weather seal coat exterior grade of approved make & shade manufactured by reputed manufacturer like NEROLAC / ASIAN / BERGER / DULOX or equivalent to make an even finished surface over a coat of primer with water bond cement primer in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. Ground Floor |
| 38 | First floor |
| 39 | Second Floor |
| 40 | Third Floor |
| 41 | Fourth Floor |
| 42 | Fifth Floor |
| 43 | Sixth Floor |
| 44 | Wall painting 2-coats with plastic emulsion paint of approved shade on new work 1coats to give an even shade excluding cost of paint. |
| 45 | First floor |
| 46 | Second Floor |
| 47 | Third Floor |
| 48 | Dismantling and removing cement concrete including stacking of the materials for reuse and removing the debris within 50 meter lead. |
| 49 | Dismantling and removing 2.5 cm grading concrete from roof slab cleaning the surface lowering & removing the debris within 50 meter lead including cost of all labour, T&P etc. required complete as directed by the Engineer- in- Charge. |
| 50 | Dismantling and removing doors, windows, and ventilaters after carefully removing the bolts and nuts including stacking of the materials for reuse and removing the debris within 50 meter lead. |
| 51 | Providing and Fixing of S.S. boards of sizes as mentioned below along with the required letters to be approved by the Architect/ EIC. Samples have to be approved by the concerned before execution. The rate is inclusive of the S.S. board with fixing of the same along with Rates, Taxes, T&P all inclusive |
| 52 | ELECTRICAL INSTALLATION Recharge of Refridgerant Recharge of split/window type air conditioner |
| 53 | Replacement of Temperature Sensor in air conditioner |
| 54 | Replacement of outdoor compressor capacitor air conditioner |
| 55 | Replacement of indoor unit capacitor in air conditioner |
| 56 | Servicing of indoor unit and out door unit of split type air conditioner |
| 57 | Supply and fixing of 90-300 Volt automatic voltage stabiliser, 5 KVA rating (Make- V Guard/ Shakti/Microtek or any other approved make) |
| 58 | Supply and fixing of following rating 240 V/415 V \\"C\\" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. (Make-HPL/ Havells/ Legrand /L&T/C&S or any other approved make)SP MCB 6-32A C-series |
| 59 | DP MCB 6-32A C-series |
| 60 | Supply and fixing of 2.5 Micro farad Capacitor in Ceiling Fan |
| 61 | Supply and fixing of A.C Ceiling fan 48'' size, Minimum Air delivery-225 cum/min, 380rpm , BEE 1 star rated ISI Marked (Make-Usha striker neo/ Havells Velocity / Crompton HS or any other approved make) |
| 62 | Supply and fixing of 32amp motor starter on 2 module flush type GI box with suitable cover plate in front, 4 sqmm single core multistrand copper conductor as required between starter and 6-16 amp 3 pin shutterd socket on another flush type GI box |
| 63 | S/F of suitable size copper tube for outdoor unit to indoor unit complete with nitryle insulation etc as required. |
| 64 | S/F of 3/4\\" dia braided PVC drain pipe from indoor unit to out side of building for draining out of discharge water including making good the damage etc as requd. |
| 65 | Supply of Refrigerant for extra pipe |
| 66 | Supply and fixing of 18watt Led batten polycarbonate body tube light, Luminousity: 100 lumens, Colour Temperature: 6500 Kelvin.(Make- Havells/ Philips/ Crompton/ HPL or any other approved make) Please Enable Macros to View BoQ information |